998 resultados para IgG anti-IgE
Resumo:
A serological follow-up study was carried out on 27 children (1–12 years old) with visceral and/or ocular toxocariasis, after treatment with thiabendazole. A total of 159 serum samples were collected in a period ranging from 22–116 months. Enzyme-linked immunosorbent assays (IgG, IgA, and IgE ELISA) were standardized, using excretory–secretory antigens obtained from the second-stage larvae of a Toxocara canis culture. The sensitivity found for the IgG, IgA, and IgE ELISA, as determined in visceral toxocariasis patients, was 100%, 47.8%, and 78.3%, respectively. Approximately 84% of the patients presented single or multiple parasitosis, as diagnosed by stool examination, yet such variables did not appear to affect the anti-Toxocara immune response. Titers of specific IgE antibody showed a significant decrease during the first year after treatment, followed by a decrease in the IgA titers in the second year, and in the IgG titers from the fourth year onwards. Sera from all patients presented high avidity IgG antibodies, indicating that they were in the chronic phase of the disease. Moreover, 1 year after treatment, the level of leukocytes, eosinophils, and anti-A isohemagglutinin in patients decreased significantly. The present data suggest that IgE antibodies plus eosinophil counts are helpful parameters for patient followup after chemotherapy.
Resumo:
Two humanized monoclonal antibody constructs bearing the same variable regions of an anti-CD3 monoclonal antibody, whole IgG and FvFc, were expressed in CHO cells. Random and site-specific integration were used resulting in similar expression levels. The transfectants were selected with appropriate selection agent, and the surviving cells were plated in semi-solid medium for capture with FITC-conjugated anti-human IG antibody and picked with the robotic ClonePix FL. Conditioned media from selected clones were purified by affinity chromatography and characterized by SDS-PAGE, Western-blot, SEC-HPLC, and isoelectric focusing. Binding to the target present in healthy human mononuclear cells was assessed by flow cytometry, as well as by competition between the two constructs and the original murine monoclonal antibody. The humanized constructs were not able to dislodge the murine antibody while the murine anti-CD3 antibody could dislodge around 20% of the FvFc or IgG humanized versions. Further in vitro and in vivo pre-clinical analyses will be carried out to verify the ability of the humanized versions to demonstrate the immunoregulatory profile required for a humanized anti-CD3 monoclonal antibody.
Resumo:
Total serum IgE, and Strongyloides - specific IgG and IgA antibodies were studied in 27 patients with parasitologically proven strongyloidiasis. Clinical manifestations in this case series were investigated by a restrospective study of the patient's records. Total serum IgE levels were elevated (greater than 250 IU/ml) in 59% of the patients (mean concentration = 1364 IU/ml). Parasite - specific IgG and IgA antibodies were detected by ELISA in the serum of 23 (85.2%) and 21 (77.8%) patients, respectively. Elevated serum IgE and clinical manifestations were not useful indexes of the presence of strongyloidiasis. On the other hand, our results support the view that serologic tests, particularly ELISA for detecting Strongyloides - specific IgG antibodies, can be usefully exploited for diagnostic purposes in strongyloidiasis.
Resumo:
For the purpose of research a large quantity of anti-measles IgG working reference serum was needed. A pool of sera from five teenagers was prepared and named Alexandre Herculano (AH). In order to calibrate the AH serum, 18 EIA assays were performed testing in parallel AH and the 2nd International Standard 1990, Anti-Measles Antibody, 66/202 (IS) in a range of dilutions (from 1/50 to 1/25600). A method which compared parallel lines resulting from the graphic representation of the results of laboratory tests was used to estimate the power of AH relative to IS. A computer programme written by one of the authors was used to analyze the data and make potency estimates. Another method of analysis was used, comparing logistic curves relating serum concentrations with optical density by EIA. For that purpose an existing computer programme (WRANL) was used. The potency of AH relative to IS, by either method, was estimated to be 2.4. As IS has 5000 milli international units (mIU) of anti-measles IgG per millilitre (ml), we concluded that AH has 12000 mIU/ml.
