945 resultados para prosthetic platforms
Resumo:
DNA biosensors have gained increased attention over traditional diagnostic methods due to their fast and responsive operation and cost-effective design. The specificity of DNA biosensors relies on single-stranded oligonucleotide probes immobilized to a transduction platform. Here, we report the development of biosensors to detect the hippuricase gene (hipO) from Campylobacter jejuni using direct covalent coupling of thiol- and biotin-labeled single-stranded DNA (ssDNA) on both surface plasmon resonance (SPR) and diffraction optics technology (DOT, dotLab) transduction platforms. This is the first known report of the dotLab to detect targeted DNA. Application of 6-mercapto-1-hexanol as a spacer thiol for SPR gold surface created a self-assembled monolayer that removed unbound ssDNA and minimized non-specific detection. The detection limit of SPR sensors was shown to be 2.5 nM DNA while dotLab sensors demonstrated a slightly decreased detection limit of 5.0 nM (0.005 μM). It was possible to reuse the SPR sensor due to the negligible changes in sensor sensitivity (∼9.7 × 10 -7 ΔRU) and minimal damage to immobilized probes following use, whereas dotLab sensors could not be reused. Results indicated feasibility of optical biosensors for rapid and sensitive detection of the hipO gene of Campylobacter jejuni using specific ssDNA as a probe. © 2011 Elsevier B.V.
Conservative prosthetic-periodontal treatment for molar class iii furcation involvement: Case report
Resumo:
Purpose: The treatment for furcation involvement is a great challenge to the general dentists. Tunneling may be a treatment alternative for class II and III furcation involvements in mandibular molars with large angle separation and great divergence between the mesial and distal roots. This alternative is a conservative treatment that allows a great condition to oral hygiene maintenance by the patient. Thus, the aim of this case report was to describe a conservative and therapeutic treatment modality for the horizontal defect of periodontal tissues in the furcal area with buccal-lingual extension (class III furcation involvement). Case Report: A patient with class III furcation involvement in the first mandibular molar was submitted to root resection and periodontal surgery to expose the clinical crown for the full-coverage restoration with tunnel preparation. Results: The final result of the treatment with tunneled crown was favorable and predictable due to adequate hygiene condition to avoid plaque accumulation and occurrence of root caries. Clinical Significance: A multidisciplinary approach is essential to achieve a correct treatment plan including surgical-periodontal procedures integrated to the prosthetic rehabilitation. Besides, the recommendation for oral hygiene maintenance is essential for the treatment longevity with tunneled crown. © 2011 Nova Science Publishers, Inc.
Resumo:
The placement of implants in fresh extraction sockets followed for provisionalization allows soft tissues preservation and alveolar ridge, however for this some requisites are necessary. This article describe the factors involved in immediate implants and the prosthetic approachs for this type of therapy. Addtionaly two clinicals case were presented showing diferents approachs for in prosthetic stage for maintenance the aesthetic aperance of soft tissues of the immediate implants.
Resumo:
Control of cross-contamination between dental offices and prosthetic laboratories is of utmost importance to maintain the health of patients and dental office staff. The purpose of this study was to evaluate disinfection protocols, considering antimicrobial effectiveness and damage to the structures of prostheses. Solutions of 1% sodium hypochlorite, 2% chlorhexidine digluconate, 50% vinegar and sodium perborate were evaluated. Specimens were contaminated in vitro with standardized suspensions of Candida albicans, Streptococcus mutans, Escherichia coli, Staphylococcus aureus and Bacillus subtilis spores. Disinfection by immersion for 10. min was performed. Final counts of microorganisms were obtained using the plating method. Results were statistically compared by Kruskal-Wallis ANOVA and Dunn's test. The surface roughness of 40 specimens was analyzed before and after 10 disinfection cycles, and results were compared statistically using Student's t test. The solution of 50% vinegar was as effective as 1% sodium hypochlorite and 2% chlorhexidine against C. albicans, E. coli and S. mutans. The sodium perborate solution showed the lowest antimicrobial effectiveness. Superficial roughness increased after cycles in 1% sodium hypochlorite (p=0.02). Solutions of 1% sodium hypochlorite, 2% chlorhexidine and 50% vinegar were effective for the disinfection of heat-polymerized acrylic specimens. Sodium hypochlorite increased the superficial roughness. © 2013 King Saud Bin Abdulaziz University for Health Sciences.
