809 resultados para Electrochemical immunoassay
Resumo:
Electrode kinetics and study of 'transition state' with applied potential in case of [M - antibiotics - cephalothin] system were reported at pH = 7.30 ± 0.01 at suitable supporting electrolyte at 25.0ºC. The M = Co or Ni and antibiotics were doxycycline, chlortetracycline, oxytetracycline, tetracycline, minocycline, amoxicillin and chloramphenicol used as primary ligands and cephalothin as secondary ligand. Kinetic parameters viz. transfer coefficient (a), degree of irreversibility (l), diffusion coefficient (D) and rate constant (k) were determined. The values of a and k varied from 0.41 to 0.59 and 2.60 X 10-3 cm s-1 to 9.67 X 10-3 cm s-1 in case of [Co - antibiotics - cephalothin] system. In case of [Ni - antibiotics - cephalothin], a and k varied from 0.41 to 0.58 and 2.34 X 10-3 cm s-1 to 9.19 X 10-3 cm s-1 respectively confirmed that transition state behaves between oxidant and reductant response to applied potential and it adjusts it self in such a way that the same is located midway between dropping mercury electrode and solution interface. The values of rate constant confirmed the quasireversible nature of electrode processes. The stability constants (logb) of complexes were also determined.
Resumo:
Bis-(µ2-oxo)-tetrakis{[1-feniltriazene-1,3-diil)-2-(phenyltriazenil)benzene copper(II) is a tetranuclear complex which shows four Cu(II) ions coordinated by four 1,2-bis(phenyltriazene)benzene bridged ligands, with one diazoaminic deprotonated chain, and two O2- ligands. The complex reduces at E1/2 = -0.95 V vs Fc+/Fc, a two electrons process. Cyclic voltammetric and spectroelectrochemical studies showed a reversible process. When immobilized on carbon paste electrode, the complex electrocatalyses the reduction of O2 dissolved on aqueous solution at -0.3 V vs SCE potential. The obtained current shows linearity with O2 concentration.
Resumo:
Vi omges i vardagen av alla sorters plaster, som kemiskt kallas för polymerer. Vi anknyter dem oftast till vardagliga föremål såsom muggar, leksaker eller platskassar. Det finns dock en särklass av polymerer som fås elektriskt ledande genom en så kallad dopningsprocess. Dopning innebär i detta fall oxidation eller reduktion av konjugerade dubbelbindningar i polymerstrukturen. Detta har lett till utveckling av elektriska apparater där dyra, och i vissa fall även sällsynta, metall och halvledarmaterial ersätts genom av elektriskt ledande polymerer (plaster). Utöver elektronisk ledningsförmåga uppvisar dessa polymerer också jonisk ledningsförmåga. Denna kombination av unika egenskaper möjliggör skapandet av t.ex. nya sensormaterial som kan överföra kemisk information till en mätbar elektronisk signal. Detta öppnar i sin tur möjligheter att göra snabba, billiga och känsliga sensorer för bl.a. mediciniska analyser. I denna avhandling karakteriserades elektrokemiskt och spektroelektrokemiskt N- och ring-substituerade polyanilinfilmer. Polyanilin (PANI) hör till de mest studerade elektriskt ledande polymererna. Den är stabil och lätt att framställa. Substituerade polyaniliner har ändå studerats måttligt, mest p.g.a. att substituerade PANIs ledningsförmåga är lägre än PANIs och deras framställning kan vara svår. De nya grupperna i PANI-kedjan ger dock en möjlighet att binda ytterligare molekyler av intresse till PANI-kedjan, som t.ex. jonselektiva grupper. Kovalent bundna selektiva molekyler ger upphov till stabila, känsliga och selektiva sensormaterial. Karakteriseringen av de studerade polymerer är viktig för den fundamentala förståelsen av deras unika egenskaper och för utvecklingen av framtidens sensormaterial. -------------------------------------- Käytämme joka päivä monenlaisia muoveja, joita kutsutaan kemiassa myös polymeereiksi. Olemme tottuneet yhdistämään muovit arkisiin esineisiin kuten mukeihin, leluihin tai muovikasseihin. On kuitenkin olemassa erityisiä polymeerejä, jotka voidaan saada sähköä johtaviksi hapetus- ja pelkistysreaktioiden avulla. Tästä johtuen on kehitteillä sähköisiä