945 resultados para MRI-guided cryoablation
Resumo:
PURPOSE: Respiratory motion correction remains a challenge in coronary magnetic resonance imaging (MRI) and current techniques, such as navigator gating, suffer from sub-optimal scan efficiency and ease-of-use. To overcome these limitations, an image-based self-navigation technique is proposed that uses "sub-images" and compressed sensing (CS) to obtain translational motion correction in 2D. The method was preliminarily implemented as a 2D technique and tested for feasibility for targeted coronary imaging. METHODS: During a 2D segmented radial k-space data acquisition, heavily undersampled sub-images were reconstructed from the readouts collected during each cardiac cycle. These sub-images may then be used for respiratory self-navigation. Alternatively, a CS reconstruction may be used to create these sub-images, so as to partially compensate for the heavy undersampling. Both approaches were quantitatively assessed using simulations and in vivo studies, and the resulting self-navigation strategies were then compared to conventional navigator gating. RESULTS: Sub-images reconstructed using CS showed a lower artifact level than sub-images reconstructed without CS. As a result, the final image quality was significantly better when using CS-assisted self-navigation as opposed to the non-CS approach. Moreover, while both self-navigation techniques led to a 69% scan time reduction (as compared to navigator gating), there was no significant difference in image quality between the CS-assisted self-navigation technique and conventional navigator gating, despite the significant decrease in scan time. CONCLUSIONS: CS-assisted self-navigation using 2D translational motion correction demonstrated feasibility of producing coronary MRA data with image quality comparable to that obtained with conventional navigator gating, and does so without the use of additional acquisitions or motion modeling, while still allowing for 100% scan efficiency and an improved ease-of-use. In conclusion, compressed sensing may become a critical adjunct for 2D translational motion correction in free-breathing cardiac imaging with high spatial resolution. An expansion to modern 3D approaches is now warranted.
Resumo:
Actualment, en l'àmbit mèdic, la ressonància magnètica, MRI Magnetic Resonance Imaging, és un dels sistemes més utilitzats per a la realització de diagnòstics i el seguiment de l'evolució de malalties com l'esclerosi múltiple (EM). No obstant, la gran quantitat d'informació que proporciona aquesta modalitat té com a conseqüència una tasca feixuga d'anàlisi i d'interpretació per part dels radiòlegs i neuròlegs. L'objectiu general d'aquest projecte és desenvolupar un sistema per ajudar als metges a segmentar les imatges de MRI del cervell. S'ha implementat amb MATLAB. Durant tot el procés s'han utilitzat dades sintètiques, de la base de dades simulada BrainWeb, i reals, proporcionades pels grup de metges col•laboradors amb el grup VICOROB.El projecte s'emmarca dins d'un projecte de recerca del grup de Visió per Computador i Robòtica de la Universitat de Girona
Resumo:
Although a metastatic presentation of an occult prostatic adenocarcinoma is not uncommon, the majority of these patients present with bone metastasis affecting the axial skeleton. Cranial metastases to the paranasal sinuses are extremely rare. A 56-year-old man presented with loss of vision and numbness of the right side of the face. Computed tomography (CT) scan and cranial magnetic resonance imaging (MRI) revealed a mass invading the sphenoid sinus. The patient underwent surgery to remove the lesion, and the histopathological examination suggested metastasis of an adenocarcinoma, with positive staining to prostatic specific antigen (PSA). However, serum PSA was 4 ng/mL, and the patient did not report any lower urinary tract symptoms or bone pain. Transrectal ultrasound-guided biopsy revealed prostatic adenocarcinomas with a Gleason score of 8 [4 + 4]. The subsequent treatment consisted of radiotherapy and androgen deprivation, followed by first- and second-line chemotherapy (docetaxel and cabazitaxel) when the disease progressed. The patient achieved a good response with the last cycle of cabazitaxel and after a 5-year followup is currently alive. Cranial metastases of prostate adenocarcinoma are rare, and there is currently no standard treatment for these patients. Whenever possible, surgery combined with radiotherapy and hormonotherapy is the recommended option.
