897 resultados para Human samples


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study was conducted to measure the levels of 23 PCB congeners and 6 organochlorine pesticides (OCPs) in human milk and three food types collected from Luqiao and Pingqiao in Zhejiang Province, China. An effort was also made to explore the potential health risk for the mothers and breast-fed infants living in these two localities. Luqiao was selected as the sampling site because it is the largest place for the disassembly of obsolete transformers and electrical waste in China. Pingqiao, located 100 kin NW of Luqiao, is not known to be a place for any electronic or electrical waste and hence was chosen as the control site. Both localities are important agricultural places in the province. The organochlorines were measured in the samples using the GC-PECD technique. Micro-EROD bioassay method was also used as a complement of the chemical analysis to estimate the TEQ levels of dioxin-like PCBs in human milk. The data showed that the human milk, rice, hen egg, and fish samples from Luqiao were more heavily contaminated with PCBs than those from Pingqiao, suggesting that the mothers and their breast-fed infants in Luqiao tended to receive greater exposure to PCBs than those living in Pingqiao. The OCP levels in the two localities were found comparable, suggesting that the major source of contamination with these pesticides was from their agricultural uses. Significant correlation (R-2 = 0.87, P < 0.001) of PCB TEQs was found between the bioassay and chemical analysis method, suggesting that micro-EROD is an effective method for comprehensive determination of TEQ levels in human milk. Comparison with literature data showed that the PCB levels in milk samples from Luqiao were significantly higher than those from localities in other Chinese provinces and comparable to those in developed or industrialized countries. (c) 2007 Published by Elsevier B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

So far, little is known on the distribution of hepatotoxic microcystin (MC) in various organs of bivalves, and there is no study on MC accumulation in bivalves from Chinese waters. Distribution pattern and seasonal dynamics of MC-LR, -YR and -RR in various organs (hepatopancreas, intestine, visceral mass, gill, foot, and rest) of four edible freshwater mussels (Anodonta woodiana, Hyriopsis cumingii, Cristaria plicata, and Lamprotula leai) were studied monthly during Oct. 2003-Sep. 2004 in Lake Taihu with toxic cyanobacterial blooms in the summer. Qualitative and quantitative determinations of MCs in the organs were done by LC-MS and HPLC. The major toxins were present in the hepatopancreas (45.5-55.4%), followed by visceral mass with substantial amount of gonad (27.6-35.5%), whereas gill and foot were the least (1.8-5.1%). The maximum MC contents in the hepatopancreas, intestine, visceral mass, gill, foot, and rest were 38.48, 20.65, 1.70, 0.64, 0.58, and 0.61 mu g/g DW, respectively. There were rather good positive correlation in MC contents between intestines and hepatopancreas of the four bivalves (r = 0.75-0.97, p < 0.05). There appeared to be positive correlations between the maximum MC content in the hepatopancreas and the delta(13)C (r = 0.919) or delta(15)N (r = 0.878) of the foot, indicating that the different MC content in the hepatopancreas might be due to different food ingestion. A glutathione (GSH) conjugate of MC-LR was also detected in the foot sample of C. plicata. Among the foot samples analyzed, 54% were above the provisional WHO tolerable daily intake (TDI) level, and the mean daily intakes from the four bivalves were 8-23.5 times the TDI value when the bivalves are eaten as a whole, suggesting the high risk of consuming bivalves in Lake Taihu. (C) 2005 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The H4IIE rat hepatoma cell line was employed as a cell model to screen 7-ethoxyresorufin O-deethylase (EROD)-TCDD equivalents (EROD-TEQ) of human breast milk samples collected from Hong Kong and Guangzhou, China. The screening methods employed a 96-well plate spectrofluorometer-EROD assay. For cell-line validation, our results demonstrated a dose-dependent increase in the Ah receptor-mediated response (i.e., CYP1A1 mRNA and EROD) of the cells upon exposure to a number of known Ah receptor agonists, including 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD), 2,3,7,8-tetrachlorodibenzothiophene, benzo[a]pyrene, and