laitteita, joissa kalliit ja jossain tapauksissa myös harvinaisia metalleja sisältävät osat ja puolijohteet voidaan korvata johdepolymeereillä (eli muoveilla). Sähkönjohtavuuden lisäksi johdepolymeereillä on myös ionijohtavuutta. Näiden erityislaatuisten ominaisuuksien yhdistelmä on mahdollistanut mm. sensorimateriaalin kehittämisen, sillä kemiallinen tieto voidaan kääntää mitattavaksi sähköiseksi signaaliksi. Tämä taas omalta osaltaan mahdollistaisi nopeiden, halpojen ja herkkien sensorien valmistuksen, mm. diagnostiikkaan. Tässä väitöksessä on tutkittu sähkökemiallisesti valmistettuja N- ja rengassubstituoituja polyaniliinikalvoja. Polyaniliini (PANI) on yksi eniten tutkituista johdepolymeereistä. Se on stabiili ja helppo valmistaa. Substituoidut polyaniliinit ovat herättäneet vain kohtalaista tieteellistä kiinnostusta, lähinnä, koska niiden sähköinen johdekyky on alhaisempi kuin PANIn. Myös niiden valmistus voi olla vaikeaa. Substituoidut molekyylit PANI-ketjussa mahdollistavat kuitenkin, että niihin voi liittää uusia molekyylejä, esim. ioniherkkiä ryhmiä. Kovalentisti sitoutuneilla selektiivisillä molekyyleillä saadaan tehtyä stabiileja, herkkiä ja selektiivisiä sensorimateriaaleja. Väitöksessä käytettyjen polymeerien karakterisointi on tärkeää, jotta niiden erityisominaisuuksia pystyttäisiin ymmärtämään paremmin ja myös kehittämään sopivia tulevaisuuden sensorimateriaaleja.
Resumo:
A rapid indirect enzyme-linked immunosorbent assay (ELISA) was developed for measuring antibodies against Leishmania chagasi using total antigen from lysed promastigotes. Fifty symptomatic mixed breed dogs from a region of high incidence of visceral leishmaniasis in Brazil were examined. The results showed that in the positive animals, diagnosed by cytological examination, the ELISA using protein A assay system (mean optical density ± SD / 2.078 ± 0.631) detected more antibodies than the anti-IgG assay (mean optical density ± SD / 1.008 ± 0.437), while in the negative animals, the results by both systems were similar. These results suggest that the ELISA assay using protein A peroxidase conjugated could be useful to detect early infected animals in endemic areas, and thus help to control the spread of the infection.
Resumo:
Electrocoagulation is a process in which wastewater is treated under electrical current. Coagulant is formed during the process through the metal anode dissolution to respective ions which react with hydroxyl ions released in cathode. These metal hydroxides form complexes with pollutant ions. Pollutants are removed among metal hydroxide precipitates. This study was concentrated on describing chemistry and device structures in which electrochemical treatment operations are based on. Studied pollutants were nitrogen compounds, sulphate, trivalent and pentavalent arsenic, heavy metals, phosphate, fluoride, chloride, and bromide. In experimental part, removal of ammonium, nitrate, and sulphate during electrochemical treatment was studied separately. Main objective of this study was to find suitable metal plate material for ammonium, nitrate, and sulphate removal, respectively. Also other parameters such as pH of solution, concentration of pollutant and sodium chloride, and current density were optimized. According to this study the most suitable material for ammonium and sulphate removal by electrochemical treatment was stainless steel. Respectively, iron was the optimum material for nitrate removal. Rise in the pH of solution at the final stage of electrochemical treatment of ammonium, nitrate, and sulphate was detected. Conductivities of solutions decreased during ammonium removal in electrochemical processes. When nitrate and sulphate were removed electrochemically conductivities of solutions increased. Concentrations of residual metals in electrochemically treated solutions were not significant. Based on this study electrochemical treatment processes are recommended to be used in treatment of industrial wastewaters. Treatment conditions should be optimized for each wastewater matrix.
