934 resultados para corneal oedema


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To determine whether the scleral stroma is affected as much as the corneal stroma in keratoconus. SETTING University Eye Clinic, Bern, Switzerland. DESIGN Comparative case-control study. METHODS Eyes with keratoconus (keratoconus group) and eyes of age-, sex-, and axial length-matched controls (control group) were analyzed. Corneal videokeratometry and pachymetry were performed using a Scheimpflug tomographer (Pentacam). For measurements of the peripheral cornea and the anterior sclera, a spectral-domain anterior segment optical coherence tomography device (Spectralis) was used. RESULTS The study group comprised 51 eyes and the control group, 50 eyes. The mean central corneal thickness in the keratoconus group was statistically significantly lower than in the control group (447.8 μm ± 57.8 [SD] versus 550.5 ± 35.5 μm) (P < .0001). No significant difference in the mean anterior scleral thickness was found between the keratoconus group and the control group (479.1 ± 43.7 μm versus 474.2 ± 43.0 μm) (P =.57). CONCLUSION Although corneal thinning was observed in keratoconus patients, the anterior scleral stroma thickness in these patients seemed to be similar to that in healthy control eyes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The cornea of the human eye can develop deposits of lipids in the periphery known as corneal arcus. [2, 10] For over a century, these deposits have been of interest as possible indicators of the accumulation of lipids in arterial walls of the heart and body with implications for heart disease. [2, 10, 11, 29] Heart disease is currently the leading cause of death in this country. [5, 29] There have been several publications suggesting an association between the development of atherosclerotic lesions and corneal arcus. [2, 12, 29] Investigators have differed in their interpretation of the relevance of corneal arcus to coronary heart disease or cardiovascular disease. However, there is widespread consensus that the presence of corneal arcus in patients under the age of 50 should prompt physicians to further investigate for dyslipidemia or heart disease. [2, 3, 6, 8, 19] Earlier studies have often suffered from difficulty in determining the presence or severity of atherosclerosis and from inconsistencies in evaluating corneal arcus. This study involves the review of mortality data, medical and social history and standardized slit lamp examination of corneal tissue donors to evaluate the prevalence of corneal arcus in relation to death by CHD or CVD. The prevalence of arcus, odds ratio, and logistic regression was utilized for statistical analysis.^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To evaluate the effect of the vitreomacular interface (VMI) on treatment efficacy of intravitreal therapy in uveitic cystoid macular oedema (CME). METHODS Retrospective analysis of CME resolution, CME recurrence rate and monthly course of central retinal thickness (CRT), retinal volume (RV) and best corrected visual acuity (BCVA) after intravitreal injection with respect to the VMI configuration on spectral-domain OCT using chi-squared test and repeated measures anova adjusted for confounding covariates epiretinal membrane, administered drug and subretinal fluid. RESULTS Fifty-nine eyes of 53 patients (mean age: 47.4 ± 16.9 years) were included. VMI status had no effect on complete CME resolution rate (p = 0.16, corrected p-value: 0.32), time until resolution (p = 0.09, corrected p-value: 0.27) or CME relapse rate (p = 0.29, corrected p-value: 0.29). Change over time did not differ among the VMI configuration groups for BVCA (p = 0.82) and RV (p = 0.18), but CRT decrease was greater and faster in the posterior vitreous detachment (PVD) group compared to the posterior vitreous attachment (PVA) and vitreous macular adhesion (VMA) groups (p = 0.04). Also, the percentage of patients experiencing a ≥ 20% CRT thickness decrease after intravitreal injection was greater in the PVD group (83%) compared to the VMA (64%) and the PVA (16%) group (p = 0.027), however, not after correction for multiple testing (corrected p-value: 0.11). CONCLUSION The VMI configuration seems to be a factor contributing to treatment efficacy in uveitic CME in terms of CRT decrease, although BCVA outcome did not differ according to VMI status.