Resumo:
BACKGROUND Major depression will become the second most important cause of disability in 2020. Computerized cognitive-behaviour therapy could be an efficacious and cost-effective option for its treatment. No studies on cost-effectiveness of low intensity vs self-guided psychotherapy has been carried out. The aim of this study is to assess the efficacy of low intensity vs self-guided psychotherapy for major depression in the Spanish health system. METHODS The study is made up of 3 phases: 1.- Development of a computerized cognitive-behaviour therapy for depression tailored to Spanish health system. 2.- Multicenter controlled, randomized study: A sample (N=450 patients) with mild/moderate depression recruited in primary care. They should have internet availability at home, not receive any previous psychological treatment, and not suffer from any other severe somatic or psychological disorder. They will be allocated to one of 3 treatments: a) Low intensity Internet-delivered psychotherapy + improved treatment as usual (ITAU) by GP, b) Self-guided Internet-delivered psychotherapy + ITAU or c) ITAU. Patients will be diagnosed with MINI psychiatric interview. Main outcome variable will be Beck Depression Inventory. It will be also administered EuroQol 5D (quality of life) and Client Service Receipt Inventory (consume of health and social services). Patients will be assessed at baseline, 3 and 12 months. An intention to treat and a per protocol analysis will be performed. DISCUSSION The comparisons between low intensity and self-guided are infrequent, and also a comparative economic evaluation between them and compared with usual treatment in primary. The strength of the study is that it is a multicenter, randomized, controlled trial of low intensity and self-guided Internet-delivered psychotherapy for depression in primary care, being the treatment completely integrated in primary care setting. TRIAL REGISTRATION Clinical Trials NCT01611818.
Resumo:
Researchers working in the field of global connectivity analysis using diffusion magnetic resonance imaging (MRI) can count on a wide selection of software packages for processing their data, with methods ranging from the reconstruction of the local intra-voxel axonal structure to the estimation of the trajectories of the underlying fibre tracts. However, each package is generally task-specific and uses its own conventions and file formats. In this article we present the Connectome Mapper, a software pipeline aimed at helping researchers through the tedious process of organising, processing and analysing diffusion MRI data to perform global brain connectivity analyses. Our pipeline is written in Python and is freely available as open-source at www.cmtk.org.
Resumo:
Purpose: To compare MDCT, MRI and 18F-FDG PET/CT for the detection of peritoneal carcinomatosis due to ovarian cancerMethods and Materials: Fifteen women (mean age 65±) with clinical suspicion of ovarian cancer and peritoneal carcinomatosis underwent MDCT, MRI and 18F-FDG PET/CT, simultaneously and shortly performed before surgery (delay 8.1± days). According to the peritoneal cancer index nine abdominopelvic regions were defined. We applied four scores of lesion size on MDCT and MR images, while the maximal standard uptake value (SUVmax) was measured on 18F-FDG PET/CT. Three sites of lymphadenopathy and posterobasal pleural carcinomatosis were also analyzed. First, one radiologist blindly and separately read MDCT and MR images, while one nuclear physician blindly read PET/CT images grading each lesion according to four diagnostic certitudes. Secondly, all the images were reviewed jointly and compared with histopathology. Receiver operating characteristics (ROC) analysis was performed.Results: Peritoneal implants were proven in ten women (75%). Altogether, 228 abdominopelvic sites were compared. Sensitivity and specificity for MDCT was 90.2% and 90.6%, for MRI 93.5% and 86.3%, and for 18F-FDG PET/CT 92.7% and 95.7%, respectively. ROC area under the curve were 0.93 for MDCT and MRI, and 0.96 for 18F-FDG PET/CT respectively. No significant differences (p=0.11) were found between the three modalities.Conclusion: Although MRI revealed to be the most sensitive and 18F-FDG PET/CT the most specific modality, no significant differences were shown between the three techniques.
