895 resultados para colonic replacement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To determine whether valganciclovir 450 mg every 48 h for cytomegalovirus (CMV) prophylaxis provides appropriate ganciclovir exposure in solid organ transplant recipients during continuous renal replacement therapy (CRRT). PATIENTS AND METHODS: Ganciclovir pharmacokinetics was intensively studied in two lung transplant recipients under valganciclovir 450 mg every 48 h over one dosing interval. In vitro experiments using blank whole blood spiked with ganciclovir further investigated exchanges between plasma and erythrocytes. RESULTS: Ganciclovir disposition was characterized by apparent total body clearance of 3.3 and 5.8 L/h, terminal half-life of 16.9 and 14.1 h, and apparent volume of distribution of 60.3 and 104.9 L in Patients 1 and 2, respectively. The observed sieving coefficient was 1.05 and 0.96, and the haemofiltration clearance was 3.3 and 3.1 L/h. In vitro experiments confirmed rapid efflux of ganciclovir from red blood cells into plasma, increasing the apparent efficacy of haemofiltration. CONCLUSIONS: A valganciclovir dosage of 450 mg every 48 h appears adequate for patients under CRRT requiring prophylaxis for CMV infection, providing concentration levels in the range reported for 900 mg once daily dosing outside renal failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The literature suggests that intraoperative fractures of the greater trochanter and the metaphysis are increased with uncemented stems and the direct anterior approach. This study aims to determine the incidence and assess the functional and radiological outcome after such fractures. METHODS: 484 consecutive total hip replacements (THR) (64 ± 12 years) were analyzed. We treated trochanteric fractures conservatively without any further denuding, and secured metaphyseal fissures with cerclages. Postoperative X-rays and at the latest follow-up were compared to assess secondary fracture displacement and stem subsidence. Western Ontario and McMaster Universities Arthritis Index (WOMAC) scores after 1 year were analyzed. For each patient sustaining a fracture, two patients without fractures were matched in terms of age, body mass index and gender. RESULTS: 13 (2.7 %, 5 male, 68 ± 9 years) patients with intraoperative fractures of the greater trochanter (n = 8) or the metaphysis (n = 5) were analyzed. Consolidation was observed in 7/8 patients sustaining a trochanteric fracture while secondary displacement of the fragment occurred in one case. Stem subsidence was observed in 2/5 cases (5 and 7 mm). Patients who sustained a fracture showed a trend towards poorer WOMAC scores at 1 year postoperatively, compared to patients without fractures. A significantly increased joint stiffness was also observed. CONCLUSION: The intraoperative fracture risk in this series of THR through a direct anterior approach was 2.7 %. Trochanteric fractures do heal without primary fixation. Metaphyseal fractures heal well if immediately stabilized with a cerclage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous studies assessed the outcome of ankle arthrodesis (AA) and total ankle replacement (TAR) surgeries; however, the extent of postoperative recovery towards bilateral gait mechanics (BGM) is unknown. We evaluated the outcome of the two surgeries at least 2 years post rehabilitation, focusing on BGM. 36 participants, including 12 AA patients, 12 TAR patients, and 12 controls were included. Gait assessment over 50 m distance was performed utilizing pressure insoles and 3D inertial sensors, following which an intraindividual comparison was performed. Most spatiotemporal and kinematic parameters in the TAR group were indicative of good gait symmetry, while the AA group presented significant differences. Plantar pressure symmetry among the AA group was also significantly distorted. Abnormality in biomechanical behavior of the AA unoperated, contralateral foot was observed. In summary, our results indicate an altered BGM in AA patients, whereas a relatively fully recovered BGM is observed in TAR patients, despite the quantitative differences in several parameters when compared to a healthy population. Our study supports a biomechanical assessment and rehabilitation of both operated and unoperated sides after major surgeries for ankle osteoarthrosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background To examine the effect of anastomosis on experimental carcinogenesis in the colon of rats. Methods Forty-three 10-week-old male and female Sprague-Dawley rats were operated on by performing an end-to-side ileorectostomy. Group A:16 rats received no treatment. Group B: 27 rats received 18 subcutaneous injections weekly at a dose of 21 mg/kg wt of 1–2 dimethylhydrazine (DMH), from the eighth day after the intervention. Animals were sacrificed between 25–27 weeks. The number of tumours, their localization, size and microscopic characteristics were recorded. A paired chi-squared analysis was performed comparing tumoral induction in the perianastomotic zone with the rest of colon with faeces. Results No tumours appeared in the dimethylhydrazine-free group. The percentage tumoral area was greater in the perianastomotic zone compared to tumours which had developed in the rest of colon with faeces (p = 0.014). Conclusion We found a cocarcinogenic effect due to the creation of an anastomosis, when using an experimental model of colonic carcinogenesis induced by DMH in rats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In crop rotations that include alfalfa (Medicago sativa L.), agronomic and environmental concerns mean that it is important to determine the N fertilizer contribution of this legume for subsequent crops in order to help to increase the sustainability of cropping systems. To determine the N fertilizer replacement value (FRV) of a 2-yr alfalfa crop on subsequent crops of corn (Zea mays L.) followed by wheat (Triticum aestivum L.) under irrigated Mediterranean conditions, two 4-yr rotations (alfalfa-corn-wheat and corn-corn-corn-wheat) were conducted from 2001 to 2004 in a Typic Xerofluvent soil. Corn yields were compared after two years of