234 resultados para Airflow
Resumo:
Although the presence of an olfactory impairment in Parkinson's disease (PD) has been recognized for 25 years, its cause remains unclear. Here we suggest a contributing factor to this impairment, namely, that PD impairs active sniffing of odorants. We tested 10 men and 10 women with clinically typical PD, and 20 age- and gender-matched healthy controls, in four olfactory tasks: (i) the University of Pennsylvania smell identification test; (ii and iii) detection threshold tests for the odorants vanillin and propionic acid; and (iv) a two-alternative forced-choice detection paradigm during which sniff parameters (airflow peak rate, mean rate, volume, and duration) were recorded with a pneomatotachograph-coupled spirometer. An additional experiment tested the effect of intentionally increasing sniff vigor on olfactory performance in 20 additional patients. PD patients were significantly impaired in olfactory identification (P < 0.0001) and detection (P < 0.007). As predicted, PD patients were also significantly impaired at sniffing, demonstrating significantly reduced sniff airflow rate (P < 0.01) and volume (P < 0.002). Furthermore, a patient's ability to sniff predicted his or her performance on olfactory tasks, i.e., the more poorly patients sniffed, the worse their performance on olfaction tests (P < 0.009). Finally, increasing sniff vigor improved olfactory performance in those patients whose baseline performance had been poorest (P < 0.05). These findings implicate a sniffing impairment as a component of the olfactory impairment in PD and further depict sniffing as an important component of human olfaction.
Resumo:
Introdução: A DPOC é uma doença respiratória prevenível e tratável, caracterizada por limitação persistente ao fluxo aéreo, hiperinsuflação e aprisionamento aéreo. A dispneia e a intolerância aos esforços, decorrentes destas alterações fisiopatológicas sofre influência de vários fatores. Dentre estes, o recrutamento e a sobrecarga imposta aos músculos inspiratórios e expiratórios são de fundamental importância, porém a participação destes ainda não foi completamente elucidada em diferentes gravidades da doença. Objetivos: O objetivo principal deste estudo foi avaliar a mecânica ventilatória, e o grau de recrutamento da musculatura inspiratória e expiratória na DPOC leve e grave, na condição de repouso e durante um teste máximo de exercício, comparado a um grupo de indivíduos saudáveis. Metodologia: Trata-se de um estudo transversal envolvendo 36 indivíduos, sendo 24 pacientes portadores de DPOC e 12 voluntários sadios. As avaliações foram divididas em 2 visitas. No D1, foram realizadas uma avaliação clínica, avaliação de dispneia (mMRC) e de qualidade de vida (SGRQ), além da prova de função pulmonar completa. Na 2ª visita, realizada com intervalo de 1 semana, foram avaliadas: as pressões respiratórias máximas estáticas por meio de métodos volitivos (PImax, PEmax, SNIP, Pes sniff, Pga sniff e Pdi sniff) e não volitivos (Twitch cervical bilateral e T10); avaliação da sincronia toracoabdominal por pletismografia de indutância; avaliação do recrutamento dos músculos inspiratórios e expiratórios ao repouso pela eletromiografia de superfície; e, posteriormente, um teste de exercício cardiopulmonar incremental para estudo de todas essas variáveis no esforço. Resultados: Foram avaliados 24 pacientes (12 leves e 12 graves) e 12 indivíduos saudáveis da mesma faixa etária. A maioria dos pacientes apresentava comprometimento significativo da qualidade de vida e os pacientes do grupo grave eram mais sintomáticos. A função pulmonar encontrava-se alterada na maioria dos pacientes. Destes, 79,2% apresentavam aprisionamento aéreo e 70,8% tinham redução da DLCO. Tais alterações foram semelhantes nos 2 grupos de pacientes. A força muscular estática medida por métodos volitivos e não volitivos estava reduzida nos 2 grupos e mostrou relação com o VEF1. No exercício, a dispneia foi o principal motivo para interrupção do teste em 70% dos pacientes. A HD esteve presente em 87,5% dos pacientes. O comportamento das pressões respiratórias foi significativamente diferente entre os 3 grupos. Os pacientes com DPOC apresentaram maior atividade diafragmática (Pdi) comparado aos controles e a participação da musculatura expiratória também foi maior neste grupo, principalmente nos graves. Apesar disso, os pacientes com DPOC apresentaram uma eficiência mecânica reduzida, ou seja, esse incremento da força muscular foi insuficiente para manter uma ventilação adequada para uma determinada carga. Com o aumento da demanda ventilatória, houve recrutamento precoce e progressivo dos músculos inspiratórios e expiratórios durante o exercício. O trabalho resistivo e o expiratório foram significativamente diferentes entre os controles e os pacientes com DPOC desde o início do exercício. Como consequência destas alterações, a intensidade da dispneia durante o TECP foi maior nos pacientes com DPOC (leve e grave) para a mesma carga e mesma ventilação-minuto (VE), quando comparada aos indivíduos do grupo-controle. Conclusões: O conjunto destes achados demonstra que o comprometimento dos músculos inspiratórios e expiratórios contribuiu significativamente para a dispneia e a intolerância ao exercício tanto no DPOC leve quanto no DPOC grave. E que este comprometimento pode não ser detectado com os testes máximos de força ao repouso
