971 resultados para Zero-coupon yield curve
Resumo:
The carousel wind tunnel (CWT) can be a significant tool for the determination of the nature and magnitude of interparticlar forces at threshold of motion. By altering particle and drum surface electrical properties and/or by applying electric potential difference across the inner and outer drums, it should be possible to separate electrostatic effects from other forces of cohesion. Besides particle trajectory and bedform analyses, suggestions for research include particle aggregation in zero and sub-gravity environments, effect of suspension-saltation ratio on soil abrasion, and the effects of shear and shear free turbulence on particle aggregation as applied to evolution of solar nebula.
Resumo:
The tetraalkylation of N-benzylphthalimide is the major yield limiting step in the common synthetic route to isoindoline nitroxides. The progress of this reaction was found to be limited by the formation of previously unobserved mono- and dialkyl side products that do not lead to the desired product. The yield for the tetraalkylation of N-benzylphthalimide with ethylmagnesium iodide could be increased (60% over 2 steps) when a step-wise addition sequence was employed. The new two step synthesis offers a practical preparative scale alternative to the current approach.
Resumo:
We perform an analytic and numerical study of an inviscid contracting bubble in a two-dimensional Hele-Shaw cell, where the effects of both surface tension and kinetic undercooling on the moving bubble boundary are not neglected. In contrast to expanding bubbles, in which both boundary effects regularise the ill-posedness arising from the viscous (Saffman-Taylor) instability, we show that in contracting bubbles the two boundary effects are in competition, with surface tension stabilising the boundary, and kinetic undercooling destabilising it. This competition leads to interesting bifurcation behaviour in the asymptotic shape of the bubble in the limit it approaches extinction. In this limit, the boundary may tend to become either circular, or approach a line or "slit" of zero thickness, depending on the initial condition and the value of a nondimensional surface tension parameter. We show that over a critical range of surface tension values, both these asymptotic shapes are stable. In this regime there exists a third, unstable branch of limiting self-similar bubble shapes, with an asymptotic aspect ratio (dependent on the surface tension) between zero and one. We support our asymptotic analysis with a numerical scheme that utilises the applicability of complex variable theory to Hele-Shaw flow.
Resumo:
In this study x-ray CT has been used to produce a 3D image of an irradiated PAGAT gel sample, with noise-reduction achieved using the ‘zero-scan’ method. The gel was repeatedly CT scanned and a linear fit to the varying Hounsfield unit of each pixel in the 3D volume was evaluated across the repeated scans, allowing a zero-scan extrapolation of the image to be obtained. To minimise heating of the CT scanner’s x-ray tube, this study used a large slice thickness (1 cm), to provide image slices across the irradiated region of the gel, and a relatively small number of CT scans (63), to extrapolate the zero-scan image. The resulting set of transverse images shows reduced noise compared to images from the initial CT scan of the gel, without being degraded by the additional radiation dose delivered to the gel during the repeated scanning. The full, 3D image of the gel has a low spatial resolution in the longitudinal direction, due to the selected scan parameters. Nonetheless, important features of the dose distribution are apparent in the 3D x-ray CT scan of the gel. The results of this study demonstrate that the zero-scan extrapolation method can be applied to the reconstruction of multiple x-ray CT slices, to provide useful 2D and 3D images of irradiated dosimetry gels.
Resumo:
Cisplatin and carboplatin are active in previously untreated patients with metastatic breast cancer (MBC) with mean response rates (RRs) of 50 and 32%, respectively. In pretreated patients the RR to cisplatin/carboplatin monotherapy declines markedly to <10%. Cisplatin and carboplatin have been combined with many other cytotoxics. In first-line setting high activity has been observed in combination with taxanes or vinorelbine (RRs consistently ∼60%). It appears that these newer combinations are superior to older regimens with etoposide (RRs 30 to 50%) or 5-fluorouracil (RRs 40 to 60%). Cisplatin-/carboplatin-based regimens with infusional 5-FU and epirubicin/paclitaxel/vinorelbine achieve high RRs of around 60 to 80%. However these regimens are difficult to administer in all patients because they require central venous access for continuous 5-FU infusion. In pretreated MBC the combinations of cisplatin-taxane/vinorelbine/gemcitabine or carboplatin-docetaxel/vinorelbine yield RRs of 40 to 50%, which are higher than those achieved with platinum-etoposide/5-FU. In locally advanced disease cisplatin-based regimens achieve very high RRs (>80%). This would suggest that in chemotherapy-naïve patients platinum-based therapy might have an important role to play. Additionally the synergy demonstrated between platinum compounds, taxanes and herceptin, in preclinical and clinical studies is of immense importance and the results of the two ongoing Breast Cancer International Research Group randomized phase III studies are eagerly awaited. These studies may help clarify the role of platinum compounds in the treatment of metastatic and possibly early breast cancer. © 2003 Elsevier Ltd. All rights reserved.