beta-naphthaflavone. TCDD induced CYP1A1 mRNA and EROD was in a close positive correlation (r = 0.98). For the screening of dioxin-like compounds, breast milk samples collected during lactation weeks 3-5 were used. One hundred (from Hong Kong) and 48 (from Guangzhou) breast milk samples were assayed, of which 65% and 68% of the samples, respectively, showed detectable dioxin-like activities using the H4IIE cell EROD screening method. For sixty-five samples from Hong Kong the mean EROD-TEQ values ranged from 58.1 to 96.5 pg/g of milk fat for those aged 21-36 years while 32 samples from Guangzhou had mean values of 98.8-202.1 pg/g of milk fat. In comparisons of the EROD-TEQ values for different age groups from both cities, there were no significant differences (P < 0.05). However, the mean and median EROD-TEQ values of the Guangzhou population were in general higher than those of the Hong Kong population. The results of the present study indicate that it is feasible to use the H4IIE cell-line as a model for screening dioxin-like compounds in human breast milk. In addition, the method is rapid and cost-effective, particularly for a routine and high-throughput sample screening analysis, compared to the costly and time-intensive chemical analytical techniques. (C) 2003 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We investigated the effects of Ginsenoside R-e on human sperm motility in fertile and asthenozoospermic infertile individuals in vitro and the mechanism by which the Ginsenosides play their roles. The semen samples were obtained from 10 fertile volunteers and 10 asthenozoospermic infertile patients. Spermatozoa were separated by Percoll and incubated with 0, 1, 10 or 100 mu M of Ginsenoside R-e. Total sperm motility and progressive motility were measured by computer-aided sperm analyzer (CASA). Nitric oxide synthase (NOS) activity was determined by the H-3-arginine to H-3-citrulline conversion assay, and the NOS protein was examined by the Western blot analysis. The production of sperm nitric oxide (NO) was detected using the Griess reaction. The results showed that Ginsenoside R-e significantly enhanced both fertile and infertile sperm motility, NOS activity and NO production in a concentration-dependent manner. Sodium nitroprusside (SNP, 100 nM), a NO donor, mimicked the effects of Ginsenoside R-e. And pretreatment with a NOS inhibitor N-omega-Nitro-L-arginine methyl ester (L-NAME, 100 mu M) or a NO scavenger N-Acetyl-L-cysteine (LNAC, 1 mM) completely blocked the effects of Ginsenoside R-e. Data suggested that Ginsenoside R-e is beneficial to sperm motility, and that induction of NOS to increase NO production may be involved in this benefit.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An automated biomolecular interaction analysis instrument (BI-Acore) based on surface plasmon resonance (SPR) has been used to determine human immunoglobulin G (IgG) in real time. Polyclonal anti-human IgG antibody was covalently immobilized to a carboxymethyldextran modified gold film surface. The samples of human IgG prepared in HBS buffer were poured over the immobilized surface. The signal amplification antibody was applied to amplify the response signal. After each measurement, the surface was regenerated with 0.1 mol/L H3PO4. The assay was rapid, requiring only 30 min for antibody immobilization and 20 min for each subsequent process of immune binding, antibody amplification and regeneration. The antibody immobilized surface had good response to human IgG in the range of 0.12-60 nmol/L with a detection limit of 60 pmol/L. The same antibody immobilized surface could be used for more than 110 cycles of binding, amplification and regeneration. The results demonstrate that the sensitivity, specificity and reproducibility of amplified immunoassay using real-time BIA technology are satisfactory.