829 resultados para Rigid gas-permeable
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Química e Bioquímica
Resumo:
Dissertação para obtenção do grau de Mestre em Engenharia Química e Bioquímica
Resumo:
Cryogen-free superconducting magnet systems have become popular during the last two decades for the simple reason that with the use of liquid helium is rather cumbersome and is a scarce resource. Some available CFMS uses a mechanical cryocooler as cold source of the superconductor magnet. However, the cooling of the sample holder is still made through an open circuit of helium. A thermal management of a completely cryogen-free system is possible to be implemented by using a controlled gas gap heat switch (GGHS) between the cryocooler and the variable temperature insert (VTI). This way it would eliminate the helium open circuit. Heat switches are devices that allow to toggle between two distinct thermal states (ON and OFF state). Several cryogenic applications need good thermal contact and a good thermal insulation at different stages of operation. A versatile GGHS was designed and built with a 100 mm gap and tested with helium as exchange gas. An analytic thermal model was developed and a good agreement with the experimental data was obtained. The device was tested on a crycooler at 4 to 80 K ranges. A 285 mW/K thermal conductance was measured at ON state and 0.09 mW/K at OFF. 3000 ON/OFF thermal conductance ratio was obtained at 4 K with helium.
Resumo:
In this work, a volumetric unit previously assembled by the research group was upgraded. This unit revamping was necessary due to the malfunction of the solenoid valves employed in the original experimental setup, which were not sealing the gas properly leading to erroneous adsorption equilibrium measurements. Therefore, the solenoid valves were substituted by manual ball valves. After the volumetric unit improvement its operation was validated. For this purpose, the adsorption equilibrium of carbon dioxide (CO2) at 323K and 0 - 20 bar was measured on two different activated carbon samples, in the of extrudates (ANG6) and of a honeycomb monolith (ACHM). The adsorption equilibrium results were compared with data previously measured by the research group, using a high-pressure microbalance from Rubotherm GmbH (Germany) – gravimetric. The results obtained using both apparatuses are coincident thus validating the good operation of the volumetric unit upgraded in this work. Furthermore, the adsorption equilibrium of CO2 at 303K and 0 - 10 bar on Metal-Organic Frameworks (MOFs) Cu-BTC and Fe-BTC was also studied. The CO2 adsorption equilibrium results for both MOFs were compared with the literature results showing good agreement, which confirms the good quality of the experimental results obtained in the new volumetric unit. Cu-BTC sample showed significantly higher CO2 adsorption capacity when compared with the Fe-BTC sample. The revamping of the volumetric unit included a new valve configuration in order to allow testing an alternative method for the measurement of adsorption equilibrium. This new method was employed to measure the adsorption equilibrium of CO2 on ANG6 and ACHM at 303, 323 and 353K within 0-10 bar. The good quality of the obtained experimental data was testified by comparison with data previously obtained by the research group in a gravimetric apparatus.
Resumo:
This work is divided into two distinct parts. The first part consists of the study of the metal organic framework UiO-66Zr, where the aim was to determine the force field that best describes the adsorption equilibrium properties of two different gases, methane and carbon dioxide. The other part of the work focuses on the study of the single wall carbon nanotube topology for ethane adsorption; the aim was to simplify as much as possible the solid-fluid force field model to increase the computational efficiency of the Monte Carlo simulations. The choice of both adsorbents relies on their potential use in adsorption processes, such as the capture and storage of carbon dioxide, natural gas storage, separation of components of biogas, and olefin/paraffin separations. The adsorption studies on the two porous materials were performed by molecular simulation using the grand canonical Monte Carlo (μ,V,T) method, over the temperature range of 298-343 K and pressure range 0.06-70 bar. The calibration curves of pressure and density as a function of chemical potential and temperature for the three adsorbates under study, were obtained Monte Carlo simulation in the canonical ensemble (N,V,T); polynomial fit and interpolation of the obtained data allowed to determine the pressure and gas density at any chemical potential. The adsorption equilibria of methane and carbon dioxide in UiO-66Zr were simulated and compared with the experimental data obtained by Jasmina H. Cavka et al. The results show that the best force field for both gases is a chargeless united-atom force field based on the TraPPE model. Using this validated force field it was possible to estimate the isosteric heats of adsorption and the Henry constants. In the Grand-Canonical Monte Carlo simulations of carbon nanotubes, we conclude that the fastest type of run is obtained with a force field that approximates the nanotube as a smooth cylinder; this approximation gives execution times that are 1.6 times faster than the typical atomistic runs.
Resumo:
In the field of energy, natural gas is an essential bridge to a clean, low carbon, renewable energy era. However, natural gas processing and transportation regulation require the removal of contaminant compounds such as carbon dioxide (CO2). Regarding clean air, the increasing atmospheric concentrations of greenhouse gases, specifically CO2, is of particular concern. Therefore, new costeffective, high performance technologies for carbon capture have been researched and the design of materials with the ability to efficiently separate CO2 from other gases is of vital importance.(...)
