925 resultados para turf visual quality


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of the present study was to optimize a radiographic technique for hand examinations using a computed radiography (CR) system and demonstrate the potential for dose reductions compared with clinically established technique. An exposure index was generated from the optimized technique to guide operators when imaging hands. Homogeneous and anthropomorphic phantoms that simulated a patient's hand were imaged using a CR system at various tube voltages and current settings (40-55 kVp, 1.25-2.8 mAs), including those used in clinical routines (50 kVp, 2.0 mAs) to obtain an optimized chart. The homogeneous phantom was used to assess objective parameters that are associated with image quality, including the signal difference-to-noise ratio (SdNR), which is used to define a figure of merit (FOM) in the optimization process. The anthropomorphic phantom was used to subjectively evaluate image quality using Visual Grading Analysis (VGA) that was performed by three experienced radiologists. The technique that had the best VGA score and highest FOM was considered the gold standard (GS) in the present study. Image quality, dose and the exposure index that are currently used in the clinical routine for hand examinations in our institution were compared with the GS technique. The effective dose reduction was 67.0%. Good image quality was obtained for both techniques, although the exposure indices were 1.60 and 2.39 for the GS and clinical routine, respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To determine whether the improvement in intermediate vision after bilateral implantation of an aspheric multifocal intraocular lens (IOL) with a +3.00 diopter (D) addition (add) occurs at the expense of optical quality compared with the previous model with a +4.00 D add. SETTING: Department of Ophthalmology, University of Sao Paulo, Sao Paulo, Brazil. DESIGN: Prospective randomized double-masked comparative clinical trial. METHODS: One year after bilateral implantation of Acrysof Restor SN6AD1 +3.00 D IOLs or Acrysof Restor SN6AD3 +4.00 D IOLs, optical quality was evaluated by analyzing the in vivo modulation transfer function (MTF) and point-spread function (expressed as Strehl ratio). The Strehl ratio and MTF curve with a 4.0 pupil and a 6.0 mm pupil were measured by dynamic retinoscopy aberrometry. The uncorrected and corrected distance visual acuities at 4 m, uncorrected and distance-corrected near visual acuities at 40 cm, and uncorrected and distance-corrected intermediate visual acuities at 50 cm, 60 cm, and 70 cm were measured. RESULTS: Both IOL groups comprised 40 eyes of 20 patients. One year postoperatively, there were no statistically significant between-group differences in the MTF or Strehl ratio with either pupil size. There were no statistically significant between-group differences in distance or near visual acuity. Intermediate visual acuity was significantly better in the +3.00 D IOL group. CONCLUSION: Results indicate that the improvement in intermediate vision in eyes with the aspheric multifocal +3.00 D add IOL occurred without decreasing optical quality over that with the previous version IOL with a +4.00 D add.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background The aim of the present study was to investigate the efficacy and tolerability of acupuncture (AC), Tanacetum (TAN) or combined treatment on quality of life in women with chronic migraine (CM). Methods A total of 69 women volunteers were randomly divided into 3 groups: AC, acupuncture administered in 20 sessions over 10 weeks (n=22); TAN, at 150 mg/day (n=23); and AC+TAN (n=23). The primary outcome was Short-Form 36 (SF-36) quality of life assessment score. Secondary outcomes included the Migraine Disability Assessment (MIDAS) and visual analogue scale (VAS) score experienced after randomisation. Results AC+TAN was statistically significantly more effective than AC or TAN alone in overall health-related quality of life (SF-36; p<0.05), on MIDAS score (-35.1 (10.6) AC vs -24.8 (11.7) TAN vs -42.5 (9.8) AC+TAN; p<0.05) and in reducing the mean score of pain on VAS (-5.6 (2.4) AC vs -3.7 (2.1) TAN vs -6.4 (3.1) AC+TAN; p<0.05). Conclusions The present work shows an improvement of the quality of life and better analgesic effect of acupuncture combined with TAN treatment on migraine pain in women when compared with acupuncture or TAN alone.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Background Radiotherapy is an important tool in the control of pain in patients with spinal metastatic disease. We aimed to evaluate pain and of quality of life of patients with spinal metastatic disease undergoing radiotherapy with supportive treatment. Methods The study enrolled 30 patients. From January 2008 to January 2010, patients selection included those treated with a 20 Gy tumour dose in five fractions. Patients completed the visual analogue scale for pain assessment and the SF-36 questionnaire for quality of life assessment. Results The most frequent primary sites were breast, multiple myeloma, prostate and lymphoma. It was found that 14 spinal metastatic disease patients (46.66%) had restricted involvement of three or fewer vertebrae, while 16 patients (53.33%) had cases involving more than three vertebrae. The data from the visual analogue scale evaluation of pain showed that the average initial score was 5.7 points, the value 30 days after the end of radiotherapy was 4.60 points and the average value 6 months after treatment was 4.25 points. Notably, this