971 resultados para dental prosthesis design


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The population’s life expectancy is growing every year. This fact highlights the importance of the elderly for the dentistry. The oral cavity quality has great influence on quality of life at both the biological and the psychological and social factors by maintaining a self-esteem, self-expression, communication and satisfactory facial aesthetics. Unfortunately, the number of edentulous elderly population is also high, which may create problems to their social life. Therefore, the objective of this study was to demonstrate and evaluate the difficulties of treating edentulous patients, comparing data prior to treatment to post data after treatment by complete dentures made to the patients undergoing oral rehabilitation in the Dental Clinic of the Faculty of Dentistry of Adamantina – FAI. For this study, questionnaires were filled in the form of answers developed alternative focused on the degree of patient satisfaction, the current situation of occlusion, and outcome of treatment. The results showed that 96% of patients were satisfied with the results obtained in the treatment, all of whom believed that the prosthesis helped them feel better aesthetically and improved self-esteem. By this methodology, it was concluded that the degree of satisfaction was high, but the services provided must be constantly reevaluated, once the elderly population presents a wide labor market for dental professionals and demand level services will certainly increase each year.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The use of implants of greater length may be more favorable for the predictability of dental implants. This statement is relevant, since the cause of failures in dental implants are more related to biomechanical complications. The aim of this study was to evaluate the influence of increase of the length around the entire body of the implant. Six models were created with the presence of only one hexagonal implant (Master Screw connection, Implant Systems, São Paulo, Brazil) of 3.75 mm x 7.0 mm (Model A), 3.75 mm x 8.5 mm (Model B ), 3.75 mm x 10.0 mm (Model C) 3.75 mm x 11.5 mm (Model D) 3.75 mm x 13.0 mm (Model E) 3.75 mm x 15.0 mm (Model F) using the method of photoelasticity. The results were visualized through a qualitative analysis of stresses (number and intensity photoelastic fringes). The model A showed a pattern of less favorable stress distribution, the oblique loading was the most detrimental to the related structures. Conclusion: The increased length allowed for a better distribution of stresses. The oblique loading was more detrimental when compared to axial loading.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to evaluate the biomechanical behavior of different implant connection types, by means of three-dimensional finite element analysis. 3 Three-dimensional models were created with a graphic modeling software: SolidWorks 2006 and Rhinoceros 4.0, and InVesalius (CTI, São Paulo, Brasil), the bone was obtained by computerized tomography of a sagittal section of the molar region. The model was composed by bone block with an implant (4 x 10 mm) (Conexão Sistemas de Prótese, São Paulo), with different implant connections: external hex, internal hex and Morse-taper with the corresponding prosthetic component Ucla or Morse-taper abutment. The Three-dimensional models were transferred to finite element software Femap 10.0 (Siemens PLM Software Inc., CA, USA), to generate a mesh, boundary conditions and loading. An axial (200N) and oblique load (100N) was applied on the occlusal surface of the crowns. Analyses were performed using the finite element software NEiNastran 9.0 (Noran Engineering, Inc., USA) and transferred to the Femap 10.0 to obtain the results; after the results were visualized using von Mises stress maps and Maximum stress principal. The results showed the stress distribution was similar between models, with a little superiority of Morse-taper connection. It was concluded that: the three connection types were biomechanical viable; The Morse-taper connection presented the better internal stress distribution; there was not significant biomechanical differences on the bone.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The concept of switching platform is the use of an implant by platform wider than the abutment. Recently, researches have shown that this type of dental implant design tends to offer a higher preservation of crestal bone when compared to the traditional pattern of bone loss. The present study aims to perform a critical review on the switching platform concept establishing possible advantages of the technique. A search was performed on Medline/Pubmed about the topic “dental implant” and “platform switching”, and after applying inclusion criteria 40 studies were selected. The literature on longevity present prospective studies that show less bone loss, studies in biomechanics exhibit better or similar stress distribution around the bone crest, however, is not yet defined the role of the biological width. Thus, studies of longevity, and randomized prospective studies are of a great relevance to be performed in order to confirm the benefits of this technique and to establish a protocol indication. It is possible, based on this literature review, to conclude that longitudinal and randomized studies show that the platform switching implants have longevity and less bone loss. Biomechanically, the technique is possible.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Sometimes we face clinical situations in which the lack of harmony in the smile is caused by a major exhibition of the gingival tissue. In these cases the professional should be able to perform a detailed analysis of the static and dynamic components of the smile, in search of a satisfactory planning and treatment which may include different dental specialties. For these situations, the association of periodontics/prosthesis is a viable alternative that has been used positively in search of an aesthetic and functional condition that benefits the patient, without leaving aside the preservation of periodontal tissues and of the remaining structure of the tooth. Thus, the aim of this study was to describe a case in which the association between these two areas was proposed to correct gummy smile and dental vestibularization. Clinical results and the satisfaction of the patient indicate that this multidisciplinary treatment combining periodontal and prosthetic techniques is favorable to positive results in cases of compromised smile aesthetics due to excessive gum tissue.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Nowadays the search for aesthetic in removable dentures is considered a success clinical factor. Besides, both the selection of artificial denture teeth and the characterization of dentures have been based on the facial harmony and cultural factors. But these factors change over time. Therefore, the present study aimed to discuss the selection of artificial denture teeth in relation to patient’s variables such as face shape, skin color, hair color, eye color, age and gender. Moreover, artificial denture teeth’ color, shape and size were presented.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: The use of methods for tissue regeneration has been widely applied in Implantology, in clinical situations with disabilities or anatomical limitations that prevent the placement of osseointegrated dental implants. The evolution of the development of biomaterials revolutionized this therapeutic modality, facilitating the resolution of clinical cases with tissue deficiencies. Thus, this study aimed to describe a clinical case approaching the methods, techniques, and materials used in guided bone regeneration applied to Implantology. Case report: A clinical case of a patient who received a Morse taper dental implant (region 15) is described. The use of biomaterial and membrane on the buccal wall of the socket was required. After the osseointegration period, a reopening surgery was performed, and an immediate provisional implant was produced. After 2 months of follow-up, the final prosthesis was made involving other adjacent elements. Final considerations: The guided bone regeneration technique employed showed satisfactory performance. The patient was positive regarding esthetics and function. However, more controlled studies with longer follow-up period are needed for analyses of predictability

