301 resultados para SCREWS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate in vitro the sealing ability of the root canal using different techniques: cold lateral compaction, modified Hybrid Tagger, Thermafil and System B. Material and methods. Were used 116 human single-roots, included in resin blocks, sectioned longitudinally, attached to a device with screws and divided into four groups (n=29). After instrumentation using a bur, depression was made in each third of the root canal in each of the halves. Teeth were filled upon the different techniques. For evaluation of the quality, pictures were taken with a 1.5X magnification, photos and radiographs were utilized. After statistical analysis, were performed both macroscopic and radiographic evaluation, by Chi-square test (χ2). Results. The Thermafil technique showed better results in terms of sealing capacity, failures and homogeneity followed by modified Hybrid Tagger, the System B and cold lateral compaction. Conclusions. Thermafil was the technique that shown to be macroscopic, radiographic and homogeneously best over the other techniques evaluated in regard to the filling of the depressions made (AU)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this research study was to evaluate the structural behaviour of the wood and concrete composite system for bridge decks with emphasis on the metal shear connectors. Experimental tests were performed on composite specimens and wood and concrete beams with a metallic connector system in an X position, using CS100900-type screws. All specimens and beams were submitted to static loads until failure in order to obtain the strength and stiffness of the connection system. The experimental results for the stiffness of the beams were compared with the analytical results obtained through the Mohler model, presenting good equivalence for service loads. The experimental results obtained demonstrate that the most significant damage in composite systems occurred in the connectors' areas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study of short implants is relevant to the biomechanics of dental implants, and research on crown increase has implications for the daily clinic. The aim of this study was to analyze the biomechanical interactions of a singular implant-supported prosthesis of different crown heights under vertical and oblique force, using the 3-D finite element method. Six 3-D models were designed with Invesalius 3.0, Rhinoceros 3D 4.0, and Solidworks 2010 software. Each model was constructed with a mandibular segment of bone block, including an implant supporting a screwed metal-ceramic crown. The crown height was set at 10, 12.5, and 15 mm. The applied force was 200 N (axial) and 100 N (oblique). We performed an ANOVA statistical test and Tukey tests; p < 0.05 was considered statistically significant. The increase of crown height did not influence the stress distribution on screw prosthetic (p > 0.05) under axial load. However, crown heights of 12.5 and 15 mm caused statistically significant damage to the stress distribution of screws and to the cortical bone (p <0.001) under oblique load. High crown to implant (C/I) ratio harmed microstrain distribution on bone tissue under axial and oblique loads (p < 0.001). Crown increase was a possible deleterious factor to the screws and to the different regions of bone tissue. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ObjectiveTo study bone healing at implants installed with different insertion torques.Material and methodsIn six Labrador dogs, all mandibular premolars and first molars were extracted. After 4months of healing, flaps were elevated, and two implant sites were prepared at each side of the mandible. In the right side of the mandible, the distal sites were prepared conventionally, while the mesial sites were over-prepared by 0.2mm. As a consequence, a final insertion torque of similar to 30Ncm at the distal and a minimal insertion torque close to 0Ncm at the mesial sites were obtained. In the left sides of the mandible, however, the recipient sites were underprepared by 0.3mm resulting in an insertion torque of 70Ncm at both implants. Cover screws were applied, and flaps sutured to fully submerge the experimental sites. After 4months, the animals were sacrificed and ground sections obtained for histological evaluation.ResultsThe mineralized bone-to-implant contact was in the range of 55.2-62.1%, displaying the highest value at implants with similar to 30Ncm insertion torque and the lowest value at the implant sites with close to 0Ncm insertion torque. No statistically significant differences were revealed. Bone density was in the range of 43.4-54.9%, yielding the highest value at implants with 70Ncm insertion torque and the lowest at the implant sites with close to 0Ncm insertion torque. The difference between the sites of similar to 30Ncm and the corresponding 70Ncm insertion torque reached statistical significance.ConclusionsSimilar amounts of osseointegration were obtained irrespective of the insertion torque applied. Moreover, implants installed in sites with close to 0Ncm insertion torque may properly osseointegrate as well.