969 resultados para Surgical Procedures,Minimally Invasive


Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Partial splenectomy in children is a good surgical option for hematological diseases and focal splenic tumors because it allows the preservation of the spleen's immunological function. Furthermore, it can be performed by laparoscopy in children as it is a safe procedure, offering the benefits of a minimally invasive approach. MATERIALS AND METHODS: The software VR-render LE version 0.81 is a system that enables the visualization of bidimentional 3D images with magnification of anatomical details. We have applied this system to five cases of non-parasitic splenic cysts before laparoscopic partial splenectomy. RESULTS: The images obtained with VR rendering software permitted the preoperative reconstruction of the vascularization of the splenic hilum, allowing the surgeon safe vessel control during laparoscopic procedures. All five partial splenectomies were carried out with no complications or major blood loss. CONCLUSIONS: Laparoscopic partial splenectomy should be a first choice procedure because it is feasible, reproducible, and safe for children; furthermore, it preserves enough splenic tissue thereby preventing post-splenectomy infections. Volume rendering provides high anatomical resolution and can be useful in guiding the surgical procedure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: Enhanced recovery after surgery (ERAS) pathways have significantly reduced complications and length of hospital stay after colorectal procedures. This multimodal concept could probably be partially applied to major urological surgery. OBJECTIVES: The primary objective was to systematically assess the evidence of ERAS single items and protocols applied to cystectomy patients. The secondary objective was to address a grade of recommendation to each item, based on the evidence and, if lacking, on consensus opinion from our ERAS Society working group. EVIDENCE ACQUISITION: A systematic literature review was performed on ERAS for cystectomy by searching EMBASE and Medline. Relevant articles were selected and quality-assessed by two independent reviewers using the GRADE approach. If no study specific to cystectomy was available for any of the 22 given items, the authors evaluated whether colorectal guidelines could be extrapolated. EVIDENCE SYNTHESIS: Overall, 804 articles were retrieved from electronic databases. Fifteen articles were included in the present systematic review and 7 of 22 ERAS items were studied. Bowel preparation did not improve outcomes. Early nasogastric tube removal reduced morbidity, bowel recovery time and length of hospital stay. Doppler-guided fluid administration allowed for reduced morbidity. A quicker bowel recovery was observed with a multimodal prevention of ileus, including gum chewing, prevention of PONV and minimally invasive surgery. CONCLUSIONS: ERAS has not yet been widely implemented in urology and evidence for individual interventions is limited or unavailable. The experience in other surgical disciplines encourages the development of an ERAS protocol for cystectomy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dermatologic surgery has evolved enormously within the past few years especially for the treatment of varicose veins and telangiectasias. New minimally-invasive techniques have been developed: lasers, echo-sclerosis, surgery with tumescent anesthesia and endovascular treatment of saphenous veins. Most interventions can be performed with local anesthesia in the office setting. These new treatments are intended to decrease the risks of surgery, reduce medical costs and the necessity for hospitalization, and improve functional and esthetic results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chronic low back pain attributed to lumbar disc degeneration poses a serious challenge to physicians. Surgery may be indicated in selected cases following failure of appropriate conservative treatment. For decades, the only surgical option has been spinal fusion, but its results have been inconsistent. Some prospective trials show superiority over usual conservative measures while others fail to demonstrate its advantages. In an effort to improve results of fusion and to decrease the incidence of adjacent segment degeneration, total disc replacement techniques have been introduced and studied extensively. Short-term results have shown superiority over some fusion techniques. Mid-term results however tend to show that this approach yields results equivalent to those of spinal fusion. Nucleus replacement has gained some popularity initially, but evidence on its efficacy is scarce. Dynamic stabilisation, a technique involving less rigid implants than in spinal fusion and performed without the need for bone grafting, represents another surgical option. Evidence again is lacking on its superiority over other surgical strategies and conservative measures. Insertion of interspinous devices posteriorly, aiming at redistributing