205 resultados para extracorporeal
Resumo:
Severe acute respiratory failure of varying etiology may require the temporary use of artificial gas exchange devices. So far, extracorporeal membrane oxygenation and extracorporeal carbon dioxide removal have been used successfully for this purpose. A totally implantable intravascular oxygenator (IVOX) recently became available. The authors have used IVOX in three patients who presented with severe respiratory failure secondary to pneumonia (n = 2) and post-traumatic adult respiratory distress syndrome (n = 1). At the time of implantation, all patients had hypoxemia (PaO2 less than 60) despite a 100% inspired oxygen concentration and forced mechanical ventilation. The duration of IVOX therapy ranged from 12 to 71 hr. All patients initially showed improvement in arterial oxygenation, allowing for moderate reduction of ventilator therapy after several hours. In one patient the pulmonary status deteriorated further, and she died from multiple organ failure despite IVOX therapy. One patient could be stabilized but died from other causes. The third patient is a long-term survivor 18 months after IVOX therapy. Gas transfer capabilities of IVOX are limited when compared to extracorporeal membrane oxygenation, and this may restrict its clinical applicability in cases of severe adult respiratory distress syndrome. However, IVOX may be used successfully in selected patients with less severe respiratory failure.
Resumo:
Mediastinal mass syndrome remains an anaesthetic challenge that cannot be underestimated. Depending on the localization and the size of the mediastinal tumour, the clinical presentation is variable ranging from a complete lack of symptoms to severe cardiorespiratory problems. The administration of general anaesthesia can be associated with acute intraoperative or postoperative cardiorespiratory decompensation that may result in death due to tumour-related compression syndromes. The role of the anaesthesiologist, as a part of the interdisciplinary treatment team, is to ensure a safe perioperative period. However, there is still no structured protocol available for perioperative anaesthesiological procedure. The aim of this article is to summarize the genesis of and the diagnostic options for mediastinal mass syndrome and to provide a solid detailed methodology for its safe perioperative management based on a review of the latest literature and our own clinical experiences. Proper anaesthetic management of patients with mediastinal mass syndrome begins with an assessment of the preoperative status, directed foremost at establishing the localization of the tumour and on the basis of the clinical and radiological findings, discerning whether any vital mediastinal structures are affected. We have found it helpful to assign 'severity grade' (using a three-grade clinical classification scale: 'safe', 'uncertain', 'unsafe'), whereby each stage triggers appropriate action in terms of staffing and apparatus, such as the provision of alternatives for airway management, cardiopulmonary bypass and additional specialists. During the preoperative period, we are guided by a 12-point plan that also takes into account the special features of transportation into the operating theatre and patient monitoring. Tumour compression on the airways or the great vessels may create a critical respiratory and/or haemodynamic situation, and therefore the standard of intraoperative management includes induction of anaesthesia in the operating theatre on an adjustable surgical table, the use of short-acting anaesthetics, avoidance of muscle relaxants and maintenance of spontaneous respiration. In the case of severe clinical symptoms and large mediastinal tumours, we consider it absolutely essential to cannulate the femoral vessels preoperatively under local anaesthesia and to provide for the availability of cardiopulmonary bypass in the operating theatre, should extracorporeal circulation become necessary. The benefits of establishing vascular access under local anaesthesia clearly outweigh any associated degree of patient discomfort. In the case of patients classified as 'safe' or 'uncertain', a preoperative consensus with the surgeons should be reached as to the anaesthetic approach and the management of possible complications.
