916 resultados para All plastic device
Resumo:
The present article describes the preparation and characterization A anionic Collagen gels obtained from porcine intestinal submucosa after 72 h of alkaline treatment and in the form of rhamsan composites to develop injectable biomaterials for plastic for construction. All materials were characterized by SDS/polyacrylamide gel electrophoresis, infrared spectroscopy, thermal stability, potentiometric titration, rheological properties, and fluidity tests. Biocompatibility was appraised after the injection of anionic collagen:rhamsan composites at 2.5% in 60 North Folk rabbits. Independently of processing, the Collagen's secondary structure was preserved in all cases, and after 72 h of hydrolysis the Collagen was characterized by a carboxyl group content of 346 :L 9, which, at physiological pH, corresponds to an increase of 106 17 negative charges, in comparison to native Collagen, due to the selective hydrolysis of asparagine and glutamine carboxyamide side chain. Rheological studies of composites at pH 7.4 in concentrations of 2, 4, and 6% (in proportions of 75:1 and 50:1) showed a viscoelastic behavior dependent on the frequency, which is independent of concentration and proportion. In both, the concentration of the storage modulus always predominated over the loss modulus (G' > G and delta < 45 degrees). The results from creep experiments confirmed this behavior and showed that anionic collagen:rhamsan composites at pH 7.4 in the proportion of 50:1 are less elastic and more susceptible to deformation in comparison to gels in the proportion of 75:1, independent of concentration. This was further confirmed by flow experiments, indicating that the necessary force for the extrusion of anionic collagen:rhamsan composites, in comparison to anionic Collagen, was significantly smaller and with a smooth flow. Biocompatibility studies showed that the tissue reaction of anionic collagen:rhamsan composites at 2.5% in the proportion of 75:1 was compatible with the application of these gels in plastic reconstruction. These results suggest that the association of Collagen with rhamsan may be a good alternative in the replacement of glutaraidehyde to stabilize the microfibril assembly of commercial Collagen gel preparations. (c) 2005 Wiley Periodicals, Inc.
Resumo:
The objective of this experiment was to evaluate effects of treatments with intravaginal progesterone (N) device and/or 48 h temporary weaning (TW) on reproductive performance of postpartum anestrous crossbred Angus x Nelore cows, throughout the breeding season (BS). Anestrous cows (n = 296; 53 5 DPP, body condition score between 2.5 and 3.5, on a 1-5 scale) were assigned randomly to four treatments (2 x 2 factorial design): (1) Control Group (no treatment; n = 73); (2) TW Group (48 h TW beginning on day 0 of BS; n = 70); (3) P4 Group (Intravaginal P4 device between days -7 and 0 of BS; n = 73); and (4) P4+TW Group (Intravaginal P4 device between days -7 and 0 of BS followed by 48h TW; n=70). on day 0 of BS (when P4 devices were removed and TW was initiated), cows had their ovaries evaluated by ultrasonography aiming to evaluate size of the largest follicle. Signs of behavioral estrus were observed twice a day (morning and evening), between days 0 and 25 of BS, and cows observed in estrus were inseminated 12 h later. Between days 26 and 80 of BS, cows were submitted to natural service. Pregnancy diagnosis was conducted by transrectal ultrasonography on days 32 and 53 (pregnancies by AI) and 114 (pregnancies by natural service). Rates of detection of estrus during the first 3 days and within 25 days of BS were greater in cows receiving TW (45.0% compared with 9.6% and 50.0% compared with 29.5%, respectively; P < 0.01). Conception rate in cows inseminated in the first 3 days of BS was greater in cows treated with P4 (54.8% compared with 11.1 %; P < 0.01). Combining P4+TW increased pregnancy rate in the first 3 days (Control: 1.4%, TW: 4.3%, P4: 8.2% and P4+TW: 24.3%; P < 0.01) and in 25 days of BS (Control: 10.9%, TW: 7.1%, P4: 13.7% and P4+TW: 28.6%; P < 0.05). Pregnancy rate at the end of BS did not differ among treatment groups. In conclusion, TW alone increased estrous behavior whereas P4 alone benefited conception. Combining P4 with TW improved pregnancy rate with direct benefits to behavioral estrus and conception. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
