909 resultados para intrauterine device


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The University of Barcelona is developing a pilot-scale hot wire chemical vapor deposition (HW-CVD) set up for the deposition of nano-crystalline silicon (nc-Si:H) on 10 cm × 10 cm glass substrate at high deposition rate. The system manages 12 thin wires of 0.15-0.2 mm diameter in a very dense configuration. This permits depositing very uniform films, with inhomogeneities lower than 2.5%, at high deposition rate (1.5-3 nm/s), and maintaining the substrate temperature relatively low (250 °C). The wire configuration design, based on radicals' diffusion simulation, is exposed and the predicted homogeneity is validated with optical transmission scanning measurements of the deposited samples. Different deposition series were carried out by varying the substrate temperature, the silane to hydrogen dilution and the deposition pressure. By means of Fourier transform infrared spectroscopy (FTIR), the evolution in time of the nc-Si:H vibrational modes was monitored. Particular importance has been given to the study of the material stability against post-deposition oxidation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We described for the first time the amino acid substitutions conferring rifampicin resistance in eight Propionibacterium acnes strains isolated from patients with biofilm or device-related infections. We identified different mutations in cluster I and one mutation, never reported, in cluster II of the rpoB gene (I480V) associated with the most frequent one in cluster I (S442L). Half of the patients previously received treatment with rifampicin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Transapical transcatheter valve procedures are performed through a left minithoracotomy and require apical sutures to seal the apical access site. The use of large-calibre devices compromises any attempt to fully perform the procedure with a thoracoscopic approach or percutaneously. We report our preliminary experience in animals with a new sutureless self-expandable apical occluder, engineered to perform transapical access site closure in a minimally invasive setting with large-size introducer sheaths. METHODS: The apical occluder with extendable waist was implanted in six young pigs during an acute animal study. Under general anaesthesia, animals (mean weight: 62 ± 8 kg) received full heparinization (heparin: 100 UI/kg; activated clotting time above 250 s). Through a median sternotomy, a 21-Fr Certitude? introducer sheath (outer diameter: 25 Fr) was placed over the wire into the cardiac apex. The delivery catheter carrying the constrained apical plug was inserted into the sheath and deployed under fluoroscopic control, whereas the Certitude? was retrieved. After protamine infusion, we observed and recorded the 1-h bleeding with standard haemodynamic parameters. Animals were sacrificed, and hearts analysed. RESULTS: Six apical closure devices were successfully introduced and deployed in six pig hearts through large-size apical sheaths at first attempt. In all animals, the plugs guaranteed immediate apical sealing and traces of blood were collected in the pericardium during the 1-h observational period (mean of 16 ± 3.4 ml of blood loss per animal). Haemodynamic parameters remained stable during the entire study period and no plug dislodgement was detected with normal systemic blood pressure (mean arterial mean blood pressure: 65 ± 7 mmHg). Post-mortem analysis confirmed the full deployment and good fixation of all plugs, without macroscopic damages to the surrounding myocardium. CONCLUSIONS: This sutureless self-expandable apical occluder is a simple device capable of sealing large-size apical access sites (20-35 Fr) in an acute animal study. This approach is a step further towards less invasive transapical valve procedures in the clinical setting, and further animal tests will be performed to confirm the long-term efficacy and safety of this device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Testing of a complex software is time consuming. Automated tools are available quite a lot for desktop applications, but for embedded systems a custom-made tool is required Building a complete test framework is a complicated task. Therefore, the test platform was built on top of an already existing tool, CANoe. CANoe is a tool for CAN bus analysis and node simulation. The functionality of CANoe was extended with LabVIEW DLL. The LabVIEW software was used for simulating hardware components of the embedded device As a result of the study, a platform was created where tests could be automated. Of the current test plan, 10 percent were automated and up to 60 percent could be automated with the current functionality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Raspberry Pi is a low-cost computer created with educational purposes. It uses Linux and, most of times, freeware applications, particularly a software for viewing DICOM images. With an external monitor, the supported resolution (1920 × 1200 pixels) allows for the set up of simple viewing workstations at a reduced cost.