999 resultados para ABSORPTION-SPECTROMETRY


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Thermospray flame furnace Atomic Absorption Spectrometry (TS-FF-AAS) was used for the total determination of Cd, Pb and Zn in fresh water and seawater samples at µg L-1 levels, and in marine sediment samples at µg g-1 levels. Using a sample loop of 50 µL and a peristaltic pump the samples were transported into the metallic tube placed over an air/acetylene flame, through a ceramic capillary (o.d. = 3.2 mm) containing two parallel internal orifices (i.d = 0.5 mm). The detection limits determined for Cd, Pb and Zn using a synthetic water matrix (2.5% m/v NaCl, 0.5% m/v MgCl2 and 0.8% m/v CaCl2) were 0.32 µg L-1; 2.6 µg L-1 and 0.21 µg L-1 respectively. The methodology by TS-FF-AAS was validated by determination of Cd, Pb and Zn in certified reference materials of water and marine sediment, and the t-test for differences between means was applied. No statistically significant differences were established in fresh water and seawater (p>0.05), whereas differences became apparent in marine sediment (p<0.03).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The use of an internal standard (IS) in ET AAS can be considered a new trend after the commercial introduction of a simultaneous spectrometer. The evaluation of experimental data to choose the most appropriate IS can be done by comparing correlation graphs. They were used to verify the resemblance among the simultaneous measurements obtained for the analyte(s) and the IS by inductively coupled plasma optical emission spectrometry (ICPOES). The judicious selection of IS by using correlation graphs for determinations by ET AAS can be exploited to improve the precision and accuracy of the analytical results. Therefore, a new approach for studying the use of IS in ET AAS is presented.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work proposes a simple, fast and inexpensive method to determine As in natural waters, using X-ray fluorescence. 50 µL of each sample containing 100 mg L-1 of yttrium as internal standard were deposited over a 2.5 µm thickness MylarTM film. The samples were dried at 50 °C for 2 h. X-ray spectra were obtained using an EDXRF apparatus. The accuracy was determined by analyte addition/recovery and by comparison with Hydride Generation Atomic Absorption Spectrometry (HG AAS). A recovery of about 100% was obtained and the results were in good agreement with HG AAS. The method showed a relative standard deviation of 6.8% and a detection limit of 10.5 µg L-1 of As.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The subsoil of the Vale do Ribeira was the focus of mining industries for the exploration of lead, mainly inside the park - PETAR. Despite the fact that the exploration has ended, the environmental effects of those activities are still present, due to great amounts of heavy metals that are leached. Concentrations of pseudo-total and bioavailable metals were determined in sediment samples of the Betari River, using atomic absorption spectrometry. The results demonstrated that the sediments are contaminated by Pb, Zn and Cu. The findings can contribute to an efficient and environmentally and economically adequate management of the park, for the conservation and the protection of the area.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A solid phase extraction procedure using Amberlite XAD-1180/Pyrocatechol violet (PV) chelating resin for the determination of iron and lead ions in various environmental samples was established. The procedure is based on the sorption of lead(II) and iron(III) ions onto the resin at pH 9, followed by elution with 1 mol/L HNO3 and determination by flame atomic absorption spectrometry. The influence of alkaline, earth alkaline and some transition metals, as interferents, are discussed. The recoveries for the spiked analytes were greater than 95%. The detection limits for lead and iron by FAAS were 0.37 µg/L and 0.20 µg/L, respectively. Validation of the method described here was performed by using three certified reference materials (SRM 1515 Apple Leaves, SRM 2711 Montana Soil and NRCC-SLRS-4 Riverine Water). The procedure was successfully applied to natural waters and human hair.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work describes a systematic study for bovine liver sample preparation for Cd and Pb determination by solid sampling electrothermal atomic absorption spectrometry. Samples were prepared using different procedures: (1) drying in a household microwave oven followed by drying in a stove at 60 ºC until constant mass, and (2) freeze-drying. Ball and cryogenic mills were used for grinding. Particle size, sample size and micro sample homogeneity were investigated. All prepared samples showed good homogeneity (He < 10) even for low sample mass, but samples dried in a microwave oven/stove and ground in a ball mill presented the best homogeneity.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The concentrations of Cu, Pb, Zn, Cr, Ni, Al, Mn and Fe were measured by atomic absorption spectrometry, of 19 topsoil samples collected in the Teresina city urban area to discriminate natural and anthropic contributions and identify possible sources of pollution. The average concentrations of Cu, Zn, Pb and Cr of the urban soils were 6.11, 8.56, 32.12 and 7,17 mg/kg-1, respectively. Statistical analysis techniques, such as principal component analysis (PCA) and hierarchical cluster analysis (HCA), were used to analyze the data. Mn, Ni and Cr levels were interpreted as natural contributions, whereas Pb, Zn and, in part, Cu were accounted for mainly by anthropic activities. High Pb levels were observed in the ancient avenues.