992 resultados para cochlear implantation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To examine the efficacy and safety of repeat deep sclerectomy (DS) versus Baerveldt shunt (BS) implantation as second line surgery following failed primary DS. Methods: Fifty one patients were prospectively recruited to undergo BS implantation following failed DS and 51 patients underwent repeat DS, for which data was collected retrospectively. All eyes had at least one failed DS. Surgical success was defined as IOP≤21mmHg and 20% reduction in IOP from baseline. Success rates, number of glaucoma medications (GMs), IOP, and complication rates were compared between the two groups at year 1, post-operatively. Results: Mean age, sex and the proportion of glaucoma subtypes were similar between groups. Preoperatively IOP was significantly lower in DS group vs BS group (18.8mmHg vs 23.8mmHg, p<0.01, two sample t-test). Postoperatively IOP was significantly higher in DS group than BS group (14.6mmHg vs 12.0mmHg, p<0.01, two-sample t-test). In the DS group, 47% of eyes did not achieve 20% reduction in IOP from baseline, as a result the success rates were significantly lower in eyes with DS (51%) than in eyes with BS (88%) (p=0.02, log-rank test). Preoperatively the number of GMs used in DS and BS groups were similar (2.2 vs 2.7 p=0.02, two sample t-test). Postoperatively there remained no significant difference in GMs between groups (0.9 vs 1.1, p= 0.58, two sample t-test). Complication rates were similar between the two groups (12% vs 10%). Conclusions: Baerveldt tube implantation was more effective in lowering IOP than repeat deep sclerectomy in eyes with failed primary DS, at year one. Complications were minor and infrequent in both groups

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapport de synthèse : But: la resténose intra-stent au sirolimus (SAS) reste un problème clinique. Parmi tes diverses approches thérapeutiques disponibles aujourd'hui aucune n'a la primauté car tes résultats à moyen terme restent relativement médiocres. Méthodologie: les patients souffrant d'une resténose intra-SAS chez lesquels un second SAS a été implanté comme traitement de cette resténose ont été inclus dans ce registre. Lors d'ischémie clinique ou électrique après implantation d'un SAS les malades chez lesquels l'angioplastie au ballon seul ne donnait pas un résultat satisfaisant ont bénéficié de l'implantation d'un stent actif dans un stent actif. Résultats: vingt-sept patients sont inclus dans ce registre. La resténose était de type focale dans 34% des cas, diffuse dans 59% des cas et proliférative dans 7% des cas. La procédure a été un succès chez tous les patients sans complications aiguës durant l'hospitalisation. A 14±7 mois, on dénombre 8 (30%) événements cardiaques majeurs (1 mort, 1 infarctus du myocarde, 4 revascularisations additionnelles de la lésion, 1 revascularisation additionnelle du vaisseau cible). Un patient a subi un pontage aorto-coronarien. Dix-neuf patients (70%) ont évolué sans aucun problème. Conclusion: en conclusion, l'implantation d'un SAS pour traiter une resténose intra-SAS est réalisable avec un très bon résultat immédiat. Cependant, l'incidence d'un événement cardiaque majeur reste élevée à long terme.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dans le cadre de ce travail de thèse intitulé, nous avons étudié les impacts des nouvelles technologies de l?information et de la communication sur les administrations publiques. Notre objectif principal était de modéliser un guichet virtuel puis d?en implémenter un prototype. Nous avons donc dans un premier temps étudié une sélection de réalisations internationales et suisses dans le domaine, ainsi que des travaux de recherche visant à développer des modèles pour un état électronique. Nous avons ensuite travaillé sur la base des résultats d?une enquête de terrain menée au sein d?une administration cantonale et auprès de citoyens. Ces données de base nous ont permis de définir un modèle de guichet virtuel, qui couvre les aspects statiques et dynamiques d?un tel système. Enfin nous avons utilisé le modèle abstrait pour définir l?architecture théorique de notre prototype de guichet virtuel, avant d?effectuer certains choix technologiques et de l?implémenter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The optical and electrical recovery processes of the metastable state of the EL2 defect artificially created in n‐type GaAs by boron or oxygen implantation are analyzed at 80 K using optical isothermal transient spectroscopy. In both cases, we have found an