979 resultados para screen-printed carbon electrode


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Harmful algal blooms (HABs) are becoming more frequent as climate changes, with tropical species moving northward. Monitoring programs detecting the presence of toxic algae before they bloom are of paramount importance to protect aquatic ecosystems, aquaculture, human health and local economies. Rapid and reliable species identification methods using molecular barcodes coupled to biosensor detection tools have received increasing attention over the past decade as an alternative to the impractical standard microscopic counting-based techniques. This work reports on a PCR amplification-free electrochemical genosensor for the enhanced selective and sensitive detection of RNA from multiple Mediterranean toxic algal species. For a sandwich hybridization (SHA), we designed longer capture and signal probes for more specific target discrimination against a single base-pair mismatch from closely related species and for reproducible signals. We optimized experimental conditions, viz., minimal probe concentration in the SHA on a screen-printed gold electrode and selected the best electrochemical mediator. Probes from 13 Mediterranean dinoflagellate species were tested under optimized conditions and the format further tested for quantification of RNA from environmental samples. We not only enhanced the selectivity and sensitivity of the state-of-the-art toxic algal genosensors but also increased the repertoire of toxic algal biosensors in the Mediterranean, towards an integral and automatic monitoring system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Harmful algal blooms (HABs) are becoming more frequent as climate changes, with tropical species moving northward. Monitoring programs detecting the presence of toxic algae before they bloom are of paramount importance to protect aquatic ecosystems, aquaculture, human health and local economies. Rapid and reliable species identification methods using molecular barcodes coupled to biosensor detection tools have received increasing attention over the past decade as an alternative to the impractical standard microscopic counting-based techniques. This work reports on a PCR amplification-free electrochemical genosensor for the enhanced selective and sensitive detection of RNA from multiple Mediterranean toxic algal species. For a sandwich hybridization (SHA), we designed longer capture and signal probes for more specific target discrimination against a single base-pair mismatch from closely related species and for reproducible signals. We optimized experimental conditions, viz., minimal probe concentration in the SHA on a screen-printed gold electrode and selected the best electrochemical mediator. Probes from 13 Mediterranean dinoflagellate species were tested under optimized conditions and the format further tested for quantification of RNA from environmental samples. We not only enhanced the selectivity and sensitivity of the state-of-the-art toxic algal genosensors but also increased the repertoire of toxic algal biosensors in the Mediterranean, towards an integral and automatic monitoring system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A highly sensitive amperometric biosensor for determination of carbamate pesticides directly in water, fruit and vegetable samples has been evaluated, electrochemically characterized and optimized. The biosensor strip was fabricated in screen printed technique on a ceramic support using silver-based paste for reference electrode, and platinum-based paste for working and auxiliary electrodes. The working electrode was modified by a layer of carbon paste mixed with cobalt(II) phthalocyanine and acetylcellulose. Cholinesterase (ChE) enzymes with low enzymatic charge were immobilized on this layer. The operational simplicity of the biosensor consists in that a small drop (similar to 50 mu l) of substrate or sample is deposited on a horizontally positioned biosensor strip representing the microelectrochemical cell. The working potential of the biosensor was 370 mV versus Ag/AgI on a ship reference electrode preventing the interference of electroactive species which are oxidable at more positive potentials. The biosensor was applied to investigate the degradation of two reference ChE inhibitors in freeze dried water under different storage conditions and for direct determination of some N-methylcarbamates (NMCs) in fruit and vegetable samples at ppb concentration levels without any sample pretreatment. A comparison of the obtained results for the total carbamate concentration