Resumo:
A novel composite material based on deposition of nanosized zero-valent iron (nZVI) particles on acid-leached diatomite was synthesised for the removal of a chlorinated contaminant in water. The nZVI /diatomite composites were characterized by X-ray diffraction, scanning electron microscopy, elemental analysis, transmission electron microscopy and X-ray photoelectron spectroscopy. Compared with the pure nZVI particles, better dispersion of nZVI particles on the surface or inside the pores of diatom shells was observed. The herbicide simazine was selected as the model chlorinated contaminant and the removal efficiency by nZVI /diatomite composite was compared with that of the pristine nZVI and commercial iron powder. It was found that the diatomite supported nZVI composite material prepared by centrifugation exhibits relatively better efficient activity in decomposition of simazine than commercial Fe, lab synthesized nZVI and composite material prepared via rotary evaporation, and the optimum experimental conditions were obtained based on a series of batch experiments. This study on immobilizing nZVI particles onto diatomite opens a new avenue for the practical application of nZVI and the diatomite-supported nanosized zero-valent iron composite materials have potential applications in environmental remediation.
Resumo:
The Australasian rail industry lacks a consistently accepted standard of minimal training necessary to perform rail incident investigations. Current Australasian courses do not offer the breadth of development required for a comprehensive career pathway in incident investigation (Biggs, Banks & Dovan, 2012; Short, Kains & Harris, 2010).
Resumo:
This study extends the ‘zero scan’ method for CT imaging of polymer gel dosimeters to include multi-slice acquisitions. Multi slice CT images consisting of 24 slices of 1.2 mm thickness were acquired of an irradiated polymer gel dosimeter, and processed with the zero scan technique. The results demonstrate that zero scan based gel readout can be successfully applied to generate a three dimensional image of the irradiated gel field. Compared to the raw CT images the processed figures and cross gel profiles demonstrated reduced noise and clear visibility of the penumbral region. Moreover these improved results further highlight the suitability of this method in volumetric reconstruction with reduced CT data acquisition per slice. This work shows that 3D volumes of irradiated polymer gel dosimeters can be acquired and processed with x-ray CT.
Resumo:
Background and aims: The assessment of intra-epidermal nerve fiber density (IENFD) in skin biopsies and corneal nerve fiber density (CNFD) using corneal confocal microscopy (CCM) provides promising techniques to detect small nerve fiber damage in patients with peripheral neuropathy. To help define the clinical utility of each of these techniques in patients with diabetic neuropathy we have assessed sensitivity and specificity of IENFD and CNFD in predicting the following: 1) diabetic polyneuropathy (DPN); 2) risk of foot ulceration (RFU); 3) initial small fiber neuropathy (iSFN); 4) severe small fiber neuropathy (sSFN)...
Resumo:
Nitrogen dioxide is used as a "radical scavenger" to probe the position of carbon-centered radicals within complex radical ions in the gas phase. As with analogous neutral radical reactions, this addition results in formation of an \[M + NO2](+) adduct, but the structural identity of this species remains ambiguous. Specifically, the question remains: do such adducts have a nitro-(RNO2) or nitrosoxy-(RONO) moiety, or are both isomers present in the adduct population? In order to elucidate the products of such reactions, we have prepared and isolated three distonic phenyl radical cations and observed their reactions with nitrogen dioxide in the gas phase by ion-trap mass spectrometry. In each case, stabilized \[M + NO2](+) adduct ions are observed and isolated. The structure of these adducts is probed by collision-induced dissociation and ultraviolet photodissociation action spectroscopy and a comparison made to the analogous spectra of authentic nitro-and nitrosoxy-benzenes. We demonstrate unequivocally that for the phenyl radical cations studied here, all stabilized \[M + NO2](+) adducts are exclusively nitrobenzenes. Electronic structure calculations support these mass spectrometric observations and suggest that, under low-pressure conditions, the nitrosoxy-isomer is unlikely to be isolated from the reaction of an alkyl or aryl radical with NO2. The combined experimental and theoretical results lead to the prediction that stabilization of the nitrosoxy-isomer will only be possible for systems wherein the energy required for dissociation of the RO-NO bond (or other low energy fragmentation channels) rises close to, or above, the energy of the separated reactants.