Resumo:
This edition of the FAL Bulletin approaches the issue of logistic platforms and the public sector’s role in the development of the logistic sector.
Resumo:
In the past few years there has been a clear trend of attaching increasing importance to "inforstructures", or the capacity of ports to process the information that accompanies foreign trade flows, so that the processing becomes a facilitating factor for trade, rather than an obstacle.This led to development of the concept of a port community system, which is a computerized system that interconnects all the members of a logistics community, making the exchange of documentation as effective as possible, reducing the volume of data to be re-entered in different systems and ultimately improving the whole process of monitoring an operation until its completion. Computerization of communications between all the actors at the ports facilitates integration of the community, while it also assists interaction between ports, thus forming logistics corridors.
Resumo:
This issue of the FAL Bulletin examines the economic, institutional, social and environmental aspects of logistics platforms, which help to support competitive economies in a sustainable and egalitarian environment.
Resumo:
The purpose of this systematic review was to evaluate clinical studies on the follow-up survival of implants inserted in the zygomatic bone for maxillary rehabilitation. A comprehensive search of studies published from 2000 to July 2012 and listed in the PubMed/MEDLINE, Embase, and Cochrane Library databases was performed in accordance with the PRISMA statement. Relevant studies were selected according to predetermined inclusion and exclusion criteria. The initial database search yielded 751 titles. After filtering, 313 abstracts were selected, culminating in 42 full text articles. Application of eligibility criteria led to the elimination of 17 articles. Hence 25 full-text articles were considered clinically relevant and were included. Calculations of the interval survival rates and cumulative survival rates of implants could be carried out on the data extracted from the final list of included studies for the different time intervals. These studies reported the insertion of a total of 1541 zygomatic implants and 33 implant failures. Failure generally occurred during the first year interval and was related to clinical complications, such as recurrent acute and chronic sinusitis. After a 36-month follow-up, the survival rate was 97.86%. Additional studies with longer follow-up periods, including the number of zygomatic implants inserted and details of the variations in the surgical techniques used and the impact of the maxillary morphology are still required.
Resumo:
When dental implants are malpositioned in relation to the adjacent teeth and alveolar bone or in an excessive buccal or lingual position, the final prosthesis rehabilitation impairs the peri-implant health of the gingival tissues and the aesthetics of the patient. Thus, the purpose of this case was to report and discuss a multidisciplinary protocol for the treatment of a compromised maxillary tooth in a patient with an abscess in his right central incisor due to an excessive buccal implant position. The patient presented with an implant-supported provisional restoration on his right maxillary central incisor and a traumatic injury in his left central incisor. The treatment protocol consisted in (i) abutment substitution to compensate the incorrect angulation of the implant, (ii) clinical crown lengthening, (iii) atraumatic extraction of the left central incisor, and (iv) immediate implant placement. Finally, (v) a custom abutment was fabricated to obtain a harmonious gingival contour around the prosthetic crown. In conclusion, when implants are incorrectly positioned in relation to the adjacent teeth, associated with soft-tissue defects, the challenge to create a harmonious mucogingival contours may be achieved with an interdisciplinary approach and with the placement of an appropriate custom abutment.
Resumo:
This study investigated the biomechanical behavior of screwed partial fixed prosthesis supported by implants with different diameters (2.5 mm; 3.3 mm and 3.75 mm) by using a photoelastic analysis. Six photoelastic models were fabricated in PL-2 resin as single crowns or splinted 3-unit piece. Models were positioned in a circular polariscope and 100-N axial and oblique (45 degrees) loads were applied in the occlusal surface of the crowns by using a universal testing machine (EMIC). The stresses were photographically recorded and qualitatively analyzed using a software (Adobe Photoshop). Under axial loading, the number of fringes was inversely proportional to the diameter of the implants in the single crown models. In the splinted 3-unit piece, the 3.75-mm implant promoted lower number of fringes regardless of loading area application. Under oblique loading, a slight increase of fringes number was observed for all groups. The standard implant diameter promoted better stress distribution than the narrow and mini diameter implants. Additionally, the splinted crowns showed a more uniform stress distribution.
