963 resultados para LED backlight


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, a LED (light emitting diode) based photometer for solid phase photometry is described. The photometer was designed to permit direct coupling of a light source (LED) and a photodiode to a flow cell with an optical pathlength of 4 mm. The flow cell was filled with adsorbing solid phase material (C-18), which was used to immobilize the chromogenic reagent 1-(2-thiazolylazo)-2-naphthol (TAN). Aiming to allow accuracy assessment, samples were also analyzed employing ICP OES (inductively coupled plasma optical emission spectrometry) methodology. Applying the paired t-test at the 95% confidence level, no significant difference was observed. Other useful features were also achieved: linear response ranging from 0.05 to 0.85 mg L-1 Zn, limit of detection of 9 mu g L-1 Zn (3 sigma criterion), standard deviation of 1.4% (n = 10), sampling throughput of 36 determinations per h, and a waste generation and reagent consumption of 1.7 mL and of 0.03 mu g per determination, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this manuscript, an automatic setup for screening of microcystins in surface waters by employing photometric detection is described. Microcystins are toxins delivered by cyanobacteria within an aquatic environment, which have been considered strongly poisonous for humans. For that reason, the World Health Organization (WHO) has proposed a provisional guideline value for drinking water of 1 mu g L-1. In this work, we developed an automated equipment setup, which allows the screening of water for concentration of microcystins below 0.1 mu g V. The photometric method was based on the enzyme-linked immunosorbent assay (ELISA) and the analytical signal was monitored at 458 nm using a homemade LED-based photometer. The proposed system was employed for the detection of microcystins in rivers and lakes waters. Accuracy was assessed by processing samples using a reference method and applying the paired t-test between results. No significant difference at the 95% confidence level was observed. Other useful features including a linear response ranging from 0.05 up to 2.00 mu g L-1 (R-2 =0.999) and a detection limit of 0.03 mu g L-1 microcystins were achieved. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neste trabalho é proposto um fotômetro baseado em LED (diodo emissor de luz) para fotometria em fase sólida. O fotômetro foi desenvolvido para permitir o acoplamento da fonte de radiação (LED) e do fotodetector direto na cela de fluxo, tendo um caminho óptico de 4 mm. A cela de fluxo foi preenchida com material sólido (C18), o qual foi utilizado para imobilizar o reagente cromogênico 1-(2-tiazolilazo)-2-naftol (TAN). A exatidão foi avaliada empregando dados obtidos através da técnica ICP OES (espectrometria de emissão por plasma indutivamente acoplado). Aplicando-se o teste-t pareado não foi observada diferença significativa em nível de confiança de 95%. Outros parâmetros importantes encontrados foram faixa de resposta linear de 0,05 a 0,85 mg L-1 Zn, limite de detecção de 9 µg L-1 Zn (n = 3), desvio padrão de 1,4 % (n = 10), frequência de amostragem de 36 determinações por h, e uma geração de efluente e consumo de reagente de 1,7 mL e 0,03 µg por determinação, respectivamente.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In questa tesi viene descritto il funzionamento delle sorgenti di luce LED (Light Emitting Diode) a confinamento quantico, che rappresentano la nuova frontiera dell'illuminazione ad alta efficienza e durata. Nei capitoli introduttivi è descritta brevemente la storia dei LEDs dalla loro invenzione agli sviluppi più recenti. Il funzionamento di tali dispositivi fotonici è spiegato a partire dal concetto di sorgente di luce per elettroluminescenza, con particolare riferimento alle eterostrutture a confinamento quantico bidimensionale (quantum wells). I capitoli centrali riguardano i nitruri dei gruppi III-V, le cui caratteristiche e proprietà hanno permesso di fabbricare LEDs ad alta efficienza e ampio spettro di emissione, soprattutto in relazione al fatto che i LEDs a nitruri dei gruppi III-V emettono luce anche in presenza di alte densità di difetti estesi, nello specifico dislocazioni. I capitoli successivi sono dedicati alla presentazione del lavoro sperimentale svolto, che riguarda la caratterizzazione elettrica, ottica e strutturale di LEDs a confinamento quantico basati su nitruri del gruppo III-V GaN e InGaN, cresciuti nei laboratori di Cambridge dal Center for Gallium Nitride. Lo studio ha come obiettivo finale il confronto dei risultati ottenuti su LEDs con la medesima struttura epitassiale, ma differente densità di dislocazioni, allo scopo di comprendere meglio il ruolo che tali difetti estesi ricoprono nella determinazione dell'effcienza delle sorgenti di luce LED. L’ultimo capitolo riguarda la diffrazione a raggi X dal punto di vista teorico, con particolare attenzione ai metodi di valutazioni dello strain reticolare nei wafer a nitruri, dal quale dipende la densità di dislocazioni.