995 resultados para variable intensity
Resumo:
Background More individuals are now being identified with very rare genetic syndromes. We present a family with an inherited duplication of 16p11.2 to 16q12.1 in ring formation. Three of the four children, (aged 15 months to 10 years), mother, uncle, and grandmother are affected. Our aim was to provide preliminary evidence of possible phenotypic patterns of learning and behaviour associated with this chromosome anomaly. Method Psychometric assessments were undertaken with all four children. The mother and uncle also agreed to participate in the study. Measures of development (Bayley or Mullen), intellectual ability (WISC-IV or WAIS-III), academic achievement (WIAT-II), adaptive behaviour (Vinelands), and other relevant aspects of functioning (e.g., Children’s Memory Scale) were administered. Results. The first-born child is the only one who is unaffected. Her intellectual ability was assessed as being within the superior range. The second child experienced early difficulties with speech and motor skills. Although his intelligence is average, he has learning difficulties and significant auditory memory problems. The third child’s speech and motor milestones were markedly delayed. He has a complex medical history that includes a vitamin B12 deficiency. On the Mullen Scales at age 4 his scores ranged from average to very low. The development of the youngest child (aged 15 months), who also had a B12 deficiency but was treated early, was assessed as being within typical limits. Conclusions There is considerable developmental variability among the three children with this inherited 16p duplication. We discuss the intriguing similarities and differences, considering common features that may reflect phenotypic patterns and speculating about possible explanations for the variable presentations.
Resumo:
Background: Individuals who fear falling may restrict themselves from performing certain activities and may increase their risk of falling. Such fear, reflected in the form of falls efficacy, has been measured in only a small number of studies measuring the effectiveness of exercise interventions in the elderly. This may be due to the various types of exercise that can be performed. Hence the effectiveness of exercise on falls efficacy is relatively understudied. Therefore, there is a need to measure falls efficacy as an outcome variable when conducting exercise interventions in the elderly. Methods: A total of 43 elderly community-dwelling volunteers were recruited and randomly allocated to a conventional exercise intervention, a holistic exercise intervention, or a control group. The interventions were performed 2 days per week for 10 weeks. Falls efficacy was measured at baseline and at the completion of the interventions using the Modified Falls Efficacy Scale (MFES). Results: Within group comparisons between baseline and follow-up indicated no significant improvements in falls efficacy, however, the difference for the conventional exercise group approached statistical significance (baseline 8.9 to follow-up 9.3; P = 0.058). Within group comparisons of mean difference MFES scores showed a significant difference between the conventional exercise group and the control group (conventional exercise group 0.4 vs control group −0.6; P < 0.05). Conclusion: Given the lack of significant improvements in falls efficacy found for any of the groups, it cannot be concluded whether a conventional or a holistic exercise intervention is the best approach for improving falls efficacy. It is possible that the characteristics of the exercise interventions including specificity, intensity, frequency and duration need to be manipulated if the purpose is to bring about improvements in falls efficacy.
Resumo:
Purpose/Objectives: To examine peak volume of oxygen consumption (VO2peak) changes after a high- or low-intensity exercise intervention. Design: Experimental trial comparing two randomized intervention groups with control. Setting: An exercise clinic at a university in Australia. Sample: 87 prostate cancer survivors (aged 47–80 years) and 72 breast cancer survivors (aged 34–76 years). Methods: Participants enrolled in an eight-week exercise intervention (n = 84) or control (n = 75) group. Intervention participants were randomized to low-intensity (n = 44, 60%–65% VO2peak, 50%–65% of one repetition maximum [1RM]) or high-intensity (n = 40, 75%–80% VO2peak, 65%–80% 1RM) exercise groups. Participants in the control group continued usual routines. All participants were assessed at weeks 1 and 10. The intervention groups were reassessed four months postintervention for sustainability. Main Research Variables: VO2peak and self-reported physical activity. Findings: Intervention groups improved VO2peak similarly (p = 0.083), and both more than controls (p < 0.001). The high-intensity group maintained VO2peak at follow-up, whereas the low-intensity group regressed (p = 0.021). The low-intensity group minimally changed from baseline to follow-up by 0.5 ml/kg per minute, whereas the high-intensity group significantly improved by 2.2 ml/kg per minute (p = 0.01). Intervention groups always reported similar physical activity levels. Conclusions: Higher-intensity exercise provided more sustainable cardiorespiratory benefits than lower-intensity exercise. Implications for Nursing: Survivors need guidance on exercise intensity, because a high volume of low-intensity exercise may not provide sustained health benefits.
