902 resultados para Topics Extraction
Resumo:
OBJECTIVE: To analyze the results of laser-assisted extraction of permanent pacemaker and defibrillator leads. METHODS: We operated upon 36 patients, whose mean age was 54.2 years, and extracted 56 leads. The reasons for extracting the leads were as follows: infection in 19 patients, elective replacement in 13, and other causes in 4 patients. The mean time of catheter placement was 7.5±5.5 years. Forty-seven leads were from pacemakers, and 9 were from defibrillators. Thirty-eight leads were in use, 14 had been abandoned in the pacemaker pocket, and 4 had been abandoned inside the venous system. RESULTS: We successfully extracted 54 catheters, obtaining a 96.4% rate of success and an 82.1% rate for complete extraction. The 2 unsuccessful cases were due to the presence of calcium in the trajectory of the lead. The mean duration of laser light application was 123.0±104.5 s, using 5,215.2±4,924.0 pulses, in a total of 24.4±24.2 cycles of application. Thirty-four leads were extracted from the myocardium with countertraction after complete progression of the laser sheath, 12 leads came loose during the progression of the laser sheath, and the remaining 10 were extracted with other maneuvers. One patient experienced cardiac tamponade after extraction of the defibrillator lead, requiring open emergency surgery. CONCLUSION: The use of the excimer laser allowed extraction of the leads with a 96% rate of success; it was not effective in 2 patients who had calcification on the lead. One patient (2.8%) had a complication that required cardiac surgery on an emergency basis.
Resumo:
A composting Heat Extraction Unit (HEU) was designed to utilise waste heat from decaying organic matter for a variety of heating application The aim was to construct an insulated small scale, sealed, organic matter filled container. In this vessel a process fluid within embedded pipes would absorb thermal energy from the hot compost and transport it to an external heat exchanger. Experiments were conducted on the constituent parts and the final design comprised of a 2046 litre container insulated with polyurethane foam and kingspan with two arrays of qualpex piping embedded in the compost to extract heat. The thermal energy was used in horticultural trials by heating polytunnels using a radiator system during a winter/spring period. The compost derived energy was compared with conventional and renewable energy in the form of an electric fan heater and solar panel. The compost derived energy was able to raise polytunnel temperatures to 2-3°C above the control, with the solar panel contributing no thermal energy during the winter trial and the electric heater the most efficient maintaining temperature at its preset temperature of 10°C. Plants that were cultivated as performance indicators showed no significant difference in growth rates between the heat sources. A follow on experiment conducted using special growing mats for distributing compost thermal energy directly under the plants (Radish, Cabbage, Spinach and Lettuce) displayed more successful growth patterns than those in the control. The compost HEU was also used for more traditional space heating and hot water heating applications. A test space was successfully heated over two trials with varying insulation levels. Maximum internal temperature increases of 7°C and 13°C were recorded for building U-values of 1.6 and 0.53 W/m2K respectively using the HEU. The HEU successfully heated a 60 litre hot water cylinder for 32 days with maximum water temperature increases of 36.5°C recorded. Total energy recovered from the 435 Kg of compost within the HEU during the polytunnel growth trial was 76 kWh which is 3 kWh/day for the 25 days when the HEU was activated. With a mean coefficient of performance level of 6.8 calculated for the HEU the technology is energy efficient. Therefore the compost HEU developed here could be a useful renewable energy technology particularly for small scale rural dwellers and growers with access to significant quantities of organic matter
Resumo:
feature extraction, feature tracking, vector field visualization
Resumo:
Magdeburg, Univ., Fak. für Informatik, Diss., 2009
Resumo:
Michael Friebe, editor ; Otto-von-Guericke-Universität Magdeburg, Institut für Medizintechnik, Lehrstuhl Kathetertechnologie und bildgesteuerte Therapie (INKA - Intelligente Katheter), Forschungscampus STIMULATE (Solution Centre for Image Guided Local Therapies)
Resumo:
Estudi elaborat a partir d’una estada a Xerox Research Centre Europe a Grenoble, França,entre juny i desembre del 2006. El projecte tradueïx termes tècnics anglesos a noruec. És asimètric perquè no tenim recursos lingüístics per a la llengua noruega, però solament per a l'anglès. S’ha desenvolupat i posat en pràctica mètodes que comprovaven contigüitat ("local reordering" i permutació selectiva) per a millorar el funcionament d’una eina anterior. Contigüitat és quan una paraula es traduïx en paraules múltiples, aquestes paraules han de ser adjacents en l'oració. A més, s’ha construït una taula de les operacions de recerca per als termes tècnics i s’ha integrat aquesta taula en un programa de demostració.