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Medication-related problems are common in the growing population of older adults and inappropriate prescribing is a preventable risk factor. Explicit criteria such as the Beers criteria provide a valid instrument for describing the rate of inappropriate medication (IM) prescriptions among older adults. Objective: To reduce IM prescriptions based on explicit Beers criteria using a nurse-led intervention in a nursing-home (NH) setting. Study Design: The pre/post-design included IM assessment at study start (pre-intervention), a 4-month intervention period, IM assessment after the intervention period (post-intervention) and a further IM assessment at 1-year follow-up. Setting: 204-bed inpatient NH in Bern, Switzerland. Participants: NH residents aged ≥60 years. Intervention: The intervention included four key intervention elements: (i) adaptation of Beers criteria to the Swiss setting; (ii) IM identification; (iii) IM discontinuation; and (iv) staff training. Main Outcome Measure: IM prescription at study start, after the 4-month intervention period and at 1-year follow-up. Results: The mean±SD resident age was 80.3±8.8 years. Residents were prescribed a mean±SD 7.8±4.0 medications. The prescription rate of IMs decreased from 14.5% pre-intervention to 2.8% post-intervention (relative risk [RR] = 0.2; 95% CI 0.06, 0.5). The risk of IM prescription increased nonstatistically significantly in the 1-year follow-up period compared with post-intervention (RR = 1.6; 95% CI 0.5, 6.1). Conclusions: This intervention to reduce IM prescriptions based on explicit Beers criteria was feasible, easy to implement in an NH setting, and resulted in a substantial decrease in IMs. These results underscore the importance of involving nursing staff in the medication prescription process in a long-term care setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: The purpose of this study was to evaluate the activation of resin-modified glass ionomer restorative material (RMGI, Vitremer-3M-ESPE, A3) by halogen lamp (QTH) or light-emitting diode (LED) by Knoop microhardness (KHN) in two storage conditions: 24hrs and 6 months and in two depths (0 and 2 mm). MATERIALS AND METHODS: The specimens were randomly divided into 3 experimental groups (n=10) according to activation form and evaluated in depth after 24h and after 6 months of storage. Activation was performed with QTH for 40s (700 mW/cm2) and for 40 or 20 s with LED (1,200 mW/scm2). After 24 hrs and 6 months of storage at 37°C in relative humidity in lightproof container, the Knoop microhardness test was performed. Statistics Data were analysed by three-way ANOVA and Tukey post-tests (p<0.05). RESULTS: All evaluated factors showed significant differences (p<0.05). After 24 hrs there were no differences within the experimental groups. KHN at 0 mm was significantly higher than 2 mm. After 6 months, there was an increase of microhardness values for all groups, being the ones activated by LED higher than the ones activated by QTH. CONCLUSION: Light-activation with LED positively influenced the KHN for RMGI evaluated after 6 months.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Class II cavities were prepared in extracted lower molars filled and cured in three 2-mm increments using a metal matrix. Three composites (Spectrum TPH A4, Ceram X mono M7 and Tetric Ceram A4) were cured with both the SmartLite PS LED LCU and the Spectrum 800 continuous cure halogen LCU using curing cycles of 10, 20 and 40 seconds. Each increment was cured before adding the next. After a seven-day incubation period, the composite specimens were removed from the teeth, embedded in self-curing resin and ground to half the orofacial width. Knoop microhardness was determined 100, 200, 500, 1000, 1500, 2500, 3500, 4500 and 5500 microm from the occlusal surface at a distance of 150 microm and 1000 microm from the metal matrix. The total degree of polymerization of a composite specimen for any given curing time and curing light was determined by calculating the area under the hardness curve. Hardness values 150 microm from the metal matrix never reached maximum values and were generally lower than those 1000 microm from the matrix. The hardest composite was usually encountered between 200 microm and 1000 microm from the occlusal surface. For every composite-curing time combination, there was an increase in microhardness at the top of each increment (measurements at 500, 2500 and 4500 microm) and a decrease towards the bottom of each increment (measurements at 1500, 3500 and 5500 microm). Longer curing times were usually combined with harder composite samples. Spectrum TPH composite was the only composite showing a satisfactory degree of polymerization for all three curing times and both LCUs. Multiple linear regression showed that only the curing time (p < 0.001) and composite material (p < 0.001) had a significant association with the degree of polymerization. The degree of polymerization achieved by the LED LCU was not significantly different from that achieved by the halogen LCU (p = 0.54).