final value was 25.43% lower than the value from the initial analysis. With regard to the quality of life evaluation, only the values for the functional capability and social aspects categories of the questionnaire showed significant improvement. Conclusion Radiotherapy with supportive treatment appears to be an important tool for the treatment of pain in patients with spinal metastatic disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJETIVO: Avaliar o impacto das doenças oculares sobre a qualidade de vida de uma população idosa do sertão de Pernambuco, localizado na região nordeste do Brasil. MÉTODOS: Foram entrevistados 580 indivíduos acima de 59 anos, por meio do questionário de avaliação de qualidade de vida "Visual Functioning Questionnaire" (VFQ). Todos os indivíduos foram submetidos a exame oftalmológico completo. Os resultados das variáveis quantitativas foram expressos por suas médias e desvios- padrão. Os resultados das variáveis qualitativas foram expressos por suas frequências absolutas e relativas. RESULTADOS: A média de idade foi de 70 ± 8,1 anos. Cerca de 86,0% dos entrevistados declararam ser analfabetos ou ter o ensino fundamental incompleto. As principais queixas foram: baixa visual (71,1%) e ardor/prurido (69,0%). A acuidade visual não era normal em 37,4% dos idosos. Por volta de 75,0% dos entrevistados relataram ter saúde regular ou ruim, e 77,0% diziam ter uma visão regular ou ruim. A qualidade de vida foi considerada pior conforme a piora da condição visual do idoso. CONCLUSÃO: O déficit visual representou um impacto negativo sobre a qualidade de vida dos idosos do sertão Pernambucano.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Flicker is a power quality phenomenon that applies to cycle instability of light intensity resulting from supply voltage fluctuation, which, in turn can be caused by disturbances introduced during power generation, transmission or distribution. The standard EN 61000-4-15 which has been recently adopted also by the IEEE as IEEE Standard 1453 relies on the analysis of the supply voltage which is processed according to a suitable model of the lamp – human eye – brain chain. As for the lamp, an incandescent 60 W, 230 V, 50 Hz source is assumed. As far as the human eye – brain model is concerned, it is represented by the so-called flicker curve. Such a curve was determined several years ago by statistically analyzing the results of tests where people were subjected to flicker with different combinations of magnitude and frequency. The limitations of this standard approach to flicker evaluation are essentially two. First, the provided index of annoyance Pst can be related to an actual tiredness of the human visual system only if such an incandescent lamp is used. Moreover, the implemented response to flicker is “subjective” given that it relies on the people answers about their feelings. In the last 15 years, many scientific contributions have tackled these issues by investigating the possibility to develop a novel model of the eye-brain response to flicker and overcome the strict dependence of the standard on the kind of the light source. In this light of fact, this thesis is aimed at presenting an important contribution for a new Flickermeter. An improved visual system model using a physiological parameter that is the mean value of the pupil diameter, has been presented, thus allowing to get a more “objective” representation of the response to flicker. The system used to both generate flicker and measure the pupil diameter has been illustrated along with all the results of several experiments performed on the volunteers. The intent has been to demonstrate that the measurement of that geometrical parameter can give reliable information about the feeling of the human visual system to light flicker.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Flowers attract honeybees using colour and scent signals. Bimodality (having both scent and colour) in flowers leads to increased visitation rates, but how the signals influence each other in a foraging situation is still quite controversial. We studied four basic questions: When faced with conflicting scent and colour information, will bees choose by scent and ignore the “wrong” colour, or vice versa? To get to the bottom of this question, we trained bees on scent-colour combination AX (rewarded) versus BY (unrewarded) and tested them on AY (previously rewarded colour and unrewarded scent) versus BX (previously rewarded scent and unrewarded colour). It turned out that the result depends on stimulus quality: if the colours are very similar (unsaturated blue and blue-green), bees choose by scent. If they are very different (saturated blue and yellow), bees choose by colour. We used the same scents, lavender and rosemary, in both cases. Our second question was: Are individual bees hardwired to use colour and ignore scent (or vice versa), or can this behaviour be modified, depending on which cue is more readily available in the current foraging context? To study this question, we picked colour-preferring bees and gave them extra training on scent-only stimuli. Afterwards, we tested if their preference had changed, and if they still remembered the scent stimulus they had originally used as their main cue. We came to the conclusion that a colour preference can be reversed through scent-only training. We also gave scent-preferring bees extra training on colour-only stimuli, and tested for a change in their preference. The number of animals tested was too small for statistical tests (n = 4), but a common tendency