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previously, we identified the heavy chain of ferritin as a developmentally regulated nuclear protein of embryonic chicken corneal epithelial cells. The nuclear ferritin is assembled into a supramolecular form indistinguishable from the cytoplasmic form of ferritin found in other cell types and thus most likely has iron-sequestering capabilities. Free iron, via the Fenton reaction, is known to exacerbate UV-induced and other oxidative damage to cellular components, including DNA. Since corneal epithelial cells are constantly exposed to UV light, we hypothesized that the nuclear ferritin might protect the DNA of these cells from free radical damage. To test this possibility, primary cultures of cells from corneal epithelium and stroma, and from skin epithelium and stroma, were UV irradiated, and DNA strand breaks were detected by an in situ 3′-end labeling method. Corneal epithelial cells without nuclear ferritin were also examined. We observed that the corneal epithelial cells with nuclear ferritin had significantly less DNA breakage than other cell types examined. Furthermore, increasing the iron concentration of the culture medium exacerbated the generation of UV-induced DNA strand breaks in corneal and skin fibroblasts, but not in the corneal epithelial cells. Most convincingly, corneal epithelial cells in which the expression of nuclear ferritin was inhibited became much more susceptible to UV-induced DNA damage. Therefore, it seems that corneal epithelial cells have evolved a novel, nuclear ferritin-based mechanism for protecting their DNA against UV damage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ability of the cornea to transmit light while being mechanically resilient is directly attributable to the formation of an extracellular matrix containing orthogonal sheets of collagen fibrils. The detailed structure of the fibrils and how this structure underpins the mechanical properties and organization of the cornea is understood poorly. In this study, we used automated electron tomography to study the three-dimensional organization of molecules in corneal collagen fibrils. The reconstructions show that the collagen molecules in the 36-nm diameter collagen fibrils are organized into microfibrils (≈4-nm diameter) that are tilted by ≈15° to the fibril long axis in a right-handed helix. An unexpected finding was that the microfibrils exhibit a constant-tilt angle independent of radial position within the fibril. This feature suggests that microfibrils in concentric layers are not always parallel to each other and cannot retain the same neighbors between layers. Analysis of the lateral structure shows that the microfibrils exhibit regions of order and disorder within the 67-nm axial repeat of collagen fibrils. Furthermore, the microfibrils are ordered at three specific regions of the axial repeat of collagen fibrils that correspond to the N- and C-telopeptides and the d-band of the gap zone. The reconstructions also show macromolecules binding to the fibril surface at sites that correspond precisely to where the microfibrils are most orderly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Póster presentado en SPIE Photonics Europe, Brussels, 16-19 April 2012.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Póster presentado en EDULEARN12, International Conference on Education and New Learning Technologies, Barcelona, 2nd-4th July 2012.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reverse engineering is the process of discovering the technological principles of a device, object or system through analysis of its structure, function, and operation. From a device used in clinical practice, as the corneal topographer, reverse engineering will be used to infer physical principles and laws. In our case, reverse engineering involves taking this mechanical device apart and analyzing its working detail. The initial knowledge of the application and usefulness of the device provides a motivation that, together with the combination of theory and practice, will help the students to understand and learn concepts studied in different subjects in the Optics and Optometry degree. These subjects belong to both the core and compulsory subjects of the syllabus of first and second year of the degree. Furthermore, the experimental practice is used as transverse axis that relates theoretical concepts, technology transfer and research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resumen de la presentación oral en el 6th EOS Topical Meeting on Visual and Physiological Optics (EMVPO 2012), Dublín, 20-22 Agosto 2012.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Presentación oral realizada en el 6th EOS Topical Meeting on Visual and Physiological Optics (EMVPO 2012), Dublín, 20-22 Agosto 2012.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To validate clinically an algorithm for correcting the error in the keratometric estimation of corneal power by using a variable keratometric index of refraction (nk) in a normal healthy population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present an algorithm to process images of reflected Placido rings captured by a commercial videokeratoscope. Raw data are obtained with no Cartesian-to-polar-coordinate conversion, thus avoiding interpolation and associated numerical artifacts. The method provides a characteristic equation for the device and is able to process around 6 times more corneal data than the commercial software. Our proposal allows complete control over the whole process from the capture of corneal images until the computation of curvature radii.