Resumo:
Shape memory alloys are characterized by the ability of recovering their initial shape after being deformed and by superelasticity. Since the discovery of these alloys, a new field of interest emerged not only for the scientific community but also to many industries. However, these alloys present poor machinability which constitute a constrain in the design of complex components for new applications. Thus, the demand for joining techniques able to join these alloys without compromising their properties became of great importance to enlarge the complexity of existing applications. Literature shows that these alloys are joined mainly using laser welding. In the present study, similar NiTi butt joints, were produced using TIG welding. The welds were performed in 1.5 mm thick plates across the rolling direction. A special fixture and gas assist device was designed and manufactured. Also a robot arm was adapted to accommodate the welding torch to assure the repeatability of the welding parameters. Welds were successfully achieved without macroscopic defects, such as pores and distortions. Very superficial oxidation was seen on the top surface due to insufficient shielding gas flow on the weld face. The welded joints were mechanically tested and structurally characterized. Testing methods were used to evaluate macro and microstructure, as well as the phase transformation temperatures, the mechanical single and cyclic behaviour and the shape recovery ability. Differential Scanning Calorimetry (DSC), Scanning Electron Microscopy (SEM), Energy Dispersive Spectroscopy (EDS), microhardness measurements were techniques also used to evaluate the welded joints. A depletion in Ni in the fusion zone was seen, as well as a shift in Ms temperature. For strain values of 4% the accumulated irrecoverable strain was of about 30% and increased with the strain imposed during cycling. Nevertheless, a complete recovery of initial shape was observed when testing the shape memory effect on a dedicated device that introduces a deformation of 6.7%. That is, the welding procedure does not remove the ability of the specimens to recover their initial shape.
Resumo:
Pavements require maintenance in order to provide good service levels during their life period. Because of the significant costs of this operation and the importance of a proper planning, a pavement evaluation methodology, named Pavement Condition Index (PCI), was created by the U.S. Army Corps of Engineers. This methodology allows for the evaluation of the pavement condition along the life period, generally yearly, with minimum costs and, in this way, it is possible to plan the maintenance action and to adopt adequate measures, minimising the rehabilitation costs. The PCI methodology provides an evaluation based on visual inspection, namely on the distresses observed on the pavement. This condition index of the pavement is classified from 0 to 100, where 0 it is the worst possible condition and 100 the best possible condition. This methodology of pavement assessment represents a significant tool for management methods such as airport pavement management system (APMS) and life-cycle costs analysis (LCCA). Nevertheless, it has some limitations which can jeopardize the correct evaluation of the pavement behavior. Therefore the objective of this dissertation is to help reducing its limitations and make it easier and faster to use. Thus, an automated process of PCI calculation was developed, avoiding the abaci consultation, and consequently, minimizing the human error. To facilitate also the visual inspection a Tablet application was developed to replace the common inspection data sheet and thus making the survey easier to be undertaken. Following, an airport pavement condition was study accordingly with the methodology described at Standard Test Method for Airport Pavement Condition Index Surveys D5340, 2011 where its original condition level is compared with the condition level after iterate possible erroneous considered distresses as well as possible rehabilitations. Afterwards, the results obtained were analyzed and the main conclusions presented together with some future developments.
Resumo:
25th International Cryogenic Engineering Conference and the International Cryogenic Materials Conference in 2014, ICEC 25–ICMC 2014
Resumo:
Equity research report
Resumo:
Equity research report
Resumo:
Objetivo Avaliar a equivalência semântica e a consistência interna da Game Addiction Scale (GAS): versão em português. Métodos O procedimento constituiu-se das seguintes etapas: a) revisão da literatura; b) tradução do instrumento original; c) retrotradução; d) revisão técnica e avaliação da compreensão verbal, realizada por profissionais da área da saúde; e) avaliação da compreensão verbal do instrumento, por uma amostra de estudantes; f) análise da consistência interna (alfa de Cronbach). Os participantes, com exceção dos especialistas, foram selecionados por conveniência. A participação dos sujeitos foi diferente em cada fase: tradutores (n = 2), retrotradução (n = 1), revisão técnica (n = 2), especialistas (n = 12), pré-teste com estudantes universitários (n = 40) e mensuração com estudantes universitários (n = 100). Resultados Poucas alterações semânticas de expressões e termos foram realizadas para adaptar-se à cultura-alvo. O nível de compreensão verbal dos participantes (especialistas e estudantes) foi superior a 90% e a análise do alfa de Cronbach correspondeu a 0,92 para todo o instrumento. Conclusão A Escala de Dependência de Jogos Eletrônicos (ESDEJE) foi submetida a tradução e adaptação para o idioma português (do Brasil), apresentando consistência interna adequada. Ademais, sugere-se a realização do processo de validação referente à equivalência de mensuração e reprodutibilidade do instrumento.
Resumo:
OBJECTIVE: To compare gas exchange at rest and during exercise in patients with chronic Chagas' heart disease grouped according to the Los Andes clinical/hemodynamic classification. METHODS: We studied 15 healthy volunteers and 52 patients grouped according to the Los Andes clinical/hemodynamic classification as follows: 17 patients in group IA (normal electrocardiogram/echocardiogram), 9 patients in group IB (normal electrocardiogram and abnormal echocardiogram), 14 patients in group II (abnormal electrocardiogram/echocardiogram, without congestive heart failure), and 12 patients in group III (abnormal electrocardiogram/echocardiogram with congestive heart failure). The following variables were analyzed: oxygen consumption (V O2), carbon dioxide production (V CO2), gas exchange rate (R), inspiratory current volume (V IC), expiratory current volume (V EC), respiratory frequency, minute volume (V E), heart rate (HR), maximum load, O2 pulse, and ventilatory anaerobic threshold (AT). RESULTS: When compared with the healthy group, patients in groups II and III showed significant changes in the following variables: V O2peak, V CO2peak, V ICpeak, V ECpeak, E, HR, and maximum load. Group IA showed significantly better results for these same variables as compared with group III. CONCLUSION: The functional capacity of patients in the initial phase of chronic Chagas' heart disease is higher than that of patients in an advanced phase and shows a decrease that follows the loss in cardiac-hemodynamic performance.