956 resultados para Variability of mechanical and convective mixing


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND. Total knee (TKR) and hip (THR) replacement (arthroplasty) are effective surgical procedures that relieve pain, improve patients' quality of life and increase functional capacity. Studies on variations in medical practice usually place the indications for performing these procedures to be highly variable, because surgeons appear to follow different criteria when recommending surgery in patients with different severity levels. We therefore proposed a study to evaluate inter-hospital variability in arthroplasty indication. METHODS. The pre-surgical condition of 1603 patients included was compared by their personal characteristics, clinical situation and self-perceived health status. Patients were asked to complete two health-related quality of life questionnaires: the generic SF-12 (Short Form) and the specific WOMAC (Western Ontario and Mcmaster Universities) scale. The type of patient undergoing primary arthroplasty was similar in the 15 different hospitals evaluated.The variability in baseline WOMAC score between hospitals in THR and TKR indication was described by range, mean and standard deviation (SD), mean and standard deviation weighted by the number of procedures at each hospital, high/low ratio or extremal quotient (EQ5-95), variation coefficient (CV5-95) and weighted variation coefficient (WCV5-95) for 5-95 percentile range. The variability in subjective and objective signs was evaluated using median, range and WCV5-95. The appropriateness of the procedures performed was calculated using a specific threshold proposed by Quintana et al for assessing pain and functional capacity. RESULTS. The variability expressed as WCV5-95 was very low, between 0.05 and 0.11 for all three dimensions on WOMAC scale for both types of procedure in all participating hospitals. The variability in the physical and mental SF-12 components was very low for both types of procedure (0.08 and 0.07 for hip and 0.03 and 0.07 for knee surgery patients). However, a moderate-high variability was detected in subjective-objective signs. Among all the surgeries performed, approximately a quarter of them could be considered to be inappropriate. CONCLUSIONS. A greater inter-hospital variability was observed for objective than for subjective signs for both procedures, suggesting that the differences in clinical criteria followed by surgeons when indicating arthroplasty are the main responsible factors for the variation in surgery rates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Infection with some genotypes of human papillomavirus (HPV) is the most important risk factor associated with cervical cancer (CC). Throughout the world, HPV type 58 prevalence varies from one region to another; it is higher in women from certain countries in Asia and Latin America, such as China and Mexico. Although intratypic variants have been reported on a few occasions, our knowledge about HPV 58 genetic variation remains limited. Therefore, this work aims to (i) determine the prevalence of HPV type 58 amongst Mexican women with invasive CC or precursor lesions and (ii) identify HPV 58 sequence variants. One hundred and forty five colposcopy clinic patients were studied. Genotyping of HPV 16, 18 and 58 was determined by specific nested PCR and HPV 58 variants were detected by direct sequencing. The general prevalence of HPV was 51.7% (75/145). HPV 16 was found in 30.6% (23/75) and HPV 58 in 24% (18/75) of the patients. HPV 18 was not identified in patients with cervical intraepithelial neoplasia (CIN) grade I; it was only found in those with CIN II, with a prevalence of 6.8% (3/44). In patients with CC, the prevalence of HPV 16 and 58 was 78.9%. Regarding HPV 58 variants, 94.4% of the HPV 58 sequences were identical to the prototype strain, whereas one sample showed changes at a single nucleotide. This study demonstrates a high prevalence of HPV 58 and a low genetic variability of E6 sequences amongst Mexican colposcopy patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recently, morphometric measurements of the ascending aorta have been done with ECG-gated multidector computerized tomography (MDCT) to help the development of future novel transcatheter therapies (TCT); nevertheless, the variability of such measurements remains unknown. Thirty patients referred for ECG-gated CT thoracic angiography were evaluated. Continuous reformations of the ascending aorta, perpendicular to the centerline, were obtained automatically with a commercially available computer aided diagnosis (CAD). Then measurements of the maximal diameter were done with the CAD and manually by two observers (separately). Measurements were repeated one month later. The Bland-Altman method, Spearman coefficients, and a Wilcoxon signed-rank test were used to evaluate the variability, the correlation, and the differences between observers. The interobserver variability for maximal diameter between the two observers was up to 1.2 mm with limits of agreement [-1.5, +0.9] mm; whereas the intraobserver limits were [-1.2, +1.0] mm for the first observer and [-0.8, +0.8] mm for the second observer. The intraobserver CAD variability was 0.8 mm. The correlation was good between observers and the CAD (0.980-0.986); however, significant differences do exist (P<0.001). The maximum variability observed was 1.2 mm and should be considered in reports of measurements of the ascending aorta. The CAD is as reproducible as an experienced reader.