967 resultados para Image quality
Resumo:
Introduction: The purpose of this review is to gather and analyse current research publications to evaluate Sinogram-Affirmed Iterative Reconstruction (SAFIRE). The aim of this review is to investigate whether this algorithm is capable of reducing the dose delivered during CT imaging while maintaining image quality. Recent research shows that children have a greater risk per unit dose due to increased radiosensitivity and longer life expectancies, which means it is particularly important to reduce the radiation dose received by children. Discussion: Recent publications suggest that SAFIRE is capable of reducing image noise in CT images, thereby enabling the potential to reduce dose. Some publications suggest a decrease in dose, by up to 64% compared to filtered back projection, can be accomplished without a change in image quality. However, literature suggests that using a higher SAFIRE strength may alter the image texture, creating an overly ‘smoothed’ image that lacks contrast. Some literature reports SAFIRE gives decreased low contrast detectability as well as spatial resolution. Publications tend to agree that SAFIRE strength three is optimal for an acceptable level of visual image quality, but more research is required. The importance of creating a balance between dose reduction and image quality is stressed. In this literature review most of the publications were completed using adults or phantoms, and a distinct lack of literature for paediatric patients is noted. Conclusion: It is necessary to find an optimal way to balance dose reduction and image quality. More research relating to SAFIRE and paediatric patients is required to fully investigate dose reduction potential in this population, for a range of different SAFIRE strengths.
Resumo:
Aims of study: 1) Describe the importance of human visual system on lesion detection in medical imaging perception research; 2) Discuss the relevance of research in medical imaging addressing visual function analysis; 3) Identify visual function tests which could be conducted on observers prior to participation in medical imaging perception research.
Resumo:
This review aims to identify strategies to optimise radiography practice using digital technologies, for full spine studies on paediatrics focusing particularly on methods used to diagnose and measure severity of spinal curvatures. The literature search was performed on different databases (PubMed, Google Scholar and ScienceDirect) and relevant websites (e.g., American College of Radiology and International Commission on Radiological Protection) to identify guidelines and recent studies focused on dose optimisation in paediatrics using digital technologies. Plain radiography was identified as the most accurate method. The American College of Radiology (ACR) and European Commission (EC) provided two guidelines that were identified as the most relevant to the subject. The ACR guidelines were updated in 2014; however these guidelines do not provide detailed guidance on technical exposure parameters. The EC guidelines are more complete but are dedicated to screen film systems. Other studies provided reviews on the several exposure parameters that should be included for optimisation, such as tube current, tube voltage and source-to-image distance; however, only explored few of these parameters and not all of them together. One publication explored all parameters together but this was for adults only. Due to lack of literature on exposure parameters for paediatrics, more research is required to guide and harmonise practice.
Resumo:
Aim: Optimise a set of exposure factors, with the lowest effective dose, to delineate spinal curvature with the modified Cobb method in a full spine using computed radiography (CR) for a 5-year-old paediatric anthropomorphic phantom. Methods: Images were acquired by varying a set of parameters: positions (antero-posterior (AP), posteroanterior (PA) and lateral), kilo-voltage peak (kVp) (66-90), source-to-image distance (SID) (150 to 200cm), broad focus and the use of a grid (grid in/out) to analyse the impact on E and image quality (IQ). IQ was analysed applying two approaches: objective [contrast-to-noise-ratio/(CNR] and perceptual, using 5 observers. Monte-Carlo modelling was used for dose estimation. Cohen’s Kappa coefficient was used to calculate inter-observer-variability. The angle was measured using Cobb’s method on lateral projections under different imaging conditions. Results: PA promoted the lowest effective dose (0.013 mSv) compared to AP (0.048 mSv) and lateral (0.025 mSv). The exposure parameters that allowed lower dose were 200cm SID, 90 kVp, broad focus and grid out for paediatrics using an Agfa CR system. Thirty-seven images were assessed for IQ and thirty-two were classified adequate. Cobb angle measurements varied between 16°±2.9 and 19.9°±0.9. Conclusion: Cobb angle measurements can be performed using the lowest dose with a low contrast-tonoise ratio. The variation on measurements for this was ±2.9° and this is within the range of acceptable clinical error without impact on clinical diagnosis. Further work is recommended on improvement to the sample size and a more robust perceptual IQ assessment protocol for observers.
