931 resultados para Nonblind receiver


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The accuracy of multidetector computed tomographic (CT) angiography involving 64 detectors has not been well established. Methods: We conducted a multicenter study to examine the accuracy of 64-row, 0.5-mm multidetector CT angiography as compared with conventional coronary angiography in patients with suspected coronary artery disease. Nine centers enrolled patients who underwent calcium scoring and multidetector CT angiography before conventional coronary angiography. In 291 patients with calcium scores of 600 or less, segments 1.5 mm or more in diameter were analyzed by means of CT and conventional angiography at independent core laboratories. Stenoses of 50% or more were considered obstructive. The area under the receiver-operating-characteristic curve (AUC) was used to evaluate diagnostic accuracy relative to that of conventional angiography and subsequent revascularization status, whereas disease severity was assessed with the use of the modified Duke Coronary Artery Disease Index. Results: A total of 56% of patients had obstructive coronary artery disease. The patient-based diagnostic accuracy of quantitative CT angiography for detecting or ruling out stenoses of 50% or more according to conventional angiography revealed an AUC of 0.93 (95% confidence interval [CI], 0.90 to 0.96), with a sensitivity of 85% (95% CI, 79 to 90), a specificity of 90% (95% CI, 83 to 94), a positive predictive value of 91% (95% CI, 86 to 95), and a negative predictive value of 83% (95% CI, 75 to 89). CT angiography was similar to conventional angiography in its ability to identify patients who subsequently underwent revascularization: the AUC was 0.84 (95% CI, 0.79 to 0.88) for multidetector CT angiography and 0.82 (95% CI, 0.77 to 0.86) for conventional angiography. A per-vessel analysis of 866 vessels yielded an AUC of 0.91 (95% CI, 0.88 to 0.93). Disease severity ascertained by CT and conventional angiography was well correlated (r=0.81; 95% CI, 0.76 to 0.84). Two patients had important reactions to contrast medium after CT angiography. Conclusions: Multidetector CT angiography accurately identifies the presence and severity of obstructive coronary artery disease and subsequent revascularization in symptomatic patients. The negative and positive predictive values indicate that multidetector CT angiography cannot replace conventional coronary angiography at present. (ClinicalTrials.gov number, NCT00738218.).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Unauthorized accesses to digital contents are serious threats to international security and informatics. We propose an offline oblivious data distribution framework that preserves the sender's security and the receiver's privacy using tamper-proof smart cards. This framework provides persistent content protections from digital piracy and promises private content consumption.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the influence of cross-sectional arc calcification on the diagnostic accuracy of computed tomography (CT) angiography compared with conventional coronary angiography for the detection of obstructive coronary artery disease (CAD). Materials and Methods: Institutional Review Board approval and written informed consent were obtained from all centers and participants for this HIPAA-compliant study. Overall, 4511 segments from 371 symptomatic patients (279 men, 92 women; median age, 61 years [interquartile range, 53-67 years]) with clinical suspicion of CAD from the CORE-64 multi-center study were included in the analysis. Two independent blinded observers evaluated the percentage of diameter stenosis and the circumferential extent of calcium (arc calcium). The accuracy of quantitative multidetector CT angiography to depict substantial (>50%) stenoses was assessed by using quantitative coronary angiography (QCA). Cross-sectional arc calcium was rated on a segment level as follows: noncalcified or mild (<90 degrees), moderate (90 degrees-180 degrees), or severe (>180 degrees) calcification. Univariable and multivariable logistic regression, receiver operation characteristic curve, and clustering methods were used for statistical analyses. Results: A total of 1099 segments had mild calcification, 503 had moderate calcification, 338 had severe calcification, and 2571 segments were noncalcified. Calcified segments were highly associated (P < .001) with disagreement between CTA and QCA in multivariable analysis after controlling for sex, age, heart rate, and image quality. The prevalence of CAD was 5.4% in noncalcified segments, 15.0% in mildly calcified segments, 27.0% in moderately calcified segments, and 43.0% in severely calcified segments. A significant difference was found in area under the receiver operating characteristic curves (noncalcified: 0.86, mildly calcified: 0.85, moderately calcified: 0.82, severely calcified: 0.81; P < .05). Conclusion: In a symptomatic patient population, segment-based coronary artery calcification significantly decreased agreement between multidetector CT angiography and QCA to detect a coronary stenosis of at least 