Resumo:
OBJECTIVE: The primary objective of this nationwide survey carried out in department of cardiac anesthesia in Germany was to identify current practice with regard to neuromonitoring und neuroprotection. METHODOLOGY: The data are based on a questionnaire sent out to all departments of cardiac anesthesia in Germany between October 2007 und January 2008. The anonymized questionnaire contained 26 questions about the practice of preoperative evaluation of cerebral vessels, intra-operative use of neuromonitoring, the nature und application of cerebral protective measures, perfusion management during cardiopulmonary bypass, postoperative evaluation of neurological status, and training in the field of cerebral monitoring. RESULTS: Of the 80 mailed questionnaires 55% were returned and 90% of department evaluated cerebral vessels preoperatively with duplex ultrasound. The methods used for intra-operative neuromonitoring are electroencephalography (EEG, 60%) for type A dissections (38.1%), for elective surgery on the thoracic and thoraco-abdominal aorta (34.1% and 31.6%, respectively) and in carotid surgery (43.2%) near infrared spectroscopy (40%), evoked potentials (30%) and transcranial Doppler sonography (17.5%), with some centers using combined methods. In most departments the central nervous system is not subjected to monitoring during bypass surgery, heart valve surgery, or minimally invasive surgery. Cerebral protective measures used comprise patient cooling on cardio-pulmonary bypass (CPB 100%), extracorporeal cooling of the head (65%) and the administration of corticosteroids (58%), barbiturates (50%) and antiepileptic drugs (10%). Neuroprotective anesthesia consists of administering inhalation anesthetics (32.5%; sevoflurane 76.5%) and intravenous anesthesia (20%; propofol and barbiturates each accounting for 46.2%). Of the departments 72.5% cool patients as a standard procedure for surgery involving cardiovascular arrest and 37.5% during all surgery using CPB. In 84.6% of department CPB flow equals calculated cardiac output (CO) under normothermia, while the desired mean arterial pressure (MAP) varies between 60 and 70 mmHg (43.9%) and between 50 and 60 mmHg (41.5%), respectively. At body temperatures less than 18 degrees C CPB flow is reduced below the calculated CO (70%) while 27% of departments use normothermic flow rates. The preferred MAP under hypothermia is between 50 and 60 mmHg (59%). The results of intra-operative neuromonitoring are documented on the anesthesia record (77%). In 42.5% of the departments postoperative neurological function is estimated by the anesthesiologist. Continuing education sessions pertaining to neuromonitoring are organized on a regular basis in 32.5% of the departments and in 37.5% individual physicians are responsible for their own neuromonitoring education. CONCLUSION: The present survey data indicate that neuromonitoring and neuroprotective therapy during CPB is not standardized in cardiac anesthesiology departments in Germany. The systemic use of available methods to implement multimodal neuromonitoring would be desirable.
Resumo:
BACKGROUND Lactic acidosis (LAc) is a common form of metabolic acidosis early after heart transplantation (HTX). The mechanism remains unclear. This study analyzed 13 patients who developed severe LAc after HTX. METHODS From a series of 60 consecutive heart transplant patients, we identified 13 patients with LAc in the first hours following HTX. Nine patients with normal or mildly elevated lactate levels (<5.0 mmol/l) were investigated as controls. RESULTS Thirteen patients developed a moderate or severe LAc (up to 14.6 mmol/l) after HTX. Serum lactate levels increased immediately following surgery with a peak after 6.3+/-1.4 h, spontaneously returning to normal values within 24 h. In contrast to the control group, a significant correlation was found between the maximal serum lactate level and the maximal dosage of inotropic drugs (r=0.93, P<0.02), administered during the reperfusion phase and continued for 12-24 h postoperatively. No correlation was found between LAc and blood gas analysis during extracorporeal perfusion period. CONCLUSION LAc can occur after HTX and seems to be related to the inotropic support of the graft. In contrast to other forms, LAc after HTX has an excellent prognosis and resolves rapidly and spontaneously without treatment. The fact that inotropic support during and immediately after cardiac transplantation can enhance preexisting severe peripheral metabolic cellular dysfunction remains hypothetical.
