996 resultados para indoor radon monitoring


Relevância:

20.00% 20.00%

Publicador:

Resumo:

ZigBee-based Remote Patient Monitoring

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: This work presents detailed experimental performance results from tests executed in the hospital environment for Health Monitoring for All (HM4All), a remote vital signs monitoring system based on a ZigBee® (ZigBee Alliance, San Ramon, CA) body sensor network (BSN). MATERIALS AND METHODS: Tests involved the use of six electrocardiogram (ECG) sensors operating in two different modes: the ECG mode involved the transmission of ECG waveform data and heart rate (HR) values to the ZigBee coordinator, whereas the HR mode included only the transmission of HR values. In the absence of hidden nodes, a non-beacon-enabled star network composed of sensing devices working on ECG mode kept the delivery ratio (DR) at 100%. RESULTS: When the network topology was changed to a 2-hop tree, the performance degraded slightly, resulting in an average DR of 98.56%. Although these performance outcomes may seem satisfactory, further investigation demonstrated that individual sensing devices went through transitory periods with low DR. Other tests have shown that ZigBee BSNs are highly susceptible to collisions owing to hidden nodes. Nevertheless, these tests have also shown that these networks can achieve high reliability if the amount of traffic is kept low. Contrary to what is typically shown in scientific articles and in manufacturers' documentation, the test outcomes presented in this article include temporal graphs of the DR achieved by each wireless sensor device. CONCLUSIONS: The test procedure and the approach used to represent its outcomes, which allow the identification of undesirable transitory periods of low reliability due to contention between devices, constitute the main contribution of this work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Há muito que se fala do fim do Marketing tal como o conhecemos. A segmentação cada vez maior de mercados e clientes e a importância da customização, tornaram obsoletas a maior parte das abordagens do marketing de massas. A evolução da economia e das TI (tecnologias da informação) e as consequentes alterações que esse processo implicou na cadeia de valor das empresas, nomeadamente das organizações de grande dimensão, fez com que o B2C –Business to Customer – tenha deixado de fazer sentido para estas empresas. O advento da World Wide Web e o impacto que as tecnologias «interactivas» têm actualmente sobre a economia, provocou grandes alterações nas relações entre as organizações e os seus clientes. Ao Marketing de massas sucedeu-se a relação individualizada cliente a cliente, emergente no B2B – Business to Business –one to one, onde mais importante do que as vendas é o relacionamento com o cliente que assume particular importância, nomeada mente em ordem à sua transição para outras zonas de negócio, como a Internet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study’s main purpose was the assessment of the environmental fungal contamination, the exploration of possible associations between related environmental variables and the study of the relationship between fungal contamination of air and surfaces. A descriptive study was developed based upon air and surfaces monitoring for fungal contamination in ten indoor gymnasiums with a swimming pool located in Lisbon’s urban area. Fifty 200 litres air samples and 120 surface swabs were collected. Surfaces samples were collected before and after cleaning and disinfection and temperature and relative humidity values were registered during the collection period. Twenty five different species of fungi were identified in the air samples, being the three most commonly isolated genera the following: Cladosporium (36.6%), Penicillium (19.0%) and Aspergillus (10.2%). Thirty-seven different species of fungi were identified in the surface samples. Fusarium sp. was the most frequent genera before (19.1%) and after (17.2%) cleaning and disinfection. There was a significant association between the numbers of visitors and the fungal contamination determined in the surface samples (p<0.05). There was no significant association (p>0.05) between the contamination encountered in the air samples and the one registered in the surface samples and between the fungal contamination and the temperature or relative humidity measured on location. The data obtained enabled the assessment of the establishment’s fungal contamination and led the authors to conclude, consequently, that physical activity, which generally promotes health, can in fact be challenged by this factor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fungal contamination of air in 10 gymnasiums with swimming pools was monitored. Fifty air samples of 200 L each were collected, using a Millipore air tester, from the area surrounding the pool, in training studios, in showers and changing rooms for both sexes, and also, outside premises, since these are the places regarded as reference. Simultaneously, environmental parameters – temperature and humidity – were also monitored. Some 25 different species of fungi were identified. The six most commonly isolated genera were the following: Cladosporium sp. (36.6%), Penicillium sp. (19.0%), Aspergillus sp. (10.2%), Mucor sp. (7%), Phoma sp. and Chrysonilia sp. (3.3%). For yeasts, three different genera were identified, namely, Rhodotorula sp. (70%), Trichosporon mucoides and Cryptococcus uniguttulattus (10%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Formaldehyde was the first air pollutant, which already in the 1970s emerged as a specifically non-industrial indoor air quality problem. Yet formaldehyde remained an indoor air quality issue and the formaldehyde level in residential indoor air is among the highest of any indoor air contaminant. Formaldehyde concentrations in 4 different indoor settings (schools, office buildings, new dwellings and occupied dwellings) in Portugal were measured using Photo Ionization Detection (PID) equipment (11,7 eV lamps). All the settings presented results higher than the reference value proposed by Portuguese legislation. Furthermore, occupied dwellings showed 3 units with results above the reference. We could conclude that formaldehyde presence is a reality in monitored indoor settings. Concentration levels are higher than the Portuguese reference value for indoor settings and these can indicate health problems for occupants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exposure assessment is an important step of risk assessment process and has evolved more quickly than perhaps any aspect of the four-step risk paradigm (hazard identification, exposure assessment, dose-response analysis, and risk characterization). Nevertheless, some epidemiological studies have associated adverse health effects to a chemical exposure with an inadequate or absent exposure quantification. In addition to the metric used, the truly representation of exposure by measurements depends on: the strategy of sampling, random collection of measurements, and similarity between the measured and unmeasured exposure groups. Two environmental monitoring methodologies for formaldehyde occupational exposure were used to assess the influence of metric selection in exposure assessment and, consequently, in risk assessment process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A biomonitoring study, using transplanted lichens Flavoparmelia caperata, was conducted to assess the indoor air quality in primary schools in urban (Lisbon) and rural (Ponte de Sor) Portuguese sites. The lichens exposure period occurred between April and June 2010 and two types of environments of the primary schools were studied: classrooms and outdoor/courtyard. Afterwards, the lichen samples were processed and analyzed by instrumental neutron activation analysis (INAA) to assess a total of 20 chemical elements. Accumulated elements in the exposed lichens were assessed and enrichment factors (EF) were determined. Indoor and outdoor biomonitoring results were compared to evaluate how biomonitors (as lichens) react at indoor environments and to assess the type of pollutants that are prevalent in those environments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Total particulate matter (TPM) was passively collected inside two classrooms of each of five elementary schools in Lisbon, Portugal. TPM was collected in polycarbonate filters with a 47 mm diameter, placed inside of uncovered plastic petri dishes. The sampling period was from 19 May to 22 June 2009 (35 days exposure) and the collected TPM masses varied between 0.2 mg and 0.8 mg. The major elements were Ca, Fe, Na, K, and Zn at μg level, while others were at ng level. Pearson′s correlation coefficients above 0.75 (a high degree of correlation) were found between several elements. Soil-related, traffic soil re-suspension and anthropogenic emission sources could be identified. Blackboard chalk was also identified through Ca large presence. Some of the determined chemical elements are potential carcinogenic. Quality control of the results showed good agreement as confirmed by the application of u-score test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clean air is a basic requirement of life. The Indoor Air Quality (IAQ) has been the object of several studies due to an increasing concern within the scientific community on the effects of indoor air quality upon health, especially as people tend to spend more time indoors than outdoors. The quality of air inside homes, offices, schools or other private and public buildings is an essential determinant of healthy life and people’s well-being. People can be exposed to contaminants by inhalation, ingestion and dermal contact. In the past, scientists have paid much attention to the study of exposure to outdoor air contaminants, because they have realised the seriousness of outdoor air pollution problems. However, each indoor microenvironment has unique characteristics, determined by the local outdoor air, specific building characteristics and indoor activities. Indeed, hazardous substances are emitted from buildings, construction materials and indoor equipment or due to human activities indoors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As redes de telecomunicações nos últimos anos têm sofrido um grande desenvolvimento a nível tecnológico. A prova disso é a revolução das redes sem fios, iniciada com a tecnologia GSM (Global System Mobile) nos anos 90, na qual eram apenas disponibilizados serviços de voz. Esta tendência continuou com o GPRS (General Packet Radio Service) onde se iniciaram os serviços de dados surgindo assim mais tarde, a tecnologia UMTS (Universal Mobile Telecommunications System). Com o aparecimento da nova tecnologia LTE (Long-Term Evolution), surgiu um novo paradigma consumista no mercado, facto que gerou um conflicto directo com as redes de banda larga (ADSL - Asymmetric Digital Subscriber Line) fornecidas anteriormente apenas pela rede fixa. A partir deste momento, estas duas tecnologias passaram a oferecer altos débitos de dados, eliminando assim esta diferenciação existente até então entre ambas. Esta foi a plataforma que despoletou o meu interesse em explorar a tecnologia LTE, mais precisamente, o planeamento de rádio em ambientes Indoor e Outdoor. Este planeamento requeria uma comparação prática e teórica, de forma a observar que a tecnologia reflectia os valores estipulados na norma LTE. Como método de comparação foi utilizada uma ferramenta de planeamento de redes móveis, gentilmente disponibilizada pela Alcatel-Lucent para o tipo de ambiente outdoor em estudo, para o indoor não foi efectuado simulação, por indisponibilidade da ferramenta. Após a configuração do sistema de rádio foi efectuada a recolha de dados no terreno através de drive-testes. Findo esta fase, procedeu-se ao pós-processamento e análise dos dados recolhidos, por forma a ser possível estabelecer a comparação entre o planeamento teórico efectuado através da ferramenta de planeamento e os dados capturados no terreno. Os resultados obtidos demonstram que a cobertura preconizada no caso Outdoor estavam de acordo com o planeamento efectuado, uma vez que os dados medidos no terreno coincidiram com os valores simulados, apenas com um desvio mínimo dentro da margem de tolerância. No que respeita ao indoor verificou-se que as medidas estavam de acordo com o estipulado na norma. Como conclusão, confirmou-se a validade das ferramentas e da metodologia utilizada.