Resumo:
Polarization curves experimentally obtained in the electro-dissolution of iron in a 1 M H2SO4 solution using a rotating disc as the working electrode present a current instability region within the range of applied voltage in which the current is controlled by mass transport in the electrolyte. According to the literature (Barcia et. al., 1992) the electro-dissolution process leads to the existence of a viscosity gradient in the interface metal-solution, which leads to a velocity field quantitatively different form the one developed in uniform viscosity conditions and may affect the stability of the hydrodynamic field. The purpose of this work is to investigate whether a steady viscosity profile, depending on the distance to the electrode surface, affects the stability properties of the classic velocity field near a rotating disc. Two classes of perturbations are considered: perturbations monotonically varying along the radial direction, and perturbations periodically modulated along the radial direction. The results show that the hydrodynamic field is always stable with respect to the first class of perturbations and that the neutral stability curves are modified by the presence of a viscosity gradient in the second case, in the sense of reducing the critical Reynolds number beyond which perturbations are amplified. This result supports the hypothesis that the current oscillations observed in the polarization curve may originate from a hydrodynamic instability.
Resumo:
Hepatitis A virus (HAV) replicates relatively slowly in cell culture without a cytopathic effect, a fact that limits the use of tissue culture assays. The radioimmunofocus assay is the standard method for HAV titration, although it is labor intensive and requires the use of radioisotopes. A simple, rapid and objective infectivity assay based on an in situ enzyme immunoassay (EIA) is described here for a Brazilian cell culture-adapted HAV strain (HAF-203). The assay uses a peroxidase-labeled polyclonal antibody to fixed monolayers as an indicator of infection. EIA may be completed within 7 days using serial 5-fold dilutions of the virus, yielding a titer of 5.024 log 50% tissue culture infective dose (TCID50)/ml for HAF-203. This technique had a detection limit of 1.1 log TCID50/ml and the specificity was demonstrated by detecting no reaction on the columns of uninfected wells. The reproducibility (with intra- and inter-assay coefficients of variation ranging from 1.9 to 3.8% and from 3.5 to 9.9%, respectively) and quantitation of the assay were demonstrated by close agreement in virus infectivity titers among different assays of the same amount of virus and between assays of different amounts of virus. Furthermore, this assay does not require the use of radiolabeled antibodies. We describe here an efficient EIA that is highly reproducible and that could be used to monitor HAV growth in cell culture and to determine the quantity of HAV antigen needed for diagnostic assays. This is the first report of the infectious titer of the Brazilian cell culture-adapted HAV strain (HAF-203).
Resumo:
Hepatitis E virus (HEV) is classified within the family Hepeviridae, genus Hepevirus. HEV genotype 3 (Gt3) infections are endemic in pigs in Western Europe and in North and South America and cause zoonotic infections in humans. Several serological assays to detect HEV antibodies in pigs have been developed, at first mainly based on HEV genotype 1 (Gt1) antigens. To develop a sensitive HEV Gt3 ELISA, a recombinant baculovirus expression product of HEV Gt3 open reading frame-2 was produced and coated onto polystyrene ELISA plates. After incubation of porcine sera, bound HEV antibodies were detected with anti-porcine anti-IgG and anti-IgM conjugates. For primary estimation of sensitivity and specificity of the assay, sets of sera were used from pigs experimentally infected with HEV Gt3. For further validation of the assay and to set the cutoff value, a batch of 1100 pig sera was used. All pig sera were tested using the developed HEV Gt3 assay and two other serologic assays based on HEV Gt1 antigens. Since there is no gold standard available for HEV antibody testing, further validation and a definite setting of the cutoff of the developed HEV Gt3 assay were performed using a statistical approach based on Bayes' theorem. The developed and validated HEV antibody assay showed effective detection of HEV-specific antibodies. This assay can contribute to an improved detection of HEV antibodies and enable more reliable estimates of the prevalence of HEV Gt3 in swine in different regions.
Resumo:
The primary aim of these investigations was to probe the spectroscopic, electrochemical, biological and single crystal X-ray diffraction studies of some selected transition metal complexes of 4N-monosubstituted thiosemicarbazones. Transition metal complexes with thiosemicarbazones exhibit a wide range of stereochemistries and possess potential biological activity. Metal complexes of thiosemicarbazones are proved to have improved pharmacological and therapeutic effects. The studies are conducted to bring about a fair understanding of the structure activity relationship and to develop certain effective and economical metal-based antimicrobial agents. Study showed that the thiosemicarbazones have antibacterial, antiviral and antiproliferative properties and hence used against tuberculosis, leprosy, psoriasis, rheumatism, trypanosomiasis and coccidiosis. Certain thiosemicarbazones showed a selective inhibition of HSV and HIV infections. The insolubility of most thiosemicarbazones in water causes difficulty in the oral administration in clinical practice. Transition metal complexes are found to have more activity than uncombined thiosemicarbazones. They exhibit a variety of denticity and can be varied by proper substitution. The stereochemistry assumed by the thiosemicarbazones during the coordination with transition metal ions depends on the factors such as preparative conditions and availability of additional bonding site in the ligand moiety and charge of the ligand. The resulting complexes exhibited a wide range of stereochemistries and have biomimic activity and potential application as sensors.
