962 resultados para GAS ANALYSIS
Resumo:
The aim of this study was to validate oxygen-sensitive 3He-MRI in noninvasive determination of the regional, two- and three-dimensional distribution of oxygen partial pressure. In a gas-filled elastic silicon ventilation bag used as a lung phantom, oxygen sensitive two- and three-dimensional 3He-MRI measurements were performed at different oxygen concentrations which had been equilibrated in a range of normal and pathologic values. The oxygen partial pressure distribution was determined from 3He-MRI using newly developed software allowing for mapping of oxygen partial pressure. The reference bulk oxygen partial pressure inside the phantom was measured by conventional respiratory gas analysis. In two-dimensional measurements, image-based and gas-analysis results correlated with r=0.98; in three-dimensional measurements the between-methods correlation coefficient was r=0.89. The signal-to-noise ratio of three-dimensional measurements was about half of that of two-dimensional measurements and became critical (below 3) in some data sets. Oxygen-sensitive 3He-MRI allows for noninvasive determination of the two- and three-dimensional distribution of oxygen partial pressure in gas-filled airspaces.
Resumo:
Low molecular weight hydrocarbon (LMWH) distributions were examined in sediments from Sites 1109 and 1115 in the western Woodlark Basin using purge-trap thermal adsorption/desorption gas analysis. A number of different hydrocarbon components >C1, which were not detected during shipboard gas analysis, were detected at both sites using the purge-trap procedure. Concentrations of ethane, propane, and butane remained relatively low (<100 pmol/g) throughout Site 1109 and had no consistent trend with depth. In contrast, the longer-chain components increased in concentration with depth. Hexane concentrations rose to 716 pmol/g at the base of the site with a concomitant increase in both 2-methyl- and 3-methylpentane. At Site 1115, concentrations of ethane, propane, butane, and isobutylene + 1-butene remained low (<60 pmol/g) throughout the site and again had no consistent trend with depth. 2-Methylpentane, 3-methylpentane, and hexane concentrations had a subsurface maximum that coincided with sediments containing abundant plant-rich material. The LMWH downhole profiles plus low in situ temperatures suggest that the LMWH components were formed in situ by low-temperature biological processes. Purge-trap analysis has indicated the presence of some unexpected deep low-temperature bacterial reactions, which demonstrates that further analysis of LMWH may provide valuable information at future Ocean Drilling Program sites.
Resumo:
We investigated gas bubble emissions at the Don-Kuban paleo-fan in the northeastern Black Sea regarding their geological setting, quantities as well as spatial and temporal variabilities during three ship expeditions between 2007 and 2011. About 600 bubble-induced hydroacoustic anomalies in the water column (flares) originating from the seafloor above the gas hydrate stability zone (GHSZ) at ~700 m water depth were found. At about 890 m water depth a hydrocarbon seep area named "Kerch seep area" was newly discovered within the GHSZ. We propose locally domed sediments ('mounds') discovered during ultra-high resolution bathymetric mapping with an autonomous underwater vehicle (AUV) to result from gas hydrate accumulation at shallow depths. In situ measurements indicated spatially limited temperature elevations in the shallow sediment likely induced by upward fluid flow which may confine the local GHSZ to a few meters below the seafloor. As a result, gas bubbles are suspected to migrate into near-surface sediments and to escape the seafloor through small-scale faults. Hydroacoustic surveys revealed that several flares originated from a seafloor area of about 1 km**2 in size. The highest flare disappeared in about 350 m water depth, suggesting that the released methane remains in the water column. A methane flux estimate, combining data from visual quantifications during dives with a remotely operated vehicle (ROV) with results from ship-based hydroacoustic surveys and gas analysis revealed that between 2 and 87 x 10**6 mol CH4 yr-1 escaped into the water column above the Kerch seep area. Our results show that the finding of the Kerch seep area represents a so far underestimated type of hydrocarbon seep, which has to be considered in methane budget calculations.