inhibition of the electrical recovery and the existence of an optical recovery in the range 1.1-1.4 eV, competing with the photoquenching effect. The similar results obtained with both elements and the different behavior observed in comparison with the native EL2 defect has been related to the network damage produced by the implantation process. From the different behavior with the technological process, it can be deduced that the electrical and optical anomalies have a different origin. The electrical inhibition is due to the existence of an interaction between the EL2 defect and other implantation‐created defects. However, the optical recovery seems to be related to a change in the microscopic metastable state configuration involving the presence of vacancies

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although surgical aortic valve replacement has been the standard of care for patient with severe aortic stenosis, transcatheter aortic valve implantation (TAVI) is now a fair standard of care for patients not eligible or high risk for surgical treatment. The decision of therapeutic choice between TAVI and surgery considers surgical risk (estimated by the Euro-SCORE and STS-PROM) as well as many parameters that go beyond the assessment of the valvular disease's severity by echocardiography: a multidisciplinary assessment in "Heart Team" is needed to assess each case in all its complexity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Concomitant aortic and mitral valve replacement or concomitant aortic valve replacement and mitral repair can be a challenge for the cardiac surgeon: in particular, because of their structure and design, two bioprosthetic heart valves or an aortic valve prosthesis and a rigid mitral ring can interfere at the level of the mitroaortic junction. Therefore, when a mitral bioprosthesis or a rigid mitral ring is already in place and a surgical aortic valve replacement becomes necessary, or when older high-risk patients require concomitant mitral and aortic procedures, the new 'fast-implantable' aortic valve system (Intuity valve, Edwards Lifesciences, Irvine, CA, USA) can represent a smart alternative to standard aortic bioprosthesis. Unfortunately, this is still controversial (risk of interference). However, transcatheter aortic valve replacements have been performed in patients with previously implanted mitral valves or mitral rings. Interestingly, we learned that there is no interference (or not significant interference) among the standard valve and the stent valve. Consequently, we can assume that a fast-implantable valve can also be safely placed next to a biological mitral valve or next to a rigid mitral ring without risks of distortion, malpositioning, high gradient or paravalvular leak. This paper describes two cases: a concomitant Intuity aortic valve and bioprosthetic mitral valve implantation and a concomitant Intuity aortic valve and mitral ring implantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: New generation transcatheter heart valves (THV) may improve clinical outcomes of transcatheter aortic valve implantation. METHODS AND RESULTS: In a nationwide, prospective, multicenter cohort study (Swiss Transcatheter Aortic Valve Implantation Registry, NCT01368250), outcomes of consecutive transfemoral transcatheter aortic valve implantation patients treated with the Sapien 3 THV (S3) versus the Sapien XT THV (XT) were investigated. An overall of 153 consecutive S3 patients were compared with 445 consecutive XT patients. Postprocedural mean transprosthetic gradient (6.5±3.0 versus 7.8±6.3 mm Hg, P=0.17) did not differ between S3 and XT patients, respectively. The rate of more than mild paravalvular regurgitation (1.3% versus 5.3%, P=0.04) and of vascular (5.3% versus 16.9%, P<0.01) complications were significantly lower in S3 patients. A higher rate of new permanent pacemaker implantations was observed in patients receiving the S3 valve (17.0% versus 11.0%, P=0.01). There were no significant differences for disabling stroke (S3 1.3% versus XT 3.1%, P=0.29) and all-cause mortality (S3 3.3% versus XT 4.5%, P=0.27). CONCLUSIONS: The use of the new generation S3 balloon-expandable THV reduced the risk of more than mild paravalvular regurgitation and vascular complications but was associated with an increased permanent pacemaker rate compared with the XT. Transcatheter aortic valve implantation using the newest generation balloon-expandable THV is associated with a low risk of stroke and favorable clinical outcomes. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01368250.