Resumo:
En el ámbito de acústica de la edificación es común el uso de materiales fibrosos como materiales absorbentes acústicos. Uno de estos materiales cada vez más utilizado es la lana de poliéster. Un problema que presenta el chip virgen de poliéster es que se obtiene del petróleo, cuyo precio no hace más que incrementarse en los últimos años. En este trabajo se presenta una lana de poliéster alternativa, obtenida mediante el tratamiento del PET, a través del conveniente ciclo de reciclado de botellas de plástico. Se comparan valores del coeficiente de absorción; en incidencia normal y en cámara reverberante de los materiales elaborados a partir de chip virgen y de las nuevas lanas obtenidas del PET. Además, se propone un modelo empírico de comportamiento acústico de estas nuevas lanas. Los resultados obtenidos han sido favorables, la fibra virgen ya ha sido sustituida por fibra reciclada en su proceso de fabricación.
Resumo:
Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014
Resumo:
ight standard inbred mouse strains were evaluated for ethanol effects on a refined battery of behavioral tests in a study that was originally designed to assess the influence of rat odors in the colony on mouse behaviors. As part of the design of the study, two experimenters conducted the tests, and the study was carefully balanced so that equal numbers of mice in all groups and times of day were tested by each experimenter. A defect in airflow in the facility compromised the odor manipulation, and in fact the different odor exposure groups did not differ in their behaviors. The two experimenters, however, obtained markedly different results for three of the tests. Certain of the experimenter effects arose from the way they judged behaviors that were not automated and had to be rated by the experimenter, such as slips on the balance beam. Others were not evident prior to ethanol injection but had a major influence after the injection. For several measures, the experimenter effects were notably different for different inbred strains. Methods to evaluate and reduce the impact of experimenter effects in future research are discussed.
Resumo:
The anatomy of the domestic duck lung was studied macroscopically, by casting and by light, transmission, and scanning electron microscopy. The lung had four categories of secondary bronchi (SB), namely, the medioventral (MV, 4-5), laterodorsal (LD, 6-10), lateroventral (LV, 2-4), and posterior secondary bronchi (PO, 36-44). The neopulmonic parabronchi formed an intricate feltwork on the ventral third of the lung and inosculated those from the other SB. The lung parenchyma was organized into cylindrical parabronchi separated by thin septa containing blood vessels. Atria were shallow and well-fortified by epithelial ridges reinforced by smooth muscle bundles and gave rise to 2-6 elongate infundibulae. Air capillaries arose either directly from the atria or from infundibulae and were tubular or globular in shape with thin interconnecting branches. The newly described spatial disposition of the conducting air conduits closely resembles that of the chicken. This remarkable similarity between the categories, numbers, and 3D arrangement of the SB in the duck and chicken points to a convergence in function-oriented design. To illuminate airflow dynamics in the avian lung, precise directions of airflow in the various categories of SB and parabronchi need to be characterized.
Resumo:
Thesis (Ph.D.)--University of Washington, 2016-05
Resumo:
The influence of a new aeration system on the biopile performance was investigated. The purpose was to increase biodegradation efficiency by optimising airflow through the pile. During a 1-month field trial, the performance of a new system using two perforated vertical pipes with wind-driven turbines was compared with that of a standard pile configuration with two horizontal perforated pipes. Both piles were composed of a similar mix of diesel-contaminated soils, woodchips, compost and NPK fertiliser. Hydrocarbons were recovered using solvent extraction, and determined both gravimetrically and by gas chromatography. Total heterotrophs, pH and moisture content were also assessed. Air pressure measurements were made to compare the efficiency of suction in the pipes. Results at the end of the experiment showed that there was no significant difference between the two piles in the total amount of hydrocarbon biodegradation. The normalised degradation rate was, however, considerably higher in the new system than in the standard one, suggesting that the vertical venting method may have improved the efficiency of the biological reactions in the pile. The pressure measurements showed a significant improvement in the suction produced by the new aeration system. However, many factors other than the airflow (oxygen supply) may influence and limit the biodegradation rates, including moisture content, age of contaminants and the climatic conditions. Additional experiments and modelling need to be carried out to explore further the new aeration method and to develop criteria and guidelines for engineering design of optimal aeration schemes in order to achieve maximum biodegradation in biopiles. (C) 2003 Elsevier Ltd. All rights reserved.