Resumo:
The primary aim of these investigations was to probe the spectroscopic, electrochemical, biological and single crystal X-ray diffraction studies of some selected transition metal complexes of 4N-monosubstituted thiosemicarbazones. Transition metal complexes with thiosemicarbazones exhibit a wide range of stereochemistries and possess potential biological activity. Metal complexes of thiosemicarbazones are proved to have improved pharmacological and therapeutic effects. The studies are conducted to bring about a fair understanding of the structure activity relationship and to develop certain effective and economical metal-based antimicrobial agents. Study showed that the thiosemicarbazones have antibacterial, antiviral and antiproliferative properties and hence used against tuberculosis, leprosy, psoriasis, rheumatism, trypanosomiasis and coccidiosis. Certain thiosemicarbazones showed a selective inhibition of HSV and HIV infections. The insolubility of most thiosemicarbazones in water causes difficulty in the oral administration in clinical practice. Transition metal complexes are found to have more activity than uncombined thiosemicarbazones. They exhibit a variety of denticity and can be varied by proper substitution. The stereochemistry assumed by the thiosemicarbazones during the coordination with transition metal ions depends on the factors such as preparative conditions and availability of additional bonding site in the ligand moiety and charge of the ligand. The resulting complexes exhibited a wide range of stereochemistries and have biomimic activity and potential application as sensors
Resumo:
A metalloporphyrin incorporated carbon paste sensor has been developed for the determination of metronidazole benzoate (MTZB). Zn(II) complex of 5,10,15,20-tetrakis (3-methoxy-4-hydroxy phenyl) porphyrin (TMHPP) was used as the active material. The MTZB gave a well-defined reduction peak at - 0.713V in 0.1 mol l -1 phosphate buffer solution of pH around 7. Compared with bare carbon paste electrode (CPE), the TMHPP Zn(II) modified electrode significantly enhanced the reduction peak current of MTZB as well as lowered its reduction potential. Under optimum conditions the reduction peak current was proportional to MTZB concentration over the range 1×10-3 mol1-1 to 1×10-5mol1-1. The detection limit was found to be 4.36×10-6mol1-1 . This sensor has been successfully applied for the determination of MTZB in pharmaceutical formulations and urine samples.
Resumo:
Poly(6-tert-butyl-3,4-dihydro-2H-1,3-benzoxazine) was synthesized by thermally activated cationic ring opening polymerization. The structure of the polymer was confirmed by spectral and thermal studies. The highest occupied molecular orbital (HOMO) and lowest unoccupied molecular orbital (LUMO) were estimated using cyclic voltammetry and optical absorption. Modulated photocurrent measurement technique was employed to study the spectral and field dependence of photocurrent. Photocurrent of the order of 1.5 micro A/m2 was obtained for polymer at a biasing electric field of 40 V/mico m.
Resumo:
Voltammetric sensors are an important class of electrochemical sensors in which the analytical information is obtained from the measurement of current obtained as a result of electrochemical oxidation/reduction.This current is proportional to the concentration of the analyte.Chemically modified electrodes(CMEs) have great significance as important analytical tools for the electrochemical determination of pharmaceuticals.The modification of electrode results in efficient determination of electro-active biomolecules at very lower potential without its major interferences.The operation mechanism of CMEs depends on the properties of the modifier materials that are used to promote selectivity towards the target analytes.Modified electrodes can be prepared by deposition of various compounds such as organic compounds ,conducting polymers,metal oxides,etc. on the various electrode surfaces.The thesis presents the development ,electrochemical characterization and analytical application studies of eight voltammetric sensors developed for six drugs viz.,Ambroxol,Sulfamethoxazole,PAM Chloride, Lamivudine,Metronidazole and Nimesulide.The modification techniques adopted as part of the present work include Multiwalled Carbon Nanotube(MWCNT) based modification.Electropolymerisation and Gold Nanoparticle (AuNP) based modifications.