An extensible internal device (EID) was developed to preserve growth plate during the treatment of fracture complications or segmental bone loss from tumour resection in children. Since this type of extensible, trans-physeal, internal fixation device has only been used in a few paediatric cases; the aim of this study was to evaluate an in vivo canine study, a surgical application of this device, and its interference with longitudinal growth of the non-fractured distal femur. Ton clinically healthy two- to three-month-old poodles weighing 1.5-2.3 kg were used. Following a medial approach to the right distal femur, one extremity of the EID, similar to a T-plate, was fixed in the femoral condyle with two cortical screws placed below the growth plate. The other extremity, consisting of an adaptable brim with two screw holes and a plate guide, was fixed in the third distal of the femoral diaphysis with two cortical screws. The EID was removed 180 days after application. All of the dogs demonstrated full weight-bearing after surgery. The values of thigh and stifle circumferences, and stifle joint motion range did not show any difference between operated and control hindlimbs. The plate slid in the device according to longitudinal bone growth, in all but one dog. In this dog, a 10.5% shortening of the femoral shaft was observed due to a lack of EID sliding. The other dogs had the some longitudinal lengths in both femurs. The EID permits longitudinal bone growth without blocking the distal femur growth plate if appropriately placed.
Resumo:
Purpose: This in vitro study evaluated the dimensional accuracy of two impression techniques (tapered and splinted) with two stock trays (plastic and metal) for implant-supported prostheses. Materials and Methods: A master cast with four parallel abutment analogs and a passive framework were fabricated. Polyvinyl siloxane impression material was used for all impressions with two metal stock trays and two plastic stock trays (closed and open trays). Four groups (tapered plastic, splinted plastic, tapered metal, and splinted metal) and a control group (master cast) were tested (n = 5 for each group). After the framework was seated on each of the casts, one abutment screw was tightened, and the marginal gap between the abutment and framework on the other side was measured with a stereomicroscope. The measurements were analyzed with the Kruskal-Wallis one-way analysis of variance on ranks test followed by the Dunn method. Results: The mean values (+/- standard deviations) for the abutment/framework interface gaps were: master cast, 32 +/- 2 mu m; tapered metal, 44 +/- 10 mu m; splinted metal, 69 +/- 28 mu m; tapered plastic, 164 +/- 58 mu m; splinted plastic, 128 +/- 47 mu m. No significant difference was detected between the master cast, tapered metal, and splinted metal groups or between the tapered and splinted plastic groups. Conclusions: In this study, the rigidity of the metal stock tray ensured better results than the plastic stock tray for implant impressions with a high-viscosity impression material (putty). Statistically similar results were obtained using tapered impression copings and splinted squared impression copings. The tapered impression copings technique and splinted squared impression copings technique with a metal stock tray produced precise casts with no statistically significant difference in interface gaps compared to the master cast. INT J ORAL MAXILLOFAC IMPLANTS 2012;27:544-550.
Resumo:
Studies on patterns of habitat use by mammals are necessary for understanding the mechanisms involved in their distribution and abundance. In this study, we used the spool-and-line method to investigate habitat utilization by two sigmodontine rodents from Brazilian Cerrado, Necromys lasiurus and Oryzomys scotti. We conducted the study in a Cerrado area in central Brazil (15 degrees 56'S and e 47 degrees 56'W) where the animals were caught in an area of 7.68 ha of Cerrado sensu stricto. Captured individuals were marked, equipped with a spool-and-Line device, and released at the same capture point. The next day we followed the thread to record their daily movements and find their nests. To investigate microhabitat selection we compared habitat characteristics along traits of each studied species with general habitat characteristics of the study area. Although the mean 24-h distance was greater for N. lasiurus (mean +/- SE: 41.9 +/- 42.2 m, N=3) than for O. scotti (28.7 +/- 14.2 m, N=6) this difference was not significant (Mann-Whitney test, U=26, P>0.6). We detected significant differences among observed microhabitats variables of both species and available microhabitat characteristics as determined by discriminant analysis (Wilks's lambda F=3.001; df=14, 116; P<0.001). Both species were associated to microhabitat characteristics whose values differed markedly from the overall available habitat. Along the first canonical discriminant function of the DFA both them were associated with greater grass height than the mean height available and along the second axis N. lasiurus selected areas with higher fruit availability and more shelters than those selected by 0. scotti. For stronger inferences regarding differential patterns of habitat utilization by Cerrado rodents we suggest the simultaneous use of both spool-and-line and standard trapping methods. (c) 2005 Deutsche Geseltschaft fur Saugetierkunde. Published by Elsevier GmbH. ALL rights reserved.
