699 resultados para Transducer linearizer
Resumo:
The supra-molecular self-assembly of peptides and proteins is a process which underlies a range of normal and aberrant biological pathways in nature, but one which remains challenging to monitor in a quantitative way. We discuss the experimental details of an approach to this problem which involves the direct measurement in vitro of mass changes of the aggregates as new molecules attach to them. The required mass sensitivity can be achieved by the use of a quartz crystal transducer-based microbalance. The technique should be broadly applicable to the study of protein aggregation, as well as to the identification and characterisation of inhibitors and modulators of this process.
Resumo:
JP-10 (exo-tetrahydrodicyclopentadiene, C10H16) ignition delay times were measured in a preheated shock tube. The vapor pressures of the JP-10 were measured directly by using a high-precision vacuum gauge, to remedy the difficulty in determining the gaseous concentrations of heavy hydrocarbon fuel arising from the adsorption on the wall in shock tube experiments. The whole variation of pressure and emission of the OH or CH radicals were observed in the ignition process by a pressure transducer and a photomultiplier with a monochromator. The emission of the OH or CH radicals was used to identify the time to ignition. Experiments were performed over the pressure range of 151-556 kPa, temperature range of 1000-2100 K, fuel concentrations of 0.1%-0.55% mole fraction, and stoichiometric ratios of 0.25, 0.5, 1.0 and 2.0. The experimental results show that for the lower and higher temperature ranges, there are different dependency relationships of the ignition time on the temperature and the concentrations of JP-10 and oxygen.
Resumo:
6 p. Paper of the 17th Conference on Sensors and Their Applications held in Dubrovnik, Croatia. Sep 16-18, 2013
Resumo:
Investigations on the avoidance reactions of pelagic schooling fish (herring and sprat) released by an approaching fishery vessel were carried out during the 378th cruise of FRC "Solea" from 25 September to 3 October 1995 in the Arkona Sea, southern Baltic. An echosounder system EK 500/BI500 with a 38 kHz transducer mounted on a towed body as weIl as a 120 kHz hull mounted transducer were used. Fish densities were measured synchronously as well as under the ship as at a laterally distances from the ship by the transducer of the towed body. By these means the variation of fish densities up to a certain distance from the ship is possible. The advantage of using an echo integrating system for these measurements is, that it works also for not schooling fish and under conditions where schooling fish disperse (e.g. at night).
Resumo:
通过在线形谐振腔中引入一段缠绕在压电陶瓷上的单模光纤作为正弦相位调制器,使得激射波长的损耗不固定,抑制由于掺铒光纤的均匀展宽效应引起的模式竞争,从而避免了在室温下不稳定的单波长激射,实现了多波长掺铒光纤激光器的稳定输出。为了获得平坦的多波长输出,在谐振腔里使用了一个损耗峰位于1530nm处的长周期光纤光栅,以获得较为平坦的增益谱。通过两个3dB耦合器制成的反射型梳状滤波器的滤波作用,实验中观察到稳定的多波长激射,相邻波长间隔约为0.45nm。中心9个波长的输出功率平坦度为10dB,边模抑制比大于25dB。
Resumo:
The major objective of the study has been to investigate in detail the rapidly-varying peak uplift pressure and the slowly-varying positive and negative uplift pressures that are known to be exerted by waves against the underside of a horizontal pier or platform located above the still water level, but not higher than the crests of the incident waves.
In a "two-dimensional" laboratory study conducted in a 100-ft long by 15-in.-wide by 2-ft-deep wave tank with a horizontal smooth bottom, individually generated solitary waves struck a rigid, fixed, horizontal platform extending the width of the tank. Pressure transducers were mounted flush with the smooth soffit, or underside, of the platform. The location of the transducers could be varied.
The problem of a d equate dynamic and spatial response of the transducers was investigated in detail. It was found that unless the radius of the sensitive area of a pressure transducer is smaller than about one-third of the characteristic width of the pressure distribution, the peak pressure and the rise-time will not be recorded accurately. A procedure was devised to correct peak pressures and rise-times for this transducer defect.
The hydrodynamics of the flow beneath the platform are described qualitatively by a si1nple analysis, which relates peak pressure and positive slowly-varying pressure to the celerity of the wave front propagating beneath the platform, and relates negative slowly-varying pressure to the process by which fluid recedes from the platform after the wave has passed. As the wave front propagates beneath the platform, its celerity increases to a maximum, then decreases. The peak pressure similarly increases with distance from the seaward edge of the platform, then decreases.
Measured peak pressure head, always found to be less than five times the incident wave height above still water level, is an order of magnitude less than reported shock pressures due to waves breaking against vertical walls; the product of peak pressure and rise-time, considered as peak impulse, is of the order of 20% of reported shock impulse due to waves breaking against vertical walls. The maximum measured slowly-varying uplift pressure head is approximately equal to the incident wave height less the soffit clearance above still water level. The normalized magnitude and duration of negative pressure appears to depend principally on the ratio of soffit clearance to still water depth and on the ratio of platform length to still water depth.