was done against those obtained using HPLC measurements. (C) 1999 Elsevier B.V. B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Highly ordered mesoporous carbon (MC) has been synthesized from sucrose, a non-toxic and costeffective source of carbon. X-ray diffraction, N2 adsorption–desorption isotherm and transmission electron micrograph (TEM) were used to characterize the MC. The XRD patterns show the formation of highly ordered mesoporous structures of SBA15 and mesoporous carbon. The N2 adsorptiondesorption isotherms suggest that the MC exhibits a narrow pore-size distribution with high surface area of 1559 m2/g. The potential application of MC as a novel electrode material was investigated using cyclic voltammetry for riboflavin (vitamin B2) and dopamine. MC-modified glassy carbon electrode (MC/GC) shows increase in peak current compared to GC electrode in potassium ferricyanide which clearly suggest that MC/GC possesses larger electrode area (1.8 fold) compared with bare GC electrode. The electrocatalytic behavior of MC/GC was investigated towards the oxidation of riboflavin (vitamin B2) and dopamine using cyclic voltammetry which show larger oxidation current compared to unmodified electrode and thus MC/GC may have the potential to be used as a chemically modified electrode.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of fractional-factorial methods in the optimization of porous-carbon electrode structure is discussed with respect to weight-loss of carbon during gas treatment, weight and mixing time of binder, compaction temperature, time and pressure, and pressure of feed gas. The experimental optimization of an air electrode in alkaline solution is described.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, the unique properties of highly ordered mesoporous carbons modified glassy carbon electrode (OMCs/GE) are illustrated from comparison with carbon nanotubes modified glassy carbon electrode (CNTs/GE) for the electrochemical sensing applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Single-walled carbon nanohorn (SWCNH) paste electrode was used for amperometric determination of concentrated hydrogen peroxide, and was compared with other carbon electrodes. The calibration plots are linear from 0.5 to 100 mM at activated SWCNH paste electrode and edge plane graphite (EPG) electrode. In contrast, the calibration plots are linear only at concentrations lower than 45 mM at graphite paste electrode, multi-walled carbon nanotube paste electrode, and glassy carbon electrode.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Graphene nanosheets, dispersed in Nafion (Nafion-G) solution, were used in combination with in situ plated bismuth film electrode for fabricating the enhanced electrochemical sensing platform to determine the lead (Pb2+) and cadmium (Cd2+) by differential pulse anodic stripping voltammetry (DPASV). The electrochemical properties of the composite film modified glassy carbon electrode were investigated. It is found that the prepared Nafion-G composite film not only exhibited improved sensitivity for the metal ion detections, but also alleviated the interferences due to the synergistic effect of graphene nanosheets and Nafion. The linear calibration curves ranged from 0.5 mu g L-1 to 50 mu g L-1 for Pb2+ and 1.5 mu g L-1 to 30 mu g L-1 for Cd2+. respectively. The detection limits (S/N = 3) were estimated to be around 0.02 mu g L-1 for Pb2+ and Cd2+. The practical application of the proposed method was verified in the water sample determination.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel amperometric biosensor utilizing two enzymes, glucose oxidase (GOD) and horseradish peroxidase (HRP), was developed for the cathodic detection of glucose. The glucose biosensor was constructed by electrochemical formation of a polypyrrole (PPy) membrane in the presence of GOD on the surface of a HRP-modified sol-gel derived-mediated ceramic carbon electrode. Ferrocenecarboxylic acid (FCA) was used as mediator to transfer electron between enzyme and electrode. In the hetero-bilayer configuration of electrode, all enzymes were well immobilized in electrode matrices and showed favorable enzymatic activities. The amperometric detection of glucose was carried out at +0.16 V (versus saturated calomel reference electrode (SCE)) in 0.1 M phosphate buffer solution (pH 6.9) with a linear response range between 8.0 x 10(-5) and 1.3 x 10(-3) M glucose. The biosensor showed a good suppression of interference in the amperometric detection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new method for immobilization of a