954 resultados para Shoulder injuries


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To report the magnetic resonance imaging (MRI) findings in athletic injuries of the extensor carpi ulnaris (ECU) subsheath, assessing the utility of gadolinium-enhanced (Gd) fat-saturated (FS) T1-weighted sequences with wrist pronation and supination. METHODS: Sixteen patients (13 male, three female; mean age 30.3 years) with athletic injuries of the ECU subsheath sustained between January 2003 and June 2009 were included in this retrospective study. Initial and follow-up 1.5-T wrist MRIs were performed with transverse T1-weighted and STIR sequences in pronation, and Gd FS T1-weighted sequences with wrist pronation and supination. Two radiologists assessed the type of injury (A to C), ECU tendon stability, associated lesions and rated pulse sequences using a three-point scale: 1=poor, 2=good and 3=excellent. RESULTS: Gd-enhanced FS T1-weighted transverse sequences in supination (2.63) and pronation (2.56) were most valuable, compared with STIR (2.19) and T1-weighted (1.94). Nine type A, one type B and six type C injuries were found. There were trends towards diminution in size, signal intensity and enhancement of associated pouches on follow-up MRI and tendon stabilisation within the ulnar groove. CONCLUSION: Gd-enhanced FS T1-weighted sequences with wrist pronation and supination are most valuable in assessing and follow-up athletic injuries of the ECU subsheath on 1.5-T MRI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Articular surfaces reconstruction is essential in total shoulder arthroplasty. Because of the limited glenoid bone support, thin glenoid component could improve anatomical reconstruction, but adverse mechanical effects might appear. METHODS: With a numerical musculoskeletal shoulder model, we analysed and compared three values of thickness of a typical all-polyethylene glenoid component: 2, 4 (reference) and 6mm. A loaded movement of abduction in the scapular plane was simulated. We evaluated the humeral head translation, the muscle moment arms, the joint force, the articular contact pattern, and the polyethylene and cement stress. Findings Decreasing polyethylene thickness from 6 to 2mm slightly increased humeral head translation and muscle moment arms. This induced a small decreased of the joint reaction force, but important increase of stress within the polyethylene and the cement mantel. Interpretation The reference thickness of 4mm seems a good compromise to avoid stress concentration and joint stuffing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Polyethylene wear is a recurrent problem in joint arthroplasty. Small debris particles are also associated to inflammation reaction of the surrounding bone, eventually leading to the failure of the bound between the implant and the host bone, and implant loosening. The goal of this study was thus to estimate the volume of polyethylene wear of a reversed prosthesis, and compare it to an anatomic prosthesis, during one year of activities of daily living. Material and Methods: A numerical musculoskeletal model of the glenohumeral joint was used for this comparative study. The reversed (RP) and anatomic (AP) Aequalis prostheses were positioned in the numerical model. Eight levels of abduction were considered. Their daily frequency was estimated from in-vivo recorded data on healthy volunteers during activities of daily living. One year of use was simulated to predict the linear and volumetric wear. The volumetric wear was the difference of volume between the original and worn component. Results: With the AP, the contact pattern on the glenoid surface moved rapidly from the inferior to the superior side during the first 30 degrees of abduction, and then went back to the inferior side. With the RP, the contact pattern on the humeral cup surface remained at the inferior side. Contact pressure was 20 times lower with the RP than with the AP. One year of use produced a maximum linear wear of 0.2 mm with the AP, and 0.13 mm with the RP. However, the volumetric wear was 8.4 mm3 with the AP, but reached 44.6 mm3 with the RP. Conclusion: Polyethylene particles are a matter of concern with AP. Infiltration of these particles within the bone-implant interface can induce a implant loosening. This problem should not be underestimated with RP. It might be associated to a higher level of humeral stem loosening reported with RP. The long term survival of RP might be improved by using a highly cross-linked polyethylene, which has a better abrasion resistance but lower plastic resistance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In clinical settings, functional evaluation of shoulder movement is primarily based on what the patient thinks he/she is able to do rather than what he/she is actually performing. We proposed