Resumo:
Solubilization of Schistosoma mansoni antigens was obtained by agitation of adult worms in a 3M KCl solution. The protein contents of the KCl extrats varied from 0.35 to 0.96 mg/ml. Sera from 97 patients with hepatointestinal shistosomiasis and viable eggs in stools from a Brazilian endemic area were studied by immunoelectroomophoresis and Ouchterlony immunodiffusion methods with the KCl extract and with another antigen, obtained by homogenization of adult schistosomes in saline. The rate of positiveness of immunoprecipitation deterctions by immunoelectroomophoresis with the KCl extract was 53.5%. A correlation was verified between methods of detection and extration procedures, resulting in a better association of the extract obtained by agitation in 3M KCl and immunoelectroomophoresis.
Resumo:
We present a new method for lysis of single cells in continuous flow, where cells are sequentially trapped, lysed and released in an automatic process. Using optimized frequencies, dielectrophoretic trapping allows exposing cells in a reproducible way to high electrical fields for long durations, thereby giving good control on the lysis parameters. In situ evaluation of cytosol extraction on single cells has been studied for Chinese hamster ovary (CHO) cells through out-diffusion of fluorescent molecules for different voltage amplitudes. A diffusion model is proposed to correlate this out-diffusion to the total area of the created pores, which is dependent on the potential drop across the cell membrane and enables evaluation of the total pore area in the membrane. The dielectrophoretic trapping is no longer effective after lysis because of the reduced conductivity inside the cells, leading to cell release. The trapping time is linked to the time required for cytosol extraction and can thus provide additional validation of the effective cytosol extraction for non-fluorescent cells. Furthermore, the application of one single voltage for both trapping and lysis provides a fully automatic process including cell trapping, lysis, and release, allowing operating the device in continuous flow without human intervention.
Resumo:
This work covers two aspects. First, it generally compares and summarizes the similarities and differences of state of the art feature detector and descriptor and second it presents a novel approach of detecting intestinal content (in particular bubbles) in capsule endoscopy images. Feature detectors and descriptors providing invariance to change of perspective, scale, signal-noise-ratio and lighting conditions are important and interesting topics in current research and the number of possible applications seems to be numberless. After analysing a selection of in the literature presented approaches, this work investigates in their suitability for applications information extraction in capsule endoscopy images. Eventually, a very good performing detector of intestinal content in capsule endoscopy images is presented. A accurate detection of intestinal content is crucial for all kinds of machine learning approaches and other analysis on capsule endoscopy studies because they occlude the field of view of the capsule camera and therefore those frames need to be excluded from analysis. As a so called “byproduct” of this investigation a graphical user interface supported Feature Analysis Tool is presented to execute and compare the discussed feature detectors and descriptor on arbitrary images, with configurable parameters and visualized their output. As well the presented bubble classifier is part of this tool and if a ground truth is available (or can also be generated using this tool) a detailed visualization of the validation result will be performed.
Resumo:
In order to evaluate the effect of chaotropic agents on proteoglycan and non-collagenous proteins, chicken xiphoid cartilage was treated with guanidine-HCI and MgCl2 in different concentrations (1M to 5M), and different periods of time (12, 24, 48 and 72hr). The maximum yield of uronic acid was obtained with 3M MgCl2 (73.3 per cent). Concentrations of 4M and 5M of MgCl2 showed that much less uronic acid was removed, 55.3 per cent and 38.1 respectively. Extraction with 3M MgCl2 and 3M guanidine-HCl resulted better efficiency when performed for 48 hr. Analysis by SDS-PAGE of the extracts obtained with guanidine-HCl and MgCl, in different concentrations pointed out that most components are equally removed with the two solvents, showing that the extraction with MgCl2 is an alternative assay to remove non-collagenous proteins from extracellular matrix.
Resumo:
Estimating the time since the last discharge of firearms and/or spent cartridges may be a useful piece of information in forensic firearm-related cases. The current approach consists of studying the diffusion of selected volatile organic compounds (such as naphthalene) released during the shooting using solid phase micro-extraction (SPME). However, this technique works poorly on handgun car-tridges because the extracted quantities quickly fall below the limit of detection. In order to find more effective solutions and further investigate the aging of organic gunshot residue after the discharge of handgun cartridges, an extensive study was carried out in this work using a novel approach based on high capacity headspace sorptive extraction (HSSE). By adopting this technique, for the first time 51 gunshot residue (GSR) volatile organic compounds could be simultaneously detected from fired handgun cartridge cases. Application to aged specimens showed that many of those compounds presented significant and complementary aging profiles. Compound-to-compound ratios were also tested and proved to be beneficial both in reducing the variability of the aging curves and in enlarging the time window useful in a forensic casework perspective. The obtained results were thus particularly promising for the development of a new complete forensic dating methodology.