alfalfa and a third year of corn under monoculture and wheat yields were also compared after both rotations. Corn production after alfalfa outyielded monoculture corn at all four rates of N fertilizer application analyzed (0, 100, 200 and 300 kg N/ha). The FRV of 2-yr alfalfa for corn was about 160 kg N/ha. Wheat grown after the alfalfa-corn rotation outyielded that grown after corn under monoculture at both the rates of N studied (0 and 100 kg N/ha). The FRV of alfalfa for wheat following alfalfa-corn was about 76 kg N/ha. Soil NO3 -N content after alfalfa was greater than with the corn monoculture at all rates of N fertilizer application and this higher value persisted during the second crop after alfalfa. This was probably one of the reasons for the better yields associated with the alfalfa rotation. These results make a valuable contribution to irrigated agriculture under mediterranean conditions, show reasons for interest in rotating alfalfa with corn, and explain how it is possible to make savings when applying N fertilizer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new dynamic model of dolomitization predicts a multitude of textural, paragenetic, geochemical and other properties of burial dolomites. The model is based on two postulates, (1) that the dolomitizing brine is Mg-rich but under saturated with both calcite and dolomite, and (2) that the dolomite-for-calcite replacement happens not by dissolution-precipitation as usually assumed, but by dolomite-growth-driven pressure solution of the calcite host. Crucially, the dolomite-for-calcite replacement turns out to be self-accelerating via Ca2 : the Ca2 released by each replacement increment accelerates the rate of the next, and so on. As a result, both pore-fluid Ca2 and replacement rate grow exponentially.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Management of degenerated aortic valve bioprosthesis classically requires redo surgery, but transcatheter aortic valve-in-valve implantation is becoming a valid alternative in selected cases. In the case of a degenerated Mitroflow bioprosthesis, TAVR is associated with an additional challenge due to a specific risk of coronary occlusion. We aimed to assess the safety and feasibility of transfemoral valve-in-valve implantation of the new Edwards Sapien 3 (Edwards Lifesciences) in a degenerated Mitroflow bioprosthesis (Sorin Group, Inc). METHODS: We report here the safety and feasibility of transfemoral valve-in-valve implantation of a 23 mm Edwards Sapien 3 in a degenerated 25 mm Mitroflow valve and describe the specific assessment of the risk of coronary obstruction using a multi-imaging modality. RESULTS: The final result showed an absence of aortic regurgitation and a mean transvalvular gradient of 14 mm Hg. The patient had no major adverse cardiovascular events at 30-day follow-up. CONCLUSION: Transcatheter valve-in-valve implantation of an Edwards Sapien 3 in a degenerated Mitroflow is feasible and safe, considering a careful assessment of the risk of coronary obstruction with Mitroflow bioprosthesis due to leaflets mounted externally to the stent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pd-catalysed reactions of 2-Cl, 2-Br and 2-I derivatives of a 6-chloropurine nucleoside with benzamide have been compared, using Pd2dba3, Xantphos and Cs2CO3 in toluene, between 20 and 80 °C. The reactivity order was 2-I > 2-Br > 6-Cl ≫ 2-Cl. The 2-I substituent could be replaced even at 0 °C, under conditions disclosed here for the first time. On the other hand, the replacement of the chlorine atom at position 2 (2-Cl) required 110 °C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During transapical transcatheter aortic valve replacement (TA-TAVR), the apical closure remains a challenge for the surgeon, having the risk for ventricular tear and massive bleeding. Apical closure devices are already under clinical evaluation, but only a few can lead to a full percutaneous TA-TAVR. We describe the successful use of a 9-mm myocardial occluder (ventricular septal defect occluder) that was used to seal the apex after a standard TA-TAVR (using the Sapien XT 23-mm transcatheter valve and the Ascendra + delivery system). The placement of the nonmodified myocardial occluder was performed through the Ascendra + delivery system, with a very small amount of blood loss and an acceptable sealing of the apical tear. This approach is feasible and represents a further step toward true-percutaneous transapical heart valve procedures. Modified apical occluders are under evaluation in animal models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

NlmCategory="UNASSIGNED">Rapid deployment aortic valve replacement (RDAVR) with the use of rapid deployment valve systems represents a smart alternative to the use of standard aortic bioprosthesis for aortic valve replacement. Nevertheless, its use is still debatable in patients with pure aortic valve regurgitation or true bicuspid aortic valve because of the risk of postoperative paravalvular leak. To address this issue, an optimal annulus-valve size match seems to be the ideal surgical strategy. This article describes a new technique developed to stabilize the aortic annulus and prevent paravalvular leak after RDAVR. To confirm the feasibility, this technique was performed in six patients with severe symptomatic aortic stenosis who were scheduled to undergo aortic valve replacement at our center. All patients survived surgery and were discharged from the hospital. There were no new intracardiac conduction system disturbances observed, and a permanent pacemaker implantation was not required in any of the patients. The intraoperative and postoperative echocardiogram confirmed successful positioning of the valve, and no paravalvular leak was observed. In this preliminary experience, RDAVR through a full sternotomy or an upper hemisternotomy approach with the use of aortic annulus stabilization technique was safe, and no leak was observed. Future studies on large series of patients are necessary to confirm the safety and effectiveness of this technique in preventing paravalvular leak in patients with true bicuspid aortic valves or pure aortic regurgitation.