Resumo:
A utilização de sacos plásticos graduados para a medida da vazão de pulverizadores está ba stante di fundida entre técnicos e agricultores. 0 seu emprego é simples, consistindo, basicamente, em se coletar o líquido pulverizado por um bico durante o período equivalente ao deslocamento de 50 metros. O volume coletado é indicado numa escala graduada impr essa nos sacos calib rad ores e fornece diretament e a vazão em 1/ha. Firmas que comercializam os agro fármacos distribuem esses instrumentos aos agricultores, muitas vezes com propósitos puramente promocionais. Cinco sacos graduados de cada uma das 6 marcas diferentes foram aferidos. Agua a 20°C foi adicionada até as marcas de 100 1/ha, 250 1/ha e 400 1/ha. Esses volumes foram medidos em pro veta graduada e o volume real de pulverização foi calculado. Todos os saquinhos testados mostraram erros, em alguns bastante elevados, atingindo desvios de até 35,2%. Considerando esses resultados, é recomendada maior atenção na fabricação desses instrumentos. São sugeridas também algumas modificações da maneira de imprimir a escala e no conteúdo das instruções de uso.
Resumo:
The temporal muscles (anterior position), and the masseter and suprahyoid muscles were studied electromyographically in 15 subjects with ages ranging from 18 to 35 years, showing normal occlusion (Class I of angle), complete dentition and no dysfunction of the stomatognathic system. The volunteers sat comfortably in a chair, keeping the Frankfurt plane parallel to the boor; the muscles were analysed in the mandibular resting position through a number of stages: with minimum exteroceptive stimuli, relaxation with soft music, abolition of the intrabuccal negative pressure through a plastic tube, stress provoked by an electronic game, disocclusion of posterior teeth using the occlusal splint and finally withdrawal of this device. The electromyographic results were analysed statistically. The samples, were analysed for all of the frequencies of motor units, in a 1-min period. It was found that there were statistically significant difference between the relaxation stages as compared with the withdrawal of negative intraoral pressure and mainly with the stress phase, being this only on the suprahyoid muscles, with 5% significance.
Resumo:
A pressure analgesiometric device was developed for unrestrained cats. Eleven cats were studied. Stimulation was via three rounded pins within a bracelet on the forearm. The pins were advanced by manual bladder inflation. Bladder pressure was measured using a strain gauge pressure transducer. The threshold was recorded at the behavioural end point. Thresholds were measured at 5 and 15 min intervals for 2-4 h, after removal/replacement of the cuff, for 120 min after SC butorphanol (0.4 mg/kg), and with mild skin inflammation at the testing site. Data were analysed using ANOVA. Pressure thresholds in untreated cats were around 150 mmHg. The minimum interval for testing was established as 15 min. Data were reproducible over 4 h and beyond 24 h. Thresholds in 5 cats increased (P < 0.05) above baseline for 45 min after butorphanol with a maximum increase of 270 +/- 182 mmHg at 10 min. Thresholds decreased with inflammation. The method appears suitable for feline analgesia investigations. (c) 2006 Elsevier Ltd. All rights reserved.