Resumo:
The dynamics describing the motion response of a marine structure in waves can be represented within a linear framework by the Cummins Equation. This equation contains a convolution term that represents the component of the radiation forces associated with fluid memory effects. Several methods have been proposed in the literature for the identification of parametric models to approximate and replace this convolution term. This replacement can facilitate the model implementation in simulators and the analysis of motion control designs. Some of the reported identification methods consider the problem in the time domain while other methods consider the problem in the frequency domain. This paper compares the application of these identification methods. The comparison is based not only on the quality of the estimated models, but also on the ease of implementation, ease of use, and the flexibility of the identification method to incorporate prior information related to the model being identified. To illustrate the main points arising from the comparison, a particular example based on the coupled vertical motion of a modern containership vessel is presented.
Resumo:
Novel nano zero-valent iron/palygorskite composite materials prepared by evaporative and centrifuge methods are tested for the degradation of bisphenol A in an aqueous medium. A systematic study is presented which showed that nano zero-valent iron material has little effect on bisphenol A degradation. When hydrogen peroxide was added to initiate the reaction, some percentage of bisphenol A removal (∼20%) was achieved; however, with the aid of air bubbles, the percentage removal can be significantly increased to ∼99%. Compared with pristine nano zero-valent iron and commercial iron powder, nano zero-valent iron/palygorskite composite materials have much higher reactivity towards bisphenol A and these materials are superior as they have little impact on the solution pH. However, for pristine nano zero-valent iron, it is difficult to maintain the reaction system at a favourable low pH which is a key factor in maintaining high bisphenol A removal. All materials were characterized by X-ray diffraction, scanning electron microscopy, elemental analysis, transmission electron microscopy and X-ray photoelectron spectroscopy. The optimum conditions were obtained based on a series of batch experiments. This study has extended the application of nano zero-valent iron/palygorskite composites as effective materials for the removal of phenolic compounds from the environment.
Resumo:
Established Monte Carlo user codes BEAMnrc and DOSXYZnrc permit the accurate and straightforward simulation of radiotherapy experiments and treatments delivered from multiple beam angles. However, when an electronic portal imaging detector (EPID) is included in these simulations, treatment delivery from non-zero beam angles becomes problematic. This study introduces CTCombine, a purpose-built code for rotating selected CT data volumes, converting CT numbers to mass densities, combining the results with model EPIDs and writing output in a form which can easily be read and used by the dose calculation code DOSXYZnrc...
Resumo:
The purpose of this study was to derive ActiGraph cut-points for sedentary (SED), light-intensity physical activity (LPA), and moderate-to-vigorous physical activity (MVPA) in toddlers and evaluate their validity in an independent sample. The predictive validity of established preschool cut-points were also evaluated and compared. Twenty-two toddlers (mean age = 2.1 years ± 0.4 years) wore an ActiGraph accelerometer during a videotaped 20-min play period. Videos were subsequently coded for physical activity (PA) intensity using the modified Children's Activity Rating Scale (CARS). Receiver operating characteristic (ROC) curve analyses were conducted to determine cut-points. Predictive validity was assessed in an independent sample of 18 toddlers (mean age = 2.3 ± 0.4 years). From the ROC curve analyses, the 15-s count ranges corresponding to SED, LPA, and MVPA were 0–48, 49–418, and >418 counts/15 s, respectively. Classification accuracy was fair for the SED threshold (ROC-AUC = 0.74, 95% confidence interval = 0.71–0.76) and excellent for MVPA threshold (ROC-AUC = 0.90, 95% confidence interval = 0.88–0.92). In the cross-validation sample, the toddler cut-point and established preschool cut-points significantly overestimated time spent in SED and underestimated time in spent in LPA. For MVPA, mean differences between observed and predicted values for the toddler and Pate cut-points were not significantly different from zero. In summary, the ActiGraph accelerometer can provide useful group-level estimates of MVPA in toddlers. The results support the use of the Pate cut-point of 420 counts/15 s for MVPA.