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AimThe aim of this study was to evaluate the healing of autologous bone block grafts or deproteinized bovine bone mineral (DBBM) block grafts applied concomitantly with collagen membranes for horizontal alveolar ridge augmentation.Material and methodsIn six Labrador dogs, molars were extracted bilaterally, the buccal bony wall was removed, and a buccal box-shaped defect created. After 3months, a bony block graft was harvested from the right ascending ramus of the mandible and reduced to a standardized size. A DBBM block was tailored to similar dimensions. The two blocks were secured with screws onto the buccal wall of the defects in the right and left sides of the mandible, respectively. Resorbable membranes were applied at both sides, and the flaps sutured. After 3months, one implant was installed in each side of the mandible, in the interface between grafts and parent bone. After 3months, biopsies were harvested and ground sections prepared to reveal a 6-month healing period of the grafts.Results776.2% and 5.9 +/- 7.5% of vital mineralized bone were found at the autologous bone and DBBM block graft sites, respectively. Moreover, at the DBBM site, 63 +/- 11.7% of connective tissue and 31 +/- 15.5% of DBBM occupied the area analyzed. Only 0.2 +/- 0.4% of DBBM was found in contact with newly formed bone. The horizontal loss was in a mean range of 0.9-1.8mm, and 0.3-0.8mm, at the autologous bone and DBBM block graft sites, respectively.ConclusionsAutologous bone grafts were vital and integrated to the parent bone after 6months of healing. In contrast, DBBM grafts were embedded into connective tissue, and only a limited amount of bone was found inside the scaffold of the biomaterial.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate stress distribution in the fixation screws and bone tissue around implants in single-implant supported prostheses with crowns of different heights (10,12.5, 15 mm crown-to-implant ratio 1:1, 1.25:1, 1.5:1, respectively). It was designed using three 3-Dmodels. Each model was developed with a mandibular segment of bone block including an internal hexagon implant supporting a screw-retained, single metalceramic crown. The crown height was set at 10, 12.5, and 15 mm with crown-to-implant ratio of 1:1, 1.25:1, 1.5:1, respectively. The applied forces were 200 N (axial) and 100 N (oblique). The increase of crown height showed differences with the oblique load in some situations. By von Mises'criterion, a high stress area was concentrated at the implant/fixation screw and abutment/implant interfaces at crown-to-implant ratio of 1:1, 1.25:1, 1.5:1, respectively. Using the maxiinum principal criteria, the buccal regions showed higher traction stress intensity, whereas the distal regions showed the largest compressive stress in all models. The increase of C/I ratio must be carefully evaluated by the dentist since the increase of this C/I ratio is proportional to the increase of average stress for both screw fixation (C/I 1:1 to 1:1.25 ratio = 30.1% and C/I 1:1 to 1 :1.5 ratio = 46.3%) and bone tissue (C/I 1:1 to 1:1.25 ratio = 30% and C/I 1:1 to 1:1.5 ratio = 51.5%). (C) 2014 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The treatment of mandibular fractures has undergone many changes, especially after the introduction of rigid internal fixation techniques. Currently, the use of resorbable materials presents some advantages over metallic devices, particularly when applied in children. Objective: The authors discuss the controversies involved in the treatment of mandibular fractures in children, mainly related to fixation of fractures. Case Report: In this paper, we present a case of a 5 years treatment patient with mandibular angle fracture treated by open reduction and internal fixation with plates and screws. Final Comments: Aiming to not interfere in the development of tooth germs and mandibular bone growth a second surgery for removal of the fixation devices is indicated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the last decade mini-screws have gained popularity in orthodontics field and a correct placement of mini-screws is a critical point to the success of the skeletal anchorage. A careful clinical and radiographic diagnostic before insertion mini-screw is an essential requirement to achieve the central point of the radicular septum. The correct application of these pre-surgical procedures should avoid possible iatrogenic damages in periodontal ligament, dental roots, nasomaxillary cavities, or even important vascular tissues. As of today, periapical radiographs is a regular pre surgical procedure during mini-screw insertion technique. Nevertheless, accurate execution of the radiographic parallax technique can offer to us useful and precise radiographic images, to decide the right local insertion of mini-screws in to the septum bone. The purpose of this paper is to describe the ¬application of new positioning circular guides in conjunction with a ¬parallax radiographic protocol before placement of orthodontic mini-screws.