Resumo:
A two-dimensional variable-order fractional nonlinear reaction-diffusion model is considered. A second-order spatial accurate semi-implicit alternating direction method for a two-dimensional variable-order fractional nonlinear reaction-diffusion model is proposed. Stability and convergence of the semi-implicit alternating direct method are established. Finally, some numerical examples are given to support our theoretical analysis. These numerical techniques can be used to simulate a two-dimensional variable order fractional FitzHugh-Nagumo model in a rectangular domain. This type of model can be used to describe how electrical currents flow through the heart, controlling its contractions, and are used to ascertain the effects of certain drugs designed to treat arrhythmia.
Resumo:
It is commonly accepted that regular moderate intensity physical activity reduces the risk of developing many diseases. Counter intuitively, however, evidence also exists for oxidative stress resulting from acute and strenuous exercise. Enhanced formation of reactive oxygen and nitrogen species may lead to oxidatively modified lipids, proteins and nucleic acids and possibly disease. Currently, only a few studies have investigated the influence of exercise on DNA stability and damage with conflicting results, small study groups and the use of different sample matrices or methods and result units. This is the first review to address the effect of exercise of various intensities and durations on DNA stability, focusing on human population studies. Furthermore, this article describes the principles and limitations of commonly used methods for the assessment of oxidatively modified DNA and DNA stability. This review is structured according to the type of exercise conducted (field or laboratory based) and the intensity performed (i.e. competitive ultra/endurance exercise or maximal tests until exhaustion). The findings presented here suggest that competitive ultra-endurance exercise (>4h) does not induce persistent DNA damage. However, when considering the effects of endurance exercise (<4h), no clear conclusions could be drawn. Laboratory studies have shown equivocal results (increased or no oxidative stress) after endurance or exhaustive exercise. To clarify which components of exercise participation (i.e. duration, intensity and training status of subjects) have an impact on DNA stability and damage, additional carefully designed studies combining the measurement of DNA damage, gene expression and DNA repair mechanisms before, during and after exercise of differing intensities and durations are required.
Resumo:
Objetivo Establecer una posible relación entre la fuerza (Jamar), el dolor (EVA) y la capacidad funcional referida por el paciente (DASH) determinando en qué grado influyen unas en otras. Estudio observacional transversal analítico. Participantes Muestra de 72 pacientes que presentaban una artrosis trapecio metacarpiana grado 2-3 de Eaton. Los pacientes fueron reclutados cuando acudían a la Unidad de Cirugía de mano. Método Se realizaron mediciones de fuerza de agarre, pinza, valoración del dolor y funcionalidad, y se establecieron las correlaciones entre cada una de ellas. Resultados El modelo más significativo para la función (R2 =0.83) incluye la variable dolor y la fuerza. Pero es la fuerza punta contra punta la que presenta una mayor correlación con el cuestionario DASH (B-estandarizado: –57). Respecto al dolor, influye en todas las mediciones de fuerza realizadas con el dinamómetro, siendo también la fuerza de la pinza punta contra punta la que presenta una mayor correlación. Conclusiones Los hallazgos corroboran que existe una correlación significativa entre la función referida por el paciente y variables que podemos medir en consulta, como la fuerza del puño y la pinza. Pero también esta correlación es significativa entre las variables función y dolor entre sí, pero es la pinza punta contra punta la que presenta una mayor asociación con el cuestionario DASH. Abstract in English Objective To assess the relationship between muscle strength (Jama), and pain (VAS) levels with hand function (DASH) in patients with trapeziometarcapal osteoarthritis. Cross-sectional study. Participants Sample of 72 patients with osteoarthritis stage 2-3 (Eaton) and trapeziometacarpal osteoarthritis. Patients were recruited when they came to the Hand Surgery Unit. Method Grip strength, pinch, pain and hand function were measured, and correlation and regression coefficients between them were obtained. Results For function, the most significant model (R2 = 0.83) included pain and strength. But it is tip to tip pinch force which has a stronger relationship with DASH (Standardized B: –57) questionnaire. Pain also influenced strength measured with the dynamometer but it was tip to tip pinch force that was the most affected. Conclusions Findings confirm that there is a significant correlation between function referred by the patient and variables that can be measured in the clinic such as grip strength and pinch. The correlation between pain intensity and function was also significant, but tip to tip pinch strength had the greatest impact on the function.