Resumo:
An apiary trial was conducted in 1997 in Sardinia, Italy, to verify the effectiveness of fluvalinate in polyvinyl chloride strips and flumethrin in polyethylene strips against Varroa jacobsoni Oudemans. Two indices to evaluate the efficacy of the treatments were adopted: percentage change in mite infestation of worker-sealed brood cells considering only treated hives and percentage change in mite mortality, and the natural variation in mite populations recorded in control hives during the trial. All acaricide treatments reduced the level of mite infestation of both sealed brood and adult bees. However, their effectiveness was slightly reduced in comparison to previous studies because of mite resistance phenomena. Portions of polyethylene strips of flumethrin from treated hives were sampled weekly to determine acaricide persistence using gas chromatography. After 4 wk, a slight reduction (approximate to9%) of the active ingredient content was observed, A laboratory bioassay also was performed to establish the resistance of adult female mites to fluvalinate, Mites were sampled from the experimental apiary and from various Sardinian apiaries which had primarily been subjected to fluvalinate applications in plastic strips or wood inserts for years. Mite resistance varied from 0 to 96%, depending on the acaricide management adopted, the lowest resistance level occurred in an apiary where pyrethroids had never been used, whereas the highest level occurred in an apiary with intensive use of fluvalinate in wood inserts.
Resumo:
Rare earth (RE) ions have spectroscopic characteristics to emit light in narrow lines, which makes RE complexes with organic ligands candidates for full color OLED (Organic Light Emitting Diode) applications. In particular, beta-diketone rare earth (RE(3+)) complexes show high fluorescence emission efficiency due to the high absorption coefficient of the beta-diketone and energy transfer to the central ion. In this work, the fabrication and the electroluminescent properties of devices containing a double and triple-layer OLED using a new beta-diketone complex, [Eu(bmdm)(3)(tppo)(2)], as transporting and emitting layers are compared and discussed. The double and triple-layer devices based on this complex present the following configurations respectively: device 1: ITO/TPD (40 nm)/[Eu(bmdm)(3)(tppo)(2)] (40 nm)/Al (150 nm); device 2: ITO/TPD (40 nm)/[Eu(bmdm)(3) (tppo)(2)] (40 nm)/Alq(3) (20 nm)/Al (150 nm) and device 3: ITO/TPD (40 nm)/bmdm-ligand (40 nm)/Al (150 nm), were TPD is (N,N'-diphenyl-N,N'-bis(3-methylphenyl)-1,1-biphenil-4,4-diamine) and bmdm is butyl methoxy-dibenzoyl-methane. All the films were deposited by thermal evaporation carried out in a high vacuum system. These devices exhibit high intensity photo- (PL) and electro-luminescent (EL) emission. Electroluminescence spectra show emission from Eu(3+) ions attributed to the (5)D(0) to (7)F(J) (J = 0, 1, 2, 3 and 4) transitions with the hypersensitive (5)D(o) -> (7)F(2) transition (around 612 nm) as the most prominent one. Moreover, a transition from (5)D(1) to (7)F(1) is also observed around 538 nm. The OLED light emission was almost linear with the current density. The EL CIE chromaticity coordinates (X = 0.66 and Y = 0.33) show the dominant wavelength, lambda(d) = 609 nm, and the color gamut achieved by this device is 0.99 in the CIE color space. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Three juvenile Brazilian sharpnose sharks (Rhizoprionodon lalandii) caught in gillnets in southeast Brazil, southwest Atlantic, were found with plastic debris rings around their gill or mouth region. The rings caused severe abrasion on the sharks' tissues as the animal grew, the collars probably hampering normal feeding and/or ventilation since two of the collared individuals were emaciated. The rings were identified as detachable lid parts from plastic bottles, likely thrown overboard by fishery and/or recreation boats. As several carcharhinid shark species dwells and reproduce in shallow waters, the impact of discarded plastic debris likely is greater on this shark type. (C) 2002 Elsevier B.V. Ltd. All rights reserved.
Resumo:
Patterns of nest construction and nest site selection of two murid rodents of the Brazilian Atlantic rainforest were described. The animals were captured in an area of about 1.5 ha of primary forest, marked, equipped with a spool-and-line device and released at the capture point. The next day we followed the thread to find their nests. In total 11 nests of Nectomys squamipes (Brants, 1827) and 13 of Oryzomys intermedius (Leche, 1886) were found. They were all egg-shaped, about 15 cm long and 10 cm wide, without any apparent entrance and consisted of dry leaves and grass. The two species differed in the selection of nest sites. The nests of N. squamipes were close to streams and built inside decomposed fallen logs or using natural entrances between the soil and tangled roots or rocky crevices. Nests of O. intermedius were built under or inside fallen logs and inside aerial root systems of palms. The spool-and-line technique used here is useful to provide detailed information on several aspects of the ecology and natural history of small mammals.