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intrauterine growth restriction (IUGR) is one of the leading causes of perinatal mortality and morbidity. Nowadays, this condition is detected in the 3rt and last trimester of gestation when the pathology is already established and success of therapeutic strategies are limited. As the physiopathology of the disease suggests that the problem stems from poor placental implantation, it would be quite advantageous to identify women at increased risk in the first or second trimester of gestation because it then might be possible to offer treatment interventions or at least to establish increased surveillance for high risk pregnancies. Maternal levels of pregnancy-associated plasma protein-A (PAPP-A) and free β human chorionic gonadotropin (free βhCG) has been shown to be effective in first trimester screening for chromosomal abnormalities, primarily trisomies 21, 13 and 18. Previous studies evaluating PAPP-A and free βhCG measured in the first trimester in relation with IUGR have provided conflicting results. Moreover, it has been suggested that black ethnicity is another important predictive factor for fetal growth restriction.Objective: To analyse the association between first trimester serum analytes (PAPP-A and free βhCG) and ethnicity with Intrauterine Growth Restriction.Methods: The study consists in a retrospective cohort, including all singleton pregnancies with complete outcome data that had undergone first trimester screening (PAPP-A and free βhCG) at 11-13+6weeks of gestation between 1/1/2010 - 31/12/2012 in Hospital Universitari Dr Josep Trueta. Biochemical markers are converted to multiples of the median (MoMs) and percentiles 5 and 10 are calculated. The association between free βhCG and PAPP-A with the incidence of IUGR is evaluated in combination with maternal ethnicity. Bivariate and logistic regression analyses are performed to adjust this association for co variables

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present here the first part of the literature review regarding our study object, the Open Device Labs. The research on ODLs emerges from the observation of worldwide non-profit movement, which, through mutual collaboration, information and devices sharing, proposes a final improvement on user’s experience with the web and app.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A photometric procedure was developed for determination of aflatoxin B1 in peanuts by TLC-CCD technique. The quantification and detection limit were 1.2 μg kg-1 and 0.4 ng per spot, respectively, with mean recovery of 98%. The CCD camera is sufficiently sensitive to detect small changes in spots fluorescence intensity and the results for performance confirmed the efficiency of the method. Another important property of CCD detector is its linearity for a wide range of luminous stimulus determined by analysis of five-point calibration curves using the intensity of AFB1 fluorescence versus AFB1 concentration (0.8 to 4.8 ng per spot). The method was applied to the analysis of thirty nine peanut samples and aflatoxin B1 levels ranged from 16 to 115 μg kg-1. The TLC-CCD and the photometric procedure developed in this study demonstrated to be a simple and efficient tool for quantitative analyses of AFB1 in peanut samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report describes a simple, inexpensive and highly effective instructional model based on the use of a tablet device to enable the real-time projection of the instructor's digitally handwritten annotations to teach chemistry in undergraduate courses. The projection of digital handwriting allows the instructor to build, present and adapt the class contents in a dynamic fashion and to save anything that is annotated or displayed on the screen for subsequent sharing with students after each session. This method avoids the loss of continuity and information that often occurs when instructors switch between electronic slides and white/chalk board during lessons. Students acknowledged that this methodology allows them to follow the instructor's cognitive process and the progressive development of contents during lectures as the most valuable aspect of the implemented instructional model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Pacemaker implantation (PMI) may predispose to venous thromboembolism (VTE) and obstruction (VO). This prospective study aimed at quantifying changes in venous calibers, and at determining the incidence of symptomatic and asymptomatic VTE/VO after PMI. Further goals included an assessment of the role of transesophageal echocardiography (TEE) in the diagnosis of lead-related central venous thrombi (CVT), and determination of predictors for VTE/VO. Methods: 150 (mean age 67; 61% male) consecutive patients with first PMI were enrolled and followed for 6 months. Contrast venography was performed at baseline and 6 months after PMI to measure venous diameters, and to detect stenosis, total occlusions and thrombi. TEE was conducted in 66 patients. Based on clinical suspicion, work-up for pulmonary embolism (PE) or acute deep vein thrombosis (DVT) were performed as needed. A total of 50 cases underwent longer-term (mean 2.4 years) follow-up venography. All cases with VTE/VO during the initial 6 months, and their matched controls, were selected for a case-control study focused on possible predictive role of laboratory and patient-related factors for the development of VTE/VO. Results: 10 (7 %) patients were found to have baseline venous abnormalities (e.g. 8 