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Allogeneic, fresh-frozen bone has been used in order to replace bone autografts. However, its osteoinduction and osteoconduction properties are not well-defined in the scientific literature. This work aimed to evaluate samples of homogenous bone grafts in humans by qualitative histological and immunohistochemical analysis. For this, ten pre-selected patients underwent surgical augmentation of bone defects. The homogenous fresh frozen block bone graft was stabilized and fixed by bicortical screws. After six months, the reopening procedure was performed for installation of osseointegrated implants. At this time surgical bone graft samples were removed by means of drill trephine. The samples were fixed in 10% formalin, processed with decalcified paraffin, and stained with hematoxylin and eosin. Immunohistochemistry was performed for the expression of Caspase 3 enzyme. The slides were brought to light microscopy for qualitative histology and immunohistochemistry. The results showed non-vital bone tissue, with few areas of deposition of new bone formation on the amorphous matrix, presence of chronic inflammatory infiltrate with areas of osteomyelitis, and expressive immunolabeling of Caspase 3. Given the methods employed and the results it was concluded that the allograft fresh-frozen block is not incorporated into the recipient bed after a healing period of six months.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fractures of the zygomaticomaxillary complex are among the most common face traumas. Based upon the complexity and great variety of reported diagnoses and treatments, the proposal of this study was to evaluate, clinically and radiographically, unilateral zygomatic fractures treated through internal rigid fixation with miniplates and screws of 1.5 mm. Material and Method: 15 patients with unilateral fractures of the zygomaticomaxillary complex were analyzed, and compared with 15 patients without fractures so that a comparative analysis of the area and the perimeter of the orbital cavities could be made, as well as the distance from the nasal point to the zygomatic prominence between both groups. Results: In the radiographic analysis, the both groups presented similarity in the perimeter and in the area of the orbital cavities. Concerning the distance from the nasal point to the zygomatic prominence, only the operated group showed a significant difference between the sides, even though clinically the observation of the asymmetry had been absent or discreet. Conclusions: The treatment of unilateral fractures of the zygomaticomaxillary complex with the use of plates and screws of the 1.5 mm system proved to be effective, showing good esthetic results and low complication rates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dentoalveolar traumatisms, particularly those that affect the anterior teeth, interfere adversely in the patient s life.Among them, tooth avulsion is pointed out because it is characterized as a complex injury that affects multiple tissues, andbecause there is no effective treatment available for its resolution with a stable long-term outcome.Aim/Hypothesis: The aim of the present study was to relate a clinical case of complete reconstruction of atrophy of the alveolarbone corresponding to tooth 11, lost by tooth resorption 10 years after the tooth reimplantation procedure.Material and methods: Reconstruction was performed with autogenous bone harvested from the mentum donor site. Surgicalaccess began in the receptor area with a Newman mucoperiosteal incision using a scalpel blade 15 mounted in a scalpel handlefor detachment and exposure of the receptor site. Extensive bone resorption was observed in the vestibular-palatine direction,proved by the thinness of the receptor bed. Decorticalization of the vestibular bone plate was performed. After preparing thereceptor bed, and incision was made in the mucosa in the depth of the anterior vestibular fornix, then a perpendicular muscleperiostealincision to detach and exposure the donor area. The bone graft necessary for reconstruction of the donor area wasdelimited, followed by monocortical osteotomy and the monocortical graft was removed. The next stage was to perform shapingfor passive graft accommodation and fixation by means of two bicortical screws. After fixation of the graft the sharp angles wererounded off in order to avoid possible exposure and/or fenestrations of the reconstructed area, then the receptor and donor areawere sutured. After the 6-month period to allow incorporation of the autogenous graft, an osseointegrated dental implant wasinserted. At the end of the 6-month period of waiting for osseointegration to occur, the process of fabricating the screw-retainedmetal ceramic

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG