963 resultados para variance and coherence


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of 2 postpolymerization treatments on toothbrushing wear (weight loss) and surface roughness of 3 autopolymerized reline resins-Duraliner II (D) (Reliance Dental), Kooliner (K) (Coe Laboratories), and Tokuso Rebase Fast (T) (Tokuyama Dental)-and 1 heat-polymerized resin, Lucitone 550 (L) (Dentsply International). Materials and Methods: Specimens (40 x 10 x 2mm) of each material (n = 24) were prepared and divided into 3 groups: control (no postpolymerization treatment); water bath (immersion in water at 55°C); and microwave (microwave irradiation). Specimens were dried until constant weight was achieved and the surface roughness (Ra) was measured. Tests were performed in a toothbrush machine using 20,000 strokes of brushing at a weight of 200 g, with the specimens immersed in 1:1 dentifrice/water slurry. Specimens were reconditioned to constant weight and the weight loss (mg) and surface roughness were evaluated. Data were analyzed by 2-way analysis of variance and followed by Tukey test (α = .05). Results: In the control group, the weight loss of materials D and T was lower (P < .05) than that of L. No differences among materials were found after postpolymerization treatments (P > .05). The weight loss of material T (control = 0.5 mg) was significantly increased (P < .05) after postpolymerization treatments (water bath = 1.9 mg; microwave = 1.8 mg). For materials K and T, the toothbrushed surface roughness was higher (P < .05) after microwave and waterbath postpolymerization treatments. Material L showed increased surface roughness after microwave postpolymerization treatment. Conclusion: The toothbrushing wear resistance of L was not superior to the reline resins. The postpolymerization treatments did not improve the toothbrushing wear resistance of the materials and produced an increased surface roughness for materials L, K, and T.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to quantitatively evaluate the effect of 10% carbamide peroxide on the microhardness of pit and fissure sealant materials. Methods: Fluroshield, Vitroseal Alfa, and one unfilled (Clinpro) sealants were placed in Teflon matrices (4 mm in diameter by 2 mm in height) and polymerized for 40 seconds. A total of 20 specimens were prepared for each material, in which half were assigned as the control group (stored in artificial saliva and no bleaching treatment). For the remaining half, Clarigel Gold bleaching agent (10% carbamide peroxide) was placed over the specimen surface for 4 hours/day during 4 weeks. When specimens were not under bleaching treatment, they were kept in artificial saliva. Afterwards, specimens were subjected to Knoop microhardness testing using a 25-g load for 5 seconds. Five measurements were made on the sealants' surfaces and then calculated in Knoop hardness values. The data were statistically analyzed by two-way analysis of variance and Tukey's tests with a 5% confidence level. Results: The results of this in vitro study showed that the application of a carbamide peroxide-based bleaching material significantly affected the microhardness values of filled sealant materials. The bleaching agent did not affect the microhardness of the unfilled sealant. CLINICAL SIGNIFICANCE: The results of this in vitro study suggest that the bleaching agents altered the surface hardness of filled sealant restorative materials. This could possibly lead to increased wear and surface roughness. © 2006, Copyright the authors.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of this study was to evaluate the antimicrobial activity of different trademarks and compositions of gutta-percha points and calcium hydroxide pastes used in endodontic therapy. The evaluated material consisted of gutta-percha points containing calcium hydroxide (Roeko™), gutta-percha points containing chlorhexidine (Roeko™), two convencional gutta-percha points (Endo Points™ and Roeko™) and two calcium hydroxide pastes (Calen™ and Calen/PMCC™). Antimicrobial tests included five species of microorganisms: Escherichia coli (ATCC10538), Staphylococcus epidermidis (ATCC12228), Staphylococcus aureus (ATCC6538), Pseudomonas aeruginosa (ATCC27853), and Micrococcus luteus (ATCC9341). The Agar difusion method was employed. The plates were kept at room temperature for 2 h for prediffusion and then incubated at 37°C for 24 h. The triphenyltetrazolium chloride gel was added for optimization and the zones of inhibition were measured. Statistical evaluation was carried out using analysis of variance and Tukey Test. The obtained results showed that all microbial species used in the study were inhibited by the gutta-percha points containing chlorhexidine and by the calcium hydroxide pastes (Calen™ and Calen/ PMCC™), with similar results (p > 0.05). No antimicrobial activity was observed for the other groups. It was concluded that the gutta-percha points containing chlorhexidine presented antimicrobial activity, whereas the gutta-percha points containing calcium hydroxide did not.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the influence of cavity design and photocuring method on the marginal seal of resin composite restorations. METHOD AND MATERIALS: Seventy-two bovine teeth were divided into 2 groups: group 1 received box-type cavity preparations, and group 2 received plate-type preparations. Each group was divided into 3 subgroups. After etching and bonding, Z250 resin composite (3M Espe) was applied in 2 equal increments and cured with 1 of 3 techniques: (1) conventional curing for 30 seconds at 650 mW/cm2; (2) 2-step photocuring, in which the first step was performed 14 mm from the restoration for 10 seconds at 180 mW/cm2 and the second step was performed in direct contact for 20 seconds at 650 mW/cm2; or (3) progressive curing using Jetlite 4000 (J. Morita) for 8 seconds at 125 mW/cm2 and then 22 seconds at 125 mW/cm2 up to 500 mW/cm2. The specimens were thermocycled for 500 cycles and then submitted to dye penetration with a 50% silver nitrate solution. Microleakage was assessed using a stereomicroscope. Data were analyzed using analysis of variance and Tukey test (5% level of significance). RESULTS: A statistically significant difference was found between groups when a double interaction between photocuring and cavity preparation was considered (P = .029). CONCLUSIONS: No one type of cavity preparation or photocuring method prevented micro-leakage. The plate-type preparation showed the worst dye penetration when conventional and progressive photocuring methods were used. The best results were found using the 2-step photocuring with the plate-type preparation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: This study evaluated the efficiency of repolishing, sealing with surface sealant, and the joining of both in decreasing the surface roughness of resin-based composites after a toothbrushing process. METHOD AND MATERIALS: Ten specimens of each composite (Alert, Z100, Definite, and Prodigy Condensable), measuring 2 mm in thickness and 4 mm in diameter, were made and submitted to finishing and polishing processes on both sides of the specimens using the Sof-Lex system. The specimens were then subjected to toothbrushing (30,000 cycles), and surface roughness (Ra) was analyzed with a Surfcorder SE 1700 profilometer. The upper surface of each composite was etched with 37% phosphoric acid, and the surface-penetrating sealant Protect-it was applied on 1 surface. The roughness of these surfaces was again measured. On the other side, the surface of the specimen was repolished, and the efficiency of this procedure was measured using the profilometer. The surface roughness resulting from the joining of the 2 methods was verified by applying, in the final stage, the surface-penetrating sealant on the repolished surface. Data were analyzed with analysis of variance and Tukey test (P <.05). RESULTS: Results showed that the lowest surface roughness values were obtained for Definite, Z100, and Prodigy Condensable after the repolishing process and after the repolishing plus sealing. For Alert, the joining of repolishing plus sealing promoted the lowest values of surface roughness. CONCLUSION: Of the resin-based composites, Alert demonstrated the highest values of surface roughness in all the techniques tested.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study evaluated the surface microhardness and fluoride release of 5 restorative materials - Ketac-Fil Plus, Vitremer, Fuji II LC, Freedom and Fluorofil - in two storage media: distilled/deionized water and a pH-cycling (pH 4.6). Twelve specimens of each material, were fabricated and the initial surface microhardness (ISM) was determined in a Shimadzu HMV-2000 microhardness tester (static load Knoop). The specimens were submitted to 6- or 18-h cycles in the tested media. The solutions were refreshed at the end of each cycle. All solutions were stored for further analysis. After 15-day storage, the final surface microhardness (FSM) and fluoride release were measured. Fluoride dose was measured with a fluoride-specific electrode (Orion 9609-BN) and digital ion analyzer (Orion 720 A). The variables ISM, FSM and fluoride release were analyzed statistically by analysis of variance and Tukey's test (p<0.05). There was significant difference in FSM between the storage media for Vitremer (pH 4.6 = 40.2 ± 1.5; water = 42.6 ± 1.4), Ketac-Fil Plus (pH 4.6 = 73.4 ± 2.7; water = 58.2 ± 1.3) and Fluorofil (pH 4.6 = 44.3 ± 1.8; water = 38.4 ± 1.0). Ketac-Fil Plus (9.9 ± 18.0) and Fluorofil (4.4 ± 1.3) presented higher fluoride release in water, whereas Vitremer (7.4 ± 7.1), Fuji II LC (5.7 ± 4.7) and Freedom (2.1 ± 1.7) had higher fluoride release at pH 4.6. Microhardness and fluoride release of the tested restorative materials varied according to the storage medium.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: Symmetry is one of the factors that contributes to facial harmony, and in oral rehabilitation it determines the success of esthetic treatment. Therefore, the aim of the present study was to analyze the axial symmetry between the bipupillar midline and maxillary central incisors midline of 102 dental students (both genders) distributed across five Brazilian dental schools. Materials and Methods: Students with no teeth missing and who had never been subjected to any dental treatment were selected. Photographs were taken with a Dental Eye III camera with a 100-mm macro objective and ratio of 1 : 10 from natural size, recorded on an Ektachrome ASA/ISO 100 film. The images were developed and applied to Microsoft Office Power Point 2007 software. The results were analyzed by analysis of variance and Student's t-test (= 0.05). Results: There was no significant correlation between bipupillar midline and the maxillary dental midline, irrespective of gender. Conclusion: No significant coincidence was observed between the interpupillary and dental midline. However, the interpupillar distance and its relationship with other anatomic structures may be used as a reference in treatment, but measurements must be assessed individually. CLINICAL SIGNIFICANCE Anatomic measurements and facial proportions can be helpful during the planning of esthetic oral rehabilitation. © 2009 Wiley Periodicals, Inc.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the effect of pre-heating resin composite photo-cured with light-curing units (LCU) by FT-IR. Twenty specimens were made in a metallic mold (4 mm diameter × 2 mm thick) from composite resin-Tetric Ceram® (Ivoclar/Vivadent) at room temperature (25°C) and pre-heated to 37, 54, and 60°C. The specimens were cured with halogen curing light (QTH) and light emitted by diodes (LED) during 40 s. Then, the specimens were pulverized, pressed with KBr and analyzed with FT-IR. The data were submitted to statistical analysis of variance and Kruskal-Wallis test. Study data showed no statistically significant difference to the degree of conversion for the different light curing units (QTH and LED) (p > 0.05). With the increase of temperature there was significant increase in the degree of conversion (p < 0.05). In this study were not found evidence that the light curing unit and temperature influenced the degree of conversion. © 2010 Pleiades Publishing, Ltd.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effectiveness of 3 solvents (eucalyptol, orange oil, and xylol) on 2 types of gutta-percha (conventional and thermoplastic) and Resilon. Specimens (10 mm diameter × 1 mm thick; n=7 per condition) were prepared and maintained at 37°C for 48 h. Each specimen was weighed on a precision scale every 24 h until its mass was stable, at which time the initial mass was determined. Specimens (n=7) were then immersed in the solvent solutions and, after 48 h at 37°C, they were reweighed at 24- h intervals, until stabilization (final mass). The difference between the final and the initial mass determined the solvent capacity of each solvent. Data were subjected to analysis of variance and Tukey's test at 5% significance level. The results demonstrated that xylol was the most effective, especially on conventional gutta-percha and Resilon (p<0.05). Eucalyptol and orange oil were more effective on thermoplastic gutta-percha than the other materials (p<0.05). It was concluded that all evaluated substances presented solvent action, but xylol was the most effective on both gutta-percha or Resilon.