Resumo:
Patients scheduled for a magnetic resonance imaging (MRI) scan sometimes require screening for ferromagnetic Intra Orbital Foreign Bodies (IOFBs). To assess this, they are required to fill out a screening protocol questionnaire before their scan. If it is established that a patient is at high risk, radiographic imaging is necessary. This review examines literature to evaluate which imaging modality should be used to screen for IOFBs, considering that the eye is highly sensitive to ionising radiation and any dose should be minimised. Method: Several websites and books were searched for information, these were as follows: PubMed, Science Direct, Web of Knowledge and Google Scholar. The terms searched related to IOFB, Ionising radiation, Magnetic Resonance Imaging Safety, Image Quality, Effective Dose, Orbits and X-ray. Thirty five articles were found, several were rejected due to age or irrelevance; twenty eight were eventually accepted. Results: There are several imaging techniques that can be used. Some articles investigated the use of ultrasound for investigation of ferromagnetic IOFBs of the eye and others discussed using Computed Tomography (CT) and X-ray. Some gaps in the literature were identified, mainly that there are no articles which discuss the lowest effective dose while having adequate image quality for orbital imaging. Conclusion: X-ray is the best method to identify IOFBs. The only problem is that there is no research which highlights exposure factors that maintain sufficient image quality for viewing IOFBs and keep the effective dose to the eye As Low As Reasonably Achievable (ALARA).
Resumo:
Purpose: Pressure ulcers are a high cost, high volume issue for health and medical care providers, having a detrimental effect on patients and relatives. Pressure ulcer prevention is widely covered in the literature, but little has been published regarding the risk to patients in the radiographical setting. This review of the current literature is to identify findings relevant to radiographical context. Methods: Literature searching was performed using Science Direct and Medline databases. The search was limited to articles published in the last ten years to remain current and excluded studies containing participants less than 17 years of age. In total 14 studies were acquired; three were excluded as they were not relevant. The remaining 11 studies were compared and reviewed. Discussion: Eight of the studies used ‘healthy’ participants and three used symptomatic participants. Nine studies explored interface pressure with a range of pressure mat technologies, two studies measured shear (MRI finite element modelling, and a non-invasive instrument), and one looked at blood flow and haemoglobin oxygenation. A range of surfaces were considered from trauma, nursing and surgical backgrounds for their ability to reduce pressure including standard mattresses, high specification mattresses, rigid and soft layer spine boards, various overlays (gel, air filled, foam). Conclusion: The current literature is not appropriate for the radiographic patient and cannot be extrapolated to a radiologic context. Sufficient evidence is presented in this review to support the need for further work specific to radiography in order to minimise the development of PU in at risk patients.
Resumo:
Introduction: Pressure ulcers are a high cost, high volume issue for health and medical care providers, affecting patients’ recovery and psychological wellbeing. The current research of support surfaces on pressure as a risk factor in the development of pressure ulcers is not relevant to the specialised, controlled environment of the radiological setting. Method: 38 healthy participants aged 19-51 were placed supine on two different imaging surfaces. The XSENSOR pressure mapping system was used to measure the interface pressure. Data was acquired over a time of 20 minutes preceded by 6 minutes settling time to reduce measurement error. Qualitative information regarding participants’ opinion on pain and comfort was recorded using a questionnaire. Data analysis was performed using SPSS 22. Results: Data was collected from 30 participants aged 19 to 51 (mean 25.77, SD 7.72), BMI from 18.7 to 33.6 (mean 24.12, SD 3.29), for two surfaces, following eight participant exclusions due to technical faults. Total average pressure, average pressure for jeopardy areas (head, sacrum & heels) and peak pressure for jeopardy areas were calculated as interface pressure in mmHg. Qualitative data showed that a significant difference in experiences of comfort and pain was found in the jeopardy areas (P<0.05) between the two surfaces. Conclusion: A significant difference is seen in average pressure between the two surfaces. Pain and comfort data also show a significant difference between the surfaces, both findings support the proposal for further investigation into the effects of radiological surfaces as a risk factor for the formation of pressure ulcers.