Resumo:
This research investigated the use of DNA fingerprinting to characterise the bacteria Streptococcus pneumoniae or pneumococcus, and hence gain insight into the development of new vaccines or antibiotics. Different bacterial DNA fingerprinting methods were studied, and a novel method was developed and validated, which characterises different cell coatings that pneumococci produce. This method was used to study the epidemiology of pneumococci in Queensland before and after the introduction of the current pneumococcal vaccine. This study demonstrated that pneumococcal disease is highly prevalent in children under four years, that the bacteria can `switch' its cell coating to evade the vaccine, and that some DNA fingerprinting methods are more discriminatory than others. This has an impact on understanding which strains are more prone to cause invasive disease. Evidence of the excellent research findings have been published in high impact internationally refereed journals.
Resumo:
Abstract PURPOSE: Compensatory responses may attenuate the effectiveness of exercise training in weight management. The aim of this study was to compare the effect of moderate- and high-intensity interval training on eating behavior compensation. METHODS: Using a crossover design, 10 overweight and obese men participated in 4-week moderate (MIIT) and high (HIIT) intensity interval training. MIIT consisted of 5-min cycling stages at ± 20% of mechanical work at 45%VO(2)peak, and HIIT consisted of alternate 30-s work at 90%VO(2)peak and 30-s rests, for 30 to 45 min. Assessments included a constant-load exercise test at 45%VO(2)peak for 45 min followed by 60-min recovery. Appetite sensations were measured during the exercise test using a Visual Analog Scale. Food preferences (liking and wanting) were assessed using a computer-based paradigm, and this paradigm uses 20 photographic food stimuli varying along two dimensions, fat (high or low) and taste (sweet or nonsweet). An ad libitum test meal was provided after the constant-load exercise test. RESULTS: Exercise-induced hunger and desire to eat decreased after HIIT, and the difference between MIIT and HIIT in desire to eat approached significance (p = .07). Exercise-induced liking for high-fat nonsweet food tended to increase after MIIT and decreased after HIIT (p = .09). Fat intake decreased by 16% after HIIT, and increased by 38% after MIIT, with the difference between MIIT and HIIT approaching significance (p = .07). CONCLUSIONS: This study provides evidence that energy intake compensation differs between MIIT and HIIT.
Resumo:
Many physical processes appear to exhibit fractional order behavior that may vary with time and/or space. The continuum of order in the fractional calculus allows the order of the fractional operator to be considered as a variable. In this paper, we consider a new space–time variable fractional order advection–dispersion equation on a finite domain. The equation is obtained from the standard advection–dispersion equation by replacing the first-order time derivative by Coimbra’s variable fractional derivative of order α(x)∈(0,1]α(x)∈(0,1], and the first-order and second-order space derivatives by the Riemann–Liouville derivatives of order γ(x,t)∈(0,1]γ(x,t)∈(0,1] and β(x,t)∈(1,2]β(x,t)∈(1,2], respectively. We propose an implicit Euler approximation for the equation and investigate the stability and convergence of the approximation. Finally, numerical examples are provided to show that the implicit Euler approximation is computationally efficient.
Resumo:
Introduction β-alanine (BAl) and NaHCO3 (SB) ingestion may provide performance benefits by enhancing concentrations of their respective physiochemical buffer counterparts, muscle carnosine and blood bicarbonate, counteracting acidosis during intense exercise. This study examined the effect of BAl and SB co-supplementation as an ergogenic strategy during high-intensity exercise. Methods Eight healthy males ingested either BAl (4.8 g day−1 for 4 weeks, increased to 6.4 g day−1 for 2 weeks) or placebo (Pl) (CaCO3) for 6 weeks, in a crossover design (6-week washout between supplements). After each chronic supplementation period participants performed two trials, each consisting of two intense exercise tests performed over consecutive days. Trials were separated by 1 week and consisted of a repeated sprint ability (RSA) test and cycling capacity test at 110 % Wmax (CCT110 %). Placebo (Pl) or SB (300 mg kgbw−1) was ingested prior to exercise in a crossover design to creating four supplement conditions (BAl-Pl, BAl-SB, Pl–Pl, Pl-SB). Results Carnosine increased in the gastrocnemius (n = 5) (p = 0.03) and soleus (n = 5) (p = 0.02) following BAl supplementation, and Pl-SB and BAl-SB ingestion elevated blood HCO3 − concentrations (p < 0.01). Although buffering capacity was elevated following both BAl and SB ingestion, performance improvement was only observed with BAl-Pl and BAl-SB increasing time to exhaustion of the CCT110 % test 14 and 16 %, respectively, compared to Pl–Pl (p < 0.01). Conclusion Supplementation of BAl and SB elevated buffering potential by increasing muscle carnosine and blood bicarbonate levels, respectively. BAl ingestion improved performance during the CCT110 %, with no aggregating effect of SB supplementation (p > 0.05). Performance was not different between treatments during the RSA test.