loads and relieving pain, has been used as an adjunct to disc removal surgery for disc herniation. To date however, there is no clear evidence on their efficacy. Minimally invasive intradiscal thermocoagulation techniques have also been tried, but evidence of their effectiveness is questioned. Surgery using novel biological solutions may be the future of discogenic pain treatment. Collaboration between clinicians and basic scientists in this multidisciplinary field will undoubtedly shape the future of treating symptomatic disc degeneration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: Benign Oral Vascular Lesions (BOVLs) are a group of vascular diseases characterized by congenital, inflammatory or neoplastic vascular dilations clinically evidenced as more or less wide masses of commonly dark bluish color. If traumatized BOVLs are characterized by a great risk of hemorrhage and their treatment usually requires great caution to prevent massive bleeding. In the last decades lasers have dramatically changed the way of treatment of BOVLs permitting the application of even peculiar techniques that gave interesting advantages in their management reducing hemorrhage risks. The aim of this study was to evaluate the capabilities and disadvantages of three laser assisted techniques in the management of BOVLs. Study design: In this study 13 BOVLs were treated by three different laser techniques: the traditional excisional biopsy (EB), and two less invasive techniques, the transmucosal thermocoagulation (TMT) and the intralesional photocoagulation (ILP). Two different laser devices were adopted in the study: a KTP laser (DEKA, Florence, Italy, 532nm) and a GaAlAs laser (Laser Innovation, Castelgandolfo, Italy, 808nm) selected since their great effectiveness on hemoglobin. Results: In each case, lasers permitted safe treatments of BOVLs without hemorrhages, both during the intervention and in the post-operative period. The minimally invasive techniques (TMT and ILP) permitted even the safe resolution of big lesions without tissue loss. Conclusions: Laser devices confirm to be the gold standard in BOVLs treatment, permitting even the introduction of minimal invasive surgery principles and reducing the risks of hemorrhage typical of these neoplasms. As usual in laser surgery, it is necessary a clear knowledge of the devices and of the laser-tissue interaction to optimize the results reducing risks and disadvantages

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND AIM OF THE STUDY: Transapical transcatheter aortic valve replacement (TAVR) is a new minimally invasive technique with a known risk of unexpected intra-procedural complications. Nevertheless, the clinical results are good and the limited amount of procedural adverse events confirms the usefulness of a synergistic surgical/anesthesiological management in case of unexpected emergencies. METHODS: A review was made of the authors' four-year database and other available literature to identify major and minor intra-procedural complications occurring during transapical TAVR procedures. All implants were performed under general anesthesia with a balloon-expandable Edwards Sapien stent-valve, and followed international guidelines on indications and techniques. RESULTS: Procedural success rates ranged between 94% and 100%. Life-threatening apical bleeding occurred very rarely (0-5%), and its incidence decreased after the first series of implants. Stent-valve embolization was also rare, with a global incidence ranging from 0-2%, with evidence of improvement after the learning curve. Rates of valve malpositioning ranged from 0% to < 3%, whereas the risk of coronary obstruction ranged from 0% to 3.5%. Aortic root rupture and dissection were dramatic events reported in 0-2% of transapical cases. Stent-valve malfunction was rarely reported (1-2%), whereas the valve-in-valve bailout procedure for malpositioning, malfunctioning or severe paravalvular leak was reported in about 1.0-3.5% of cases. Sudden hemodynamic management and bailout procedures such as valve-in-valve rescue or cannulation for cardiopulmonary bypass were more effective when planned during the preoperative phase. CONCLUSION: Despite attempts to avoid pitfalls, complications during transapical aortic valve procedures still occur. Preoperative strategic planning, including hemodynamic status management, alternative cannulation sites and bailout procedures, are highly recommended, particularly during the learning curve of this technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: Transapical transcatheter valve procedures are performed through a left minithoracotomy and require apical sutures to seal the apical access site. The use of large-calibre devices compromises any attempt to fully perform the procedure with a thoracoscopic approach or percutaneously. We report our preliminary experience in animals with a new sutureless self-expandable apical occluder, engineered to perform transapical access site closure in a minimally invasive setting