50%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Context: A better means to accurately identify malignant thyroid nodules and to distinguish them from benign tumors is needed. We previously identified markers for detecting thyroid malignancy, with sensitivity estimated at or close to 100%. One lingering problem with these markers was that false positives occurred with Hurthle cell adenomas (HCA) which lowered test specificity. Methods: To locate accurate diagnostic markers, we profiled in depth the transcripts of a HCA and a Hurthle cell carcinoma (HCC). From 1146 differentially expressed genes, 18 transcripts specifically expressed in HCA were tested by quantitative PCR in a wide range of thyroid tumors (n = 76). Sensibility and specificity were calculated using receiver operating characteristic (ROC). Selected markers were further validated in an independent set of thyroid tumors (n = 82) by immunohistochemistry. To define the panel that would yield best diagnostic accuracy, these markers were tested in combination with our previous identified markers. Results: Seventeen of the 18 genes showed statistical significance based on a mean relative level of expression (P < 0.05). KLK1 (sensitivity = 0.97) and PVALB (sensitivity = 0.94) were the best candidate markers. The combination of PVALB and C1orf24 increased specificity to > 97% and maintained sensitivity for detection of carcinoma. Conclusion: We identified tumor markers that can be used in combination for a more accurate preoperative diagnosis of thyroid nodules and for postoperative diagnosis of thyroid carcinoma in tumor sections. This improved test would help physicians rapidly focus treatment on true malignancies and avoid unnecessary treatment of benign tumors, simultaneously improving medical care and reducing costs. (J Clin Endocrinol Metab 96: E151-E160, 2011)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction. Hepatic steatosis due to non-alcoholic fatty liver disease is associated with obesity, dyslipidemia, insulin resistance, and type 2 diabetes. The Finnish Diabetes Risk Score (FINDRISC) is a prognostic screening tool to detect people at risk for type 2 diabetes without the use of any blood test. The objective of this study was to evaluate whether FINDRISC can also be used to screen for the presence of hepatic steatosis. Patients and methods. Steatosis was determined by ultrasound. The study sample consisted of 821 non-diabetic subjects without previous hepatic disease; 81% were men (mean age 45 +/- 9 years) and 19% women (mean age 41 +/- 10 years). Results. Steatosis was present in 44% of men and 10% of women. The odds ratio for one unit increase in the FINDRISC associated with the risk of steatosis was 1.30 (95% CI 1.25-1.35), similar for men and women. The area under the receiver operating characteristics curve for steatosis was 0.80 (95% CI 0.77-0.83); 0.80 in men (95% CI 0.77-0.83) and 0.83 (95% CI 0.73-0.93) in women. Conclusions. Our data suggest that the FINDRISC could be a useful primary screening tool for the presence of steatosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Real time myocardial contrast echocardiography (RTMCE) is an emerging imaging modality for assessing myocardial perfusion that allows for noninvasive quantification of regional myocardial blood flow (MBF). Aim: We sought to assess the value of qualitative analysis of myocardial perfusion and quantitative assessment of myocardial blood flow (MBF) by RTMCE for predicting regional function recovery in patients with ischemic heart disease who underwent coronary artery bypass grafting (CABG). Methods: Twenty-four patients with coronary disease and left ventricular systolic dysfunction (ejection fraction < 45%) underwent RTMCE before and 3 months after CABG. RTMCE was performed using continuous intravenous infusion of commercially available contrast agent with low mechanical index power modulation imaging. Viability was defined by qualitative assessment of myocardial perfusion as homogenous opacification at rest in >= 2 segments of anterior or >= 1 segment of posterior territory. Viability by quantitative assessment of MBF was determined by receiver-operating characteristics curve analysis. Results: Regional function recovery was observed in 74% of territories considered viable by qualitative analysis of myocardial perfusion and 40% of nonviable (P = 0.03). Sensitivity, specificity, positive and negative predictive values of qualitative RTMCE for detecting regional function recovery were 74%, 60%, 77%, and 56%, respectively. Cutoff value of MBF for predicting regional function recovery was 1.76 (AUC = 0.77; 95% CI = 0.62-0.92). MBF obtained by RTMCE had sensitivity of 91%, specificity of 50%, positive predictive value of 75%, and negative predictive value of 78%. Conclusion: Qualitative and quantitative RTMCE provide good accuracy for predicting regional function recovery after CABG. Determination of MBF increases the sensitivity for detecting hibernating myocardium. (Echocardiography 2011;28:342-349).