Resumo:
The circumoval precipitin test (COPT), enzyme-linked immunosorbent assay (ELISA) and the immunoblotting anti-adult worm antigen (AWA) and soluble egg antigen (SEA) tests were applied to 17 chronically schistosome-infected patients for the detection of anti-Schistosoma mansoni antibodies before and on four occasions after oxamniquine administration over a period of six months. Compared to a control group, schistosomiasis patients showed high levels of IgG antibodies in AWA and SEA-ELISA. A decrease in IgG levels was observed six months after treatment, although negative reactions were not obtained. Significant decreases in IgG1, IgG3 and, mainly, IgG4, but not anti-SEA IgG2 levels were observed six months after treatment, again without negativity. Analysis of anti-AWA IgG antibodies by immunoblotting before treatment showed a 31 kDa strand in 14 patients (82%) which disappeared in three cases up to six months after treatment; furthermore, anti-SEA IgG antibodies showed the same band in nine patients (53%) before treatment, which disappeared in only four cases up to six months after treatment.
Resumo:
The prevalence of anti-human parvovirus B19 IgG antibodies was determined in sera from 165 chronic hemolytic anemia patients, receiving medical care at Instituto Estadual de Hematologia (IEHE), Rio de Janeiro, during the year of 1994. This sample represents around 10% of the chronic hemolytic anemia patients attending at IEHE. Most of these patients (140) have sickle cell disease. Anti-B19 IgG antibodies were detected in 32.1% of patients. No statistically significant difference (p > 0.05) was seen between IgG antibody prevalence in male (27.8%) and female (35.5%) patients. Anti-B19 IgG antibodies were more frequent in older (37.6%) than younger (28.2%) than 20 years old patients, although this difference had no statistical significance (p > 0.05). Anti-B19 IgG antibody prevalence showed that 67.9% of patients enrolled in the study were susceptible to B19 acute infection. With the aim to detect acute B19 infection, patients follow up continued until February 1996. During this period four patients presented transient aplastic crisis due to human parvovirus B19 as confirmed by the detection of specific IgM antibodies. All four patients were younger than 20 years old, and 3 were younger than 10 years old. Three of them were sickle cell disease patients. Three of the four acute B19 infection occurred during 1994 springtime.
Resumo:
Strongyloides ratti larval extract was used for the standardization of ELISA to detect genus-specific IgE in human strongyloidiasis. Forty serum samples from monoinfected patients shedding S. stercoralis larvae (Group I), 40 from patients with other intestinal parasites (Group II), and 40 from copronegative healthy subjects (Group III) were analyzed. Genus-specific IgE levels (ELISA Index: EI) were significantly higher in the group I (EI = 1.43) than groups II (EI = 0.70) and III (EI = 0.71), showing positivity rates of 55%, 2.5% and 0%, respectively. Similarly, sera from copropositive patients had significantly higher levels of total IgE (866 IU/mL) as compared to those from group II (302 IU/mL) and III (143 IU/mL). A significant positive correlation was found between levels of Strongyloides specific-IgE and total IgE in sera from patients with strongyloidiasis. In conclusion, S. ratti heterologous extract showed to be a useful tool for detecting genus-specific IgE by ELISA, contributing for a better characterization of the immune response profile in human strongyloidiasis.
Resumo:
A total of 354 serum samples from inhabitants who frequent the Clinical Laboratory in Catalão, Goiás, in the central-western region of Brazil, were collected from June to August, 2002. The samples were evaluated by indirect immunofluorescence antibody tests and an enzyme linked immunosorbent assay in order to detect anti-Taenia solium metacestode IgG antibodies. Reactive and inconclusive samples were tested by Western blotting (WB). Considering WB as a confirmation, the frequency of antibodies in the serum samples of the above population was 11.3% (CI 5.09 - 17.51). The immunodominant bands most frequently recognized in WB were 64-68 kDa (97.5%) and 47-52 kDa (80%). The percentage of seropositivity to cysticercosis was significantly higher for individuals residing in areas without sewage systems (p < 0.0001). In conclusion, the results indicate a probable endemic situation of cysticercosis in this population. These results reinforce the urgent need for control and prevention measures to be taken by the local public health services.
Resumo:
With the emergence of the human immunodeficiency virus (HIV), in patients with acquired immunodeficiency syndrome (AIDS), Toxoplasma gondii has arisen as an important opportunist pathogenic agent, especcially in the central nervous system, being the most common cause of intracerebral lesions. The incidence of Toxoplasma gondii in HIV-infected patients depends principally on the existence of latent Toxoplasma parasitosis in the population affected. Through the enzyme-linked immunosorbent assay (ELISA), IgG and IgM anti-Toxoplasma antibodies were found in 92 patients of which 46 (50.0%) were IgG seropositive, and only one case (1.0%) had IgM antibodies.Of the 92 patients: 53 were HIV seropositives and 39 had AIDS. The detection and monitoring of anti-Toxoplasma antibodies in HIV patients is essential, since in this group there is a high percentage risk of developing cerebral toxoplasmosis, which is the second cause of death in this type of patients.