Resumo:
Conclusion. The new Provox(R) NID (TM) non- indwelling voice prosthesis investigated in this study provides a good option for laryngectomized patients using non- indwelling voice prostheses and can potentially improve safety and increase patients' satisfaction with their voice and speech. Objective. To investigate the feasibility of and patient satisfaction with the Provox NID non- indwelling voice prosthesis. Material and methods. Pre- and post- study questionnaires were used to evaluate the patients' former voice prosthesis and the Provox NID voice prosthesis. In addition, measurements of pull- out force, maximum phonation time and loudness were made for both voice prostheses. In vitro measurements of airflow characteristics were also made. Following a 6- week trial, all patients provided feedback on the new voice prosthesis and the results were used to further improve the Provox NID. This final version of the new voice prosthesis was subsequently trialled and evaluated by 10 patients 6 months later. Results. Overall results showed that patient satisfaction with the Provox NID non- indwelling voice prosthesis was favourable. The pull- out force for the new prosthesis was significantly higher than that for the formerly used prosthesis and its aerodynamic characteristics were better.
Resumo:
This paper investigates the tidal effects on aeration conditions for plant root respiration in a tidal marsh. We extend the work of Ursino et al. ( 2004) by using a two-phase model for air and water flows in the marsh. Simulations have been conducted to examine directly the link between the airflow dynamics and the aeration condition in the marsh soil. The results show that the effects of entrapped air on water movement in the vadose zone are significant in certain circumstances. Single-phase models based on Richards' equation, which neglect such effects, may not be adequate for quantifying the aeration condition in tidal marsh. The optimal aeration condition, represented by the maximum of the integral magnitude of tidally advected air mass ( TAAM) flux, is found to occur near the tidal creek for the four soil textures simulated. This may explain the observation that some salt marsh plant species grow better near tidal creeks than in the inner marsh areas. Our analyses, based on the two-phase model and predicted TAAM flux magnitude, provide further insight into the positive feedback'' mechanism proposed by Ursino et al. ( 2004). That is, pioneer plants may grow successfully near the creek where the root aeration condition is optimal. The roots of the pioneer plants can soften and loosen the rhizosphere soil, which increases the evapotranspiration rate, the soil porosity, and absolute permeability and weakens the capillary effects. These, in turn, improve further the root aeration conditions and may lead to colonization by plants less resistant to anaerobic conditions.
Resumo:
Amyloodinium ocellatum, a frequently encountered parasite in marine aquaculture, was investigated to determine if infective dinospore stages could be transported in aerosol droplets. We used an in vivo model incorporating static and dynamic airflow systems and found dinospores of A. ocellatum could travel in aerosol droplets (up to 440 turn in a static system and up to 3 m in a dynamic one). This is the first record of this transmission pathway for a marine protozoan parasite. It is possible that other marine protozoans can transfer via the aerobiological pathway. Management of A. ocellatum infections in aquaculture facilities could be affected, particularly where tanks and ponds are situated in close proximity. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
There are many physical factors that can affect the self-heating rate of coal. The presence of seam gas has often been referred to as inhibiting coal self-heating due to the limited access of oxidation sites created by the presence of the gas adsorbed on the coal pores. Similarly, the presence of bed moisture in the coal also acts as an inhibitor of oxidation by blocking access of air into the pores. Gas drainage of a coal seam prior to mining removes both gas and moisture from the seam. Bulk coal self-heating tests in a two-metre column on both gassy, as-mined and gas-drained, dried high volatile bituminous coal show that removal of gas and moisture from the coal accelerates the rate of self-heating to thermal runaway from 8.5 days to 4.25 days, from a start temperature of 30°C, with an airflow of 0.25 L/min. The corresponding gas evolution pattern for each of these situations is different. Therefore, it is necessary to take this change in coal condition into consideration when developing a spontaneous combustion management plan.