Resumo:
This study compared fat oxidation rate from a graded exercise test (GXT) with a moderate-intensity interval training session (MIIT) in obese men. Twelve sedentary obese males (age 29 ± 4.1 years; BMI 29.1 ± 2.4 kg·m-2; fat mass 31.7 ± 4.4 %body mass) completed two exercise sessions: GXT to determine maximal fat oxidation (MFO) and maximal aerobic power (VO2max), and an interval cycling session during which respiratory gases were measured. The 30-min MIIT involved 5-min repetitions of workloads 20% below and 20% above the MFO intensity. VO2max was 31.8 ± 5.5 ml·kg-1·min-1 and all participants achieved ≥ 3 of the designated VO2max test criteria. The MFO identified during the GXT was not significantly different compared with the average fat oxidation rate in the MIIT session. During the MIIT session, fat oxidation rate increased with time; the highest rate (0.18 ± 0.11 g·min- 1) in minute 25 was significantly higher than the rate at minute 5 and 15 (p ≤ 0.01 and 0.05 respectively). In this cohort with low aerobic fitness, fat oxidation during the MIIT session was comparable with the MFO determined during a GXT. Future research may consider if the varying workload in moderate-intensity interval training helps adherence to exercise without compromising fat oxidation.
Resumo:
The correlation between magnetic and transport properties is examined by studying poly(4,4'-methylenedianiline)(PMDA) salts and their bases using EPR and conductivity measurements. Five different PMDA salts (doped polymers)were prepared by chemical polymerization of 4,4'-methylenedianiline using different protonic acids. The PMDA bases were obtained by dedoping the salts using ammonium hydroxide. Ambient temperature electrical conductivity measurements show evidence for the doped PMDA system to be highly disordered. The EPR spectra of the samples were recorded in the range 20-200 "C, and the results were analyzed on the basis of the polaron-bipolaron model, which is typical of nondegenerate systems. Both PMDA salts and their bases consist of self-trapped, highly mobile polarons or radical cations. EPR studies on PMDA salts show evidence for the presence of thermally activated and temperature independent (or Pauli type) paramagnetism while the bases show thermally activated, Pauli and Curie-Weiss types of paramagnetism. The paramagnetism arises due to polarons.It is proposed that charge transport takes place through both polarons and bipolarons.
Resumo:
A time-dependent quantum mechanical (TDQM) method of wavepacket propagation in computing resonance Raman intensities for polyatomic systems, has been developed and demonstrated by applying it tocis-stilbene andtrans-azobenzene. In the case of the former, Raman excitation profiles (REPs) for the various vibrational modes have also been computed. It is observed that the calculated absorption spectrum and the REPs compare very well with the experimental results. A comparison of these results with those of the often semiclassical approach reveals that the TDQM method can be used to study polyatomic systems with as much ease as the semiclassical wavepacket method.
Resumo:
This paper presents experimental and computational results of oxy-fuel burner operating on classical flame and lameless mode for heat release rate of 26 kW/m3. The uniqueness of the burner arises from a slight asymmetric injection of oxygen at near sonic velocities. Measurements of emperature, species, total heat flux, radiative heat flux and NOx emission were carried out inside the furnace and the flow field was computationally analyzed. The flame studies were carried out for coaxial flow of oxygen and fuel jets with similar inlet velocities. This configuration results in slow mixing between fuel and oxygen and the flame is developed at distance away from the burner and the flame is bright/white in colour. In the flameless mode a slight asymmetric injection of the high velocity oxygen jet leads to a large asymmetric recirculation pattern with the recirculation ratio of 25 and the resulting flame is weak bluish in colour with little soot and acetylene formation. The classical flame in comparison is characterised by soot and acetylene formation, higher NOx and noise generation. The distribution of temperature and heat flux in the furnace is more uniform with flameless mode than with flame mode.