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Inductively coupled plasma mass spectrometry (ICP-MS),a highly sensitive inorgnic analytic technique,fits to determine ultra-nace rare-earth elements in human plasma. Under the optimized conditions detection limits for 15 rare-earth elements are in the range of 0.7 (for Eu)-5.4 (for Gd) ng.L-1. Indium as an internal standard element is used to compensate for matrix suppression effect and sensitivity drift. Three kinds of preparation methods, diluted with 1% HNO3, digested with HNO3-H2O2 and with HNO3-HClO4, are checked and compared,and the former is the simplest way to be measured. The samples diluted with 1% HNO3, stored in 4 degrees C, are very steady for 16 days. With the method, 11 healthy plasma samples in Changchun area of China are analysed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple set of electric circuits was used to assemble a pulse generator. With pulse potentials and under galvanostatical control, a clean silver wire was anodized electrochemically for 0.2-0.5 min in 1.0 moll(-1) HCl with a pulse current density of 20 mA cm(-2), and the pulse wave parameters of t(a)/t(c) = 1 and a cycle of 4 s forming an Ag/AgCl reference electrode. Even though the AgCl layer was consumed during the working period when the Ag/AgCl electrode was used as a cathode, the AgCl layer could be in situ recovered electrochemically in serum used when a reversed potential was applied to the electrode system immediately after the measuring program was finished. The current response curve of the anode indicated that an AgCl layer in high density was basically accomplished during the first 6 pulse cycles in human serum. In order to keep a stable and uniform AgCl layer on the reference electrode after each measuring cycle, the ratio of the recovery time (t(r)) to the working time (t(w)) was measured and the smallest value was obtained at 0.03. The open-circuit potential of the Ag/AgCl electrode with respect to a SCE in 0.1 moll(-1) KCl was monitored over a period of 14 days and the mean value was 40.09 mV vs SCE with a standard deviation of 2.55 mV. The potential of the Ag/AgCl reference electrode did remain constant when the measurements were repeated more than 600 times in undiluted human serum with a standard deviation of 1.89 mV. This study indicated that the Ag/AgCl reference electrode could been rapidly fabricated with a pulse potential and could be used as a reference electrode with long-term stable properties in human serum samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An assay procedure utilizing pulsed amperometric detection at a platinum-particles modified electrode has been developed for the determination of cysteine and glutathione in blood samples following preliminary separation by reversed-phase liquid chromatography. A chemically modified electrode (CME) constructed by unique electroreduction from a platinum-salt solution to produce dispersed Pt particles on a glassy carbon surface was demonstrated to catalyze the electo-oxidation of sulfhydryl-containing compounds: DL-cysteine (CYS), reduced glutathione (GSH). When used as the sensing electrode in flow-system pulsed-amperometric detection (PAD), electrode fouling could be avoided using a waveform in which the cathodic reactivation process occurred at a potential of - 1.0 V vs. Ag/AgCl to achieve a cathodic desorption of atomic sulfur. A superior detection limit for these free thiols was obtained at a Pt particle-based GC electrode compared with other methods; this novel dispersed Pt particles CME exhibited high electrocatalytic stability and activity when it was employed as an electrochemical detector in FIA and HPLC for the determination of those organo-sulfur compounds.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The construction of the shuttle, expression vector of human tumor necrosis factor alpha (hTNF-alpha) gene and its expression in a cyanobacterium Anabaena sp. PCC 7120 was reported. The 700-bp hTNF cDNA fragments have been recovered from plasmid pRL-rhTNF, then inserted downstream of the promoter PpsbA in the plasmid pRL439. The resultant intermediary plasmid pRL-TC has further been combined with the shuttle vector pDC-8 to get the shuttle, expression vector pDC-TNF. The expression of the rhTNF gene in Escherichia coil has been analyzed by SDS-PAGE and thin-layer scanning, and the results show that the expressed TNF protein with these two vectors is 16.9 percent (pRL-TC) and 15.0 percent (pDC-TNF) of the total proteins in the cells, respectively, while the expression level of TNF gene in plasmid pRL-rhTNF is only 11.8 percent. Combined with the participation of the conjugal and helper plasmids, pDC-TNF has been introduced into Anabaena sg PCC 7120 by triparental conjugative transfer, and the stable transgenic strains have been obtained. The existence of the introduced plasmid pDC-TNF in recombinant cyanobacterial cells has been demonstrated by the results of the agarose electrophoresis with the extracted plasmid samples and Southern blotting with alpha-(32)p labeled hTNF cDNA probes, while the expression of the hTNF gene in Anabaena sp. PCC 7120 has been confirmed by the results of Western blotting with extracted protein samples and human TNF-alpha monoclonal antibodies. The cytotoxicity assays using the mouse cancer cell line L929 proved the cytotoxicity of the TNF in the crude extracts from the transgenic cyanobacterium Anabaena sp. PCC 7120.