830 resultados para computer holography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Positron emission computed tomography (PET) is a functional, noninvasive method for imaging regional metabolic processes that is nowadays most often combined to morphological imaging with computed tomography (CT). Its use is based on the well-founded assumption that metabolic changes occur earlier in tumors than morphologic changes, adding another dimension to imaging. This article will review the established and investigational indications and radiopharmaceuticals for PET/CT imaging for prostate cancer, bladder cancer and testicular cancer, before presenting upcoming applications in radiation therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Computer-Aided Tomography Angiography (CTA) images are the standard for assessing Peripheral artery disease (PAD). This paper presents a Computer Aided Detection (CAD) and Computer Aided Measurement (CAM) system for PAD. The CAD stage detects the arterial network using a 3D region growing method and a fast 3D morphology operation. The CAM stage aims to accurately measure the artery diameters from the detected vessel centerline, compensating for the partial volume effect using Expectation Maximization (EM) and a Markov Random field (MRF). The system has been evaluated on phantom data and also applied to fifteen (15) CTA datasets, where the detection accuracy of stenosis was 88% and the measurement accuracy was with an 8% error.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: Surgical ablation procedures for treating atrial fibrillation have been shown to be highly successful. However, the ideal ablation pattern still remains to be determined. This article reports on a systematic study of the effectiveness of the performance of different ablation line patterns. METHODS AND RESULTS: This study of ablation line patterns was performed in a biophysical model of human atria by combining basic lines: (i) in the right atrium: isthmus line, line between vena cavae and appendage line and (ii) in the left atrium: several versions of pulmonary vein isolation, connection of pulmonary veins, isthmus line, and appendage line. Success rates and the presence of residual atrial flutter were documented. Basic patterns yielded conversion rates of only 10-25 and 10-55% in the right and the left atria, respectively. The best result for pulmonary vein isolation was obtained when a single closed line encompassed all veins (55%). Combination of lines in the right/left atrium only led to a success rate of 65/80%. Higher rates, up to 90-100%, could be obtained if right and left lines were combined. The inclusion of a left isthmus line was found to be essential for avoiding uncommon left atrial flutter. CONCLUSION: Some patterns studied achieved a high conversion rate, although using a smaller number of lines than those of the Maze III procedure. The biophysical atrial model is shown to be effective in the search for promising alternative ablation strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper presents a method of analyzing Rigid Frames by use of the Conjugate Beam Theory. The development of the method along with an example is given. This method has been used to write a computer program for the analysis of twin box culverts. The culverts may be analyzed under any fill height and any of the standard truck loadings. The wall and slab thickness are increased by the computer program as necessary. The final result is steel requirements both for moment and shear, and the slab and wall thickness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on the study of nonequilibrium ordering in the reaction-diffusion lattice gas. It is a kinetic model that relaxes towards steady states under the simultaneous competition of a thermally activated creation-annihilation $(reaction$) process at temperature T, and a diffusion process driven by a heat bath at temperature T?T. The phase diagram as one varies T and T, the system dimension d, the relative priori probabilities for the two processes, and their dynamical rates is investigated. We compare mean-field theory, new Monte Carlo data, and known exact results for some limiting cases. In particular, no evidence of Landau critical behavior is found numerically when d=2 for Metropolis rates but Onsager critical points and a variety of first-order phase transitions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a computer-simulation study of the effect of the distribution of energy barriers in an anisotropic magnetic system on the relaxation behavior of the magnetization. While the relaxation law for the magnetization can be approximated in all cases by a time logarithmic decay, the law for the dependence of the magnetic viscosity with temperature is found to be quite sensitive to the shape of the distribution of barriers. The low-temperature region for the magnetic viscosity never extrapolates to a positive no-null value. Moreover our computer simulation results agree reasonably well with some recent relaxation experiments on highly anisotropic single-domain particles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents SiMR, a simulator of the Rudimentary Machine designed to be used in a first course of computer architecture of Software Engineering and Computer Engineering programmes. The Rudimentary Machine contains all the basic elements in a RISC computer, and SiMR allows editing, assembling and executing programmes for this processor. SiMR is used at the Universitat Oberta de Catalunya as one of the most important resources in the Virtual Computing Architecture and Organisation Laboratory, since students work at home with the simulator and reports containing their work are automatically generated to be evaluated by lecturers. The results obtained from a survey show that most of the students consider SiMR as a highly necessary or even an indispensable resource to learn the basic concepts about computer architecture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study is to clinically validate a new two-dimensional preoperative planning software for cementless total hip arthroplasty (THA). Manual and two-dimensional computer-assisted planning were compared by an independent observer for each of the 30 patients with osteoarthritis who underwent THA. This study showed that there were no statistical differences between the results of both preoperative plans in terms of stem size and neck length (<1 size) and hip rotation center position (<5 mm). Two-dimensional computer-assisted preoperative planning provided successful results comparable to those using the manual procedure, thereby allowing the surgeon to simulate various stem designs easily.