a new approach for shoulder assessment based on inertial sensors to monitor arm movement in the daily routine. The detection of movement of the humerus relative to the trunk was first validated in a laboratory setting (sensitivity>95%, specificity>97%). Then, 41 control subjects and 21 patients suffering from a rotator cuff tear were evaluated (before and after surgery) using clinical questionnaires and a one-day measurement of arm movement. The quantity of movement was estimated with the movement frequency and its symmetry index (SIFr). The quality of movement was assessed using the Kolmogorov-Smirnov distance (KS) between the cumulative distribution of the arm velocity for controls and the same distribution for each patient. SIFr presented differences between patients and controls at 3 month follow-up (p<0.05) while KS showed differences also after 6 months (p<0.01). SIFr illustrated a change in dominance due to the disorder whereas KS, which appeared independent of the dominance and occupation, showed a change in movement velocity. Both parameters were correlated to clinical scores (R(2) reaching 0.5). This approach provides clinicians with new objective parameters for evaluating the functional ability of the shoulder in daily conditions, which could be useful for outcome assessment after surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Granular shoulders need to be maintained on a regular basis because edge ruts and potholes develop, posing a safety hazard to motorists. The successful mitigation of edge-rut issues for granular shoulders would increase safety and reduce the number of procedures currently required to maintain granular shoulders in Iowa. In addition, better performance of granular shoulders reduces the urgency to pave granular shoulders. Delaying or permanently avoiding paving shoulders where possible allows more flexibility in making investments in the road network. To stabilize shoulders and reduce the number of maintenance cycles necessary per season, one possible stabilizing agent—acidulated soybean oil soapstock—was investigated in this research. A pilot testing project was conducted for selected problematic shoulders in northern and northeastern Iowa. Soapstock was applied on granular shoulders and monitored during application and pre- and post-application. Application techniques were documented and the percentage of application success was calculated for each treated shoulder section. As a result of this research, it was concluded that soybean oil soapstock can be an effective stabilizer for granular shoulders under certain conditions. The researchers also developed draft specifications that could possibly be used to engage a contractor to perform the work using a maintenance-type construction contract. The documented application techniques from this project could be used as guidance for those who want to apply soapstock for stabilizing granular shoulders but might not be familiar with this technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

From August 91 to December 94, 20 external fixators were used for severely injured patients (avg. ISS 25.2). The fractures were essentially open book with or without lateral compression and vertical lesions. The indication for fixation was treatment of shock and stabilization in 8 cases, stabilization alone in 9 cases, and in 3 cases as complementary fixation after internal fixation of posterior lesions. The fixation of the pelvis was effective on the amount of blood loss. One acetabulum fracture required surgery, two patients had internal fixation for loss of reduction and two others for late pubic and posterior pain. The clinical results are good; they are more related to the severity of the initial lesion than to the mode of fixation or the quality of the reduction. No superficial sepsis or osteitis was observed in relation to the pins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Controversy still exists as to the best surgical treatment for periprosthetic shoulder infections. The aim of this multi-institutional study was to review a continuous retrospective series of patients treated in four European centres and to assess the respective eradication rate of various treatment approaches. METHODS: Forty-four patients were available for this retrospective follow-up evaluation. Functional and clinical evaluation of treatment for infection was performed using the Constant-Murley score, visual analogue scale and patient satisfaction Neer score. Erythrocyte sedimentation rate, serum leucocyte count and C-reactive protein were measured and shoulder X-ray examination performed prior to surgery and at the latest follow-up. RESULTS: At a mean follow-up of 41 months (range 24-98), 42 of 44 patients (95.5%) showed no signs of infection recurrence/persistence. Comparable eradication rates were observed