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A highly sensitive and accurate method based on the precolumn derivatization of bile acids (BA) with a high ionization efficiency labeling reagent 1,2-benzo-3,4-dihydrocarbazole-9-ethyl-benzenesulfonate (BDEBS) coupled with LC/MS has been developed. After derivatization, BA molecules introduced a weak basic nitrogen atom into the molecular core structure that was readily ionized in commonly used acidic HPLC mobile phases. Derivatives were sufficiently stable to be efficiently analyzed by atmospheric pressure chemical ionization (APCI)-MS/MS in positive-ion mode. The MS/MS spectra of BA derivatives showed an intense protonated molecular ion at m/z [M + H](+). The collision-induced dissociation of the molecular ion produced fragment ions at [MH - H2O](+), [MH - 2H(2)O](+), [MH - 3H(2)O](+). The characteristic fragment ions were at m/z 320.8, 262.8, and 243.7 corresponding to a cleavage of N - CO, O - CO, and C - OCC, respectively, and bonds of derivatized molecules. The selected reaction monitoring, based on the m/z [M + H]+ -> [MH - H2O](+), [MH - H2O](+), [MH - 2H(2)O](+), [MH-3H(2)O](+), 320.8, 262.8, and 243.7 transitions, was highly specific for the BA derivatives. The LODs for APCI in a positive-ion mode, at an S/N of 5, were 44.36-153.6 fmol. The validation results showed high accuracy in the range of 93-107% and the mean interday precision for all standards was < 15% at broad linear dynamic ranges (0.0244-25nmol/mL). Good linear responses were observed with coefficients of > 0.9935 in APCI/MS detection. Therefore, the facile BDEBS derivatization coupled with mass spectrometric analysis allowed the development of a highly sensitive and specific method for the quantitation of trace levels of the free and glycine-conjugated BA from human serum samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Capillary zone electrophoresis was used to monitor the interaction between bilirubin and human serum albumin. Cord blood serum samples were injected directly into an uncoated fused-silica capillary (30 cm x 50 mu m i.d.) and separation was accomplished within 4 min without extensive sample pretreatment. The most suitable running buffer to separate free bilirubin from albumin bound bilirubin was found to contain 1.0 mmol/L EDTA, 5% acetonitrile and 15 mmol/L phosphate with pH adjusted to 8.4. Approximately two bilirubin dianions could be bound per human serum albumin molecule in the cord blood serum. The binding constant was estimated to be 1.1 x 10(5) (L/mol) at 25 degrees C and pH 8.4. The peak area ratio of free bilirubin to total bilirubin can be used to determine the bilirubin binding capacity of cord blood serum for the concentration range of total bilirubin from 204 to 340 mu mol/L using 1:5 diluted cord blood seras. Copyright (C) 1999 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A resurgence of interest in the human plasma proteome has occurred in recent years because it holds great promise of revolution in disease diagnosis and therapeutic monitoring. As one of the most powerful separation techniques, multidimensional liquid chromatography has attracted extensive attention, but most published works have focused on the fractionation of tryptic peptides. In this study, proteins from human plasma were prefractionated by online sequential strong cation exchange chromatography and reversed-phase chromatography. The resulting 30 samples were individually digested by trypsin, and analyzed by capillary reversed-phase liquid chromatography coupled with linear ion trap mass spectrometry. After meeting stringent criteria, a total of 1292 distinct proteins were successfully identified in our work, among which, some proteins known to be present in serum in < 10 ng/mL were detected. Compared with other works in published literatures, this analysis offered a more full-scale list of the plasma proteome. Considering our strategy allows high throughput of protein identification in serum, the prefractionation of proteins before MS analysis is a simple and effective method to facilitate human plasma proteome research.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pyatt, F.B., Pyatt, A.J., Walker, C., Sheen, T., Grattan, J.P, The heavy metal content of skeletons from an ancient metalliferous polluted area in southern Jordan with particular reerence to bioaccumulation and human health, Ecotoxicology & Environmental Safety 60, 13th August 2003, 295-300

