1000 resultados para Sistemas de medição
Resumo:
This study developed software rotines, in a system made basically from a processor board producer of signs and supervisory, wich main function was correcting the information measured by a turbine gas meter. This correction is based on the use of an intelligent algorithm formed by an artificial neural net. The rotines were implemented in the habitat of the supervisory as well as in the habitat of the DSP and have three main itens: processing, communication and supervision
Resumo:
The Oil Measurement Evaluation Laboratory (LAMP), located in the Federal University of Rio Grande do Norte (UFRN), has as main goal to evaluate flow and BS&W meters, where the simulation of a bigger number of operation variable in field, guarantees a less uncertain evaluation. The objective of this work is to purpose a heating system design and implementation, which will control the temperature safely and efficiently in order to evaluate and measure it. Temperature is one of the variables which influence the flow and BS&W accurate measurement, directly affecting the fluid viscosity and density in the experiment. To project the heating system it is of great importance to take the laboratory requirements, conditions and current restrictions into consideration. Three alternatives were evaluated: heat exchanger, internal resistance and external resistance. After the analyses are made in order to choose the best alternative for the heating system in the laboratory, control strategies were determined for it, PID control methods in combination with fuzzy logic were used. Results showed a better performance with fuzzy logic than with classic PID
Resumo:
The characteristic properties of the fractal geometry have shown to be very useful for the construction of filters, frequency selective surfaces, synchronized circuits and antennas, enabling optimized solutions in many different commercial uses at microwaves frequency band. The fractal geometry is included in the technology of the microwave communication systems due to some interesting properties to the fabrication of compact devices, with higher performance in terms of bandwidth, as well as multiband behavior. This work describes the design, fabrication and measurement procedures for the Koch quasi-fractal monopoles, with 1 and 2 iteration levels, in order to investigate the bandwidth behavior of planar antennas, from the use of quasi-fractal elements printed on their rectangular patches. The electromagnetic effect produced by the variation of the fractal iterations and the miniaturization of the structures is analyzed. Moreover, a parametric study is performed to verify the bandwidth behavior, not only at the return loss but also in terms of SWR. Experimental results were obtained through the accomplishment of measurements with the aid of a vetorial network analyzer and compared to simulations performed using the Ansoft HFSS software. Finally, some proposals for future works are presented
Resumo:
This dissertation has the purpose to present a portable device named PlugData MG100G, equipped with a cellular module, to analyze the radiofrequency coverage in a GSM network situated in João Pessoa city, state of Paraíba, at four distinct regions. The equipment, originally, was developed to be used in fixed environments, so it was adapted so that it could be used in conditions of mobility. From the Mobile Measurement Reports (MMRs) RF coverage and the handover process are analyzed. The MMRs enable the identification of the serving cell and the list of the closest neighboring cells monitored by the mobile. This work analyses only data referent to the serving cell and the two closest neighboring cells. Inter-cell and intra-cell handovers are identified. The frequency planning and quality of service offered by the network related to the regions are discussed as well
Resumo:
The objective of this research is to discuss about the need for implementation of new alternatives for the implementation on the metrological control: on the findings of initial and subsequent measurements, the control procedures of measurement uncertainty applied in assessing the loss or remains found in handling operations of bulk liquids, when used turbine meters used in measuring the tax on the business of Petrobras, due to the current environment of legal metrology and scientific, both domestic and international. We aim, with these alternatives: standardizing the minimization of random and systematic errors, the estimate of the remaining errors, as well as the management control of metrological calibration procedures, control of measurement uncertainty, and contribute to the change in the form of performance of legal metrology and scientific disseminating new information to change management of metrological control, objectively focused on aspects of supervision in implementing these activities in the control of the uncertainties of measurement used in our processes in the fiscal measurement system Petrobras. Results are presented, information and comments on the influence of measurement uncertainty in the current results of the fiscal and transfer of custody. This will emphasize the need, among other things, improvement and expansion of metrological control monitored by setting a better meet demand, calibration equipment and measuring instruments for Petrobras. Finally, we intend to establish the need for improving the method of evaluation of the data meter applied to the current management control of measurement uncertainty by proposing a methodology for addressing the problem, as well as highlighting the expected results.
Resumo:
The considered work presents the procedure for evaluation of the uncertainty related to the calibration of flow measurers and to BS&W. It is about a new method of measurement purposed by the conceptual project of the laboratory LAMP, at Universidade Federal do Rio Grande do Norte, that intends to determine the conventional true value of the BS&W from the total height of the liquid column in the auditor tank, hydrostatic pressure exerted by the liquid column, local gravity, specific mass of the water and the specific mass of the oil, and, to determine the flow, from total height of liquid column and transfer time. The calibration uses a automatized system of monitoration and data acquisition of some necessary largnesses to determine of flow and BS&W, allowing a better trustworthiness of through measurements
Resumo:
This work holds the purpose of presenting an auxiliary way of bone density measurement through the attenuation of electromagnetic waves. In order to do so, an arrangement of two microstrip antennas with rectangular configuration has been used, operating in a frequency of 2,49 GHz, and fed by a microstrip line on a substrate of fiberglass with permissiveness of 4.4 and height of 0,9 cm. Simulations were done with silica, bone meal, silica and gypsum blocks samples to prove the variation on the attenuation level of different combinations. Because of their good reproduction of the human beings anomaly aspects, samples of bovine bone were used. They were subjected to weighing, measurement and microwave radiation. The samples had their masses altered after mischaracterization and the process was repeated. The obtained data were inserted in a neural network and its training was proceeded with the best results gathered by correct classification on 100% of the samples. It comes to the conclusion that through only one non-ionizing wave in the 2,49 GHz zone it is possible to evaluate the attenuation level in the bone tissue, and that with the appliance of neural network fed with obtained characteristics in the experiment it is possible to classify a sample as having low or high bone density
Resumo:
Incluye Bibliografía
Resumo:
Incluye Bibliografía
Resumo:
Incluye Bibliografía
Resumo:
Incluye Bibliografía
Resumo:
Incluye Bibliografía
Resumo:
Incluye Bibliografía
Resumo:
Prólogo de Alicia Bárcena
Resumo:
Incluye Bibliografía