991 resultados para 10 specimens 250-350 µm
Resumo:
[EN] Gallotia simonyi (Steindachner, 1889) is a member of an endemic Canary Island genus and is among the largest of the approximately 250 recent species of lacertid lizards. Although Steindachner gave the locality of the types as the Roques de Salmor, off El Hierro island, previous workers (Urusaustegui, 1983; Manrique & Saavedra, 1873; Viera & Clavijo, 1983) and subsequent ones (Machado, 1985) regard the more western of the two rocks in the group, the Roque Chico de Salmor, as the actual source of material. The Roque Chico is 37 m high with a surface area of less than 10,000 m2 and lies 830 m from the northern coast of El Hierro (Machado, 1985).
Resumo:
Doctrina
Resumo:
The cerebral cysticercosis can produce intracranial hypertension by inflammatory obstruction of the basal cysterns or by expansive lesion in the cerebral parenchima or ventricular cavities. In the latter and in tumor cases the clinical picture is very similar and only after surgery can the etiology be determined. We present 11 operated cases of intracranial cysticercosis which presented the clinical picture of an expansive lesion. There were 7 females and 4 males with ages between 4 and 65 years. Nine patients were admitted because of headache, vomiting and visual disturbances suggestive of intracranial hypertension. One patient was admited with lymphocytic meningitis and another with focal seizures following hemiparesis. Five patients presented focal signs and six edema of the papilla. Epileptic manifestations were present in 45.5% of the cases. A plain X-ray films of the skull failed to reveal calcificatons, however signs of chronic hypertension were present in three cases. The electroencephalogram showed slow focal waves in 8 patients The spinal fluid examination revealed lymphocytosis in 4 cases, increased protein content in another 4 and complement fixation for cysticercosis was positive in 2 cases. The expansive lesions were localized by angiograph and ventriculography. In these the location was temporal in 4, frontal in 3, parietal in 2, in the third ventricle in one and in the fourth ventricle in another. At surgery we removed a large cyst from the cerebral parenchyma in six cases. Around the cyst a thick glial reaction was present. In the other cases the cyst was small but fixed to the ventricular trigone and produced dilatation of the inferior horn of the lateral ventricle. In two cases we removed a solitary intraventricular cyst from the third and fourth ventricles. In the two children operated upon there were several small hard cysts involving the cerebral parenchyma which displayed intense gliosis. There were no postoperative complications.
Resumo:
This study evaluated the fracture resistance of weakened roots restored with glass fiber posts, composite resin cores and complete metal crowns. Thirty maxillary canines were randomly divided into 3 groups of 10 teeth each: teeth without weakened roots (control); teeth with partially weakened roots (PWR) and teeth with and largely weakened roots (LWR). The control group was restored with glass fiber posts and a composite resin core. Teeth in the PWR and LWR groups were flared internally to standardized dimensions in order to simulate root weakness. Thereafter, the roots were partially filled with composite resin and restored in the same way as in the control group. The specimens were exposed to 250,000 cycles in a controlled chewing simulator. All intact specimens were subjected to a static load (N) in a universal testing machine at 45 degrees to the long axis of the tooth until failure. Data were analyzed by one-way ANOVA and Dunnett's test for multiple comparisons (p=0.05). There were statistically significant difference differences (p<0.01) among the groups (control group = 566.73 N; PWR = 409.64 N; and LWR = 410.91 N), with significantly higher fracture strength for the control group. There was no statistically significant difference (p>0.05) between the weakened groups. The results of this study showed that thicker root dentin walls significantly increase the fracture resistance of endodontically treated teeth.
Resumo:
The aim of this study was to analyze the shear bond strength between commercially pure titanium, with and without laser welding, after airbone-particle abrasion (Al2O3) and 2 indirect composites. Sixty-four specimens were cast and divided into 2 groups with and without laser welding. Each group was divided in 4 subgroups, related to Al2O3 grain size: A - 250 µm; B - 180 µm; C- 110 µm; and D - 50 µm. Composite rings were formed around the rods and light polymerized using UniXS unit. Specimens were invested and their shear bond strength at failure was measured with a universal testing machine at a crosshead speed of 2.0 mm/min. Statistical analysis was carried out with ANOVA and Tukey's test (α=0.05). The highest bond strength means were recorded in 250 µm group without laser welding. The lowest shear bond strength means were recorded in 50 µm group with laser welding. Statistically significant differences (p<0.05) were found between all groups. In conclusion, airborne particle abrasion yielded significantly lower bond strength as the Al2O3 particle size decreased. Shear bond strength decreased in the laser welded specimens.
Resumo:
OBJECTIVES: The purpose of this study was to assess the color change of three types of composite resins exposed to coffee and cola drink, and the effect of repolishing on the color stability of these composites after staining. MATERIALS AND METHODS: Fifteen specimens (15 mm diameter and 2 mm thick) were fabricated from microhybrid (Esthet-X; Dentsply and Filtek Z-250; 3M ESPE) and high-density hybrid (Surefil; Dentsply) composites, and were finished and polished with aluminum oxide discs (Sof-Lex; 3M ESPE). Color of the specimens was measured according to the CIE L*a*b* system in a refection spectrophotometer (PCB 6807; BYK Gardner). After baseline color measurements, 5 specimens of each resin were immersed in different staining solutions for 15 days: G1 - distilled water (control), G2 - coffee, G3 - cola soft drink. Afterwards, new color measurement was performed and the specimens were repolished and submitted to new color reading. Color stability was determined by the difference (ΔE) between the coordinates L*, a*, and b* obtained from the specimens before and after immersion into the solutions and after repolishing. RESULTS: There was no statistically signifcant difference (ANOVA, Tukey's test; p>0.05) among the ΔE values for the different types of composites after staining or repolishing. For all composite resins, coffee promoted more color change (ΔE>3.3) than distilled water and the cola soft drink. After repolishing, the ΔE values of the specimens immersed in coffee decreased to clinically acceptable values (ΔE<3.3), but remained signifcantly higher than those of the other groups. CONCLUSIONS: No signifcant difference was found among composite resins or between color values before and after repolishing of specimens immersed in distilled water and cola. Immersing specimens in coffee caused greater color change in all types of composite resins tested in this study and repolishing contributed to decrease staining to clinically acceptable ΔE values.
Resumo:
This study evaluated in vitro the pulp chamber temperature rise induced by the light-activated dental bleaching technique using different light sources. The root portions of 78 extracted sound human mandibular incisors were sectioned approximately 2 mm below the cementoenamel junction. The root cavities of the crowns were enlarged to facilitate the correct placing of the sensor into the pulp chamber. Half of specimens (n=39) was assigned to receive a 35% hydrogen peroxide gel on the buccal surface and the other halt (n=39) not to receive the bleaching agent. Three groups (n=13) were formed for each condition (bleach or no bleach) according to the use of 3 light sources recommended for dental bleaching: a light-emitting diode (LED)laser system, a LED unit and a conventional halogen light. The light sources were positioned perpendicular to the buccal surface at a distance of 5 mm and activated during 30 s. The differences between the initial and the highest temperature readings for each specimen were obtained, and, from the temperature changes, the means for each specimen and each group were calculated. The values of temperature rise were compared using Kruskal-Wallis test at 1% significance level. Temperature rise varied significantly depending on the light-curing unit, with statistically significant differences (p<0.01) among the groups. When the bleaching agent was not applied, the halogen light induced the highest temperature rise (2.38±0.66ºC). The LED unit produced the lowest temperature increase (0.29±0.13ºC); but there was no significant difference between LED unit and LED-laser system (0.35±0.15ºC) (p>0.01). When the bleaching agent was applied, there were significant differences among groups (p<0.01): halogen light induced the highest temperature rise (1.41±0.64ºC), and LED-laser system the lowest (0.33±0.12ºC); however, there was no difference between LED-laser system and LED unit (0.44±0.11ºC). LED and LED-laser system did not differ significantly from each other regardless the temperature rise occurred with or without bleaching agent application. It may be concluded that during light-activated tooth bleaching, with or without the bleaching agent, halogen light promoted higher pulp chamber temperature rise than LED unit and LED-laser system. The tested light-curing units provided increases in the pulp chamber temperature that were compatible with pulpal health.
Resumo:
Tooth shade results from the interaction between enamel color, enamel translucency and dentine color. A change in any of these parameters will change a tooth’s color. The objective of this study was to evaluate the changes occurring in enamel translucency during a tooth whitening process. Fourteen human tooth enamel fragments, with a mean thickness of 0.96 mm (± 0.3 mm), were subjected to a bleaching agent (10% carbamide peroxide) 8 hours per day for 28 days. The enamel fragment translucency was measured by a computer controlled spectrophotometer before and after the bleaching agent applications in accordance with ANSI Z80.3-1986 - American National Standard for Ophthalmics - nonprescription sunglasses and fashion eyewear-requirements. The measurements were statistically compared by the Mann-Whitney non-parametric test. A decrease was observed in the translucency of all specimens and, consequently, there was a decrease in transmittance values for all samples. It was observed that the bleaching procedure significantly changes the enamel translucency, making it more opaque.
