Two-dimensional and three-dimensional oxygen mapping by 3He-MRI validation in a lung phantom


Autoria(s): Gast, Klaus Kurt; Schreiber, Wolfgang G; Herweling, Annette; Lehmann, Frank; Erdös, Gabor; Schmiedeskamp, Joerg; Kauczor, Hans-Ulrich; Eberle, Balthasar
Data(s)

01/09/2005

Resumo

The aim of this study was to validate oxygen-sensitive 3He-MRI in noninvasive determination of the regional, two- and three-dimensional distribution of oxygen partial pressure. In a gas-filled elastic silicon ventilation bag used as a lung phantom, oxygen sensitive two- and three-dimensional 3He-MRI measurements were performed at different oxygen concentrations which had been equilibrated in a range of normal and pathologic values. The oxygen partial pressure distribution was determined from 3He-MRI using newly developed software allowing for mapping of oxygen partial pressure. The reference bulk oxygen partial pressure inside the phantom was measured by conventional respiratory gas analysis. In two-dimensional measurements, image-based and gas-analysis results correlated with r=0.98; in three-dimensional measurements the between-methods correlation coefficient was r=0.89. The signal-to-noise ratio of three-dimensional measurements was about half of that of two-dimensional measurements and became critical (below 3) in some data sets. Oxygen-sensitive 3He-MRI allows for noninvasive determination of the two- and three-dimensional distribution of oxygen partial pressure in gas-filled airspaces.

Formato

application/pdf

Identificador

http://boris.unibe.ch/63836/1/art%253A10.1007%252Fs00330-005-2778-x.pdf

Gast, Klaus Kurt; Schreiber, Wolfgang G; Herweling, Annette; Lehmann, Frank; Erdös, Gabor; Schmiedeskamp, Joerg; Kauczor, Hans-Ulrich; Eberle, Balthasar (2005). Two-dimensional and three-dimensional oxygen mapping by 3He-MRI validation in a lung phantom. European radiology, 15(9), pp. 1915-1922. Springer 10.1007/s00330-005-2778-x <http://dx.doi.org/10.1007/s00330-005-2778-x>

doi:10.7892/boris.63836

info:doi:10.1007/s00330-005-2778-x

info:pmid:15856240

urn:issn:0938-7994

Idioma(s)

eng

Publicador

Springer

Relação

http://boris.unibe.ch/63836/

Direitos

info:eu-repo/semantics/restrictedAccess

Fonte

Gast, Klaus Kurt; Schreiber, Wolfgang G; Herweling, Annette; Lehmann, Frank; Erdös, Gabor; Schmiedeskamp, Joerg; Kauczor, Hans-Ulrich; Eberle, Balthasar (2005). Two-dimensional and three-dimensional oxygen mapping by 3He-MRI validation in a lung phantom. European radiology, 15(9), pp. 1915-1922. Springer 10.1007/s00330-005-2778-x <http://dx.doi.org/10.1007/s00330-005-2778-x>

Palavras-Chave #610 Medicine & health
Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

PeerReviewed