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A descriptive study was developed in order to compare indoor and outdoor air contamination caused by fungi and particles in seven poultry units. Twenty eight air samples of 25 litters were collected through the impaction method on malt extract agar. Air sampling and particles concentration measurement were done in the interior and also outside premises of the poultries’ pavilions. Regarding the fungal load in the air, indoor concentration of mold was higher than outside air in six poultry units. Twenty eight species / genera of fungi were identified indoor, being Scopulariopsis brevicaulis (40.5%) the most commonly isolated species and Rhizopus sp. (30.0%) the most commonly isolated genus. Concerning outdoor, eighteen species/genera of fungi were isolated, being Scopulariopsis brevicaulis (62.6%) also the most isolated. All the poultry farms analyzed presented indoor fungi different from the ones identified outdoors. Regarding particles’ contamination, PM2.5, PM5.0 and PM10 had a statistically significant difference (Mann-Whitney U test) between the inside and outside of the pavilions, with the inside more contaminated (p=.006; p=.005; p=.005, respectively). The analyzed poultry units are potential reservoirs of substantial amounts of fungi and particles and could therefore free them in the atmospheric air. The developed study showed that indoor air was more contaminated than outdoors, and this can result in emission of potentially pathogenic fungi and particles via aerosols from poultry units to the environment, which may post a considerable risk to public health and contribute to environmental pollution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to contribute to the assessment of exposure levels of ultrafine particles in the urban environment of Lisbon, Portugal, due to automobile traffic, by monitoring lung deposited alveolar surface area (resulting from exposure to ultrafine particles) in a major avenue leading to the town center during late spring, as well as in indoor buildings facing it. Data revealed differentiated patterns for week days and weekends, consistent with PM2.5 and PM10 patterns currently monitored by air quality stations in Lisbon. The observed ultrafine particulate levels may be directly correlated with fluxes in automobile traffic. During a typical week, amounts of ultrafine particles per alveolar deposited surface area varied between 35 and 89.2 μm2/cm3, which are comparable with levels reported for other towns in Germany and the United States. The measured values allowed for determination of the number of ultrafine particles per cubic centimeter, which are comparable to levels reported for Madrid and Brisbane. In what concerns outdoor/indoor levels, we observed higher levels (32 to 63%) outdoors, which is somewhat lower than levels observed in houses in Ontario.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Indoor air quality recently entered legislation in Portugal. Several parameters must be evaluated and kept within limits in order to obtain a certification for air quality and energy consumption. Certification parameters were analyzed in two Portuguese archives in order to assess indoor air quality both for people attending or working on these premises and for maintenance of a written heritage that must be retained for future generations. Carbon monoxide (CO) and carbon dioxide (CO2), formaldehyde, and fungal counts were kept within stipulated limits. Relative humidity (RH), volatile organic compounds (VOC), particulate matter (PM10), and ozone (O3) showed values above legislated levels and justified the implementation of corrective measures. In terms of conservation, studies on the limit values are still needed, but according to the available international guidelines, some of the analyzed parameters such as PM10, O3, and RH were also above desirable values. Corrective measures were proposed to these institutions. Although this study was only of a short duration, it proved valuable in assessing potential eventual problems and constitutes the first Portuguese indoor air quality assessment taking into consideration both aspects of an archive such as human health and heritage safekeeping.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although a great body of literature exists concerning the ingestion of food contaminated with aflatoxin, there are still few studies regarding mycotoxin inhalation in occupational settings. Since mycotoxins are relatively non-volatile, inhalation exposure is cause by inhalation of airborne fungal particulates or fungi-contaminated substrates that contain aflatoxin. We intend to know if there is occupational exposure to aflatoxin in Portuguese poultry and swine production. A total of 19 individuals (11 swine; 8 poultry) agreed and provided blood samples during the course of this investigation. Measurement of AFB1 was performed by ELISA. The samples were treated with pronase (Merck), wash in a Column C18 and purification was made with immunoaffinity columns (R.biopharma), specific for AFB1. It was applied statistical test (Mann-Whitney) to verified statistical difference in AFB1 results between the two settings. Results varied with concentrations from