Resumo:
O presente trabalho avaliou o perfil de anticorpos em amostras de soro de 37 pacientes com diagnóstico clínico confirmado ou compatível com leishmaniose tegumentar americana atendidos no Hospital de Clínicas da Universidade Federal de Uberlândia, MG. Os perfis das classes de imunoglobulinas e subclasses de IgG foram analisados pelo teste ELISA indireto, utilizando-se antígeno solúvel de Leishmania (Leishmania) amazonensis. A avidez dos anticorpos foi determinada pelo tratamento com uréia a 6 M, após incubação dos soros com o antígeno. Observou-se que 97%, 94,6%, 57,5 e 21,5% das amostras testadas apresentaram anticorpos anti-Leishmania das classes IgE, IgG, IgA e IgM, respectivamente e, os perfis das subclasses de IgG demonstraram, IgG1>IgG3>IgG2>IgG4. Os anticorpos IgE anti-Leishmania de alta avidez corresponderam a 44,4%. Por outro lado, IgG e IgA anti-Leishmania foram em sua maioria (62,8 e 47,8%, respectivamente), de média avidez. A variação do perfil de isotipos, bem como a avidez das imunoglobulinas refletiu a complexidade da resposta imune humoral contra a leishmaniose tegumentar americana.
Resumo:
INTRODUCTION: The goal was to develop an in-house serological method with high specificity and sensitivity for diagnosis and monitoring of Chagas disease morbidity. METHODS: With this purpose, the reactivities of anti-T. cruzi IgG and subclasses were tested in successive serum dilutions of patients from Berilo municipality, Jequitinhonha Valley, Minas Gerais, Brazil. The performance of the in-house ELISA was also evaluated in samples from other relevant infectious diseases, including HIV, hepatitis C (HCV), syphilis (SYP), visceral leishmaniasis (VL), and American tegumentary leishmaniasis (ATL), and noninfected controls (NI). Further analysis was performed to evaluate the applicability of this in-house methodology for monitoring Chagas disease morbidity into three groups of patients: indeterminate (IND), cardiac (CARD), and digestive/mixed (DIG/Mix), based on their clinical status. RESULTS: The analysis of total IgG reactivity at serum dilution 1:40 was an excellent approach to Chagas disease diagnosis (100% sensitivity and specificity). The analysis of IgG subclasses showed cross-reactivity, mainly with NI, VL, and ATL, at all selected serum dilutions. Based on the data analysis, the IND group displayed higher IgG3 levels and the DIG/Mix group presented higher levels of total IgG as compared with the IND and CARD groups. CONCLUSIONS: These findings demonstrated that methodology presents promising applicability in the analysis of anti-T. cruzi IgG reactivity for the differential diagnosis and evaluation of Chagas disease morbidity.
Resumo:
Herpes simplex ocular infection is a major cause of corneal blindness. Local antiviral treatments exist but are associated with corneal toxicity, and resistance has become an issue. We evaluated the biodistribution and efficacy of a humanized anti-herpes simplex virus (anti-HSV) IgG FAb fragment (AC-8; 53 kDa) following repeated topical administration. AC-8 was found in the corneal epithelium, anterior stroma, subepithelial stromal cells, and retinal glial cells, with preferential entry through the ocular limbus. AC-8 was active against 13 different strains of HSV-1, with 50% and 90% mean effective concentrations (MEC(50) and MEC(90), respectively) ranging from 0.03 to 0.13 μg/ml, indicating broad-spectrum activity. The in vivo efficacy of AC-8 was evaluated in a mouse model of herpes-induced ocular disease. Treatment with low-dose AC-8 (1 mg/ml) slightly reduced the ocular disease scores. A greater reduction of the disease scores was observed in the 10-mg/ml AC-8-treated group, but not as much as with trifluridine (TFT). AC-8 treatment reduced viral titers but less than trifluridine. AC-8 did not display any toxicity to the cornea or other structures in the eye. In summary, topical instillation of an anti-HSV FAb can be used on both intact and ulcerated corneas. It is well tolerated and does not alter reepithelialization. Further studies to improve the antiviral effect are needed for AC-8 to be considered for therapeutic use.