Resumo:
Introdução – A pesquisa de informação realizada pelos estudantes de ensino superior em recursos eletrónicos não corresponde necessariamente ao domínio de competências de pesquisa, análise, avaliação, seleção e bom uso da informação recuperada. O conceito de literacia da informação ganha pertinência e destaque, na medida em que abarca competências que permitem reconhecer quando é necessária a informação e de atuar de forma eficiente e efetiva na sua obtenção e utilização. Objetivo – A meta da Escola Superior de Tecnologia da Saúde de Lisboa (ESTeSL) foi a formação em competências de literacia da informação, fora da ESTeSL, de estudantes, professores e investigadores. Métodos – A formação foi integrada em projetos nacionais e internacionais, dependendo dos públicos-alvo, das temáticas, dos conteúdos, da carga horária e da solicitação da instituição parceira. A Fundação Calouste Gulbenkian foi o promotor financeiro privilegiado. Resultados – Decorreram várias intervenções em território nacional e internacional. Em 2010, em Angola, no Instituto Médio de Saúde do Bengo, formação de 10 bibliotecários sobre a construção e a gestão de uma biblioteca de saúde e introdução à literacia da informação (35h). Em 2014, decorrente do ERASMUS Intensive Programme, o OPTIMAX (Radiation Dose and Image Quality Optimisation in Medical Imaging) para 40 professores e estudantes de radiologia (oriundos de Portugal, Reino Unido, Noruega, Países Baixos e Suíça) sobre metodologia e pesquisa de informação na MEDLINE e na Web of Science e sobre o Mendeley, enquanto gestor de referências (4h). Os trabalhos finais deste curso foram publicados em formato de ebook (http://usir.salford.ac.uk/34439/1/Final%20complete%20version.pdf), cuja revisão editorial foi da responsabilidade dos bibliotecários. Ao longo de 2014, na Escola Superior de Educação, Escola Superior de Dança, Instituto Politécnico de Setúbal e Faculdade de Medicina de Lisboa e, ao longo de 2015, na Universidade Aberta, Escola Superior de Comunicação Social, Instituto Egas Moniz, Faculdade de Letras de Lisboa e Centro de Linguística da Universidade de Lisboa foram desenhados conteúdos sobre o uso do ZOTERO e do Mendeley para a gestão de referências bibliográficas e sobre uma nova forma de fazer investigação. Cada uma destas sessões (2,5h) envolveu cerca de 25 estudantes finalistas, mestrandos e professores. Em 2015, em Moçambique, no Instituto Superior de Ciências da Saúde, decorreu a formação de 5 bibliotecários e 46 estudantes e professores (70h). Os conteúdos ministrados foram: 1) gestão e organização de uma biblioteca de saúde (para bibliotecários); 2) literacia da informação: pesquisa de informação na MEDLINE, SciELO e RCAAP, gestores de referências e como evitar o plágio (para bibliotecários e estudantes finalistas de radiologia). A carga horária destinada aos estudantes incluiu a tutoria das monografias de licenciatura, em colaboração com mais duas professoras do projeto. Para 2016 está agendada formação noutras instituições de ensino superior nacionais. Perspetiva-se, ainda, formação similar em Timor-Leste, cujos conteúdos, datas e carga horária estão por agendar. Conclusões – Destas iniciativas beneficia a instituição (pela visibilidade), os bibliotecários (pelo evidenciar de competências) e os estudantes, professores e investigadores (pelo ganho de novas competências e pela autonomia adquirida). O projeto de literacia da informação da ESTeSL tem contribuído de forma efetiva para a construção e para a produção de conhecimento no meio académico, nacional e internacional, sendo a biblioteca o parceiro privilegiado nesta cultura de colaboração.