Resumo:
The gastroesophageal reflux disease (GERD) is one of the main causes of dental erosion. The aim of this case presented is to describe the prosthetic rehabilitation of a patient with GERD after 4 years of followup. A 33-year-old male patient complained about tooth sensitivity. The lingual surface of the maxillary anterior teeth and the cusps of the upper and lower posterior teeth presented wear. It was suspected that the feeling of heartburn reported by the patient associated with the intake of sports supplements (isotonics) was causing gastroesophageal changes. The patient was referred to a gastroenterologist and was diagnosed with GERD. Dental treatment was performed with metal-free crowns and porcelain veneers after medical treatment of the disease. With the change in eating habits, the treatment of GERD and lithium disilicate ceramics provided excellent cosmetic results after 4 years and the patient reported satisfaction with the treatment.
Resumo:
The treatment of orofacial tumors may cause facial deformities by losses of structures that affect basic functions, i.e. feeding, speech, and the reduction of patient self-steam. A white male patient was diagnosed with epidermoid cancer on the mandibular alveolar ridge with infiltration staging IV A. The patient was submitted to a mandibulectomy associated with a complete extraction of mandibular teeth. For rehabilitation, a conventional denture for the mandibular arch and a removable partial denture for the maxillary arch were fabricated. A correct occlusal adjustment and a satisfactory amount of alveolar bone was favorable for conventional dentures of the prostheses bases improve their retention and stability. After one year of follow-up, the patient was adapted to the prostheses, satisfied with their retention, and reported an improvement on his feeding. The prosthetic rehabilitation of patients after a partial mandibulectomy is essential for their self-steam. Conventional dentures may have their retention and stability improved if they are well fabricated, recorded and have a balanced occlusion. A correct occlusal adjustment and an adequate retention of the prostheses bases may improve their retention and stability. Patients without xerostomy and with a satisfactory amount of alveolar bone may have a favorable prognosis for conventional dentures.
Resumo:
Vortex-induced motions (VIM) of floating structures are very relevant for the design of mooring and riser systems. In the design phase, spar and monocolumn VIM behavior, as well as semisubmersible and tension leg platform flow-induced motions, is studied and evaluated. This paper provides a checklist of topics and evidence from a number of sources to justify the selection that should be considered when designing spars or monocolumn platforms regarding the VIM phenomenon. An overview of the influential aspects of the VIM is presented such as heading, external appendages of the hull, concomitant presence of waves and currents, motion suppressor, draft condition (immersed portion of the hull), and external damping due to the presence of risers. Previous works concerning the VIM studies on spar and monocolumn platforms are also addressed. Whenever possible, the results of experiments from diverse authors on this matter are presented and compared. [DOI: 10.1115/1.4003698]
Resumo:
Objectives: The aim of this study was to evaluate the variation in removal torque of implant prosthetic abutment screws after successive tightening and loosening cycles, in addition to evaluating the influence of the hexagon at the abutment base on screw removal torque. Material and methods: Twenty hexagonal abutments were tightened to 20 regular external hex implants with a titanium alloy screw, with an insertion torque of 32 N cm, measured with a digital torque gauge. The implant/abutment/screw assemblies were divided into two groups: ( 1) abutments without hexagon at the base and ( 2) abutments with a hexagon at the base. Each assembly received a provisional restoration and was submitted to mechanical loading cycles. After this, the screws were removed and the removal torque was measured. This sequence was repeated 10 times, then the screw was replaced by a new one, and another cycle was performed. Linear regression analysis was performed. Results: Removal torque values tended to decrease as the number of insertion/removal cycles increased, for both groups. Comparisons of the slopes and the intercepts between groups showed no statistical difference. There was no significant difference between the mean values of last five cycles and the 11th cycle. Within the limitations of this in vitro study, it was concluded that ( 1) repeated insertion/removal cycles promoted gradual reduction in removal torque of screws, ( 2) replacing the screw with a new one after 10 cycles did not increase resistance to loosening, and ( 3) removal of the hexagon from the abutment base had no effect on the removal torque of the screws.