chemiluminescent reagent is presented. It is based on immobilizing hematin, a catalyst for luminol reaction, in the bulk of a carbon paste electrode. Bulk-immobilization allows renewal of the surface by simple polishing or cutting to expose anew and fully active surface in the case of fouling or deactivation by other means. By using a hematin-modified carbon paste electrode, the applied potential shifted negatively compared with that of unmodified carbon paste electrode or a glassy carbon electrode. The shift in potential changed the reaction processes and effectively stabilized the chemiluminescent signal during successive measurements. Under this condition, the signal was stable during 3 hours of continuous operation. The log-log plots of the emitted light intensity vs. luminol concentration and hydrogen peroxide concentration were linear over the region 10(-8)-10(-3) mol L-1 with a correlation coefficient of 0.999 and 3.9 x 10(-6)-10(-3) mol L-1 with a correlation coefficient of 0.994, respectively. Application of this method for other chemiluminescent and bioluminescent systems is suggested.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The electrocatalytic oxidation of hydrazine (N2H4) on a glassy carbon electrode (GC) modified by monolayer and polymer films of cobalt protoporphyrin dimethyl ester (CoPP) has been studied. Both the monolayer and polymer films of CoPP are very active to the anodic oxidation of N2H4. The activity of CoPP for the anodic oxidation of N2H4 is dependent on the pH of the solution, and the thickness of polymerized CoPP film. The oxidation kinetics were examined by methods of cyclic voltammetry, rotating disc electrodes and steady-state polarization measurement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The work presented in this thesis described the development of low-cost sensing and separation devices with electrochemical detections for health applications. This research employs macro, micro and nano technology. The first sensing device developed was a tonerbased micro-device. The initial development of microfluidic devices was based on glass or quartz devices that are often expensive to fabricate; however, the introduction of new types of materials, such as plastics, offered a new way for fast prototyping and the development of disposable devices. One such microfluidic device is based on the lamination of laser-printed polyester films using a computer, printer and laminator. The resulting toner-based microchips demonstrated a potential viability for chemical assays, coupled with several detection methods, particularly Chip-Electrophoresis-Chemiluminescence (CE-CL) detection which has never been reported in the literature. Following on from the toner-based microchip, a three-electrode micro-configuration was developed on acetate substrate. This is the first time that a micro-electrode configuration made from gold; silver and platinum have been fabricated onto acetate by means of patterning and deposition techniques using the central fabrication facilities in Tyndall National Institute. These electrodes have been designed to facilitate the integration of a 3- electrode configuration as part of the fabrication process. Since the electrodes are on acetate the dicing step can automatically be eliminated. The stability of these sensors has been investigated using electrochemical techniques with excellent outcomes. Following on from the generalised testing of the electrodes these sensors were then coupled with capillary electrophoresis. The final sensing devices were on a macro scale and involved the modifications of screenprinted electrodes. Screen-printed electrodes (SPE) are generally seen to be far less sensitive than the more expensive electrodes including the gold, boron-doped diamond and glassy carbon electrodes. To enhance the sensitivity of these electrodes they were treated with metal nano-particles, gold and palladium. Following on from this, another modification was introduced. The carbonaceous material carbon monolith was drop-cast onto the SPE and then the metal nano-particles were electrodeposited onto the monolith material