Resumo:
Dissertation to Obtain the Degree of Master in Biomedical Engineering
Resumo:
There is no paucity of methods for diagnosing Cryptosporidium spp. infection. The merits of immunoassays notwithstanding, microscopic identification of Cryptosporidium spp. oocysts in fecal samples remains an important diagnostic procedure. It owes the persistence of its use to such characteristics as dispensing with expensive equipment and kits, requiring only basic laboratory facilities, and having a low probability of false positive results when permanent slides are prepared, which can be re-examined in case of doubt. Cryptosporidium spp. oocysts can be readily identified in fecal smears prepared according to a regressive iron hematoxylin staining technique. The number of steps and their duration, as well as costs, were reduced to a minimum without loss of image quality and permanence of the preparations.
Resumo:
Neste trabalho foi desenvolvido um estudo detalhado dos equipamentos de imagiologia médica, que recorrem ao uso de radiação-X, bem como da ressonância magnética. No seguimento deste estudo foram realizadas diversas atividades com equipamentos reais, desde instalações, reparações, manutenções, até ao seu desmantelamento. Este tipo de atividade permitiu ter uma melhor perceção do funcionamento de cada equipamento e o tipo de trabalho que é realizado por um engenheiro eletrotécnico na PHILIPS no sector healthcare. Durante estas atividades foi possível fazer um estudo da qualidade de imagem, em termos de fatores geométricos, em que foi estudada a distorção, a ampliação e a penumbra de uma imagem. Todos estes parâmetros foram alvos de estudo de forma a poder obter imagens com grande qualidade, mas sem que seja comprometida a saúde do doente, devido à elevada exposição de radiação que corpo humano pode absorver. Este estudo tem como intuito perceber como é que a variação de certos parâmetros irá alterar a qualidade da imagem. Desta forma pretende-se perceber como podem ser calibrados os equipamentos de diagnóstico por imagem, para que o técnico de diagnóstico e terapêutica apenas tenha de indicar qual a parte do corpo humano a radiografar, sendo que a máquina se coloca automaticamente nos parâmetros pré-definidos sem qualquer intervenção humana.
Resumo:
Computação gráfica um campo que tem vindo a crescer bastante nos últimos anos, desde áreas como cinematográficas, dos videojogos, da animação, o avanço tem sido tão grande que a semelhança com a realidade é cada vez maior. Praticamente hoje em dia todos os filmes têm efeitos gerados através de computação gráfica, até simples anúncios de televisão para não falar do realismo dos videojogos de hoje. Este estudo tem como objectivo mostrar duas alternativas no mundo da computação gráfica, como tal, vão ser usados dois programas, Blender e Unreal Engine. O cenário em questão será todo modelado de raiz e será o mesmo nos dois programas. Serão feitos vários renders ao cenário, em ambos os programas usando diferentes materiais, diferentes tipos de iluminação, em tempo real e não de forma a mostrar as várias alternativas possíveis.
Resumo:
Multifocal intraocular lenses (MF IOLs) have concentric optical zones with different dioptric power, enabling patients to have good visual acuity at multiple focal points. However, several optical limitations have been attributed to this particular design. The purpose of this study is to access the effect of MF IOLs design on the accuracy of retinal optical coherence tomography (OCT). Cross-sectional study conducted at the Refractive Surgery Department of Central Lisbon Hospital Center. Twenty-three eyes of 15 patients with a diffractive MF IOL and 27 eyes of 15 patients with an aspheric monofocal IOL were included in this study. All patients underwent OCT macular scans using Heidelberg Spectralis®. Macular thickness and volume values and image quality (Q factor) were compared between the two groups. There were no statistically significant differences between both groups regarding macular thickness or volume measurements. Retinal OCT image quality was significantly lower in the MF IOL group (p < 0.01). MF IOLs are associated with a significant decrease in OCT image quality. However, this fact does not seem to compromise the accuracy of spectral domain OCT retinal measurements.