Resumo:
Inefficient alveolar wound repair contributes to the development of pulmonary fibrosis. Hepatocyte growth factor (HGF) is a potent growth factor for alveolar type II epithelial cells (AECII) and may improve repair and reduce fibrosis. We studied whether targeted gene transfer of HGF specifically to AECII improves lung fibrosis in bleomycin-induced lung fibrosis. A plasmid encoding human HGF expressed from the human surfactant protein C promoter (pSpC-hHGF) was designed, and extracorporeal electroporation-mediated gene transfer of HGF specifically to AECII was performed 7 days after bleomycin-induced lung injury in the rat. Animals were killed 7 days after hHGF gene transfer. Electroporation-mediated HGF gene transfer resulted in HGF expression specifically in AECII at biologically relevant levels. HGF gene transfer reduced pulmonary fibrosis as assessed by histology, hydroxyproline determination, and design-based stereology compared with controls. Our results indicate that the antifibrotic effect of HGF is due in part to a reduction of transforming growth factor-β(1), modulation of the epithelial-mesenchymal transition, and reduction of extravascular fibrin deposition. We conclude that targeted HGF gene transfer specifically to AECII decreases bleomycin-induced lung fibrosis and may therefore represent a novel cell-specific gene transfer technology to treat pulmonary fibrosis.
Resumo:
A 44-year-old male European with type I diabetes mellitus fell into diabetic ketoacidosis. In the emergency room, he developed an episode of asystole and respiratory failure requiring one cycle of cardiopulmonary resuscitation and extracorporeal membrane oxygenation (ECMO). Waking up 7 days later, he presented a bilateral complete loss of vision. Ophthalmological examination including funduscopy on days 1 and 10, after extubation, showed bilateral large round pupils non-reactive to light and a normal fundus. Neuroimaging studies, including MRI and MRA of the brain, were all within normal limits. A lumbar puncture and comprehensive serological testing excluded an infectious or rheumatic cause. An empirical high-dose intravenous steroid treatment administered for 5 days had no effect on his vision. His eye examination at 1.5 months follow-up showed a normal fundus except for progressive bilateral optic nerve disc pallor, which pointed towards the diagnosis of a posterior ischaemic optic neuropathy.
Resumo:
We report a case of massive suicidal overdose of meprobamate leading to cardiovascular collapse, respiratory failure, and severe central nervous system depression. We observed first-order elimination kinetics despite significant overdose, and demonstrated effectiveness of continuous venovenous hemodiafiltration (CVVHDF) for extracorporeal removal of meprobamate in this patient. Total body clearance was calculated to be 87 mL/minute, with 64 mL/minute (74%) due to CVVHDF. CVVHDF was stopped after 36 hours, and the patient made an uneventful recovery.
Resumo:
BACKGROUND: Congenital diaphragmatic hernia (CDH) remains a significant cause of death in newborns. With advances in neonatal critical care and ventilation strategies, survival in the term infant now exceeds 80% in some centers. Although prematurity is a significant risk factor for morbidity and mortality in most neonatal diseases, its associated risk with infants with CDH has been described poorly. We sought to determine the impact of prematurity on survival using data from the Congenital Diaphragmatic Hernia Registry (CDHR). METHODS: Prospectively collected data from live-born infants with CDH were analyzed from the CDHR from January 1995 to July 2009. Preterm infants were defined as <37 weeks estimated gestational age at birth. Univariate and multivariate logistic regression analysis were>performed. RESULTS: During the study period, 5,069 infants with CDH were entered in the registry. Of the 5,022 infants with gestational age data, there were 3,895 term infants (77.6%) and 1,127 preterm infants (22.4%). Overall survival was 68.7%. A higher percentage of term infants were treated with extracorporeal membrane oxygenation (ECMO) (33% term vs 25.6% preterm). Preterm infants had a greater percentage of chromosomal abnormalities (4% term vs 8.1% preterm) and major cardiac anomalies (6.1% term vs 11.8% preterm). Also, a significantly higher percentage of term infants had repair of the hernia (86.3% term vs 69.4% preterm). Survival for infants that underwent repair was high in both groups (84.6% term vs 77.2% preterm). Survival decreased with decreasing gestational age (73.1% term vs 53.5% preterm). The odds ratio (OR) for death among preterm infants adjusted for patch repair, ECMO, chromosomal abnormalities, and major cardiac anomalies was OR 1.68 (95% confidence interval [CI], 1.34-2.11). CONCLUSION: Although outcomes for preterm infants are clearly worse than in the term infant, more than 50% of preterm infants still survived. Preterm infants with CDH remain a high-risk group. Although ECMO may be of limited value in the extremely premature infant with CDH, most preterm infants that live to undergo repair will survive. Prematurity should not be an independent factor in the treatment strategies of infants with CDH.
