912 resultados para Optimal power flow


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Power allocation is studied for fixed-rate transmission over block-fading channels with arbitrary continuous fading distributions and perfect transmitter and receiver channel state information. Both short- and long-term power constraints for arbitrary input distributions are considered. Optimal power allocation schemes are shown to be direct applications of previous results in the literature. It is shown that the short- and long-term outage exponents for arbitrary input distributions are related through a simple formula. The formula is useful to predict when the delay-limited capacity is positive. Furthermore, this characterization is useful for the design of efficient coding schemes for this relevant channel model. © 2010 IEEE.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A novel hybrid data-driven approach is developed for forecasting power system parameters with the goal of increasing the efficiency of short-term forecasting studies for non-stationary time-series. The proposed approach is based on mode decomposition and a feature analysis of initial retrospective data using the Hilbert-Huang transform and machine learning algorithms. The random forests and gradient boosting trees learning techniques were examined. The decision tree techniques were used to rank the importance of variables employed in the forecasting models. The Mean Decrease Gini index is employed as an impurity function. The resulting hybrid forecasting models employ the radial basis function neural network and support vector regression. A part from introduction and references the paper is organized as follows. The second section presents the background and the review of several approaches for short-term forecasting of power system parameters. In the third section a hybrid machine learningbased algorithm using Hilbert-Huang transform is developed for short-term forecasting of power system parameters. Fourth section describes the decision tree learning algorithms used for the issue of variables importance. Finally in section six the experimental results in the following electric power problems are presented: active power flow forecasting, electricity price forecasting and for the wind speed and direction forecasting.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper proposes new direct power control (DPC) strategies for three-phase DC/AC converters with improved dynamic response and steady-state performance. As with an electrical machine, source and converter flux which equal the integration of the respective source and converter voltage are used to define active and reactive power flow. Optimization of the look-up-table used in conventional DPC is outlined first, to improve the power control and reduce the current distortion. Then constant switching frequency DPC is developed where the required converter voltage vector within a fixed half switching period is calculated directly from the active and reactive power errors. Detailed angle compensation due to the finite sampling frequency and the use of integral controller to further improve the power control accuracy, are described. Both simulation and experimental results are used to compare conventional DPC and vector control, and to demonstrate the effectiveness and robustness of the proposed control strategies during active and reactive power steps, and line inductance variations.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The increasing penetration of wind generation on the Island of Ireland has been accompanied by close investigation of low-frequency pulsations contained within active power flow. A primary concern is excitation of low-frequency oscillation modes already present on the system, particularly the 0.75 Hz mode as a consequence of interconnection between the Northern and Southern power system networks. In order to determine whether the prevalence of wind generation has a negative effect (excites modes) or positive impact (damping of modes) on the power system, oscillations must be measured and characterised. Using time – frequency methods, this paper presents work that has been conducted to extract features from low-frequency active power pulsations to determine the composition of oscillatory modes which may impact on dynamic stability. The paper proposes a combined wavelet-Prony method to extract modal components and determine damping factors. The method is exemplified using real data obtained from wind farm measurements.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A wireless relay network with one source, one relay and one destination is considered, where nodes communicate via N orthogonal channels. We develop optimal power allocation strategies at both the source and relay for maximizing the overall source-destination capacity under individual power constraints at the source and relay. Some properties of the optimal solution are studied. © 2012 IEEE.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