after resection arthroplasty (100%; 6/6), two-stage revision (17/17) or permanent antibiotic-loaded spacer implant (93.3%; 14/15). No patient was treated by one-stage revision. On average, both functional and pain scores improved significantly; the worst joint function was observed after resection arthroplasty. CONCLUSIONS: This retrospective analysis conducted on the largest published series of patients to date shows comparable infection eradication rates after two-stage revision, resection arthroplasty or permanent spacer implant for the treatment of septic shoulder prosthesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine the frequency of recent skin injuries in children with neuromotor disabilities and its association with disability. DESIGN: Cross-sectional study of 168 children with neuromotor disabilities aged 2-16 years. SETTING: Two outpatient child rehabilitation centres. MAIN OUTCOME MEASURES: Children were classified as unrestricted walkers, restricted walkers or wheelchair dependent. Each participant's body surface was systematically examined for recent skin injuries with the exception of the anal-genital area. RESULTS: The mean age of our sample was 7.8 (SD 3.7) years with a 3:2 male/female ratio. Overall, 64% had cerebral palsy, 17% a neuromuscular disease and 19% other motor disabilities. Participants had on average 5.3 (SD 4.5) recent skin injuries (max 19), of which 2.5 were bruises (SD 3.3, max 16), 2.4 were abrasions, scratches or cuts (SD 3.0, max 16) and 0.4 were pressure lesions (SD 0.8, max 4). There was a significant decrease in the frequency of recent skin injuries and of bruises with increasing severity of motor disability. Most of this variation was accounted for by injuries to the lower limbs. There were no significant effects of gender, learning disabilities or other comorbidities. CONCLUSIONS: Children with neuromotor disabilities present a progressive reduction in the number of skin injuries with decreasing mobility. Therefore, recent skin injuries in this population which are unusual by their number, appearance or distribution, should raise at least the same level of suspicion for physical abuse as in children without disabilities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to develop an ambulatory system for the three-dimensional (3D) knee kinematics evaluation, which can be used outside a laboratory during long-term monitoring. In order to show the efficacy of this ambulatory system, knee function was analysed using this system, after an anterior cruciate ligament (ACL) lesion, and after reconstructive surgery. The proposed system was composed of two 3D gyroscopes, fixed on the shank and on the thigh, and a portable data logger for signal recording. The measured parameters were the 3D mean range of motion (ROM) and the healthy knee was used as control. The precision of this system was first assessed using an ultrasound reference system. The repeatability was also estimated. A clinical study was then performed on five unilateral ACL-deficient men (range: 19-36 years) prior to, and a year after the surgery. The patients were evaluated with the IKDC score and the kinematics measurements were carried out on a 30 m walking trial. The precision in comparison with the reference system was 4.4 degrees , 2.7 degrees and 4.2 degrees for flexion-extension, internal-external rotation, and abduction-adduction, respectively. The repeatability of the results for the three directions was 0.8 degrees , 0.7 degrees and 1.8 degrees . The averaged ROM of the five patients' healthy knee were 70.1 degrees (standard deviation (SD) 5.8 degrees), 24.0 degrees (SD 3.0 degrees) and 12.0 degrees (SD 6.3 degrees for flexion-extension, internal-external rotation and abduction-adduction before surgery, and 76.5 degrees (SD 4.1 degrees), 21.7 degrees (SD 4.9 degrees) and 10.2 degrees (SD 4.6 degrees) 1 year following the reconstruction. The results for the pathologic knee were 64.5 degrees (SD 6.9 degrees), 20.6 degrees (SD 4.0 degrees) and 19.7 degrees (8.2 degrees) during the first evaluation, and 72.3 degrees (SD 2.4 degrees), 25.8 degrees (SD 6.4 degrees) and 12.4 degrees (SD 2.3 degrees) during the second one. The performance of the system enabled us to detect knee function modifications in the sagittal and transverse plane. Prior to the reconstruction, the ROM of the injured knee was lower in flexion-extension and internal-external rotation in comparison with the controlateral knee. One year after the surgery, four patients were classified normal (A) and one almost normal (B), according to the IKDC score, and changes in the kinematics of the five patients remained: lower flexion-extension ROM and higher internal-external rotation ROM in comparison with the controlateral knee. The 3D kinematics was changed after an ACL lesion and remained altered one year after the surgery