Resumo:
BACKGROUND: Whole-body hypothermia reduced the frequency of death or moderate/severe disabilities in neonates with hypoxic-ischemic encephalopathy in a randomized, controlled multicenter trial. OBJECTIVE: Our goal was to evaluate outcomes of safety and effectiveness of hypothermia in infants up to 18 to 22 months of age. DESIGN/METHODS: A priori outcomes were evaluated between hypothermia (n = 102) and control (n = 106) groups. RESULTS: Encephalopathy attributable to causes other than hypoxia-ischemia at birth was not noted. Inotropic support (hypothermia, 59% of infants; control, 56% of infants) was similar during the 72-hour study intervention period in both groups. Need for blood transfusions (hypothermia, 24%; control, 24%), platelet transfusions (hypothermia, 20%; control, 12%), and volume expanders (hypothermia, 54%; control, 49%) was similar in the 2 groups. Among infants with persistent pulmonary hypertension (hypothermia, 25%; control, 22%), nitric-oxide use (hypothermia, 68%; control, 57%) and placement on extracorporeal membrane oxygenation (hypothermia, 4%; control, 9%) was similar between the 2 groups. Non-central nervous system organ dysfunctions occurred with similar frequency in the hypothermia (74%) and control (73%) groups. Rehospitalization occurred among 27% of the infants in the hypothermia group and 42% of infants in the control group. At 18 months, the hypothermia group had 24 deaths, 19 severe disabilities, and 2 moderate disabilities, whereas the control group had 38 deaths, 25 severe disabilities, and 1 moderate disability. Growth parameters were similar between survivors. No adverse outcomes were noted among infants receiving hypothermia with transient reduction of temperature below a target of 33.5 degrees C at initiation of cooling. There was a trend in reduction of frequency of all outcomes in the hypothermia group compared with the control group in both moderate and severe encephalopathy categories. CONCLUSIONS: Although not powered to test these secondary outcomes, whole-body hypothermia in infants with encephalopathy was safe and was associated with a consistent trend for decreasing frequency of each of the components of disability.
Resumo:
The recently introduced rabbit blood shunt subarachnoid haemorrhage model is based on the two standard procedures of subclavian artery cannulation and transcutaneous cisterna magna puncture. An extracorporeal shunt placed in between the arterial system and the subarachnoid space allows examiner-independent SAH in a closed cranium. Despite its straightforwardness, it is worth examining some specific features and characteristics of the model. We outline technical considerations to successfully perform the model with minimal mortality and morbidity. In addition, we discuss outcome measures, advantages and limitations, and the applicability of the model for the study of early brain injury and delayed cerebral vasospasm after SAH.
Resumo:
BACKGROUND The activation of multiple pro- and anti-inflammatory mediators is a key feature in the pathophysiology of sepsis. Many of these mediators may directly contribute to organ dysfunction and determine disease severity. So far our ability to modulate these upregulated mediator pathways is very limited. Therefore the adsorption of such mediators via an extracorporeal circuit may be a beneficial intervention during sepsis. OBJECTIVES Recent technical innovations have made this intervention feasible. Both systems for exclusive mediator adsorption and for adsorption beside a conventional renal replacement therapy are now available. Some of the membranes can adsorb a broad range of mediators by rather unspecific binding, whereas others specifically adsorb endotoxin or mediators. DISCUSSION Whilst biochemical efficacy could be demonstrated by some of the systems, controlled and randomized studies demonstrating improved clinical endpoints are still lacking. Therefore the use of such therapies outside clinical studies cannot yet be recommended.