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of the present study was to evaluate white blood cell counts and serum protein profiles of commercial layers experimentally infected with Salmonella Gallinarum (SG) in order to better understand the pathophysiology of the disease caused by this bacterium. 180 five-day-old commercial layers were divided into 3 groups (G); G1 and G2 received 0.2 mL of inoculate containing 3.3x10 8 CFU or 3.3×10 5 CFU SG resistant to nalidix acid (Nal r)/mL, respectively, directly into their crops. G3 group did not receive the inoculum. Birds were sacrificed 24 hours before (T1) and 24 hours after the infection (T2), and three (T3), five (T4), seven (T5), and ten (T6) days after the administration of the inoculum. White blood cell counts were carried out in a Neubauer hemocytometer and in blood smears. Serum protein concentrations, including acute-phase proteins, were determined using sodium dodecyl sulphate-polyacrylamide gel electrophoresis (SDS-PAGE). Data were submitted to analysis of variance, and means were compared by Tukey's test (P <0.05). G1 and G2 groups presented higher leukocyte counts on T4 and T5, respectively, due to the increase of circulating lymphocytes and heterophils, with a significant difference relative to G3. In electrophoresis, an increase in the serum levels of ceruloplasmin, haptoglobin, and hemopexin and a decrease in transferrin, which are acute-phase proteins, was verified. IgA serum levels did not change; however, IgG concentration increased during the infection. In conclusion, the results provide information for the better understanding of the pathophysiology of fowl typhoid.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study was undertaken to investigate the expression of p53, Ki-67, and CD31 proteins in endometrial polyps of postmenopausal women treated with tamoxifen (TAM). Postmenopausal women with endometrial polyps treated with TAM (n = 20), postmenopausal women with endometrial polyps without hormone use (n = 20), postmenopausal women with atrophic endometrium (n = 20), and postmenopausal women with endometrial adenocarcinoma (n = 20) were prospectively investigated. Tissue samples were immunohistochemically evaluated by monoclonal antibodies for p53, Ki-67, and CD31. The data were analyzed using the Student t test, analysis of variance, and χ2 to evaluate significant differences between the groups. The level of significance was set at P < 0.05. There was no difference in the expression of p53 between the groups (P = 0.067). The expression of Ki-67 was higher in the polyp samples from TAM-treated women compared with those from the women using no hormone (P = 0.0047) and those from the women with atrophic endometrium (P = 0.008). Samples from the women with endometrial cancer was associated with higher Ki-67 expression compared with the polyp samples from TAM-treated women (P = 0.004). The expression of CD31 was higher in the polyp samples of TAM-treated women compared with that of the samples from the women with atrophic endometrium (P < 0.001) and similar to the polyp samples from the women using no hormone (P = 0.319) and to the samples from the women with endometrial cancer (P = 0.418). The use of TAM in postmenopausal women might be associated with increased cellular proliferation in endometrial polyps without interfering angiogenesis or inactivation of tumor suppressor proteins.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The objective of this study was to determine whether there is a genotype by environment interaction (GxE) for dairy buffaloes in Brazil and Colombia. The (co)variance components were estimated by using a bi-trait repeatability animal model with the REML method. Each trait consisted in the milk yield obtained in both countries. Contemporary group (herd, year and season of parity) and age at parity (linear and quadratic covariate) fixed effects, along with the additive genetic, permanent environment, and the residual random effects were included in the model. Genetic, permanent environmental and residual variance and heritabilities were different for both countries. The genetic correlations for milk yield between Brazil and Colombia were low (between 0.10 and 0.13), indicating a GxE interaction between both countries. Knowing that this interaction influences the genetic progress of buffalo populations in Brazil and Colombia, we recommend choosing sires tested in the country they will be used, along with conducting joint genetic evaluations that consider GxE interaction effects.