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: the aim of this study was to evaluate the influence of occlusal veneering material in single fixed implant-supported crowns through the 3-D finite element method. Material and methods: Four models were fabricated using the Rhinoceros 4.0, SolidWorks, and InVesalius softwares. Each model represented a block of mandibular bone with an external hexagon implant of 5 mm x 10 mm and different veneering materials including NiCr (1), porcelain (2), composite resin (3), and acrylic resin (4). An axial load of 200 N and an oblique load of 100 N were applied. Results: model (2) with porcelain veneering presented a lower stress concentration for the NiCr framework, followed by the composite resin and acrylic resin. The stress distribution to the implant and bone tissue was similar for all models. Conclusions: there is no difference of stress distribution to the implant and supporting structures by varying the veneering material of a single implant-supported prosthesis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: the aim of this study was to evaluate the influence of occlusal veneering material in single fixed implant-supported crowns through the 3-D finite element method. Material and methods: Four models were fabricated using the Rhinoceros 4.0, SolidWorks, and InVesalius softwares. Each model represented a block of mandibular bone with an external hexagon implant of 5 mm x 10 mm and different veneering materials including NiCr (1), porcelain (2), composite resin (3), and acrylic resin (4). An axial load of 200 N and an oblique load of 100 N were applied. Results: model (2) with porcelain veneering presented a lower stress concentration for the NiCr framework, followed by the composite resin and acrylic resin. The stress distribution to the implant and bone tissue was similar for all models. Conclusions: there is no difference of stress distribution to the implant and supporting structures by varying the veneering material of a single implant-supported prosthesis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The evolution of ceramic systems currently allows the manufacture of prosthesis similar to the natural teeth, meeting the expectations of patients. However, when using vitreous ceramic the color of substrate is significant for the esthetic result, requiring planning aesthetic cores when involved reconstruction of endodontically treated teeth without coronal structure. Thus, the aim of this study to describe a case report of aesthetic rehabilitation in upper anterior teeths using vitreous ceramic system for the reconstruction of elements: 11, 12, 21 and 22 after endodontically treated. It was emphasized the removal of crowns and manufacture of custom cast post and core with ceramic in coronal portion, prioritizing the aesthetic result. Through the clinical results observed can be seen that the use of custom cast post and core with ceramic in association lithium disilicate glass ceramics provided a satisfactory aesthetic result.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to review the literature in order to discuss the main and the most effective therapeutic activities to control the nocturnal bruxism. To identify the studies included in this review, it was conducted a detailed and advanced search strategy in the PubMed and Medline databases. It was used as KEY WORDS: bruxism, therapeutics and drug therapy. Inclusion criteria were: case reports, randomized controlled trials, in vitro studies, literature reviews and systematic reviews with or without meta-analysis of the past 10 years that addressed the theme. Exclusion criteria were: articles without abstract, animal studies, articles whose first language was not English and articles from journals that do not belong to the dentario field. From a total of 83 articles, after an analysis according to the inclusion and exclusion criteria, 33 articles were selected. Despite the fact that there is a small number of prospective clinical studies with high degree of reliability and most studies that evaluated the alternative treatments effectiveness are isolated case reports, the current literature shows that the use of botulinum toxin has been shown to be effective in the control of nocturnal bruxism. On the other hand, important aspects such as transitory effect, safe dosage and application technique are still little discussed, then, further studies are needed to have these doubts clarified.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Osseointegrated implants have specific nature distinguish them from natural teeth making them more susceptible to the efforts generated by mastication. The absence of periodontal ligament, which absorbs the masticatory forces and allows the movement of the teeth interfere with the reception of occlusal loads and therefore the predictability of implants. In the boneimplant interface did not occur the phenomena of dissipation of impact, even the movement induced. Thus, during planning and installation of implant prosthesis, the type and characteristics of occlusal pattern adopted should be established with criteria to be no grounds for future failures. In this regard we highlight the occlusal overload generated by several reasons like the presence of premature contacts, interference during motion excursive, deleterious habits and inappropriate extensions on cantilevers. Thus, the objective is to provide a review of the literature regarding the importance of occlusion in oral rehabilitation with implants. Factors to be considered in establishing a favorable occlusion, consistent with prostheses on implants will be described

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In part I of this article, the factors related to the establishment of a favourable occlusion for the implant prosthodontics as well as its real importance in this kind of rehabilitation were showed up. However, it is known that the occlusal characteristics adopted in implant prosthodontics show specific patterns which must be different between each other in accordance to the type of prosthesis installed. The objective of the second part of this work is to present to the reader, by a literature review, those characteristics, justifying the reason because they must be associated to specific kind of prosthesis for favor the treatment established.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)