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. This study was conducted to determine whether newer infrared or laser welding technologies created joints superior to traditional furnace or torch soldering methods of joining metals. It was designed to assess the mechanical resistance, the characteristics of the fractured surfaces, and the elemental diffusion of joints obtained by four different techniques: (1) preceramic soldering with a propane-oxygen torch, (2) postceramic soldering with a porcelain furnace, (3) preceramic and (4) postceramic soldering with an infrared heat source, and (5) laser welding. Material and methods. Mechanical resistance was determined by measuring the ultimate tensile strength of the joint and by determining their resistance to fatigue loading. Elemental diffusion to and from the joint was assessed with microprobe tracings. Scanning electron microscopy micrographs of the fractured surface were also obtained and evaluated. Results. Under monotonic tensile stress, three groups emerged: The laser welds were the strongest, the preceramic joints ranged second, and the postceramic joints were the weakest. Under fatigue stress, the order was as follows: first, the preceramic joints, and second, a group that comprised both postceramic joints and the laser welds. Inspection of the fractographs revealed several fracture modes but no consistent pattern emerged. Microprobe analyses demonstrated minor diffusion processes in the preceramic joints, whereas significant diffusion was observed in the postceramic joints. Clinical Implications. The mechanical resistance data conflicted as to the strength that could be expected of laser welded joints. On the basis of fatigue resistance of the joints, neither infrared solder joints nor laser welds were stronger than torch or furnace soldered joints.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: to assess the between and within-device reproducibility, as well as within-day variability of body fat measurements. Methods: body fat percentage (%BF) was measured twice on seventeen female students aged between 18 and 20 with a body mass index of 21.9 22.6 kg/m2 (mean SD) using seven bipolar bioelectrical impedance devices (BF-306) according to the manufacturer's recommendations. Each student was also measured each hour between 7:00 and 22:00. Statistical analysis was conducted using a general linear model for repeated measurements. Results: the correlation between first and second measurements was very high (Pearson r between 0.985 and 1.000, p<0.001), as well as the correlation between devices (Pearson r between 0.986 and 0.999, all p<0.001). Repeated measurements analysis showed no differences were between devices (F test=0.83, p=0.59) or readings (first vs. second: F test=0.12, p=0.74). Conversely, significant differences were found between assessment periods throughout the day, measurements made in the morning being lower than those made in the afternoon. Assuming an overall daily average of 100 (based on all measurements), the values were 95.8 3.2 (mean SD) at 8:00 versus 101.3 3.0 at 20:00, corresponding to a mean change of 2.2 1.1 in %BF (F test for repeated values=6.58, p<0.001). Conclusions: the between and within-device reproducibility for measuring body fat is high, enabling the use of multiple devices in a single study. Conversely, small but significant changes in body fat measurements occur during the day, urging body fat measurements to be performed at fixed times.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Understanding the true prevalence of lymphangioleiomyomatosis (LAM) is important in estimating disease burden and targeting specific interventions. As with all rare diseases, obtaining reliable epidemiological data is difficult and requires innovative approaches.Aim: To determine the prevalence and incidence of LAM using data from patient organizations in seven countries, and to use the extent to which the prevalence of LAM varies regionally and nationally to determine whether prevalence estimates are related to health-care provision.Methods: Numbers of women with LAM were obtained from patient groups and national databases from seven countries (n = 1001). Prevalence was calculated for regions within countries using female population figures from census data. Incidence estimates were calculated for the USA, UK and Switzerland. Regional variation in prevalence and changes in incidence over time were analysed using Poisson regression and linear regression.Results: Prevalence of LAM in the seven countries ranged from 3.4 to 7.8/million women with significant variation, both between countries and between states in the USA. This variation did not relate to the number of pulmonary specialists in the region nor the percentage of population with health insurance, but suggests a large number of patients remain undiagnosed. The incidence of LAM from 2004 to 2008 ranged from 0.23 to 0.31/million women/per year in the USA, UK and Switzerland.Conclusions: Using this method, we have found that the prevalence of LAM is higher than that previously recorded and that many patients with LAM are undiagnosed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Human respiratory syncytial virus (HRSV) is an important respiratory pathogens among children between zero-five years old. Host immunity and viral genetic