It is acknowledged that wind power is a stochastic energy source compared to hydroelectric generation which is easily scheduled. In this paper a scheme for coordinating wind power plant and hydroelectric power plant is presented by using PMUs to measure and control the state of wind and hydro power plants. Hydroelectric generation is proposed as a method of energy reserve and compensation in the context of wind power fluctuation in order to avoid full or partial curtailment of wind generation to benefit wind providers. The feasibility of this proposed scheme is investigated by power flow calculation and stability analysis using the IEEE 30-bus power system model.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The increasing penetration of wind generation on the Island of Ireland has been accompanied by close investigation of low-frequency periodic pulsations contained within the active power flow from different wind farms. A primary concern is excitation of existing low-frequency oscillation modes already present on the system, particularly the 0.75 Hz mode as a consequence of the interconnected Northern and Southern power system networks. Recently grid code requirements on the Northern Ireland power system have been updated stipulating that wind farms connected after 2005 must be able to control the magnitude of oscillations in the range of 0.25 - 1.75 Hz to within 1% of the wind farm's registered output. In order to determine whether wind farm low-frequency oscillations have a negative effect (excite other modes) or possibly a positive impact (damping of existing modes) on the power system, the oscillations at the point of connection must be measured and characterised. Using time - frequency methods, research presented in this paper has been conducted to extract signal features from measured low-frequency active power pulsations produced by wind farms to determine the effective composition of possible oscillatory modes which may have a detrimental effect on system dynamic stability. The paper proposes a combined wavelet-Prony method to extract modal components and determine damping factors. The method is exemplified using real data obtained from wind farm measurements.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The impact of power fluctuations arising from fixed-speed wind turbines on the magnitude and frequency of inter-area oscillations has been investigated. The authors introduced data acquisition equipment to record the power flow on the interconnector between the Northern Ireland and Republic of Ireland systems. Through monitoring the interconnector oscillation using a fast Fourier transform, it was possible to determine the magnitude and frequency of the inter-area oscillation between the two systems. The impact of tower shadow on the output power from a wind farm was analysed using data recorded on site. A case study investigates the effect on the system of the removal of a large fixed-speed wind farm. Conclusions are drawn on the impact that conventional generation and the output from fixed-speed wind farms have on the stability of the Irish power system.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We consider a wireless relay network with one source, one relay and one destination, where communications between nodes are preformed over N orthogonal channels. This, for example, is the case when orthogonal frequency division multiplexing is employed for data communications. Since the power available at the source and relay is limited, we study optimal power allocation strategies at the source and relay in order to maximize the overall source-destination capacity. Depending on the availability of the channel state information at both the source and relay or only at the relay, power allocation is performed at both the source and relay or only at the relay. Considering different setups for the problem, various optimization problems are formulated and solved. Some properties of the optimal solution are also proved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The small signal stability of interconnected power systems is one of the important aspects that need to be investigated since the oscillations caused by this kind of instability have caused many incidents. With the increasing penetration of wind power in the power system, particularly doubly fed induction generator (DFIG), the impact on the power system small signal stability performance should be fully investigated. Because the DFIG wind turbine integration is through a fast action converter and associated control, it does not inherently participate in the electromechanical small signal oscillation. However, it influences the small signal stability by impacting active power flow paths in the network and replacing synchronous generators that have power system stabilizer (PSS). In this paper, the IEEE 39 bus test system has been used in the analysis. Furthermore, four study cases and several operation scenarios have been conducted and analysed. The selective eigenvalue Arnoldi/lanczos's method is used to obtain the system eigenvalue in the range of frequency from 0.2 Hz to 2 Hz which is related to electromechanical oscillations. Results show that the integration of DFIG wind turbines in a system during several study cases and operation scenarios give different influence on small signal stability performance.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A new approach to determine the local boundary of voltage stability region in a cut-set power space (CVSR) is presented. Power flow tracing is first used to determine the generator-load pair most sensitive to each branch in the interface. The generator-load pairs are then used to realize accurate small disturbances by controlling the branch power flow in increasing and decreasing directions to obtain new equilibrium points around the initial equilibrium point. And, continuous power flow is used starting from such new points to get the corresponding critical points around the initial critical point on the CVSR boundary. Then a hyperplane cross the initial critical point can be calculated by solving a set of linear algebraic equations. Finally, the presented method is validated by some systems, including New England 39-bus system, IEEE 118-bus system, and EPRI-1000 bus system. It can be revealed that the method is computationally more efficient and has less approximation error. It provides a useful approach for power system online voltage stability monitoring and assessment. This work is supported by National Natural Science Foundation of China (No. 50707019), Special Fund of the National Basic Research Program of China (No. 2009CB219701), Foundation for the Author of National Excellent Doctoral Dissertation of PR China (No. 200439), Tianjin Municipal Science and Technology Development Program (No. 09JCZDJC25000), National Major Project of Scientific and Technical Supporting Programs of China During the 11th Five-year Plan Period (No. 2006BAJ03A06). ©2009 State Grid Electric Power Research Institute Press.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Peak power consumption is the first order design constraint of data centers. Though peak power consumption is rarely, if ever, observed, the entire data center facility must prepare for it, leading to inefficient usage of its resources. The most prominent way for addressing this issue is to limit the power consumption of the data center IT facility far below its theoretical peak value. Many approaches have been proposed to achieve that, based on the same small set of enforcement mechanisms, but there has been no corresponding work on systematically examining the advantages and disadvantages of each such mechanism. In the absence of such a study,it is unclear what is the optimal mechanism for a given computing environment, which can lead to unnecessarily poor performance if an inappropriate scheme is used. This paper fills this gap by comparing for the first time five widely used power capping mechanisms under the same hardware/software setting. We also explore possible alternative power capping mechanisms beyond what has been previously proposed and evaluate them under the same setup. We systematically analyze the strengths and weaknesses of each mechanism, in terms of energy efficiency, overhead, and predictable behavior. We show how these mechanisms can be combined in order to implement an optimal power capping mechanism which reduces the slow down compared to the most widely used mechanism by up to 88%. Our results provide interesting insights regarding the different trade-offs of power capping techniques, which will be useful for designing and implementing highly efficient power capping in the future. 