suggested that colour-only training leads to a preference for colour. A preference to forage by a certain sensory modality therefore appears to be not fixed but flexible, and adapted to the bee’s surroundings. Our third question was: Do bees learn bimodal stimuli as the sum of their parts (elemental learning), or as a new stimulus which is different from the sum of the components’ parts (configural learning)? We trained bees on bimodal stimuli, then tested them on the colour components only, and the scent components only. We performed this experiment with a similar colour set (unsaturated blue and blue-green, as above), and a very different colour set (saturated blue and yellow), but used lavender and rosemary for scent stimuli in both cases. Our experiment yielded unexpected results: with the different colours, the results were best explained by elemental learning, but with the similar colour set, bees exhibited configural learning. Still, their memory of the bimodal compound was excellent. Finally, we looked at reverse-learning. We reverse-trained bees with bimodal stimuli to find out whether bimodality leads to better reverse-learning compared to monomodal stimuli. We trained bees on AX (rewarded) versus BY (unrewarded), then on AX (unrewarded) versus BY (rewarded), and finally on AX (rewarded) and BY (unrewarded) again. We performed this experiment with both colour sets, always using the same two scents (lavender and rosemary). It turned out that bimodality does not help bees “see the pattern” and anticipate the switch. Generally, bees trained on the different colour set performed better than bees trained on the similar colour set, indicating that stimulus salience influences reverse-learning.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Visuoperceptual deficits in dementia are common and can reduce quality of life. Testing of visuoperceptual function is often confounded by impairments in other cognitive domains and motor dysfunction. We aimed to develop, pilot, and test a novel visuocognitive prototype test battery which addressed these issues, suitable for both clinical and functional imaging use. Methods: We recruited 23 participants (14 with dementia, 6 of whom had extrapyramidal motor features, and 9 age-matched controls). The novel Newcastle visual perception prototype battery (NEVIP-B-Prototype) included angle, color, face, motion and form perception tasks, and an adapted response system. It allows for individualized task difficulties. Participants were tested outside and inside the 3T functional magnetic resonance imaging (fMRI) scanner. Functional magnetic resonance imaging data were analyzed using SPM8. Results: All participants successfully completed the task inside and outside the scanner. Functional magnetic resonance imaging analysis showed activation regions corresponding well to the regional specializations of the visual association cortex. In both groups, there was significant activity in the ventral occipital-temporal region in the face and color tasks, whereas the motion task activated the V5 region. In the control group, the angle task activated the occipitoparietal cortex. Patients and controls showed similar levels of activation, except on the angle task for which occipitoparietal activation was lower in patients than controls. Conclusion: Distinct visuoperceptual functions can be tested in patients with dementia and extrapyramidal motor features when tests use individualized thresholds, adapted tasks, and specialized response systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To describe anticipated health-related quality of life (HRQL) for different hypothetical strategies of febrile neutropenia (FN) management in adult cancer patients. METHODS: Seventy-eight adult cancer patients were enrolled. Our study considered four different hypothetical treatment strategies for FN: (1) entire inpatient management with intravenous (IV) antibiotics; (2) oral treatment at home after an initial observation in hospital with IV antibiotics; (3) entire outpatient management with IV antibiotics; and (4) entire outpatient management with oral antibiotics. Initially, patients were asked to rank the different treatment strategies for FN based on their personal preference. Subsequently, HRQL was rated using visual analog scale (VAS), time trade-off (TTO), and willingness-to-pay (WTP). RESULTS: Seventy-five percent of all respondents preferred an outpatient strategy for FN (36% oral, 21% intravenous, 18% early discharge). Further, outpatient strategies were associated with higher mean VAS scores (possible range 0-10) (oral: 6.1 (standard deviation (SD) 3.1); intravenous: 6.2 (SD 2.2); early discharge: 5.7 (SD 2.1)) as compared to inpatient care (5.3 (SD 2.9)). On the aggregate level, patients were willing to give up between 9 and 10 weeks of their life (TTO; corresponding to <1% of remaining life expectancy) and to pay between $255 and $327 Canadian dollars (WTP) to avoid treatment in hospital. CONCLUSIONS: Our study indicates that the majority of adult cancer patients would prefer an outpatient strategy for FN. However, patients' preferences vary substantially at the individual level. Implementation of outpatient strategies into routine clinical practice should consider this variability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BackgroundDespite the increasingly higher spatial and contrast resolution of CT, nodular lesions are prone to be missed on chest CT. Tinted lenses increase visual acuity and contrast sensitivity by filtering short wavelength light of solar and artificial