Resumo:
This thesis has two basic themes: the investigation of new experiments which can be used to test relativistic gravity, and the investigation of new technologies and new experimental techniques which can be applied to make gravitational wave astronomy a reality.
Advancing technology will soon make possible a new class of gravitation experiments: pure laboratory experiments with laboratory sources of non-Newtonian gravity and laboratory detectors. The key advance in techno1ogy is the development of resonant sensing systems with very low levels of dissipation. Chapter 1 considers three such systems (torque balances, dielectric monocrystals, and superconducting microwave resonators), and it proposes eight laboratory experiments which use these systems as detectors. For each experiment it describes the dominant sources of noise and the technology required.
The coupled electro-mechanical system consisting of a microwave cavity and its walls can serve as a gravitational radiation detector. A gravitational wave interacts with the walls, and the resulting motion induces transitions from a highly excited cavity mode to a nearly unexcited mode. Chapter 2 describes briefly a formalism for analyzing such a detector, and it proposes a particular design.
The monitoring of a quantum mechanical harmonic oscillator on which a classical force acts is important in a variety of high-precision experiments, such as the attempt to detect gravitational radiation. Chapter 3 reviews the standard techniques for monitoring the oscillator; and it introduces a new technique which, in principle, can determine the details of the force with arbitrary accuracy, despite the quantum properties of the oscillator.
The standard method for monitoring the oscillator is the "amplitude- and-phase" method (position or momentum transducer with output fed through a linear amplifier). The accuracy obtainable by this method is limited by the uncertainty principle. To do better requires a measurement of the type which Braginsky has called "quantum nondemolition." A well-known quantum nondemolition technique is "quantum counting," which can detect an arbitrarily weak force, but which cannot provide good accuracy in determining its precise time-dependence. Chapter 3 considers extensively a new type of quantum nondemolition measurement - a "back-action-evading" measurement of the real part X1 (or the imaginary part X2) of the oscillator's complex amplitude. In principle X1 can be measured arbitrarily quickly and arbitrarily accurately, and a sequence of such measurements can lead to an arbitrarily accurate monitoring of the classical force.
Chapter 3 describes explicit gedanken experiments which demonstrate that X1 can be measured arbitrarily quickly and arbitrarily accurately, it considers approximate back-action-evading measurements, and it develops a theory of quantum nondemolition measurement for arbitrary quantum mechanical systems.
In Rosen's "bimetric" theory of gravity the (local) speed of gravitational radiation vg is determined by the combined effects of cosmological boundary values and nearby concentrations of matter. It is possible for vg to be less than the speed of light. Chapter 4 shows that emission of gravitational radiation prevents particles of nonzero rest mass from exceeding the speed of gravitational radiation. Observations of relativistic particles place limits on vg and the cosmological boundary values today, and observations of synchrotron radiation from compact radio sources place limits on the cosmological boundary values in the past.
Resumo:
报道了利用声光振幅调制锁模的方法,在激光二极管端面抽运Nd:YVO4激光器上获得320MHz高重复频率脉冲列的实验结果。实验采用平一平腔结构,腔长452mm,耦合输出镜透过率为3.6%。所用声光介质为熔融石英晶体,以铌酸锂作换能器,在驱动功率4.5W时,对1064nm波长衍射效率为50,相应的调制深度为0.31。在最佳锁模状态下,激光二极管抽运功率为3.5W,此时激光平均输出功率为15mw。示波器记录脉冲宽度680ps,实测光束质量因子M^2小于1.5。并在实验基础上对激光器工作的稳定性进行了分析,结果表
Resumo:
In many micro- and nano-scale technological applications high sensitivity displacement sensors are needed, especially in ultraprecision metrology and manufacturing. In this work a new way of sensing displacement based on radio frequency resonant cavities is presented and experimentally demonstrated using a first laboratory prototype. The principle of operation of the new transducer is summarized and tested. Furthermore, an electronic interface that can be used together with the displacement transducer is designed and proved. It has been experimentally demonstrated that very high and linear sensitivity characteristic curves, in the range of some kHz/nm; are easily obtainable using this kind of transducer when it is combined with a laboratory network analyzer. In order to replace a network analyzer and provide a more affordable, self-contained, compact solution, an electronic interface has been designed, preserving as much as possible the excellent performance of the transducer, and turning it into a true standalone positioning sensor. The results obtained using the transducer together with a first prototype of the electronic interface built with cheap discrete elements show that positioning accuracies in the micrometer range are obtainable using this cost-effective solution. Better accuracies would also be attainable but using more involved and costly electronics interfaces.