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Uma nova rede de polímeros interpenetrantes (IPN) baseada em poliuretana de óleo de mamona e poli(etileno glicol) e poli(metacrilato de metila) foi preparada para ser utilizada como eletrólito polimérico. Os seguintes parâmetros de polimerização foram avaliados: massa molecular do poli(etileno glicol) (PEG), concentração de PEG e concentração de metacrilato de metila. As membranas de IPN foram caracterizadas por calorimetria diferencial de varredura (DSC) e espectroscopia de infravermelho por transformada de Fourier (FT-IR). Os eletrólitos de redes de polímeros interpenetrantes (IPNE) foram preparados a partir da dopagem com sal de lítio através do inchamento numa solução de 10% em massa de LiClO4 na mistura de carbonato de etileno e carbonato de propileno na razão mássica de 50:50. As IPNEs foram caracterizadas por espectroscopia de impedância eletroquímica e Raman. As IPNEs foram testadas como eletrólito polimérico em supercapacitores. As células capacitivas foram preparadas utilizando eletrodos de polipirrol (PPy). Os valores de capacitância e eficiência foram calculados por impedância eletroquímica, voltametria cíclica e ciclos galvonostáticos de carga e descarga. Os valores de capacitância obtidos foram em torno de 90 F.g-1 e eficiência variou no intervalo de 88 a 99%. Os valores de densidade de potência foram superiores a 250 W.kg-1 enquanto que a densidade de energia variou de 10 a 33 W.h.kg-1, dependendo da composição da IPNE. As características eletroquímicas do eletrólito formado pela IPN-LiClO4 (IPNE) foram comparadas aos eletrólitos poliméricos convencionais, tais como poli(difluoreto de vinilideno)-(hexafluorpropileno) ((PVDF-HFP/LiClO4) e poliuretana comercial (Bayer desmopan 385) (PU385/LiClO4). As condutividades na temperatura ambiente foram da ordem de 10-3 S.cm-1. A capacitância da célula utilizando eletrodos de PPy com eletrólito de PVDFHFP foi de 115 F.g-1 (30 mF.cm-2) e 110 F.g-1 (25 mF.cm-2) para a célula com PU385 comparadas a 90 F.g-1 (20 mF.cm-2) para a IPNE. Os capacitores preparados com eletrólito de IPNE apresentaram valores de capacitância inferior aos demais, entretanto provaram ser mais estáveis e mais resistentes aos ciclos de carga/descarga. A interpenetração de duas redes poliméricas, PU e PMMA produziu um eletrólito com boa estabilidade mecânica e elétrica. Um protótipo de supercapacitor de estado sólido foi produzindo utilizando eletrodos impressos de carbono ativado (PCE) e o eletrólito polimérico de IPNE. A técnica de impressão de carbono possui várias vantagens em relação aos outros métodos de manufatura de eletrodos de carbono, pois a área do eletrodo, espessura e composição são variáveis que podem ser controladas experimentalmente. As células apresentaram uma larga janela eletroquímica (4V) e valores da capacitância da ordem de 113 mF.cm-2 (16 F.g-1). Métodos alternativos de preparação do PCE investigados incluem o uso de IPNE como polímero de ligação ao carbono ativado, estes eletrodos apresentaram valores de capacitância similares aos produzidos com PVDF. A influência do número de camadas de carbono usadas na produção do PCE também foi alvo de estudo. Em relação ao eletrólito polimérico, o plastificante e o sal de lítio foram adicionados durante a síntese, formando a IPNGel. As células apresentaram alta capacitância e boa estabilidade após 4000 ciclos de carga e descarga. As membranas de IPN foram testadas também como reservatório de medicamento em sistemas de transporte transdérmico por iontoforese. Os filmes, mecanicamente estáveis, formaram géis quando inchado em soluções saturadas de lidocaina.HCl, anestésico local, em propileno glicol (PG), poli(etileno glicol) (PEG400) e suas misturas. O grau de inchamento em PG foi de 15% e 35% em PEG400. Agentes químicos de penetração foram utilizados para diminuir a resistência da barreira causada pela pele, dentre eles o próprio PG, a 2-pirrolidinona (E1) e a 1-dodecil-2-pirrolidinona (E2). Os géis foram caracterizados por espectroscopia de impedância eletroquímica e transporte passivo e por iontoforese através de uma membrana artificial (celofane). O sistema IPN/ lidocaina.HCl apresentou uma correlação linear entre medicamento liberado e a corrente aplicada. Os melhores resultados de transporte de medicamento foram obtidos utilizando o PG como solvente.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work we described for the first time the construction of a 25 μL electrochemical cell from low temperature co-fired ceramic (LTCC) material and carbon screen-printed electrode applicable in portable devices. Firstly, a carbon screen-printed electrode was prepared and characterized by cyclic voltammetry and scanning electron microscopy. Afterwards carbon polymeric film and metal pastes were dropped into the LTCC cell cavities in order to determine the device electrodes, and this arrangement was also electrochemically characterized. The great advantage of this promising device is the simple construction method and its widespread applicability in reusable portable devices. © 2013 The Royal Society of Chemistry.