538 resultados para HEMODIALYSIS
Resumo:
Hypotension during intermittent hemodialysis is common, and has been attributed to acute volume shifts, shifts in osmolarity, electrolyte imbalance, temperature changes, altered vasoregulation, and sheer hypovolemia. Although hypovolemia may intuitively seem a likely cause for hypotension in intensive care patients, its role in the pathogenesis of intradialytic hypotension may be overestimated.
Resumo:
We have spectroscopically determined breath ammonia levels in seven patients with end-stage renal disease while they were undergoing hemodialysis at the University of California, Los Angeles, dialysis center. We correlated these measurements against simultaneously taken blood samples that were analyzed for blood urea nitrogen (BUN) and creatinine, which are the accepted standards indicating the level of nitrogenous waste loading in a patient's bloodstream. Initial levels of breath ammonia, i.e., at the beginning of dialysis, are between 1,500 ppb and 2,000 ppb (parts per billion). These levels drop very sharply in the first 15–30 min as the dialysis proceeds. We found the reduction in breath ammonia concentration to be relatively slow from this point on to the end of dialysis treatment, at which point the levels tapered off at 150 to 200 ppb. For each breath ammonia measurement, taken at 15–30 min intervals during the dialysis, we also sampled the patient's blood for BUN and creatinine. The breath ammonia data were available in real time, whereas the BUN and creatinine data were available generally 24 h later from the laboratory. We found a good correlation between breath ammonia concentration and BUN and creatinine. For one of the patients, the correlation gave an R2 of 0.95 for breath ammonia and BUN correlation and an R2 of 0.83 for breath ammonia and creatinine correlation. These preliminary data indicate the possibility of using the real-time breath ammonia measurements for determining efficacy and endpoint of hemodialysis.
Resumo:
Vol. 1 is a synopsis of vol. 2.
Resumo:
The clinical usefulness of hemodialysis catheters is limited by increased infectious morbidity and mortality. Topical antiseptic agents, such as mupirocin, are effective at reducing this risk but have been reported to select for antibiotic-resistant strains. The aim of the present study was to determine the efficacy and the safety of exit-site application of a standardized antibacterial honey versus mupirocin in preventing catheter-associated infections. A randomized, controlled trial was performed comparing the effect of thrice-weekly exit-site application of Medihoney versus mupirocin on infection rates in patients who were receiving hemodialysis via tunneled, cuffed central venous catheters. A total of 101 patients were enrolled. The incidences of catheter-associated bacteremias in honey-treated (n = 51) and mupirocin-treated (n = 50) patients were comparable (0.97 versus 0.85 episodes per 1000 catheter-days, respectively; NS). On Cox proportional hazards model analysis, the use of honey was not significantly associated with bacteremia-free survival (unadjusted hazard ratio, 0.94; 95% confidence interval, 0.27 to 3.24; P = 0.92). No exit-site infections occurred. During the study period, 2% of staphylococcal isolates within the hospital were mupirocin resistant. Thrice-weekly application of standardized antibacterial honey to hemodialysis catheter exit sites was safe, cheap, and effective and resulted in a comparable rate of catheter-associated infection to that obtained with mupirocin (although the study was not adequately powered to assess therapeutic equivalence). The effectiveness of honey against antibiotic-resistant microorganisms and its low likelihood of selecting for further resistant strains suggest that this agent may represent a satisfactory alternative means of chemoprophylaxis in patients with central venous catheters.
Resumo:
Background: Relationships between low-density lipoprotein cholesterol and endothelial function in hemodialysis patients have yet to be investigated. Furthermore, current reporting of endothelial function data using flow-mediated dilatation has recognised limitations. The aims of the study were to determine the relationship between low-density lipoproteins and endothelial function in hemodialysis patients and to investigate the validity of determining the area under the curve for data collected during the flow-mediated dilatation technique. Methods: Brachial artery responses to reactive hyperemia (endothelial-dependent) and glyceryl trinitrate (endothelial-independent) were assessed in 19 hemodialysis patients using high-resolution ultrasound. Lipid profiles and other factors known to effect brachial artery reactivity were also measured prior to the flow-mediated dilatation technique. Results: There were no significant relationships between serum low-density lipoproteins and endothelial-dependent or -independent vasodilation using absolute change (mm), relative change (%), time to peak change (s) or area under the curve (mm(.)s). In hemodialysis patients with atherosclerosis, area under the curve analysis showed a significantly (p < 0.05) decreased endothelial-dependent response (mean +/- S.D.: 19.2 +/- 17.4) compared to non-atherosclerotic patients (42.3 +/- 28.6). However, when analysing these data using absolute change, relative change or time to peak dilatation, there were no significant differences between the two groups. Conclusions: In summary, there was no relationship between low-density lipoproteins and endothelial function in hemodialysis patients. In addition, area under the curve analysis of flow-mediated vasodilatation data may be a useful method of determining the temporal vascular response during the procedure. (c) 2004 Elsevier Ireland Ltd. All rights reserved.
Resumo:
The aim of this study was to ascertain the most suitable dosing schedule for gentamicin in patients receiving hemodialysis. We developed a model to describe the concentrationtime course of gentamicin in patients receiving hemodialysis. Using the model, an optimal dosing schedule was evaluated. Various dosing regimens were compared in their ability to achieve maximum concentration (C-max, >= 8 mg/L) and area under the concentration time-curve (AUC >= 70 mg(.)h/L and <= 120 mg(.)h/L per 24 hours). The model was evaluated by comparing model predictions against real data collected retrospectively. Simulations from the model confirmed the benefits of predialysis dosing. The mean optimal dose was 230 mg administered immediately before dialysis. The model was found to have good predictive performance when simulated data were compared to data observed in real patients. In summary, a model was developed that describes gentamicin pharmacokinetics in patients receiving hemodialysis. Predialysis dosing provided a superior pharmacokinetic profile than did postdialysis dosing.