Resumo:
Introduction Quatre génotypes pathogènes de l'hépatite E (HEV) sont actuellement connus. Ils présentent des caractéristiques épidémiologiques différentes. Les génotypes 1 et 2 infectent uniquement l'homme et sont à l'origine d'épidémies dans des pays en voie de développement. Les génotypes 3 et 4 se présentent sous forme de zoonose, endémiques chez des cochons et autres mammifères dans des pays industrialisés. Ces derniers génotypes sont à l'origine de cas sporadiques d'hépatite E autochtones. La majorité des tests de sérologie actuellement commercialisés se basent sur des virus de génotype 1 et 2. Le bénéfice de l'utilisation d'un test sérologique basé sur le génotype 3 dans des pays industrialisés n'a pas été étudié jusqu'à présent. Dans cette étude, les performances de tests sérologiques basés sur des antigènes de plusieurs génotypes de l'HEV ont été comparées. Méthode Les tests ont été appliqués à deux populations distinctes: une population de 20 patients, chez qui une infection aiguë d'hépatite E, génotype 3, a été documentée par PCR sanguine, et une population de 550 donneurs de sang de la région de Lausanne. Le dépistage des IgGs anti-HEV a été effectué dans le sérum des deux populations par trois «Enzyme Immuno Assays» (EIA) à savoir MP Diagnostics, Dia.Pro et Fortress. Les échantillons positifs avec au moins un des EIA ont été testés par un «Immunodot Assay», le recomLine HEV IgG/IgM. Tous les EIA sont basés sur des antigènes des génotypes 1 et 2, alors que l'immunodot se base sur des antigènes des génotypes 1 et 3. Résultats Tous les échantillons des cas d'hépatite E documentés et 124 sur 550 échantillons des donneurs de sang étaient positifs avec au moins un des tests sérologique. Parmi les cas confirmés par PCR, 45 %, 65 %, 95 % et 55 % étaient respectivement positifs avec le test de MP Diagnostics, Dia.Pro, Fortress et recomLine. Parmi les échantillons positifs des donneurs de sang avec au moins un des tests, 120/124 (97 %) étaient positifs avec le test Fortress, 19/124 (15 %) étaient positifs avec tous les EIA et 51/124 (41 %) étaient positifs avec le recomLine. Parmi les cas d'hépatite E confirmés, 11/20 (55 %) étaient positifs avec le recomLine et parmi ceux-ci, une réactivité plus forte pour le génotype 3 était observée dans 1/11 (9 %) et une réactivité identique dans 5/11 (45.5 %) cas. Conclusions Même si le recomLine contient des protéines dérivées de l'HEV génotype 3, sa sensibilité est inférieure à l'EIA de Fortress dans les cas d'hépatite E aiguë de génotype 3. De plus, chez environ 45 % des patients, le recomLine ne parvient pas à identifier une infection comme étant causé par un virus du génotype 3. Dans la population de donneurs de sang, nous avons observe de grandes variations dans les séroprévalences mesurées, allant de 4.2 % à 21.8 % selon les tests sérologiques employés.
Resumo:
BACKGROUND: The benefit of using serological assays based on HEV genotype 3 in industrialised settings is unclear. We compared the performance of serological kits based on antigens from different HEV genotypes. METHODS: Taking 20 serum samples from patients in southwest France with acute HEV infection (positive PCR for HEV genotype 3) and 550 anonymised samples from blood donors in southwest Switzerland, we tested for anti-HEV IgG using three enzyme immunoassays (EIAs) (MP Diagnostics, Dia.Pro and Fortress) based on genotype 1 and 2 antigens, and one immunodot assay (Mikrogen Diagnostik recomLine HEV IgG/IgM) based on genotype 1 and 3 antigens. RESULTS: All acute HEV samples and 124/550 blood donor samples were positive with ≥1 assay. Of PCR-confirmed patient samples, 45%, 65%, 95% and 55% were positive with MP Diagnostics, Dia.Pro, Fortress and recomLine, respectively. Of blood donor samples positive with ≥1 assay, 120/124 (97%), were positive with Fortress, 19/124 (15%) were positive with all EIAs and 51/124 (41%) were positive with recomLine. Of 11/20 patient samples positive with recomLine, stronger reactivity for HEV genotype 3 was observed in 1/11(9%), and equal reactivity for both genotypes in 5/11 (45.5%). CONCLUSIONS: Although recomLine contains HEV genotype 3, it has lower sensitivity than Fortress in acute HEV infection and fails to identify infection as being due to this genotype in approximately 45% of patients. In our single blood donor population, we observe wide variations in measured seroprevalence, from 4.2% to 21.8%, depending on the assay used.