Resumo:
This study evaluated the effect of specimens' design and manufacturing process on microtensile bond strength, internal stress distributions (Finite Element Analysis - FEA) and specimens' integrity by means of Scanning Electron Microscopy (SEM) and Laser Scanning Confocal Microscopy (LCM). Excite was applied to flat enamel surface and a resin composite build-ups were made incrementally with 1-mm increments of Tetric Ceram. Teeth were cut using a diamond disc or a diamond wire, obtaining 0.8 mm² stick-shaped specimens, or were shaped with a Micro Specimen Former, obtaining dumbbell-shaped specimens (n = 10). Samples were randomly selected for SEM and LCM analysis. Remaining samples underwent microtensile test, and results were analyzed with ANOVA and Tukey test. FEA dumbbell-shaped model resulted in a more homogeneous stress distribution. Nonetheless, they failed under lower bond strengths (21.83 ± 5.44 MPa)c than stick-shaped specimens (sectioned with wire: 42.93 ± 4.77 MPaª; sectioned with disc: 36.62 ± 3.63 MPa b), due to geometric irregularities related to manufacturing process, as noted in microscopic analyzes. It could be concluded that stick-shaped, nontrimmed specimens, sectioned with diamond wire, are preferred for enamel specimens as they can be prepared in a less destructive, easier, and more precise way.
Resumo:
A new species of the relatively poorly known Neotropical freshwater stingray genus Plesiotrygon Rosa, Castello & Thorson, 1987 is described from the main channel and smaller tributaries (Ríos Itaya and Pachitea) of the upper Amazon basin in Peru. The first specimen to be collected, however, was from much farther east in Rio Solimões in 1996, just down-river from Rio Purus (specimen unavailable for this study). Plesiotrygon nana sp. nov., is a very distinctive and unusually small species of freshwater stingray (Potamotrygonidae), described here mostly from three specimens representing different size classes and stages of sexual maturity. Plesiotrygon nana sp. nov., is distinguished from its only congener, P. iwamae Rosa, Castello & Thorson, 1987, by numerous unique features, including: dorsal coloration composed of very fine rosettes or a combination of spots and irregular ocelli; very circular disc and snout; very small and less rhomboidal spiracles; short snout and anterior disc region; narrow mouth and nostrils; denticles on dorsal tail small, scattered, not forming row of enlarged spines; adult and preadult specimens with significantly fewer tooth rows; fewer caudal vertebrae; higher total pectoral radials; very small size, probably not surpassing 250 mm disc length or width, males maturing sexually at around 180 mm disc length and 175 mm disc width; distal coloration of tail posterior to caudal stings usually dark purplish-brown; and features of the ventral lateral-line canals (hyomandibular canal very narrow, infraorbital and supraorbital canals not undulated, supraorbital and infraorbital loops small and narrow, supraorbital loop very short, not extending posteriorly to level of mouth, jugular and posterior infraorbital canals short, not extending caudally to first gill slits, subpleural loop very narrow posteriorly; absence of anterior and posterior subpleural tubules). To provide a foundation for the description of P. nana sp. nov., morphological variation in P. iwamae was examined based on all type specimens as well as newly collected and previously unreported material. Two specimens topotypic with the male paratype of P. nana sp. nov., referred to here as Plesiotrygon cf. iwamae, are also reported. Relationships of the new species to P. iwamae are discussed; further characters indicative of Plesiotrygon monophyly are proposed, but the genus may still not be valid. Plesiotrygon nana sp. nov., is commercialized with some regularity in the international aquarium trade from Iquitos (Peru), an alarming circumstance because nothing is known of its biology or conservation requirements.
Resumo:
The present catalogue lists the type specimes of 112 nominal " poneromorph" ant species housed in the Formicidae collection of the Hymenoptera laboratory, Museu de Zoologia da Universidade de São Paulo (MZSP). The catalogue includes types of Amblyoponinae, Ectatomminae, Heteroponerinae, Ponerinae, and Proceratiinae, that is, all poneromorph (sensu Bolton, 2003) but for the monotypic Paraponerinae, of which the collection bears no type specimens. We present here information on type categories (holotype, paratype, syntype, lectotype, and paralectotype), label data, nomenclatural changes since the original description and type specimens conservation status. At last we present indexes for the taxa names presented.