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Absorbable anchors are frequently used in shoulder surgery. Mechanisms of absorption induce a local inflammatory reaction. It is not clear if this process may disturb healing of the capsule and ligaments. The purpose of the study was to compare the rate of recurrent dislocation following open shoulder stabilization when using absorbable or non-absorbable suture anchors. Methods: Between 1999 and 2003, 83 open Bankart repairs were performed by the same surgeon. All patients had recurrent traumatic anterior shoulder instability. All had preoperative arthro-MRI or arthro-CT which did not reveal any significant bony Bankart lesion or rotatorcuff tear. Thirty-four patients were treated with absorbable anchors (Panalok®) and sutures (Panacryl®) and 49 with non-absorbable anchors (Mitek GII®) and sutures (Ethibond®). The same surgical technique and rehabilitation protocol were used. The incidence of sports ability and recurrent instability were recorded. We defined instability as true dislocation. Results: Five patients on 34 were lost to follow-up in the absorbable group and 7 on 49 in the non-absorbable group. The mean age of absorbable group was 25 years (range, 17-39 years). At a mean follow-up of 66 months (range, 54-76 months), 86% could resume sports activity. Five patients on 29 (17%) reported recurrent instability and two did need revision surgery. The mean age in non-absorbable group was 28 year (range, 18-47 years). At a mean follow-up of 78 months (range, 49-82 months), 93% could resume sports activity. Three patients on 42 (7%) reported recurrent instability and one did need revision surgery. Conclusion: This clinical study showed a clear tendency to a higher recurrence rate of dislocation when using absorbable suture anchors (17% in absorbable vs 7% in non-absorbable group). It is known that Panacryl® may be responsible for a major local inflammatory response. However, it is still unclear if this could be the failure etiology. Consequently, we prefer to use systematically non-absorbable sutureanchors for shoulder stabilization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An increasing number of anterior cruciate ligament injuries are now seen in children and girls seem to be equally affected. Such neglected or untreated lesions could be the cause of early degenerative changes. Recently, many authors support the trend toward early surgical management in skeletally immature patients with complex meniscal tear or recurrent knee instability after proper rehabilitation. Improvement in pediatric knowledge and surgical techniques tend to support a tendency for more surgical treatment in children. The type of management is choosing according to history and physical examination. Magnetic resonance imaging is a useful tool not only for diagnosis but also for surgical treatment planning. We usually recommend anterior cruciate ligament reconstruction in children with knee instability or with further damages to the joint.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The estimation of muscle forces in musculoskeletal shoulder models is still controversial. Two different methods are widely used to solve the indeterminacy of the system: electromyography (EMG)-based methods and stress-based methods. The goal of this work was to evaluate the influence of these two methods on the prediction of muscle forces, glenohumeral load and joint stability after total shoulder arthroplasty. An EMG-based and a stress-based method were implemented into the same musculoskeletal shoulder model. The model replicated the glenohumeral joint after total shoulder arthroplasty. It contained the scapula, the humerus, the joint prosthesis, the rotator cuff muscles supraspinatus, subscapularis and infraspinatus and the middle, anterior and posterior deltoid muscles. A movement of abduction was simulated in the plane of the scapula. The EMG-based method replicated muscular activity of experimentally measured EMG. The stress-based method minimised a cost function based on muscle stresses. We compared muscle forces, joint reaction force, articular contact pressure and translation of the humeral head. The stress-based method predicted a lower force of the rotator cuff muscles. This was partly counter-balanced by a higher force of the middle part of the deltoid muscle. As a consequence, the stress-based method predicted a lower joint load (16% reduced) and a higher superior-inferior translation of the humeral head (increased by 1.2 mm). The EMG-based method has the advantage of replicating the observed cocontraction of stabilising muscles of the rotator cuff. This method is, however, limited to available EMG measurements. The stress-based method has thus an advantage of flexibility, but may overestimate glenohumeral subluxation.