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Left ventricular hypertrophy is an important predictor of cardiovascular risk and sudden death. This study explored the ability of four obesity indexes (body mass index, waist circumference, waist-hip ratio and waist-stature ratio) to identify left ventricular hypertrophy. A sample of the general population (n=682; 43.5% men) was surveyed to assess cardiovascular risk factors. Biochemical, anthropometric and blood pressure values were obtained in a clinic visit according to standard methods. Left ventricular mass was obtained from transthoracic echocardiogram. Left ventricular hypertrophy was defined using population-specific cutoff values for left ventricular mass indexed to height(2.7). The waist-stature ratio showed the strongest positive association with left ventricular mass. This correlation was stronger in women, even after controlling for age and systolic blood pressure. By multivariate analysis, the main predictors of left ventricular hypertrophy were waist-stature ratio (23%), systolic blood pressure (9%) and age (2%) in men, and waist-stature ratio (40%), age (6%) and systolic blood pressure (2%) in women. Receiver-operating characteristic curves showed the optimal cutoff values of the different anthropometric indexes associated with left ventricular hypertrophy. The waist-stature ratio was a significantly better predictor than the other indexes (except for the waist-hip ratio), independent of gender. It is noteworthy that a waist-stature ratio cutoff of 0.56 showed the highest combined sensitivity and specificity to detect left ventricular hypertrophy. Abdominal obesity identified by waist-stature ratio instead of overall obesity identified by body mass index is the simplest and best obesity index for assessing the risk of left ventricular hypertrophy, is a better predictor in women and has an optimal cutoff ratio of 0.56. Hypertension Research (2010) 33, 83-87; doi: 10.1038/hr.2009.188; published online 13 November 2009

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A risk score model was developed based in a population of 1,224 individuals from the general population without known diabetes aging 35 years or more from an urban Brazilian population sample in order to select individuals who should be screened in subsequent testing and improve the efficacy of public health assurance. External validation was performed in a second, independent, population from a different city ascertained through a similar epidemiological protocol. The risk score was developed by multiple logistic regression and model performance and cutoff values were derived from a receiver operating characteristic curve. Model`s capacity of predicting fasting blood glucose levels was tested analyzing data from a 5-year follow-up protocol conducted in the general population. Items independently and significantly associated with diabetes were age, BMI and known hypertension. Sensitivity, specificity and proportion of further testing necessary for the best cutoff value were 75.9, 66.9 and 37.2%, respectively. External validation confirmed the model`s adequacy (AUC equal to 0.72). Finally, model score was also capable of predicting fasting blood glucose progression in non-diabetic individuals in a 5-year follow-up period. In conclusion, this simple diabetes risk score was able to identify individuals with an increased likelihood of having diabetes and it can be used to stratify subpopulations in which performing of subsequent tests is necessary and probably cost-effective.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: International nutritional screening tools are recommended for screening hospitalized patients for nutritional risk, but no tool has been specifically evaluated in the Brazilian population. The aim of this study was to identify the most appropriate nutritional screening tool for predicting unfavorable clinical outcomes in patients admitted to a Brazilian public university hospital. Methods: The Nutritional Risk Screening 2002 (NRS 2002), Mini-Nutritional Assessment-Short Form (MNA-SF), and Malnutrition Universal Screening Tool (MUST) were administered to 705 patients within 48 h of hospital admission. Tool performance in predicting complications, very long length of hospital stay (LOS), and death was analyzed using receiver operating characteristic curves. Results: NRS 2002, MUST, and MNA-SF identified nutritional risk in 27.9%, 39.6%, and 73.2% of the patients, respectively. NRS 2002 (complications: 0.6531; very long LOS: 0.6508; death: 0.7948) and MNA-SF(complications: 0.6495; very long LOS: 0.6197; death: 0.7583) had largest areas under the ROC curve compared to MUST (complications: 0.6036; very long LOS: 0.6109; death: 0.6363). For elderly patients, NRS 2002 was not significantly different than MNA-SF (P>0.05) for predicting outcomes. Conclusion: Considering current criteria for nutritional risk, NRS 2002 and MNA-SF have similar performance to predict outcomes but NRS 2002 seems to provide a best yield. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To compare the ability of Subjective assessment of optic nerve head (ONH) and retinal nerve fiber layer (RNFL) by general ophthalmologists and by a glaucoma expert with objective measurements by optical coherence tomography (Stratus OCT, Carl Zeiss Meditec Inc), confocal scanning laser ophthalmoscope (HRT III; Heidelberg Engineering, Heidelberg. Germany), and scanning laser polarimetry (GDx enhanced corneal compensation; Carl Zeiss Meditec Inc, Dublin, CA) in discriminating glaucomatous and normal eyes. Methods: Sixty-one glaucomatous and 57 normal eyes or 118 subjects Were included in the study. Three independent general ophthalmologists and I glaucoma expert evaluated ONH stereo-photographs. Receiver operating characteristic curves were constructed for each imaging technique and sensitivity at fixed specificity was estimated. Comparisons or areas under these curves (aROCs) and agreement (k) were determined between stereophoto grading and best parameter from each technique. Results: Best parameter from each technique showed larger aROC (Stratus OCT RNFL 0.92; Stratus OCT ONH vertical integrated area = 0.86; Stratus OCT macular thickness = 0.82; GDx enhanced corneal compensation = 0.91, HRT3 global cup-to-disc ratio = 0.83; HRT3 glaucoma probability score numeric area score 0.83) compared with stereophotograph grading by general ophthalmologists (0.80) in separating glaucomatous and normal eyes. Glaucoma expert stereophoto grading provided equal or larger aROC (0.92) than best parameter of each computerized imaging device. Stereophoto evaluated by a glaucoma expert showed better agreement with best parameter of each quantitative imaging technique in classifying eyes either as glaucomatous or normal compared with stereophoto grading by general ophthalmologists, The combination Of Subjective assessment of the optic disc by general ophthalmologists with RNFL objective parameters improved identification of glaucoma patients in a larger proportion than the combination of these objective parameters with Subjective assessment of the optic disc by a glaucoma expert (29.5% vs. 19.7%, respectively). Conclusions: Diagnostic ability of all imaging techniques showed better performance than subjective assessment of the ONH by general ophthalmologists, but not by It glaucoma expert, Objective RNFL measurements may provide improvement in glaucoma detection when combined with subjective assessment of the optic disc by general ophthalmologists or by a glaucoma expert.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To compare the ability of Fourier-domain (FD) optical coherence tomography (3D OCT-1000; Top, con, Tokyo, Japan) and time domain (TD) OCT (Stratus; Carl Zeiss Meditec Inc, Dublin, California, USA) to detect axonal loss in eyes with band atrophy (BA) of the optic nerve. DESIGN: Cross-sectional study. METHODS: Thirty-six eyes from 36 patients with BA and temporal visual field (VF) defect from chiasmal compression and 36 normal eyes were studied. Subjects were submitted to standard automated perimetry and macular and retinal nerve fiber layer (RNFL) measurements were taken using 3D OCT-1000 and Stratus OCT. Receiver operating characteristic (ROC) curves were calculated for each parameter. Spearman correlation coefficients were obtained to evaluate the relationship between RNFL and macular thickness parameters and severity of VF loss. Measurements from the two devices were compared. RESULTS: Regardless of OCT device, all RNFL and macular thickness parameters were significantly lower in eyes with BA compared with normal eyes, but no statistically significant difference was found with regard to the area under the ROC curve. Structure-function relationships were also similar for the two devices. In both groups, RNFL and macular thickness measurements were generally and in some cases significantly smaller with 3D OCT-1000 than with Stratus OCT. CONCLUSIONS: The introduction of FD technology did not lead to better discrimination ability for detecting BA of the optic nerve compared with TD technology when using the software currently provided by the manufacturer. 3D OCT-1000 FD OCT RNFL and macular measurements were generally smaller than TD Stratus OCT measurements. Investigators should be aware of this fact when comparing measurements obtained with these two devices. (Am J Oplathalmol 2009;147: 56-63. (c) 2009 by Elsevier Inc. All rights reserved.)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim To compare the ability of scanning laser polarimeter (SLP) with variable corneal compensation (GDx VCC) and optical coherence tomograph (Stratus OCT) to discriminate between eyes with band atrophy (BA) of the optic nerve and healthy eyes. Methods The study included 37 eyes with BA and temporal visual field (VF) defects from chiasmal compression, and 29 normal eyes. Subjects underwent standard automated perimetry (SAP) and retinal nerve fibre layer (RNFL) scans using GDx VCC and Stratus OCT. The severity of the VF defects was evaluated by the temporal mean defect (TMD), calculated as the average of 22 values of the temporal total deviation plot on SAP. Receiver operating characteristic (ROC) curves were calculated. Pearson`s correlation coefficients were used to evaluate the relationship between RNFL thickness parameters and the TMD. Results No significant difference was found between the ROC curves areas (AUCs) for the GDx VCC and Stratus OCT with regard to average RNFL thickness (0.98 and 0.99, respectively) and the superior (0.94; 0.95), inferior (0.96; 0.97), and nasal (0.92; 0.96) quadrants. However, the AUC in the temporal quadrant (0.77) was significantly smaller (P < 0.001) with GDx VCC than with Stratus OCT (0.98). Lower TMD values were associated with smaller RNFL thickness in most parameters from both equipments. Conclusion Adding VCC resulted in improved performance in SLP when evaluating eyes with BA, and both technologies are sensitive in detecting average, superior, inferior, and nasal quadrant RNFL loss. However, GDx VCC still poorly discriminates RNFL loss in the temporal quadrant when compared with Stratus OCT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: To compare cervical length (CL) at 18-21 and 22-25 weeks` gestation in twin pregnancies in prediction of spontaneous preterm delivery and to examine cervical shortening. Methods: Retrospective cohort study of CL measured at 18-21 and 22-25 weeks` gestation in twin pregnancies. Results: Receiver operating characteristics (ROC) curve revealed area of 0.64 (95% CI 0.53-0.75) and 0.80 (95% CI 0.72-0.88) for measurements at 18-21 and 22-25 weeks, respectively (P <= 0.001). Sensitivities of 33.3% and 23% and negative predicting value (NPV) of 97.3% and 86.8% for delivery at <28 and <34 weeks gestation were reached for measurements at 18-21 weeks. Sensitivities of 71.4% and 38.2% and NPV of 99.1% and 91.4% for delivery at <28 and <34 weeks` gestation were reached for measurements at 22-25 weeks. Cervical length shortening analysis showed an area under ROC curve of 0.81 (95% CI 0.73-0.89) and best cut-off was at >= 2 mm/week. Sensitivities of 80% and 60.8% and NPV of 98.9% and 90.6% for delivery at <28 and <34 weeks gestation were reached. Conclusions: In twin gestations, assessment of CL at 22-25 weeks is better than assessment at 18-21 weeks to predict preterm delivery before 34 weeks. Cervical shortening at a rate of >= 2 mm/weeks between 18 and 25 weeks gestation was a good predictor of spontaneous preterm birth in this high-risk population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Follistatin is an activin-binding protein produced by several tissues, including endometrium and endometriotic implants. We aimed to quantify follistatin in patients with ovarian endometriosis and investigate its value as a diagnostic marker. Women undergoing laparoscopic excision of ovarian endometrioma (n = 52) or other benign ovarian cysts (n = 52) were studied, plus women with non-ovarian endometriosis (n = 11) and healthy controls (n = 27). Serum was collected from all subjects, and peritoneal and cystic fluid from a subset with endometrioma. Follistatin was measured by enzyme-linked immunosorbent assay. The diagnostic accuracy of follistatin to detect endometrioma was evaluated by receiver operating characteristic (ROC) curve and compared with cancer antigen (CA)-125. Serum follistatin was increased in women with ovarian endometrioma (2080 +/- 94 pg/ml) compared with controls (545 +/- 49 pg/ml, P < 0.001), other benign ovarian cysts (795 +/- 60 pg/ml, P < 0.001) or non-ovarian endometriosis (1271 +/- 115 pg/ml, P < 0.001). Cystic fluid showed a higher concentration of follistatin (9850 +/- 4461 pg/ml) than peritoneal fluid (1885 +/- 261 pg/ml, P < 0.001) and serum (P < 0.001). Follistatin levels detected 48/52 cases of endometrioma (92% sensitivity) at 1433 pg/ml cut-off, corresponding to 92% specificity. CA-125 detected only 44% of endometriomas with 90% specificity. ROC curve comparison showed follistatin was more accurate than CA-125 to discriminate women with endometrioma either from controls or women with other benign ovarian cysts (P < 0.0001). Serum follistatin is increased in women with endometriosis and allows clear distinction between endometrioma and other benign ovarian cysts. Follistatin has the sensitivity and specificity to become a useful clinical marker of ovarian endometrioma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Direct Assessment of Functional Status-Revised (DAFS-R) is an instrument developed to objectively measure functional capacities required for independent living. The objective of this study was to translate and culturally adapt the DAFS-R for Brazilian Portuguese (DAFS-BR) and to evaluate its reliability and validity. The DAFS-BR was administered to 89 older patients classified previously as normal controls, mild cognitive impairment (MCI) and Alzheimer`s disease (AD). The results indicated good internal consistency (Cronbach`s alpha = 0.78) in the total sample. The DAFS-BR showed high interobserver reliability (0.996; p < .001) as well as test-retest stability over 1-week interval (0.995; p < .001). Correlation between the DAFS-BR total score and the Informant Questionnaire on Cognitive Decline in the Elderly (IQCODE) was moderate and significant (r = -.65, p < .001) in the total sample, whereas it did not reach statistical significance within each diagnostic group. Receiver operating characteristic curve analyses suggested that DAFS-BR has good sensitivity and specificity to identify MCI and AD. Results suggest that DAFS-BR can document degrees of severity of functional impairment among Brazilian older adults.