variability are important factors that can make vaccine production difficult. In this work, differences between biological clones of HRSV were detected in clinical samples in the absence and presence of serum collected from children in the convalescent phase of the illness and from their biological mothers. Viral clones were selected by plaque assay in the absence and presence of serum and nucleotide sequences of the G2 and F2 genes of HRSV biological clones were compared. One non-synonymous mutation was found in the F gene (Ile5Asn) in one clone of an HRSV-B sample and one non-synonymous mutation was found in the G gene (Ser291Pro) in four clones of the same HRSV-B sample. Only one of these clones was obtained after treatment with the child's serum. In addition, some synonymous mutations were determined in two clones of the HRSV-A samples. In conclusion, it is possible that minor sequences could be selected by host antibodies contributing to the HRSV evolutionary process, hampering the development of an effective vaccine, since we verify the same codon alteration in absence and presence of human sera in individual clones of BR-85 sample.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives The site of pharmacological activity of raltegravir is intracellular. Our aim was to determine the extent of raltegravir cellular penetration and whether raltegravir total plasma concentration (C(tot)) predicts cellular concentration (C(cell)). Methods Open-label, prospective, pharmacokinetic study on HIV-infected patients on a stable raltegravir-containing regimen. Plasma and peripheral blood mononuclear cells were simultaneously collected during a 12 h dosing interval after drug intake. C(tot) and C(cell) of raltegravir, darunavir, etravirine, maraviroc and ritonavir were measured by liquid chromatography coupled to tandem mass spectrometry after protein precipitation. Longitudinal mixed effects analysis was applied to the C(cell)/C(tot) ratio. Results Ten HIV-infected patients were included. The geometric mean (GM) raltegravir total plasma maximum concentration (C(max)), minimum concentration (C(min)) and area under the time-concentration curve from 0-12 h (AUC(0-12)) were 1068 ng/mL, 51.1 ng/mL and 4171 ng·h/mL, respectively. GM raltegravir cellular C(max), C(min) and AUC(0-12) were 27.5 ng/mL, 2.9 ng/mL and 165 ng·h/mL, respectively. Raltegravir C(cell) corresponded to 5.3% of C(tot) measured simultaneously. Both concentrations fluctuate in parallel, with C(cell)/C(tot) ratios remaining fairly constant for each patient without a significant time-related trend over the dosing interval. The AUC(cell)/AUC(tot) GM ratios for raltegravir, darunavir and etravirine were 0.039, 0.14 and 1.55, respectively. Conclusions Raltegravir C(cell) correlated with C(tot) (r = 0.86). Raltegravir penetration into cells is low overall (∼5% of plasma levels), with distinct raltegravir cellular penetration varying by as much as 15-fold between patients. The importance of this finding in the context of development of resistance to integrase inhibitors needs to be further investigated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: We sought to investigate the relationship between infarct and dyssynchrony post- myocardial infarct (MI), in a porcine model. Mechanical dyssynchrony post-MI is associated with left ventricular (LV) remodeling and increased mortality. METHODS: Cine, gadolinium-contrast, and tagged cardiovascular magnetic resonance (CMR) were performed pre-MI, 9 ± 2 days (early post-MI), and 33 ± 10 days (late post-MI) post-MI in 6 pigs to characterize cardiac morphology, location and extent of MI, and regional mechanics. LV mechanics were assessed by circumferential strain (eC). Electro-anatomic mapping (EAM) was performed within 24 hrs of CMR and prior to sacrifice. RESULTS: Mean infarct size was 21 ± 4% of LV volume with evidence of post-MI remodeling. Global eC significantly decreased post MI (-27 ± 1.6% vs. -18 ± 2.5% (early) and -17 ± 2.7% (late), p < 0.0001) with no significant change in peri-MI and MI segments between early and late time-points. Time to peak strain (TTP) was significantly longer in MI, compared to normal and peri-MI segments, both early (440 ± 40 ms vs. 329 ± 40 ms and 332 ± 36 ms, respectively; p = 0.0002) and late post-MI (442 ± 63 ms vs. 321 ± 40 ms and 355 ± 61 ms, respectively; p = 0.012). The standard deviation of TTP in 16 segments (SD16) significantly increased post-MI: 28 ± 7 ms to 50 ± 10 ms (early, p = 0.012) to 54 ± 19 ms (late, p = 0.004), with no change between early and late post-MI time-points (p = 0.56). TTP was not related to reduction of segmental contractility. EAM revealed late electrical activation and greatly diminished conduction velocity in the infarct (5.7 ± 2.4 cm/s), when compared to peri-infarct (18.7 ± 10.3 cm/s) and remote myocardium (39 ± 20.5 cm/s). CONCLUSIONS: Mechanical dyssynchrony occurs early after MI and is the result of delayed electrical and mechanical activation in the infarct.