Resumo:
In this study, hypothalamic activation was performed by dehydration-induced anorexia (DIA) and overnight food suppression (OFS) in female rats. The assessment of the hypothalamic response to these challenges by manganese-enhanced MRI showed increased neuronal activity in the paraventricular nuclei (PVN) and lateral hypothalamus (LH), both known to be areas involved in the regulation of food intake. The effects of DIA and OFS were compared by generating T-score maps. Increased neuronal activation was detected in the PVN and LH of DIA rats relative to OFS rats. In addition, the neurochemical profile of the PVN and LH were measured by (1) H MRS at 14.1T. Significant increases in metabolite levels were measured in DIA and OFS relative to control rats. Statistically significant increases in γ-aminobutyric acid were found in DIA (p=0.0007) and OFS (p<0.001) relative to control rats. Lactate increased significantly in DIA (p=0.03), but not in OFS, rats. This work shows that manganese-enhanced MRI coupled to (1) H MRS at high field is a promising noninvasive method for the investigation of the neural pathways and mechanisms involved in the control of food intake, in the autonomic and endocrine control of energy metabolism and in the regulation of body weight.
Resumo:
Most patients with symptomatic internal carotid artery occlusion have a single minor or major hemispheric stroke. A minority of patients have ipsilateral retinal ischemia, recurrent strokes, or transient ischemic attacks. Whereas spontaneous carotid recanalization is rare, acute surgical recanalization has been attempted, with mixed results. Recently, acute endovascular recanalization has been performed and described as feasible and relatively safe. We describe a patient with symptom recurrence related to hemodynamic factors after occlusion of the carotid artery who was successfully treated 14 days after symptom onset.
Resumo:
Mapping the human auditory cortex with standard functional imaging techniques is difficult because of its small size and angular position along the Sylvian fissure. As a result, the exact number and location of auditory cortex areas in the human remains unknown. In a first experiment, we measured the two largest tonotopic areas of primary auditory cortex (PAC, Al and R) using high-resolution functional MRI at 7 Tesla relative to the underlying anatomy of Heschl's gyrus (HG). The data reveals a clear anatomical- functional relationship that indicates the location of PAC across the range of common morphological variants of HG (single gyri, partial duplication and complete duplication). Human PAC tonotopic areas are oriented along an oblique posterior-to-anterior axis with mirror-symmetric frequency gradients perpendicular to HG, as in the macaque. In a second experiment, we tested whether these primary frequency-tuned units were modulated by selective attention to preferred vs. non-preferred sound frequencies in the dynamic manner needed to account for human listening abilities in noisy environments, such as cocktail parties or busy streets. We used a dual-stream selective attention experiment where subjects attended to one of two competing tonal streams presented simultaneously to different ears. Attention to low-frequency tones (250 Hz) enhanced neural responses within low-frequency-tuned voxels relative to high (4000 Hz), and vice versa when at-tention switched from high to low. Human PAC is able to tune into attended frequency channels and can switch frequencies on demand, like a radio. In a third experiment, we investigated repetition suppression effects to environmental sounds within primary and non-primary early-stage auditory areas, identified with the tonotopic mapping design. Repeated presentations of sounds from the same sources, as compared to different sources, gave repetition suppression effects within posterior and medial non-primary areas of the right hemisphere, reflecting their potential involvement in semantic representations. These three studies were conducted at 7 Tesla with high-resolution imaging. However, 7 Tesla scanners are, for the moment, not yet used for clinical diagnosis and mostly reside in institutions external to hospitals. Thus, hospital-based clinical functional and structural studies are mainly performed using lower field systems (1.5 or 3 Tesla). In a fourth experiment, we acquired tonotopic maps at 3 and 7 Tesla and evaluated the consistency of a tonotopic mapping paradigm between scanners. Mirror-symmetric gradients within PAC were highly similar at 7 and 3 Tesla across renderings at different spatial resolutions. We concluded that the tonotopic mapping paradigm is robust and suitable for definition of primary