obstructions). Mean venous diameters diminished significantly during the first 6 months, but no further reduction occurred in late follow-up. New VO was discovered in 19 patients (14 %; 14 stenosis, 5 total occlusions; all asymptomatic). Small non-obstructive thrombi were found in 20/140 (14 %) 6-month venograms. TEE at 6 months disclosed CVT in 6 (9 %) patients. One (0.7 %) patient had acute symptomatic upper-extremity DVT, and PE was discovered in 5/150 (3.3 %) patients during the first 6 months with no further cases thereafter. At 6 months, the total number of cases with VTE/VO amounted to 47 (31.3 %). Additionally, the later 2-year venograms (n=50) disclosed 4 (8 %) total occlusions and 1 (2 %) stenosis. In the case-control study, no parameter was predictive of venous end-points as a single variable, but there appeared to be significant clustering of traditional VTE risk-factors among the cases. Laboratory parameters showed a definite acute hypercoagulative state induced by PMI, but its degree did not predict subsequent development of VTE/VO. Conclusions: This study shows that VTE/VO is relatively common after PMI with an overall incidence of at least 30 %. Although the majority of the lesions are asymptomatic and clinically benign, cases of PE were also encountered, and totally occluded veins may hamper future upgrading or replacement of pacing system. Venous complications seem difficult to prognosticate as firm predictors were not identified from a wide range of parameters analyzed in this study, although clustering of classic VTE risk factors may be a predisposing factor. Parameters related to implantation procedure or pacing systems and the severity of implantation-induced trauma did not emerge as predictors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The subject being analyzed of this Master’s Thesis is a development of a service that is used to define a current location of a mobile device. The service utilized data that is obtained from own GPS receiver in some possible cases and as well data from mobile devices which can be afforded for the current environment for acquisition of more precise position of the device. The computation environment is based on context of a mobile device. The service is implemented as an application for communicator series Nokia N8XX. The Master’s Thesis presents theoretical concept of the method and its practical implementation, architecture of the application, requirements and describes a process of its functionality. Also users’ work with application is presented and recommendations for possible future improvements are made.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently most of the mobile phone manufacturer companies started to pay extra attention to their websites. This research investigates the sources of value creation on the mobile phone manufacturers’ website and the affect visiting the manufacturers’ website has on brand loyalty and brand satisfaction. The results show a correlation between positive website usage experience, brand loyalty and brand satisfaction. Moreover there is a relation between Novelty, Efficiency, Lock-in and the perceived usefulness the manufacturers’ website has on the mobile phone device. And finally the main reason behind Finnish student’s mobile phone brand loyalty is its country of origin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diplomityön tavoitteena oli kehittää Wipak Oy:n valmistamille sterilointipakkauksille tulevaisuuden pakkauskonsepti. Sterilointipakkaukset luokitellaan lääkelaitedirektiivin mukaan lisätarvikkeiksi luokan 1 lääkelaitteille, ja tämä näkökulma oli vahvasti mukana konseptin kehityksessä. Lähtökohtana pakkauskonseptin suunnittelulle oli tuotteiden arvoketjussa, eli pakata tuotteet siten että pakkausten avulla voidaan tuottaa lisäarvoa arvoketjun toimijoille. Tavoitteena oli parantaa pakkausten viestintää, toimivuutta/tehokkuutta toimitusketjussa sekä vahvistaa brändin imagoa myynti- ja kuljetuspakkauksen avulla. Lääkinnälliset laitteet ja tarvikkeet ovat lainsäädännön ja normien avulla tarkasti säädeltyjä. Näiden normien vaatimukset asettavat perusteet myynti- ja kuljetuspakkausten kehittämiselle. Tämän lisäksi suunnittelussa on huomioitu asiakkaiden toiveet ja kehitystarpeet. Kirjallisuusosuudessa on keskitytty lääkinnällisten laitteiden pakkausyksiköiden toimintoihin sekä niiden kehitysnäkymiin. Pääpaino on ollut pakkausmerkintöjen ja jäljitettävyyden kehittämisellä, koska tietojen automaattisen tunnistuksen hyödyntäminen lääkintälaitteiden pakkausten arvoketjussa on kasvava trendi. Manuaalisesti tehtävät tuotevirtojen kirjaukset ketjun eri toimijoiden osalta lisäävät riskejä jäljitettävyyden kannalta ja aiheuttavat lisätyötä ja – kustannuksia ketjun kaikille osapuolille. Ehdotus uudesta pakkauskonseptista on kehitetty näiden tietojen pohjalta. Ehdotuksessa on huomioitu lainsäädännöstä ja ketjun toimijoilta tulevat tarpeet, sekä alan tulevaisuuden kehitysnäkymät. Ehdotetun pakkauskonseptin avulla saadaan lisättyä myynti- ja kuljetuspakkausten tehokkuutta, parannettua jäljitettävyyttä ja helpotettu arvoketjun alavirran toimijoiden työtä lisäämällä erillinen sisäpakkaus myyntiyksikön sisälle. Työssä on lisäksi selvitetty pakkauskonseptin kustannusvaikutukset tuotteiden hintaan. Lopussa on ehdotettu jatkotoimenpiteet suunnitelman implementoimisesta käytäntöön.