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The white Barn Owl subspecies (Tyto alba alba) is found in southern Europe and the reddish-brown subspecies (T a. guttata) in northern and eastern Europe. In central Europe, the two subspecies interbreed producing a large range of phenotypic variants. Because of the different ratios of the subspecies in different geographic regions, we predict that genetic variation should be greater in Switzerland than in Hungary. We tested this hypothesis by measuring genetic variation with the RAPD method. As predicted, the genetic differentiation within a Swiss population of Barn Owls was significantly greater than the variation within a Hungarian population. This suggests that gene flow is greater in central Europe than at the eastern limit of the Barn Owl distribution in Hungary. In both countries genetic variation was more pronounced in females than in males. As in other birds, this is probably because female Barn Owls are less philopatric than males. The number of migrants between Hungary and Switzerland is ca. 1 individual per generation; if calculated separately for the sexes, then 0.525 for males and ca. I for females (Nm values). The difference in the number of migrants between genders again is likely a consequence of higher male philopatry. The sexual differentiation is greater in the Swiss population than in the Hungarian and the genetic substructuring of the populations of the species is substantial. The reason for the considerable population substructuring could be the nonmigratory behavior and socially monogamous pairing of the species, as well as the geographical barriers (Alps) between the populations examined.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A dynamic, three-commodity rational-expectations storage model is used to compare the impact of the Federal Agricultural Improvement and Reform (FAIR) Act of 1996 with a freemarket policy and with the agricultural policies that preceded the FAIR Act. Results support the hypothesis that the changes made when FAIR was enacted did not lead to permanent significant increases in the volatility of farm prices or revenues. An important finding is that the main economic impacts of the Pre-FAIR scenario, relative to the free-market regime were to transfer income to farmers and to substitute government storage for private storage in a way that did little to support prices or to stabilize farm incomes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Voriconazole (VRC) is a broad-spectrum antifungal triazole with nonlinear pharmacokinetics. The utility of measurement of voriconazole blood levels for optimizing therapy is a matter of debate. Available high-performance liquid chromatography (HPLC) and bioassay methods are technically complex, time-consuming, or have a narrow analytical range. Objectives of the present study were to develop new, simple analytical methods and to assess variability of voriconazole blood levels in patients with invasive mycoses. Acetonitrile precipitation, reverse-phase separation, and UV detection were used for HPLC. A voriconazole-hypersusceptible Candida albicans mutant lacking multidrug efflux transporters (cdr1Delta/cdr1Delta, cdr2Delta/cdr2Delta, flu1Delta/flu1Delta, and mdr1Delta/mdr1Delta) and calcineurin subunit A (cnaDelta/cnaDelta) was used for bioassay. Mean intra-/interrun accuracies over the VRC concentration range from 0.25 to 16 mg/liter were 93.7% +/- 5.0%/96.5% +/- 2.4% (HPLC) and 94.9% +/- 6.1%/94.7% +/- 3.3% (bioassay). Mean intra-/interrun coefficients of variation were 5.2% +/- 1.5%/5.4% +/- 0.9% and 6.5% +/- 2.5%/4.0% +/- 1.6% for HPLC and bioassay, respectively. The coefficient of concordance between HPLC and bioassay was 0.96. Sequential measurements in 10 patients with invasive mycoses showed important inter- and intraindividual variations of estimated voriconazole area under the concentration-time curve (AUC): median, 43.9 mg x h/liter (range, 12.9 to 71.1) on the first and 27.4 mg x h/liter (range, 2.9 to 93.1) on the last day of therapy. During therapy, AUC decreased in five patients, increased in three, and remained unchanged in two. A toxic encephalopathy probably related to the increase of the VRC AUC (from 71.1 to 93.1 mg x h/liter) was observed. The VRC AUC decreased (from 12.9 to 2.9 mg x h/liter) in a patient with persistent signs of invasive aspergillosis. These preliminary observations suggest that voriconazole over- or underexposure resulting from variability of blood levels might have clinical implications. Simple HPLC and bioassay methods offer new tools for monitoring voriconazole therapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To assess the inter/intraobserver variability of apparent diffusion coefficient (ADC) measurements in treated hepatic lesions and to compare ADC measurements in the whole lesion and in the area with the most restricted diffusion (MRDA). MATERIALS AND METHODS: Twenty-five patients with treated malignant liver lesions were examined on a 3.0T machine. After agreeing on the best ADC image, two readers independently measured the ADC values in the whole lesion and in the MRDA. These measurements were repeated 1 month later. The Bland-Altman method, Spearman correlation coefficients, and the Wilcoxon signed-rank test were used to evaluate the measurements. RESULTS: Interobserver variability for ADC measurements in the whole lesion and in the MRDA was 0.17 x 10(-3) mm(2)/s [-0.17, +0.17] and 0.43 x 10(-3) mm(2)/s [-0.45, +0.41], respectively. Intraobserver limits of agreement could be as low as [-0.10, +0.12] 10(-3) mm(2)/s and [-0.20, +0.33] 10(-3) mm(2)/s for measurements in the whole lesion and in the MRDA, respectively. CONCLUSION: A limited variability in ADC measurements does exist, and it should be considered when interpreting ADC values of hepatic malignancies. This is especially true for the measurements of the minimal ADC.