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives The aim of this study was to measure the degree of conversion (DC) of five dual-curing resin cements after different curing modes with a second- and a third-generation light-emitting diode (LED) curing unit. Additionally, irradiance of both light curing units was measured at increasing distances and through discs of two glass ceramics for computer-aided design/manufacturing (CAD/CAM). Materials and methods Irradiance and spectra of the Elipar FreeLight 2 (Standard Mode (SM)) and of the VALO light curing unit (High Power Mode (HPM) and Xtra Power Mode (XPM)) were measured with a MARC radiometer. Irradiance was measured at increasing distances (control) and through discs (1.5 to 6 mm thickness) of IPS Empress CAD and IPS e.max CAD. DC of Panavia F2.0, RelyX Unicem 2 Automix, SpeedCEM, BisCem, and BeautiCem SA was measured with an attenuated total reflectance–Fourier transform infrared spectrometer when self-cured (negative control) or light cured in SM for 40 s, HPM for 32 s, or XPM for 18 s. Light curing was performed directly (positive control) or through discs of either 1.5- or 3-mm thickness of IPS Empress CAD or IPS e.max CAD. DC was analysed with Kruskal–Wallis tests followed by pairwise Wilcoxon rank sum tests (α = 0.05). Results Maximum irradiances were 1,545 mW/cm2 (SM), 2,179 mW/cm2 (HPM), and 4,156 mW/cm2 (XPM), and all irradiances decreased by >80 % through discs of 1.5 mm, ≥95 % through 3 mm, and up to >99 % through 6 mm. Generally, self-curing resulted in the lowest DC. For some cements, direct light curing did not result in higher DC compared to when light cured through ceramic discs. For other cements, light curing through ceramic discs of 3 mm generally reduced DC. Conclusions Light curing was favourable for dual-curing cements. Some cements were more susceptible to variations in curing mode than others. Clinical relevance When light curing a given cement, the higher irradiances of the third-generation LED curing unit resulted in similar DC compared to the second-generation one, though at shorter light curing times.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The recent increase in prices and production of quinoa have had important effects on the employment structures and livelihoods of rural communities in the Nor Lipez Province (Bolivia). The "quinoa boom" resulted in significant changes in household incomes and in gender roles in the context of increasing market integration. The nature of these changes however is not easy to grasp, as new official narratives on gender and on traditional systems of labour divisions and shared access to land have surfaced since the election of Evo Morales (2006) and the adoption of a new constitution (2009). Furthermore, rural employment is found to be much more diverse than the term suggests. Women have always participated in the production of quinoa when it was widely considered as a subsistence crop. Our research takes place in the Nor Lipez Province, Bolivia with exploratory studies that were conducted in January and February 2015 in 8 rural communities of quinoa producers. Preliminary results suggest positive effects for local women in that they managed to earn additional income which might have contributed to their empowerment. This article will present both preliminary results, challenges for gender-oriented research in Bolivia and the methodology aiming to capture changes at the individual, the household and the community level through a survey that will be conducted from September to November 2015 in 500 households.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The metabolic network of a cell represents the catabolic and anabolic reactions that interconvert small molecules (metabolites) through the activity of enzymes, transporters and non-catalyzed chemical reactions. Our understanding of individual metabolic networks is increasing as we learn more about the enzymes that are active in particular cells under particular conditions and as technologies advance to allow detailed measurements of the cellular metabolome. Metabolic network databases are of increasing importance in allowing us to contextualise data sets emerging from transcriptomic, proteomic and metabolomic experiments. Here we present a dynamic database, TrypanoCyc (http://www.metexplore.fr/trypanocyc/), which describes the generic and condition-specific metabolic network of Trypanosoma brucei, a parasitic protozoan responsible for human and animal African trypanosomiasis. In addition to enabling navigation through the BioCyc-based TrypanoCyc interface, we have also implemented a network-based representation of the information through MetExplore, yielding a novel environment in which to visualise the metabolism of this important parasite.