Resumo:
The present catalogue lists the "dorylomorph" ant types (Aenictinae: Aenictus; Cerapachyinae: Acanthostichus and Cerapachys; Ecitoninae: Eciton, Labidus, Neivamyrmex and Nomamyrmex; and Leptanilloidinae: Asphinctanilloides and Leptanilloides) housed in the Formicidae collection of the Hymenoptera laboratory, Museu de Zoologia da Universidade de São Paulo (MZSP), Brazil. In total, the collection includes types of 141 nominal species, of which 56 are still valid. The majority of types of dorylomorph species in the MZSP collection are syntypes (67 species), but there are as well 13 species represented by holotypes only, 17 by holotypes and paratypes, 43 species by paratypes only, and one species by a paralectotype. We record the label information, condition of the specimens, nomenclatural changes, type status, and provide indexes of the listed taxa.
Resumo:
This catalogue lists the type specimens of 37 species of Pseudomyrmecinae ants deposited in the Hymenoptera Formicidae collection of the Museu de Zoologia da Universidade de São Paulo, which holds types of the only two genera that occur in the Neotropics, Pseudomyrmex Lund and Myrcidris Ward. We record the label information, condition of the specimens, nomenclatural changes, type status, and provide an index of the listed taxa.
Resumo:
The Parque Estadual do Alto Ribeira (PETAR) with about 250 caves, in an Atlantic forest reserve, is an important ecotourist attraction in the Ribeira Valley, an endemic area of American cutaneous leishmaniasis (ACL). With the purpose of investigating Leishmania vector species bothersome to humans the sandfly fauna was identified and some of its ecological aspects in the Santana nucleus, captures were undertaken monthly with automatic light traps in 11 ecotopes, including caves, forests, a camping site and domiciliary environments, and on black and white Shannon traps, from January/2001 to December/2002. A total of 2,449 sandflies representing 21 species were captured. The highest values of abundance obtained in the captures with automatic light traps were for Psathyromyia pascalei and Psychodopygus ayrozai. A total of 107 specimens representing 13 species were captured on black (12 species) and white (6 species) Shannon traps set simultaneously. Psychodopygus geniculatus females predominated on the black (43.75%), and Psathyromyia lanei and Ps. ayrozai equally (32.4%) on the white. Nyssomyia intermedia and Nyssomyia neivai, both implicated in the transmission of ACL in the Brazilian Southeastern region, were also captured. Ny. intermedia predominated in the open camping area. Low frequencies of phlebotomines were observed in the caves, where Evandromyia edwardsi predominated Lutzomyia longipalpis, the main vector of the American visceral leishmaniasis, was aslo present. This is its most southernly reported occurrence in the Atlantic forest.
Resumo:
Objective: The biochemical alterations between inflammatory fibrous hyperplasia (IFH) and normal tissues of buccal mucosa were probed by using the FT-Raman spectroscopy technique. The aim was to find the minimal set of Raman bands that would furnish the best discrimination. Background: Raman-based optical biopsy is a widely recognized potential technique for noninvasive real-time diagnosis. However, few studies had been devoted to the discrimination of very common subtle or early pathologic states as inflammatory processes that are always present on, for example, cancer lesion borders. Methods: Seventy spectra of IFH from 14 patients were compared with 30 spectra of normal tissues from six patients. The statistical analysis was performed with principal components analysis and soft independent modeling class analogy cross-validated, leave-one-out methods. Results: Bands close to 574, 1,100, 1,250 to 1,350, and 1,500 cm(-1) (mainly amino acids and collagen bands) showed the main intragroup variations that are due to the acanthosis process in the IFH epithelium. The 1,200 (C-C aromatic/DNA), 1,350 (CH(2) bending/collagen 1), and 1,730 cm(-1) (collagen III) regions presented the main intergroup variations. This finding was interpreted as originating in an extracellular matrix-degeneration process occurring in the inflammatory tissues. The statistical analysis results indicated that the best discrimination capability (sensitivity of 95% and specificity of 100%) was found by using the 530-580 cm(-1) spectral region. Conclusions: The existence of this narrow spectral window enabling normal and inflammatory diagnosis also had useful implications for an in vivo dispersive Raman setup for clinical applications.