Resumo:
BACKGROUND The Perceval (Sorin Group, Milan, Italy) is a self-anchoring sutureless aortic valve prosthesis. We report the short- to midterm results of combined aortic valve replacement (AVR) with concomitant procedures in elderly patients undergoing operation as part of 3 consecutive prospective multicenter European studies. METHODS From April 2007 to February 2013, 243 patients (mean age, 79.7 ± 5.1 years; female patients, 61%; median EuroSCORE, 9%) underwent AVR with concomitant procedures. The concomitant procedures were coronary artery bypass grafting (CABG) (182 cases), septal myectomy (21 cases), CABG + other procedures (18 cases), and 22 other procedures. Primary and secondary end points included implant feasibility and safety (for mortality and morbidity) and efficacy (New York Heart Association [NYHA] class improvement and hemodynamic results) of the prosthesis at the different follow-up periods. Data were expressed as mean ± standard deviation. Kaplan-Meier analysis was performed for survival analysis. RESULTS Mean aortic cross-clamp and extracorporeal circulation (ECC) times were 50.7 ± 22.8 minutes and 78.9 ± 32.3 minutes, respectively. Thirty-day mortality was 2.1%. Mean postoperative gradient and effective orifice area were 10.1 ± 4.7 mm Hg and 1.5 ± 0.4 cm(2) and 8.9 ± 5.6 mm Hg and 1.6 ± 0.4 cm(2), respectively, at 1 year. There were early explantations, 4 of which resulted from paravalvular leaks. One additional valve explantation resulted from aortic root bleeding, probably caused by excessively extensive decalcification. In the late period, there was 1 mild paravalvular leak and no intravalvular insufficiency. No migration, dislodgement, or degeneration of the valve occurred during follow-up. Median follow-up was 444 days. CONCLUSIONS These trials confirm the safety and efficacy of the Perceval sutureless aortic valve, especially in elderly patients requiring AVR + concomitant procedures. In this patient group, sutureless valves may be advantageous compared to transcatheter valve implantations as concomitant procedures other than percutaneous coronary artery angioplasty are not always possible in the latter.
Resumo:
OBJECTIVES Oxygenation of blood and other physiological solutions are routinely required in fundamental research for both in vitro and in vivo experimentation. However, very few oxygenators with suitable priming volumes (<2-3 ml) are available for surgery in small animals. We have designed a new, miniaturized membrane oxygenator and investigated the oxygen-transfer performance using both buffer and blood perfusates. METHODS The mini-oxygenator was designed with a central perforated core-tube surrounded by parallel-oriented microporous polypropylene hollow fibres, placed inside a hollow shell with a lateral-luer outlet, and sealed at both extremities. With this design, perfusate is delivered via the core-tube to the centre of the mini-oxygenator, and exits via the luer port. A series of mini-oxygenators were constructed and tested in an in vitro perfusion circuit by monitoring oxygen transfer using modified Krebs-Henseleit buffer or whole porcine blood. Effects of perfusion pressure and temperature over flows of 5-60 ml × min(-1) were assessed. RESULTS Twelve mini-oxygenators with a mean priming volume of 1.5 ± 0.3 ml were evaluated. With buffer, oxygen transfer reached a maximum of 14.8 ± 1.0 ml O2 × l(-1) (pO2: 450 ± 32 mmHg) at perfusate flow rates of 5 ml × min(-1) and decreased with an increase in perfusate flow to 7.8 ± 0.7 ml ml O2 × l(-1) (pO2: 219 ± 24 mmHg) at 60 ml × min(-1). Similarly, with blood perfusate, oxygen transfer also decreased as perfusate flow increased, ranging from 33 ± 5 ml O2 × l(-1) at 5 ml × min(-1) to 11 ± 2 ml O2 × l(-1) at 60 ml × min(-1). Furthermore, oxygen transfer capacity remained stable with blood perfusion over a period of at least 2 h. CONCLUSIONS We have developed a new miniaturized membrane oxygenator with an ultra-low priming volume (<2 ml) and adequate oxygenation performance. This oxygenator may be of use in overcoming current limitations in equipment size for effective oxygenation in low-volume perfusion circuits, such as small animal extracorporeal circulation and ex vivo organ perfusion.