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Infection with multiple types of human papillomavirus (HPV) is one of the main risk factors associated with the development of cervical lesions. In this study, cervical samples collected from 1, 810 women with diverse sociocultural backgrounds, who attended to their cervical screening program in different geographical regions of Colombia, were examined for the presence of cervical lesions and HPV by Papanicolau testing and DNA PCR detection, respectively. Principal Findings: The negative binomial distribution model used in this study showed differences between the observed and expected values within some risk factor categories analyzed. Particularly in the case of single infection and coinfection with more than 4 HPV types, observed frequencies were smaller than expected, while the number of women infected with 2 to 4 viral types were higher than expected. Data analysis according to a negative binomial regression showed an increase in the risk of acquiring more HPV types in women who were of indigenous ethnicity (+37.8%), while this risk decreased in women who had given birth more than 4 times (-31.1%), or were of mestizo (-24.6%) or black (-40.9%) ethnicity. Conclusions: According to a theoretical probability distribution, the observed number of women having either a single infection or more than 4 viral types was smaller than expected, while for those infected with 2-4 HPV types it was larger than expected. Taking into account that this study showed a higher HPV coinfection rate in the indigenous ethnicity, the role of underlying factors should be assessed in detail in future studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: HIV infection leads to a decreasing immune response, thereby facilitating the appearance of other infections, one of the most important ones being HPV. However, studies are needed for determining associations between immunodeficiency caused by HIV and/or the presence of HPV during the course of cervical lesions and their degree of malignancy. This study describes the cytological findings revealed by the Papanicolaou test, laboratory characteristics and HPV molecular profile in women with and without HIV infection. Methods: A total of 216 HIV-positive and 1,159 HIV-negative women were invited to participate in the study; PCR was used for the molecular detection of HPV in cervical samples. Statistical analysis (such as percentages, Chi-square test and Fisher's exact test when applicable) determined human papillomavirus (HPV) infection frequency (single and multiple) and the distribution of six types of high-risk-HPV in women with and without HIV infection. Likewise, a logistic regression model was run to evaluate the relationship between HIV-HPV infection and different risk factors. Results: An association was found between the frequency of HPV infection and infection involving 2 or more HPV types (also known as multiple HPV infection) in HIV-positive women (69.0% and 54.2%, respectively); such frequency was greater than that found in HIV-negative women (44.3% and 22.7%, respectively). Statistically significant differences were observed between both groups (p = 0.001) regarding HPV presence (both in infection and multiple HPV infection). HPV-16 was the most prevalent type in the population being studied (p = 0.001); other viral types had variable distribution in both groups (HIV-positive and HIV-negative). HPV detection was associated with <500 cell/mm(3) CD4-count (p = 0.004) and higher HIV-viral-load (p = 0.001). HPV-DNA detection, <200 cell/mm(3) CD4-count (p = 0.001), and higher HIV-viral-load (p = 0.001) were associated with abnormal cytological findings. Conclusions: The HIV-1 positive population in this study had high multiple HPV infection prevalence. The results for this population group also suggested a greater association between HPV-DNA presence and cytological findings. HPV detection, together with low CD4 count, could represent useful tools for identifying HIV-positive women at risk of developing cervical lesions.