Resumo:
Purpose: This article reports preliminary clinical results of the Speed Master system, a method for immediate loading of implants for the treatment of mandibular edentulism. Materials and Methods: Fifteen patients with edentulous mandibles were consecutively included in the study. Each received 4 implants between the mental foramina placed using the system's surgical guides. Permanent fixed prostheses fabricated over premanufactured titanium bars were attached to the implants on the day of implant placement. The patients were followed for 15 to 27 months (mean, 19 months). Peri-implant tissues were periodically evaluated. Marginal bone loss was monitored with periapical radiographs using a computerized technique. Satisfaction was assessed by means of a questionnaire. Results: The overall implant and prosthetic survival rates were 100%. At the time of the final follow-up visit, mean marginal bone loss was 1.11 mm, and bleeding on probing was not observed. Only 6.7% of the patients reported any discomfort during treatment, and all patients would recommend the procedure to others. Discussion: The immediate loading of implants placed in the edentulous mandible with the Speed Master surgical and prosthetic protocol reduces treatment time and number of surgical procedures in comparison to classic delayed loading protocols. Conclusion: The rehabilitation of the mandible with an immediately delivered occlusally loaded hybrid prosthesis supported by 4 implants does not appear to jeopardize the success of the osseointegration and represents a viable treatment option.
Resumo:
Accessing vaginal pH is fundamental during gynaecological visit for the detection of abnormal vaginal flora (AVF), but use of pH strips may be time-consuming and difficult to interpret. The aim of this study was to evaluate the VS-SENSE test (Common Sense Ltd, Caesarea, Israel) as a tool for the diagnosis of AVF and its correlation with abnormal pH and bacterial vaginosis (BV). The study population consisted of 45 women with vaginal pH ≥ 4.5 and 45 women with normal pH. Vaginal samples were evaluated by VS-SENSE test, microscopy and microbiologic cultures. Comparing with pH strips results, VS-SENSE test specificity was 97.8% and sensitivity of 91%. All severe cases of BV and aerobic vaginitis (AV) were detected by the test. Only one case with normal pH had an unclear result. Concluding, VS-SENSE test is easy to perform, and it correlates with increased pH, AVF, and the severe cases of BV and AV. Copyright © 2010 Gilbert G. G. Donders et al.
Resumo:
A major UK initiative, entitled 'Mapping the Underworld', is seeking to address the serious social, environmental and economic consequences arising from an inability to locate accurately and comprehensively the buried utility service infrastructure without resorting to extensive excavations. Mapping the Underworld aims to develop and prove the efficacy of a multi-sensor device for accurate remote buried utility service detection, location and, where possible, identification. One of the technologies to be incorporated in the device is low-frequency vibro-acoustics, and application of this technique for detecting buried infrastructure is currently being investigated. Here, the potential for making a number of simple point vibration measurements in order to detect shallow-buried objects, in particular plastic pipes, is explored. Point measurements can be made relatively quickly without the need for arrays of surface sensors, which can be expensive, time-consuming to deploy, and sometimes impractical in congested areas. At low frequencies, the ground behaves as a simple single-degree-of-freedom (mass-spring) system with a well-defined resonance, the frequency of which will depend on the density and elastic properties of the soil locally. This resonance will be altered by the presence of a buried object whose properties differ from the surrounding soil. It is this behavior which can be exploited in order to detect the presence of a buried object, provided it is buried at a sufficiently shallow depth. The theoretical background is described and preliminary measurements are made both on a dedicated buried pipe rig and on the ground over a domestic waste pipe. Preliminary findings suggest that, for shallow-buried pipes, a measurement of this kind could be a quick and useful adjunct to more conventional methods of buried pipe detection. © 2012 Elsevier Ltd. All rights reserved.