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Orbifloxacin is a fluoroquinolone with broad-spectrum antimicrobial activity, and belongs to the third generation of quinolones. Regarding the quality control of medicines, a validated microbiological assay for determination of orbifloxacin in pharmaceutical formulations has not as yet been reported. For this purpose, this paper reports the development and validation of a simple, sensitive, accurate and reproducible agar diffusion method to quantify orbifloxacin in tablet formulations. The assay is based on the inhibitory effect of orbifloxacin upon the strain of Staphylococcus aureus ATCC 25923 used as test microorganism. The results were treated statistically by analysis of variance and were found to be linear (r = 0.9992) in the selected range of 16.0-64.0 μg/mL, precise with relative standard deviation (RSD) of repeatability intraday = 2.88%, intermediate precision RSD = 3.33%, and accurate (100.31%). The results demonstrated the validity of the proposed bioassay, which allows reliable orbifloxacin quantitation in pharmaceutical samples and therefore can be used as a useful alternative methodology for the routine quality control of this medicine. © 2011 by the authors; licensee MDPI, Basel, Switzerland.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Introduction: The aim of this study was to evaluate the pH, calcium ion release, setting time, and solubility of white mineral trioxide aggregate (WMTA) and white Portland cement (WPC) combined with the following radiopacifying agents: bismuth oxide (BO), calcium tungstate (CT), and zirconium oxide (ZO). Methods: Fifty acrylic teeth with root-end filling material were immersed in ultrapure water for measurement of pH and calcium release (atomic absorption spectrophotometry) at 3, 24, 72, and 168 hours. For evaluation of setting time, each material was analyzed according to the American Society for Testing and Materials guidelines 266/08. The solubility test was performed according to American National Standards Institute/American Dental Association specification no. 57/2000. Solubility, setting time, and pH values were compared by using analysis of variance and Tukey test, and the values of calcium release were compared by the Kruskal-Wallis and Miller tests. The significance level was set at 5%. Results: The pH and calcium release were higher at 3 and 24 hours. WPC was the material with the higher values for both properties. WMTA had the greatest solubility among all materials (P <.05). All radiopacifiers increased the setting time of WPC, and WMTA had the shortest setting time among all materials (P < .05). Conclusions: All materials released calcium ions. Except for WPC/CT at 168 hours, all materials promoted an alkaline pH. On the basis of the obtained results, ZO and CT can be considered as potential radiopacifying agents to be used in combination with Portland cement. Copyright © 2012 American Association of Endodontists.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Ceftriaxone sodium is a cephalosporin with broad-spectrum antimicrobial activity and belongs to the third generation of cephalosporins. Regarding the quality control of medicines, a validated microbiological assay for the determination of ceftriaxone sodium in powder for injectable solution has not been reported yet. This paper reports the development and validation of a simple, accurate and reproducible agar diffusion method to quantify ceftriaxone sodium in powder for injectable solution. The assay is based on the inhibitory effect of ceftriaxone sodium on the strain of Bacillus subtilis ATCC 9371 IAL 1027 used as test microorganism. The results were treated statistically by analysis of variance and were found to be linear (r = 0.999) in the selected range of 15.0-60.0 μg/mL, precise with a relative standard deviation (RSD) of repeatability intraday = 1.40%, accurate (100.46%) and robust with a RSD lower than 1.28%. The results demonstrated the validity of the proposed bioassay, which allows reliable ceftriaxone sodium quantitation in pharmaceutical samples and therefore can be used as a useful alternative methodology for the routine quality control of this medicine. © 2012 by the authors; licensee MDPI, Basel, Switzerland.