with large-size introducer sheaths. METHODS: The apical occluder with extendable waist was implanted in six young pigs during an acute animal study. Under general anaesthesia, animals (mean weight: 62 ± 8 kg) received full heparinization (heparin: 100 UI/kg; activated clotting time above 250 s). Through a median sternotomy, a 21-Fr Certitude? introducer sheath (outer diameter: 25 Fr) was placed over the wire into the cardiac apex. The delivery catheter carrying the constrained apical plug was inserted into the sheath and deployed under fluoroscopic control, whereas the Certitude? was retrieved. After protamine infusion, we observed and recorded the 1-h bleeding with standard haemodynamic parameters. Animals were sacrificed, and hearts analysed. RESULTS: Six apical closure devices were successfully introduced and deployed in six pig hearts through large-size apical sheaths at first attempt. In all animals, the plugs guaranteed immediate apical sealing and traces of blood were collected in the pericardium during the 1-h observational period (mean of 16 ± 3.4 ml of blood loss per animal). Haemodynamic parameters remained stable during the entire study period and no plug dislodgement was detected with normal systemic blood pressure (mean arterial mean blood pressure: 65 ± 7 mmHg). Post-mortem analysis confirmed the full deployment and good fixation of all plugs, without macroscopic damages to the surrounding myocardium. CONCLUSIONS: This sutureless self-expandable apical occluder is a simple device capable of sealing large-size apical access sites (20-35 Fr) in an acute animal study. This approach is a step further towards less invasive transapical valve procedures in the clinical setting, and further animal tests will be performed to confirm the long-term efficacy and safety of this device.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Various options for surgical treatment of morbid obesity have been developed with varying results: vertical banded gastroplasty with intestinal by-pass, disabsorptive surgeries and laparoscopic adjustable gastric banding. Although all of them have been effective in weight loss, lower rates of early and late postoperative complications have been described in some procedures. Laparoscopic adjustable silicone gastric banding (LASGB) has a similar principle as vertical banded gastroplasty and it is a minimally invasive procedure, with low systemic and operative problems, but not free of them. We report two rare cases of this complications of LASGB.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Réalisé sous la co-direction des Drs Denis Bouchard et Michel Pellerin

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introducción: La cirugía laparoscópica ocupa un lugar privilegiado dentro de la cirugía mínimamente invasiva, brindando al paciente y a las instituciones hospitalarias importantes beneficios comparados con la cirugía convencional. Los cirujanos en formación deben contar con un entrenamiento adecuado en cirugía laparoscópica basado en simuladores previo a la práctica con pacientes, disminuyendo la morbimortalidad derivada de la curva de aprendizaje. Este estudio busca describir e identificar los cambios en habilidades y tiempos quirúrgicos antes y después del entrenamiento con simulador de bajo costo y simulador virtual. Metodología: Se realizó un seudoexperimento (antes y después) con 20 residentes de los cuales 18 completaron el estudio, quienes recibieron un entrenamiento dirigido para la realización de procedimientos por vía laparoscópica en simuladores. El análisis estadístico se realiza mediante un análisis uni y bivariado, y se determina la significancia estadística con la medición de X2 y prueba exacta de Fisher así como la prueba T Student para muestras emparejadas y Wilcoxon para las variables numéricas. Resultados: El simulador de bajo costo muestra dependencia en la variable de manejo de tejidos en el ejercicio 3 y 10, con valores de p=0.035, y p=0.028 respectivamente. El 60% de los ejercicios muestra una diferencia estadísticamente significativa en el tiempo empleado en las pruebas. Para simulador virtual, todos los ejercicios mostraron diferencias significativas en al menos una de las variables evaluadas. Conclusiones: El entrenamiento, tanto con el simulador de bajo costo como con el simulador virtual, mejora las habilidades quirúrgicas necesarias para la realización de un procedimiento laparoscópico.