Resumo:
Die Nierenersatztherapie ist eine der erfolgreichsten Geschichten eines künstlichen Organersatzes. Der vorliegende Artikel beschreibt die wichtigsten Schritte in der Evolution zur modernen Therapie mit Peritonealdialyse und Hämodialyse. Aktuelle Fragen im Bereich der Nierenersatztherapie werden diskutiert und zukünftige Entwicklungen aufgezeigt. Dem Patienten stehen heute diverse Therapiemöglichkeiten offen. Allerdings nur, wenn er mindestens ein halbes Jahr vor der Notwendigkeit eines Therapiebeginns die für ihn ideale Therapieform auswählen kann. Verspätete Zuweisungen und die Notwendigkeit eines akuten Dialysebeginns führen nicht nur zu einer erhöhten Mortalität, sondern auch dazu, dass eine präemptive Lebendnierentransplantation verunmöglicht wird. Zudem bleiben diese Patienten in der Regel im Dialysezentrum und können für eine Heimbehandlung, sei es nun in Form einer Peritonealdialyse oder Heimhämodialyse, nicht mehr motiviert werden.
Resumo:
Gebiet: Chirurgie Biomedizintechnik Biophysik Transplantationsmedizin Kardiologie Abstract: OBJECTIVES: – Oxygenation of blood and other physiological solutions are routinely required in fundamental research for both in vitro and in vivo experimentation. However, very few oxygenators with suitable priming volumes (<2-3 ml) are available for surgery in small animals. We have designed a new, miniaturized membrane oxygenator and investigated the oxygen-transfer performance using both buffer and blood perfusates. – – METHODS: – The mini-oxygenator was designed with a central perforated core-tube surrounded by parallel-oriented microporous polypropylene hollow fibres, placed inside a hollow shell with a lateral-luer outlet, and sealed at both extremities. With this design, perfusate is delivered via the core-tube to the centre of the mini-oxygenator, and exits via the luer port. A series of mini-oxygenators were constructed and tested in an in vitro perfusion circuit by monitoring oxygen transfer using modified Krebs-Henseleit buffer or whole porcine blood. Effects of perfusion pressure and temperature over flows of 5-60 ml × min(-1) were assessed. – – RESULTS: – Twelve mini-oxygenators with a mean priming volume of 1.5 ± 0.3 ml were evaluated. With buffer, oxygen transfer reached a maximum of 14.8 ± 1.0 ml O2 × l(-1) (pO2: 450 ± 32 mmHg) at perfusate flow rates of 5 ml × min(-1) and decreased with an increase in perfusate flow to 7.8 ± 0.7 ml ml O2 × l(-1) (pO2: 219 ± 24 mmHg) at 60 ml × min(-1). Similarly, with blood perfusate, oxygen transfer also decreased as perfusate flow increased, ranging from 33 ± 5 ml O2 × l(-1) at 5 ml × min(-1) to 11 ± 2 ml O2 × l(-1) at 60 ml × min(-1). Furthermore, oxygen transfer capacity remained stable with blood perfusion over a period of at least 2 h. – – CONCLUSIONS: – We have developed a new miniaturized membrane oxygenator with an ultra-low priming volume (<2 ml) and adequate oxygenation performance. This oxygenator may be of use in overcoming current limitations in equipment size for effective oxygenation in low-volume perfusion circuits, such as small animal extracorporeal circulation and ex vivo organ perfusion. – – © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.