Resumo:
在Mie散射理论基础上,由单分散射的光强表达式导出在偏振光的入射条件下一定立体角内的散射光通量的表达式,并与自然光入射作比较。计算了在相同强度不同光源入射下,尘埃粒子计数器的两种常用散射光收集系统收集的散射光通量。结果表明:采用近前向散射光收集系统得到的光通量相等;而采用直角方向散射光收集系统时两者并不相等,且在平面偏振光入射时,收集的散射光通量还跟探测器中心与入射光偏振方向夹角有关。用MATLAB编程计算,得出了在探测器中心与偏振方向的夹角成90°或270°位置时,收集的散射光通量有极值的结论,为激光尘
Resumo:
Nesta pesquisa utilizou-se um equipamento experimental que utiliza o método do eco-impacto produzido no Laboratório de Ensaios Físicos do Instituto Politécnico do Rio de Janeiro (UERJ/IPRJ), para estimar a espessuras de placas de concreto através da propagação de ondas de tensão geradas por um impacto. Para determinação dessa espessura, foram investigados vários mecanismos de estruturação do protótipo do equipamento com objetivo de se obter a melhor leitura possível, por meio das literaturas existentes. Entre parâmetros avaliados no estudo, estava o modelo de sensor a ser utilizado, o tipo de impactor, a precisão relacionada à aquisição de dados e o tratamento do mesmo, a distância entre o ponto de impacto e o transdutor (sensor), e o local de teste. Os resultados experimentais concordam com as previsões teóricas e revelam que este método é eficiente para análise de estrutura de concreto. A análise da espessura e resposta em frequência de um novo protótipo desenvolvido e os testes realizados possibilitou um erro médio de espessura real para amostras sem agregados de 0,39% e para as amostras com agregados com de 0,64%. Esses resultados apontam que o equipamento produzido tem potencial e que o mesmo pode ser utilizado para avaliação de estrutura de concreto.
Resumo:
Here we demonstrate that a free-standing carbon nanotube (CNT) array can be used as a large surface area and high porosity 3D platform for molecular imprinted polymer (MIP), especially for surface imprinting. The thickness of polymer grafted around each CNT can be fine-tuned to imprint different sizes of target molecules, and yet it can be thin enough to expose every imprint site to the target molecules in solution without sacrificing the capacity of binding sites. The performance of this new CNT-MIP architecture was first assessed with a caffeine-imprinted polypyrrole (PPy) coating on two types of CNT arrays: sparse and dense CNTs. Real-time pulsed amperometric detection was used to study the rebinding of the caffeine molecules onto these CNT-MIPPy sensors. The dense CNT-MIPPy sensor presented the highest sensitivity, about 15 times better when compared to the conventional thin film, whereas an improvement of 3.6 times was recorded on the sparse CNT. However, due to the small tube-to-tube spacing in the dense CNT array, electrode fouling was observed during the detection of concentrated caffeine in phosphate buffer solution. A new I-V characterization method using pulsed amperometry was introduced to investigate the electrical characterization of these new devices. The resistance value derived from the I-V plot provides insight into the electrical conductivity of the CNT transducer and also the effective surface area for caffeine imprinting.
Resumo:
This review is about the development of three-dimensional (3D) ultrasonic medical imaging, how it works, and where its future lies. It assumes knowledge of two-dimensional (2D) ultrasound, which is covered elsewhere in this issue. The three main ways in which 3D ultrasound may be acquired are described: the mechanically swept 3D probe, the 2D transducer array that can acquire intrinsically 3D data, and the freehand 3D ultrasound. This provides an appreciation of the constraints implicit in each of these approaches together with their strengths and weaknesses. Then some of the techniques that are used for processing the 3D data and the way this can lead to information of clinical value are discussed. A table is provided to show the range of clinical applications reported in the literature. Finally, the discussion relating to the technology and its clinical applications to explain why 3D ultrasound has been relatively slow to be adopted in routine clinics is drawn together and the issues that will govern its development in the future explored.
Resumo:
The paper deals with an experiment with a floating trawl net off Cochin, using a pair of curved otter boards and a transducer mounted on the head rope of the net. 32 hauls were made with different towing speeds and warp length keeping one factor constant for varying parameters of the other factor. The working data for 32 hauls are presented and the effect in the fishing depth of the net due to the variation in one factor is mentioned. The 'fishing depth' is indicated in this paper as the distance between the head rope and the bottom. The usefulness of similar experiments with added information on the angle of leading warp at the stern for the exploitation of column fishes in Indian waters is indicated.
Resumo:
A portable self-contained instrument has been designed and developed for the measurement of the Fore and Aft tilt of otter boards within the range —22° to + 22° with an accuracy of ± 1°. An underwater transducer fitted on the otter board converts its tilt into corresponding electrical resistance which is measured in an ohmmeter on board, both being connected by electric cable.