Resumo:
The aim of this study was to evaluate dosing schedules of gentamicin in patients with end-stage renal disease and receiving hemodialysis. Forty-six patients were recruited who received gentamicin while on hemodialysis. Each patient provided approximately 4 blood samples at various times before and after dialysis for analysis of plasma gentamicin concentrations. A population pharmacokinetic model was constructed using NONMEM (version 5). The clearance of gentamicin during dialysis was 4.69 L/h and between dialysis was 0.453 L/h. The clearance between dialysis was best described by residual creatinine clearance (as calculated using the Cockcroft and Gault equation), which probably reflects both lean mass and residual clearance mechanisms. Simulation from the final population model showed that predialysis dosing has a higher probability of achieving target maximum concentration (C-max) concentrations (> 8 mg/L) within acceptable exposure limits (area under the concentration-time curve [AUC] values > 70 and < 120 mg.h/L per 24 hours) than postdialysis dosing.
Resumo:
Purpose: The authors report the first case, to their knowledge, of resolution of diffuse macular edema after hemodialysis, which has been confirmed by optical coherence tomography. Methods: A 53-year-old white woman with type 2 diabetes developed worsening macular edema and was examined in the ophthalmology clinic and scheduled for macular grid laser photocoagulation. The laser, however, was deferred for 4 weeks because she had also developed end-stage renal failure and required hemodialysis. Results: When she was reviewed in the ophthalmology clinic 4 weeks later for laser therapy, it was found that her macular edema had resolved, vision had improved, and laser was unnecessary. Review at 6 months showed that the macular edema remains resolved. Conclusion: Ophthalmologists should be aware that hemodialysis may reduce macular edema in such patients. Copyright © by Ophthalmic Communications Society Inc.
Resumo:
Objective: The study was performed to investigate the association of interleukin 17 (IL 17) or angiotensin II (Ang II) with refractory hypertension risk in hemodialysis patients. Methods: Ninety hemodialysis patients were enrolled into this study, and those with hypertension were divided into two groups. The Easy-to-Control Hypertension group (ECHG) had fifty patients, while the refractory hypertension group (RHG) had forty patients. Twenty healthy individuals were recruited as the control group. IL17 and Ang II were determined using a human IL 17 / Ang II enzyme-linked immunosorbent assay kit. Serum IL 17 and Ang II concentrations in RHG patients were higher than those in ECHG patients. Results: Serum IL 17 and Ang II concentrations in both patient groups were higher than those in the control group. Linear regression analysis showed a positive correlation between IL 17 and Ang II. In multivariate regression analysis, we found that IL17 and Ang II were associated with refractory hypertension risk in hemodialysis patients. Conclusion: IL17 and Ang II were associated with refractory hypertension risk in hemodialysis patients. There was also a positive correlation between IL 17and Ang II.
Resumo:
to be from 2.5 to 5.5 cases per 1,000 catheter-day. the clinical impact is relevant and increases the cost of the HD Unit. Methods: The present study is the irst of 2 phases. It was conducted from January to December of 2012, and included all patients and nurses who were in the HD Unit. The prevalence of Gramnegative bacilli (GNB) and methicillin-resistant Staphylococcus aureus (MrSA) colonizing the nasal passages and the skin is described. Also, phenotypic association was sought by genus, species and sensitivities between colonizing bacterial strains and blood cultures with GNB and MRSA. Results: the study included 70 patients and 10 nurses. the prevalence of nasal colonization in patients by GNB was 9% and 6% in the pericatheter, and no nursing GNB colonization was discovered. The prevalence of MRSA nasal colonization was 19% and 6% in the pericatheter for patients and in the nurses the nasal colonization was 50% and 10% in the hands. We identiied 29 cases of primary bacteremia. The primary bacteremia rate is 1.5 per 1,000 catheter-day or 0.4 episodes per patient per year. Conclusion: We demonstrated a high prevalence of MrSA colonization in patients and nurses in the HD Unit. No relationship was found between primary bacteremia by GNB and patients and nurses’ bacteria colonization by the phenotypic comparison.
Resumo:
The present work is focused on the synthesis and characterization of novel materials for hemodialysis applications. Cellulose acetate was chosen as base polymer for the preparation of porous Mixed Matrix Membrane adsorbers (MMMAs) and for the synthesis of hybrid ultrafiltration membranes. Hemodialysis is a renal replacement therapy used to eliminate,the waste products and excess fluids accumulating in the blood of people affected by an end stage renal disease. The main environmental drawback associated to it is the large water consumption. The MMMAs were prepared with the porpoise of eliminating waste metabolites (uremic toxins) from the spent dialysate solution, with the prospective limiting the consumption of water related to the process. Batch tests of MMMAs showed that the removal of uric acid is almost complete while the one of urea and creatinine is limited to a 20/30 %. The thinking behind the concept of MMMAs was aimed to develop a small a lab scale chromatographic cartridge to continuously remove uremic toxins from an aqueous feed solution. The cartridge was packed with MMMAs and tested with a mixture of toxins. Experiments results shown a promising removal capability of the system even if the necessity of a higher surface area to achieve better efficiency is denoted. The other important issue related to hemodialysis is the assessment of an overall mass transfer rates in hemodialyzers. The mass transfer correlations proposed in literature do not take into account the effect of permeation and are developed for turbulent flow regime. Therefore, hybrid cellulose acetate/Silica ultrafiltration membranes were prepared to characterize a surrogate system of an artificial kidney (AK) in terms of fluid mechanics and mass transfer. The effect of surface roughness and suction on the velocity profiles was determined and a new dimensionless mass transfer correlation accounting for permeation was developed.