tonotopic areas, also at 3 Tesla. Finally, in a fifth study, we considered whether focal brain lesions alter tonotopic representations in the intact ipsi- and contralesional primary auditory cortex in three patients with hemispheric or cerebellar lesions, without and with auditory complaints. We found evidence for tonotopic reorganisation at the level of the primary auditory cortex in cases of brain lesions independently of auditory complaints. Overall, these results reflect a certain degree of plasticity within primary auditory cortex in different populations of subjects, assessed at different field strengths. - La cartographie du cortex auditif chez l'humain est difficile à réaliser avec des techniques d'imagerie fonctionnelle standard, étant donné sa petite taille et position angulaire le long de la fissure sylvienne. En conséquence, le nombre et l'emplacement exacts des différentes aires du cortex auditif restent inconnus chez l'homme. Lors d'une première expérience, nous avons mesuré, avec de l'imagerie par résonance magnétique à haute intensité (IRMf à 7 Tesla) chez des sujets humains sains, deux larges aires au sein du cortex auditif primaire (PAC; Al et R) avec une représentation spécifique des fréquences pures préférées - ou tonotopie. Nos résultats ont démontré une relation anatomico- fonctionnelle qui définit clairement la position du PAC à travers toutes les variantes du gyrus d'Heschl's (HG). Les aires tonotopiques du PAC humain sont orientées le long d'un axe postéro-antérieur oblique avec des gradients de fréquences spécifiques perpendiculaires à HG, d'une manière similaire à celles mesurées chez le singe. Dans une deuxième expérience, nous avons testé si ces aires primaires pouvaient être modulées, de façon dynamique, par une attention sélective pour des fréquences préférées par rapport à celles non-préférées. Cette modulation est primordiale lors d'interactions sociales chez l'humain en présence de bruits distracteurs tels que d'autres discussions ou un environnement sonore nuisible (comme par exemple, dans la circulation routière). Dans cette étude, nous avons utilisé une expérience d'attention sélective où le sujet devait être attentif à une des deux voies sonores présentées simultanément à chaque oreille. Lorsque le sujet portait était attentif aux sons de basses fréquences (250 Hz), la réponse neuronale relative à ces fréquences augmentait par rapport à celle des hautes fréquences (4000 Hz), et vice versa lorsque l'attention passait des hautes aux basses fréquences. De ce fait, nous pouvons dire que PAC est capable de focaliser sur la fréquence attendue et de changer de canal selon la demande, comme une radio. Lors d'une troisième expérience, nous avons étudié les effets de suppression due à la répétition de sons environnementaux dans les aires auditives primaires et non-primaires, d'abord identifiées via le protocole de la première étude. La présentation répétée de sons provenant de la même source sonore, par rapport à de sons de différentes sources sonores, a induit un effet de suppression dans les aires postérieures et médiales auditives non-primaires de l'hémisphère droite, reflétant une implication de ces aires dans la représentation de la catégorie sémantique. Ces trois études ont été réalisées avec de l'imagerie à haute résolution à 7 Tesla. Cependant, les scanners 7 Tesla ne sont pour le moment utilisés que pour de la recherche fondamentale, principalement dans des institutions externes, parfois proches du patient mais pas directement à son chevet. L'imagerie fonctionnelle et structurelle clinique se fait actuellement principalement avec des infrastructures cliniques à 1.5 ou 3 Tesla. Dans le cadre dune quatrième expérience, nous avons avons évalués la cohérence du paradigme de cartographie tonotopique à travers différents scanners (3 et 7 Tesla) chez les mêmes sujets. Nos résultats démontrent des gradients de fréquences définissant PAC très similaires à 3 et 7 Tesla. De ce fait, notre paradigme de définition des aires primaires auditives est robuste et applicable cliniquement. Finalement, nous avons évalués l'impact de lésions focales sur les représentations tonotopiques des aires auditives primaires des hémisphères intactes contralésionales et ipsilésionales chez trois patients avec des lésions hémisphériques ou cérébélleuses avec ou sans plaintes auditives. Nous avons trouvé l'évidence d'une certaine réorganisation des représentations topographiques au niveau de PAC dans le cas de lésions cérébrales indépendamment des plaintes auditives. En conclusion, nos résultats démontrent une certaine plasticité du cortex auditif primaire avec différentes populations de sujets et différents champs magnétiques.