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Residual CuSO4 was incorporated into the mass utilized for cement preparation. To a cement mass with 1:0.5:5 of cement, lime and sand to 0.25, 0.50, 0.75 and 1.00% of residual CuSO4 were added. The sulfate was mixed separately with lime and water to induce metal precipitation. The hardened test bodies were submerged in Milli-Q water for three months. No Cu was detected in the water by Atomic Absorption Spectrometry. The best proportion for mechanical resistance and porosity is 0.50%. The cement is adequate for non-structural objects.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Simple experiments are proposed for measuring molecular absorption of chromate and dichromate ions using an atomic absorption spectrometer. The experiments can help undergraduate students in instrumental analysis courses understand important aspects involving conceptual and instrumental similarities and differences between frequently used analytical techniques. Hollow cathode lamps were selected with wavelengths in the region of molecular absorption of chromate and dichromate. Calibration curves were obtained and the linear dynamic range was evaluated. Results were compared with those obtained in a molecular absorption spectrometer. The molar absorptivities obtained were also compared.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A simple and reliable ashing procedure is proposed for the preparation of used lubricating oil samples for the determination of Zn, Fe, Pb, Ni and Cu by the flame atomic absorption spectrometry technique. Sulphanilic acid was added to oil samples, the mixture coked and the coke ashed at 550 ºC. The solutions of the ash were analysed by flame AAS for these metals. The quantification limits were 38.250 µg g-1 for Zn, 4.550 µg g-1 for Fe, 1.562 µg g-1 for Pb, 1.450 µg g-1 for Ni, and 0.439 µg g-1 for Cu. The determinations, in lubricating oil, showed good precision and accuracy with recoveries between 90 and 110 %, indicating a negligible matrix effect in the experiments using addition of analyte, with relative standard deviation lower than 5%. The results for analysis of wastewater contamined by theses lubricants showed a very high relative standard deviation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Concentrations of Fe, Mn, Co, Cr, Zn and Cu were determinated using flame atomic absorption spectrometry in nine lichen species of the Sul-Mato-Grossense cerrado. The average metal ion concentrations varied in the following ranges: Fe, 248.41-1568.01; Mn, 98.50-397.33; Co, 10.08-24.81; Cr, 18.24-44.26; Zn, 14.62-34.79 and Cu, 3.23-7.57 mg kg-1. Statistical analysis (Pearson and Cluster) applied to the metal ion concentrations indicated that the accumulation of these ions can be due to several anthropogenic sources including agricultural activities, mineral exploration, biomass burning, soil mineral composition and leather tanning processes by chromium.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In terms of soil fertility, zinc is a micronutrient that is very important in the culture of soy, maize, rice and coffee, because it is a structural and functional component of a great number of enzymes. Therefore, diverse methods have been used to determine zinc in soil. In this work we use colorimetry as a methods of zinc determination in soil using two methodologies of sample digesting, H2SO4/H2O2 and HNO3/H2O2. In order to compare the results, atomic absorption spectrometry (AAS) was used. Results show that colorimetric methods can be used due to good sensitivity and reproducibility, since the zinc calibration curve showed good linearity. Comparing colorimetric methods with AAS we observed that the results were equivalent, as proven by the statistical values of the F and t of Student tests. Furthermore, both methods of soil digesting can be used, leading to a flexible methodology of low-cost for routine zinc analyses in soil.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This is a review of direct analysis using solid sampling graphite furnace atomic absorption spectrometry. Greater emphasis is dedicated to sample preparation, sample homogeneity, calibration and its application to microanalysis and micro-homogeneity studies. The main advantages and some difficulties related to the applicability of this technique are discussed. A literature search on the application of solid sampling graphite furnace atomic absorption spectrometry in trace element determination in many kinds of samples, including biological, clinical, technological and environmental ones, is also presented.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The study consists is the application of zeolites NaX, NaY and A as builder in detergent formulations to eliminate the hardness of water. Therefore, the adsorption of ions Ca+2 and Mg+2 were evaluated, and the effect of the cleaning action of the surfactant sodium dodecil sulfate (SDS) through tests of detergency. The experiments were conducted in bath system (with shaking) and quantification of metals was performed by atomic absorption spectrometry. Zeolite A showed the best results for adsorption of Ca++ and Mg++ with retention rates of around 90 and 70% respectively and acted positively on the action of cleaning the surfactant SDS.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work describes methods for the simultaneous determination of Cd and Pb by graphite furnace atomic absorption spectrometry and As by hydride generation atomic absorption spectrometry in Brazilian nuts. The samples (~ 0.300 g) were digested to clear solutions in a closed vessel microwave oven. The pyrolysis and atomization temperatures for simultaneous determinations of Cd and Pb were 1100 and 2100 °C, respectively, using 0.5% (w v-1) NH4H2PO4 + 0.03% (w v-1) Mg(NO3)2 as chemical modifier. The limits of detection (3Δ) were 3.8 μg kg-1 for As, 0.86 μg kg-1 for Cd and 13 μg kg-1 for Pb. The reliability of the entire procedures was confirmed by peach leaves (No. 1547 - NIST) certified reference material analysis and addition and recovery tests. The found concentrations presented no statistical differences at the 95% confidence level.