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introducción: El conocimiento actual de la fisiopatología del envejecimiento periorbitario justifica la aplicación de materiales de relleno inyectables, dado que se enfocan en la restauración del volumen perdido en esta zona, convirtiéndose en una excelente alternativa a procedimientos quirúrgicos que remueven el tejido excedente. Sin embargo los efectos y la seguridad de esta naciente tendencia terapéutica aún no se sustentan en una sólida base científica. El objetivo de esta revisión es identificar el material de relleno inyectable más adecuado para el manejo de los defectos volumétricos estéticos de la región periorbitaria. Metodología: Se realizó una búsqueda exhaustiva de los artículos indexados publicados del 1º de enero de 2.000 al 30 de septiembre de 2.013, en diversas bases de datos electrónicas, se seleccionaron catorce publicaciones, se extrajo la información referente a datos demográficos, la intervención, el seguimiento y los desenlaces y se realizó un análisis de 14 estudios que cumplieron los criterios. Resultados: Todos los artículos incluidos poseían un bajo nivel de evidencia y del grado de recomendación. Todos los materiales de relleno se asociaron a altos niveles de satisfacción para el paciente, adecuada mejoría de la apariencia estética y similares efectos colaterales, el ácido hialurónico fue el material de relleno inyectable más utilizado en la región periorbitaria. Discusión: Los materiales de relleno inyectable mejoran los defectos volumétricos estéticos de la región periorbitaria pero es necesaria mayor evidencia para determinar el tipo relleno más apropiado para esta condición.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El canal lumbar estrecho de tipo degenerativo, es una enfermedad que se presenta en pacientes entre la quinta y la sexta década de vida; es la causa más común de cirugía lumbar después de los 65 años. Este trabajo busca determinar cuáles son los factores asociados a la presentación de eventos adversos o re-intervención en cirugía de canal lumbar estrecho en la Fundación Santa Fe de Bogotá en los años comprendidos entre 2003 y 2013. Métodos: se realizó un estudio de prevalencia de tipo analítico, en donde se analizaron 249 pacientes sometidos a intervención quirúrgica por cirugía de canal lumbar estrecho.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

THE clinical skills of medical professionals rely strongly on the sense of touch, combined with anatomical and diagnostic knowledge. Haptic exploratory procedures allow the expert to detect anomalies via gross and fine palpation, squeezing, and contour following. Haptic feedback is also key to medical interventions, for example when an anaesthetist inserts an epidural needle, a surgeon makes an incision, a dental surgeon drills into a carious lesion, or a veterinarian sutures a wound. Yet, current trends in medical technology and training methods involve less haptic feedback to clinicians and trainees. For example, minimally invasive surgery removes the direct contact between the patient and clinician that gives rise to natural haptic feedback, and furthermore introduces scaling and rotational transforms that confuse the relationship between movements of the hand and the surgical site. Similarly, it is thought that computer-based medical simulation and training systems require high-resolution and realistic haptic feedback to the trainee for significant training transfer to occur. The science and technology of haptics thus has great potential to affect the performance of medical procedures and learning of clinical skills. This special section is about understanding

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Designing surgical instruments for robotic-assisted minimally-invasive surgery (RAMIS) is challenging due to constraints on the number and type of sensors imposed by considerations such as space or the need for sterilization. A new method for evaluating the usability of virtual teleoperated surgical instruments based on virtual sensors is presented. This method uses virtual prototyping of the surgical instrument with a dual physical interaction, which allows testing of different sensor configurations in a real environment. Moreover, the proposed approach has been applied to the evaluation of prototypes of a two-finger grasper for lump detection by remote pinching. In this example, the usability of a set of five different sensor configurations, with a different number of force sensors, is evaluated in terms of quantitative and qualitative measures in clinical experiments with 23 volunteers. As a result, the smallest number of force sensors needed in the surgical instrument that ensures the usability of the device can be determined. The details of the experimental setup are also included.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Zygomatic arch fractures often occur as part of a zygoma fracture or Le Fort type III fractures of the maxillary. Isolated fractures of the zygomatic arch comprise around 10% of all zygoma fractures. The main etiologic factors are traffic accidents, falls, assaults, and sport accidents. Treatment may involve minimally invasive surgical procedures for slightly dislocated fractures or surgery with more extensive access for large dislocations of bone segments. This article reports the case of a 41-year-old male victim of physical aggression to the face with a steel sickle with an exposed, unstable fracture of the zygomatic arch. The patient underwent general anesthesia, and after the reduction of the fractures, the bone segments were fixed with 2.0-mm screws.