Resumo:
Dissertation presented at Faculdade de Ciências e Tecnologia Universidade Nova de Lisboa to obtain a Master Degree in Biomedical Engineering
Resumo:
RESUMO: Apesar de toda a evolução farmacológica e de meios complementares de diagnóstico possível nos últimos anos, o enfarte agudo do miocárdio e a morte súbita continuam a ser a primeira manifestação da aterosclerose coronária para muitos doentes, que estavam previamente assintomáticos. Os exames complementares de diagnóstico tradicionalmente usados para avaliar a presença de doença coronária, baseiam‐se na documentação de isquémia do miocárdio e por este motivo a sua positividade depende da presença de lesões coronárias obstrutivas. As lesões coronárias não obstrutivas estão também frequentemente implicadas no desenvolvimento de eventos coronários. Apesar de o risco absoluto de instabilização por placa ser superior para as lesões mais volumosas e obstrutivas, estas são menos prevalentes do que as placas não obstrutivas e assim, por questões probabilísticas, os eventos coronários resultam com frequência da rotura ou erosão destas últimas. Estudos recentes de imagiologia intracoronária avançada forneceram evidência de que apesar de ser possível identificar algumas características de vulnerabilidade em placas associadas ao desenvolvimento subsequente de eventos coronários, a sua sensibilidade e especificidade é muito baixa para aplicação clínica. Mais do que o risco associado a uma placa em particular, para o doente poderá ser mais importante o risco global da sua árvore coronária reflexo da soma das probabilidade de todas as suas lesões, sendo que quanto maior for a carga aterosclerótica maior será o seu risco. A angio TC cardíaca é a mais recente técnica de imagem não invasiva para o estudo da doença coronária e surgiu nos últimos anos fruto de importantes avanços na tecnologia de TC multidetectores. Estes avanços, permitiram uma progressiva melhoria da resolução espacial e temporal, contribuindo para a melhoria da qualidade dos exames, bem como uma significativa redução da dose de radiação. A par desta evolução tecnológica, foi aumentando a experiência e gerada mais evidência científica, tornando a angio TC cardíaca cada vez mais robusta na avaliação da doença coronária e aumentando a sua aplicabilidade clínica. Mais recentemente apareceram vários trabalhos que validaram o seu valor prognóstico, assinalando a sua chegada à idade adulta. Para além de permitir excluir a presença de doença coronária e de identificar a presença de estenoses significativas, a angio TC cardíaca permite identificar a presença de lesões coronárias não obstrutivas, característica impar desta técnica como modalidade de imagem não invasiva. Ao permitir identificar a totalidade das lesões ateroscleróticas (obstrutivas e não obstrutivas), a 18 angio TC cardíaca poderá fornecer uma quantificação da carga aterosclerótica coronária total, podendo essa identificação ser útil na estratificação dos indivíduos em risco de eventos coronários. Neste trabalho foi possível identificar preditores demográficos e clínicos de uma elevada carga aterosclerótica coronária documentada pela angioTC cardíaca, embora o seu poder discriminativo tenha sido relativamente modesto, mesmo quando agrupados em scores clínicos. Entre os vários scores, o desempenho foi um pouco melhor para o score de risco cardiovascular Heartscore. Estas limitações espelham a dificuldade de prever apenas com base em variáveis clínicas, mesmo quando agrupadas em scores, a presença e extensão da doença coronária. Um dos factores de risco clássicos, a obesidade, parece ter uma relação paradoxal com a carga aterosclerótica, o que pode justificar algumas limitações da estimativa com base em scores clínicos. A diabetes mellitus, por outro lado, foi um dos preditores clínicos mais importantes, funcionando como modelo de doença coronária mais avançada, útil para avaliar o desempenho dos diferentes índices de carga aterosclerótica. Dada a elevada prevalência de placas ateroscleróticas identificáveis por angio TC na árvore coronária, torna-‐se importante desenvolver ferramentas que permitam quantificar a carga aterosclerótica e assim identificar os indivíduos que poderão eventualmente beneficiar de medidas de prevenção mais intensivas. Com este objectivo, foi desenvolvido um índice de carga aterosclerótica que reúne a informação global acerca da localização, do grau de estenose e do tipo de placa, obtida pela angio TC cardíaca, o CT--‐LeSc. Este score poderá vir a ser uma ferramenta útil para quantificação da carga aterosclerótica coronária, sendo de esperar que possa traduzir a informação prognóstica da angio TC cardíaca. Por fim, o conceito de árvore coronária vulnerável poderá ser mais importante do que o da placa vulnerável e a sua identificação pela angio TC cardíaca poderá ser importante numa estratégia de prevenção mais avançada. Esta poderá permitir personalizar as medidas de prevenção primária, doseando melhor a sua intensidade em função da carga aterosclerótica, podendo esta vir a constituir uma das mais importantes indicações da angio TC cardíaca no futuro.