origin.PurposeTo test the impact of Gunnar eyewear, image quality (standard versus low dose CT) and nodule location on detectability of lung nodules in CT and to compare their individual influence.Material and MethodsA pre-existing database of CT images of patients with lung nodules >5 mm, scanned with standard does image quality (150 ref mAs/120 kVp) and lower dose/quality (40 ref mAs/120 kVp), was used. Five radiologists read 60 chest CTs twice: once with Gunnar glasses and once without glasses with a 1 month break between. At both read-outs the cases were shown at lower dose or standard dose level to quantify the influence of both variables (eyewear vs. image quality) on nodule sensitivity.ResultsThe sensitivity of CT for lung nodules increased significantly using Gunnar eyewear for two readers and insignificantly for two other readers. Over all, the mean sensitivity of all radiologist raised significantly from 50% to 53%, using the glasses (P value = 0.034). In contrast, sensitivity for lung nodules was not significantly affected by lowering the image quality from 150 to 40 ref mAs. The average sensitivity was 52% at low dose level, that was even 0.7% higher than at standard dose level (P value = 0.40). The strongest impact on sensitivity had the factors readers and nodule location (lung segments).ConclusionSensitivity for lung nodules was significantly enhanced by Gunnar eyewear (+3%), while lower image quality (40 ref mAs) had no impact on nodule sensitivity. Not using the glasses had a bigger impact on sensitivity than lowering the image quality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The quality of husbandry of Franches-Montagnes horses (FM) in Switzerland is evaluated on the basis of an investigation carried out in 2002 by the Swiss FM breeding federation. Questionnaires were sent to 3500 of its members and the results include data from 968 breeding enterprises, housing a total of 3965 FM: 46.1% were breeding mares (61.0% with foal at foot), 26.5% young stock, 1.3% stallions and 26.0% non breeding stock (74.6% of which were pleasure horses and 25.4% working horses). 57.6% of the FM were housed in individual boxes with or without permanent outdoor access, 25.4% were hold in groups with or without permanent outdoor access, the remaining 17.0% were kept in standing stalls. 95.0% of the FM had at least visual contact with other equines and 99.2% had sufficient light in their stable. 88.1% were stabled on long stalk straw, while only 4.3% were bedded on other materials other than straw. The average time spent at pasture per horse and per week ranged from 96.5 +/- 51.6 hours in summer to 27.2 +/- 26.7 hours in winter. On average, a FM is used for 8.3 +/- 6.5 hours per week. Horses with an paddock at their disposal spend an average of 39.8 +/- 45.9 hours there per week.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Here we present the development of a visual evaluation system for routine assessment of in vitro-engineered cartilaginous tissue. Neocartilage was produced by culturing human articular chondrocytes in pellet culture systems or in a scaffold-free bioreactor system. All engineered tissues were embedded in paraffin and were sectioned and stained with Safranin O-fast green. The evaluation of each sample was broken into 3 categories (uniformity and intensity of Safranin O stain, distance between cells/amount of matrix produced, and cell morphology), and each category had 4 components with a score ranging from 0 to 3. Three observers evaluated each sample, and the new system was independently tested against an objective computer-based histomorphometry system. Pellets were also assessed biochemically for glycosaminoglycan (GAG) content. Pellet histology scores correlated significantly with GAG contents and were in agreement with the computer-based histomorphometry system. This system allows a valid and rapid assessment of in vitro-generated cartilaginous tissue that has a relevant association with objective parameters indicative of cartilage quality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes the results of a unique "natural experiment" of the operation and cessation of a broadcast transmitter with its short-wave electromagnetic fields (6-22 MHz) on sleep quality and melatonin cycle in a general human population sample. In 1998, 54 volunteers (21 men, 33 women) were followed for 1 week each before and after shut-down of the short-wave radio transmitter at Schwarzenburg (Switzerland). Salivary melatonin was sampled five times a day and total daily excretion and acrophase were estimated using complex cosinor analysis. Sleep quality was recorded daily using a visual analogue scale. Before shut down, self-rated sleep quality was reduced by 3.9 units (95% CI: 1.7-6.0) per mA/m increase in magnetic field exposure. The corresponding decrease in melatonin excretion was 10% (95% CI: -32 to 20%). After shutdown, sleep quality improved by 1.7 units (95% CI: 0.1-3.4) per mA/m decrease in magnetic field exposure. Melatonin excretion increased by 15% (95% CI: -3 to 36%) compared to baseline values suggesting a rebound effect. Stratified analyses showed an exposure effect on melatonin excretion in poor sleepers (26% increase; 95% CI: 8-47%) but not in good sleepers. Change in sleep quality and melatonin excretion was related to the extent of magnetic field reduction after the transmitter's shut down in poor but not good sleepers. However, blinding of exposure was not possible in this observational study and this may have affected the outcome measurements in a direct or indirect (psychological) way.