Resumo:
Samples of Various industrial or pilot plant spray-dried materials were obtained from manufacturers together with details of drying conditions and feed concentrations. The samples were subjected to qualitative and semi-quantitative examination to identify structural and morphological features. The results were related to measured bulk physical properties and to drying conditions. Single particles were produced in a convective drying process Analogous to spray drying, in which different solids or mixtures of solids were dried from solutions, slurries or pastes as single suspended droplets. The localized chemical and physical structures were analysed and in some cases the retention of volatiles monitored. The results were related to experimental conditions, viz.; air temperature, initial solids concentration and the degree of feed aeration. Three distinct categories of particle morphology were identified, i.e.; crystalline, skin-forming and agglomerate. Each category is evidence of a characteristic drying behaviour which is dependent on initial solids concentration. the degree of feed aeration, and drying temperature. Powder flow ability, particle and bulk density, particle-size, particle friability, and the retention of volatiles bear a direct relationship to morphological structure. Morphologies of multicomponent mixtures were complex, but the respective migration rates of the solutes were dependent on drying temperature. Gas-film heat and SDSS transfer coefficients of single pure liquid droplets were also measured over a temperature range of 50•C to 200•C under forced convection. Balanced transfer rates were obtained attributed to droplet instability or oscillation within the airflow, demonstrated in associated work with single free-flight droplets. The results are of relevance to drier optimisation and to the optimisation of product characteristics, e.g.; particle strength and essential volatiles-retention, in convective drying.
Resumo:
There is currently, no ideal system for studying nasal drug delivery in vitro. The existing techniques such as the Ussing chamber and cell culture all have major disadvantages. Most importantly, none of the existing techniques accurately represent the interior of the nasal cavity, with its airflow and humidity; neither do they allow the investigation of solid dosage forms.The work in this thesis represents the development of an in vitro model system in which the interior characteristics of the nasal cavity are closely represented, and solid or minimal volume dosage forms can be investigated. The complete nasal chamber consists of two sections: a lower tissue, viability chamber and an upper nasal chamber. The lower tissue viability chamber has been shown, using existing tissue viability monitoring techniques, to maintain the viability of a number of epithelial tissues, including porcine and rabbit nasal tissue, and rat ileal and Payers' patch tissue. The complete chamber including the upper nasal chamber has been shown to provide tissue viability for porcine and rabbit nasal tissue above that available using the existing Ussing chamber techniques. Adaptation of the complete system, and the development of the necessary experimental protocols that allow aerosol particle-sizing, together with videography, has shown that the new factors investigated, humidity and airflow, have a measurable effect on the delivered dose from a typical nasal pump. Similarly, adaptation of the chamber to fit under a confocal microscope, and the development of the necessary protocols has shown the effect of surface and size on the penetration of microparticulate materials into nasal epithelial tissues. The system developed in this thesis has been shown to be flexible, in allowing the development of the confocal and particle-sizing systems. For future nasal drug delivery studies, the ability to measure such factors as the size of the delivered system in the nasal cavity, the depth of penetration of the formulation into the tissue are essential. Additionally, to have access to other data such as that obtained from drug transport in the same system, and to have the tissue available for histological examination represents a significant advance in the usefulness of such an in vitro technique for nasal delivery.
Resumo:
Rotating fluidised Beds offer the potential for high intensity combustion, large turndown and extended range of fluidising velocity due to the imposition of an artificial gravitational field. Low thermal capacity should also allow rapid response to load changes. This thesis describes investigations of the validity of these potential virtues. Experiments, at atmospheric pressure, were conducted in flow visualisation rigs and a combustor designed to accommodate a distributor 200mm diameter and 80mm axial length. Ancillary experiments were conducted in a 6" diameter conventional fluidised bed. The investigations encompassed assessment of; fluidisation and elutriation, coal feed requirements, start-up and steady-state combustion using premixed propane and air, transition from propane to coal combustion and mechanical design. Assessments were made of an elutriation model and some effects of particle size on the combustion of premixed fuel gas and air. The findings were: a) more reliable start-up and control methods must be developed. Combustion of premixed propane and air led to severe mechanical and operating problems. Manual control of coal combustion was inadequate. b) Design criteria must encompass pressure loss, mechanical strength and high temperature resistance. The flow characteristics of ancillaries and the distributor must be matcheo. c) Fluidisation of a range of particle sizes was investigated. New correlations for minimum fluidisation and fully supported velocities are proposed. Some effects on elutriation of particle size and the distance between the bed surface and exhaust port have been identified. A conic distributor did not aid initial bed distribution. Furthermore, airflow instability was encountered with this distributor shape. Future use of conic distributors is not recommended. Axial solids mixing was found to be poor. A coal feeder was developed which produced uniform fuel distribution throughout the bed. The report concludes that small scale inhibits development of mechanical design and exploration of performance. future research requires larger combustors and automatic control.