Relevância:

90.00% 90.00%

Publicador:

Resumo:

O presente trabalho visa discutir a relação entre a abordagem Orff-Schulwerk e o desenvolvimento do ‘Eu Musical’ em contexto de Educação Musical no 2.º Ciclo do Ensino Básico genérico português. Na tentativa de verificar, analisar e tentar compreender esta relação, o processo empírico fundamentou-se na Flow Theory, desenvolvida por Mihaly Csikszentmihalyi. O enquadramento teórico conduziu à elaboração do ‘Modelo Multidimensional de Eu Musical’ (‘MoMEuM’), o qual, partindo da abordagem Orff-Schulwerk, procurou bases epistemológicas na Flow Theory, nas vertentes Cultural, Social e Positiva da Psicologia, bem como no Embodiment. A componente empírica do estudo teve como base metodológica a investigação-ação. Nesse sentido, o professor-investigador acompanhou, de forma longitudinal, o percurso de 50 alunos no referido contexto e procurou verificar, através do FIMA - Flow Indicators in Musical Activity, a vivência de ‘experiências ótimas/estados de fluxo’ em atividades/estratégias pedagógicomusicais baseadas na abordagem Orff-Schulwerk e, por conseguinte, no desenvolvimento do ‘Eu Musical’. A análise e interpretação de dados sugere que a abordagem Orff-Schulwerk promove a ocorrência de ‘experiências ótimas/estados de fluxo’ e, no quadro do presente estudo, impulsiona o desenvolvimento do ‘Eu Musical’.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Energy resource scheduling becomes increasingly important, as the use of distributed resources is intensified and massive gridable vehicle use is envisaged. The present paper proposes a methodology for dayahead energy resource scheduling for smart grids considering the intensive use of distributed generation and of gridable vehicles, usually referred as Vehicle- o-Grid (V2G). This method considers that the energy resources are managed by a Virtual Power Player (VPP) which established contracts with V2G owners. It takes into account these contracts, the user´s requirements subjected to the VPP, and several discharge price steps. Full AC power flow calculation included in the model allows taking into account network constraints. The influence of the successive day requirements on the day-ahead optimal solution is discussed and considered in the proposed model. A case study with a 33 bus distribution network and V2G is used to illustrate the good performance of the proposed method.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper presents a methodology to address reactive power compensation using Evolutionary Particle Swarm Optimization (EPSO) technique programmed in the MATLAB environment. The main objective is to find the best operation point minimizing power losses with reactive power compensation, subjected to all operational constraints, namely full AC power flow equations, active and reactive power generation constraints. The methodology has been tested with the IEEE 14 bus test system demonstrating the ability and effectiveness of the proposed approach to handle the reactive power compensation problem.