Resumo:
OBJECTIVE: The objective of our study was to report the MRI findings in dorsal fractures of the triquetrum, with an emphasis on dorsal carpal ligament injuries. MATERIALS AND METHODS: A total of 21 patients (16 men, five women; mean age, 41.9 years) with acute or subacute (≤ 6 weeks) dorsal triquetral fractures on radiography and MRI were included in this two-center retrospective study. MRI of the wrist was performed on 3-T units with transverse T1-weighted, coronal or transverse (or both) fat-suppressed T2weighted, transverse gadolinium-enhanced fat-suppressed T1-weighted turbo spin-echo, and 3D gadolinium-enhanced fat-suppressed T1-weighted gradient-recalled echo sequences. Three musculoskeletal radiologists evaluated the ulnar styloid process index (USPI) on radiographs and the following MRI features: fracture pattern (types 1-6), bone fragment size and displacement, bone marrow edema distribution, and dorsal carpal ligament tears. RESULTS: Eight type 1, one type 2, six type 3, five type 4, and one type 5 fractures were identified. These fractures were associated with 14 (66.7%), 17 (81.0%), and 16 (76.2%) tears of the dorsal radiocarpal, ulnotriquetral, and intercarpal ligaments, respectively. There was no correlation between bone marrow edema distribution and dorsal carpal ligament injuries (all p > 0.05). The mean (± SD) bone fragment volume and displacement were 205 ± 157 mm(3) and 1.0 ± 1.1 mm, respectively. The mean USPI was 0.21 ± 0.10. CONCLUSION: Dorsal fractures of the triquetrum are frequently associated with dorsal carpal ligament injuries. Bone marrow edema distribution is not correlated with these ligament tears.
Resumo:
On the basis of MRI examinations in 88 neonates and infants with perinatal asphyxia, we defined 6 different patterns on T2-weighted images: pattern A--scattered hyperintensity of both hemispheres of the telencephalon with blurred border zones between cortex and white matter, indicating diffuse brain injury; pattern B--parasagittal hyperintensity extending into the corona radiata, corresponding to the watershed zones; pattern C--hyper- and hypointense lesions in thalamus and basal ganglia, which relate to haemorrhagic necrosis or iron deposition in these areas; pattern D--periventricular hyperintensity, mainly along the lateral ventricles, i.e. periventricular leukomalacia (PVL), originating from the matrix zone; pattern E--small multifocal lesions varying from hyper--to hypointense, interpreted as necrosis and haemorrhage; pattern F--periventricular centrifugal hypointense stripes in the centrum semiovale and deep white matter of the frontal and occipital lobes. Contrast was effectively inverted on T1-weighted images. Patterns A, B and C were found in 17%, 25% and 37% of patients, and patterns D, E and F in 19%, 17% and 35%, respectively. In 49 patients a combination of patterns was observed, but 30% of the initial images were normal. At follow-up, persistent abnormalities were seen in all children with patterns A and D, but in only 52% of those with pattern C. Myelination was retarded most often in patients with diffuse brain injury and PVL (patterns A and D).
Resumo:
PURPOSE: To compare the apparent diffusion coefficient (ADC) values of malignant liver lesions on diffusion-weighted MRI (DWI) before and after successful radiofrequency ablation (RF ablation). MATERIALS AND METHODS: Thirty-two patients with 43 malignant liver lesions (23/20: metastases/hepatocellular carcinomas (HCC)) underwent liver MRI (3.0T) before (<1month) and after RF ablation (at 1, 3 and 6months) using T2-, gadolinium-enhanced T1- and DWI-weighted MR sequences. Jointly, two radiologists prospectively measured ADCs for each lesion by means of two different regions of interest (ROIs), first including the whole lesion and secondly the area with the visibly most restricted diffusion (MRDA) on ADC map. Changes of ADCs were evaluated with ANOVA and Dunnett tests. RESULTS: Thirty-one patients were successfully treated, while one patient was excluded due to focal recurrence. In metastases (n=22), the ADC in the whole lesion and in MRDA showed an up-and-down evolution. In HCC (n=20), the evolution of ADC was more complex, but with significantly higher values (p=0.013) at 1 and 6months after RF ablation. CONCLUSION: The ADC values of malignant liver lesions successfully treated by RF ablation show a predictable evolution and may help radiologists to monitor tumor response after treatment.