---------------- ABSTRACT Despite the significant advances made possible in recent years in the field of pharmacology and diagnostic tests, acute yocardial infarction and sudden cardiac death remain the first manifestation of coronary atherosclerosis in a significant proportion of patients, as many were previously asymptomatic. Traditionally, the diagnostic exams employed for the evaluation of possible coronary artery disease are based on the documentation of myocardial ischemia and, in this way, they are linked to the presence of obstructive coronary stenosis. Nonobstructive coronary lesions are also frequently involved in the development of coronary events. Although the absolute risk of becoming unstable per plaque is higher for more obstructive and higher burden plaques, these are much less frequent than nonobstructive lesions and therefore, in terms of probability for the patient, coronary events are often the result of rupture or erosion of the latter ones. Recent advanced intracoronary imaging studies provided evidence that although it is possible to identify some features of vulnerability in plaques associated with subsequente development of coronary events, the sensitivity and sensibility are very limited for clinical application. More important than the individual risk associated with a certain plaque, for the patient it might be more important the global risk of the total coronary tree, as reflected by the sum of the diferent probabilities of all the lesions, since the higher the coronary Atherosclerotic burden, the higher the risk for the patient. Cardiac CT or Coronary CT angiography is still a young modality. It is the most recente noninvasive imaging modality in the study of coronary artery disease and its development was possible due to important advances in multidetector CT technology. These allowed significant improvements in temporal and spatial resolution, leading to better image quality and also some impressive reductions in radiation dose. At the same time, the increasing experience with this technique lead to a growing body of scientific evidence, making cardiac CT a robust imaging tool for the evaluation of coronary artery disease and increased its clinical indications. More recently, several publications documented its prognostic value, marking the transition of cardiac CT to adulthood. Besides being able to exclude the presence of coronary artery disease and of obstructive lesions, Cardiac CT allows also the identification of nonobstructive lesions, making this a unique tool in the field of noninvasive imaging modalities. By evaluating both obstructive and nonobstructive lesions, cardiac CT can provide for the quantification of total coronary atherosclerotic burden, and this can be useful to stratify the risk of future coronary events. In the present work, it was possible to identify significant demographic and clinical predictors of a high coronary atherosclerotic burden as assessed by cardiac CT, but with modest odds ratios, even when the individual variables were gathered in clinical scores. Among these diferent clinical scores, the performance was better for the Heartscore, a cardiovascular risk score. This modest performance underline the limitations on predicting the presence and severity of coronary disease based only on clinical variables, even when optimized together in risk scores, One of the classical risk factors, obesity, had in fact a paradoxical relation with coronary atherosclerotic burden and might explain some of the limitations of the clinical models. On the opposite, diabetes mellitus was one of the strongest clinical predictors, and was considered to be a model of more advanced coronary disease, useful to evaluate the performance of diferent plaque burden scores. In face of the high prevalence of plaques that can be identified in the coronary tree of patients undergoing cardiac CT, it is of utmost importance to develop tools to quantify the total coronary atherosclerotic burden providing the identification of patients that could eventually benefit from more intensive preventive measures. This was the rational for the development of a coronary atherosclerotic burden score, reflecting the comprehensive information on localization, degree of stenosis and plaque composition provided by cardiac CT – the CT-LeSc. This score may become a useful tool to quantify total coronary atherosclerotic burden and is expected to convey the strong prognostic information of cardiac CT. Lastly, the concept of vulnerable coronary tree might become more important than the concept of the vulnerable plaque and his assessment by cardiac CT Might become important in a more advance primary prevention strategy. This Could lead to a more custom-made primary prevention, tailoring the intensity of preventive measures to the atherosclerotic burden and this might become one of the most important indications of cardiac CT In the near future.