Shock tube study of JP-10 ignition delay time


Autoria(s): 王苏; 勾华杰; 范秉诚; 何宇中; Zhang ST; 崔季平
Data(s)

2007

Resumo

JP-10 (exo-tetrahydrodicyclopentadiene, C10H16) ignition delay times were measured in a preheated shock tube. The vapor pressures of the JP-10 were measured directly by using a high-precision vacuum gauge, to remedy the difficulty in determining the gaseous concentrations of heavy hydrocarbon fuel arising from the adsorption on the wall in shock tube experiments. The whole variation of pressure and emission of the OH or CH radicals were observed in the ignition process by a pressure transducer and a photomultiplier with a monochromator. The emission of the OH or CH radicals was used to identify the time to ignition. Experiments were performed over the pressure range of 151-556 kPa, temperature range of 1000-2100 K, fuel concentrations of 0.1%-0.55% mole fraction, and stoichiometric ratios of 0.25, 0.5, 1.0 and 2.0. The experimental results show that for the lower and higher temperature ranges, there are different dependency relationships of the ignition time on the temperature and the concentrations of JP-10 and oxygen.

Identificador

http://dspace.imech.ac.cn/handle/311007/34017

http://www.irgrid.ac.cn/handle/1471x/2857

Idioma(s)

英语

Fonte

Chinese Journal of Chemical Physics.2007,20(1):48-52

Palavras-Chave #Ignition Delay Time #Jp-10 #Shock Tube #N-Heptane #Mixtures #Autoignition #Oxidation #Kinetics #Fuels
Tipo

期刊论文