695 resultados para Disinfection byproducts


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Exposure to certain fungi (molds) can cause human illness by 3 specific mechanisms: generation of a harmful immune response, direct infection by the organism or/and toxic-irritant effects from mold byproducts. Moulds are considered central elements in daily exposure of poultry workers and can be the cause of an increased risk of occupational respiratory diseases, like allergic and non-allergic rhinitis and asthma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Os polifenóis constituem um grupo biologicamente relevante de compostos naturais, que têm gerado um crescente interesse por parte dos consumidores e das indústrias alimentar, farmacêutica e de cosméticos. Os compostos fenólicos exibem uma vasta gama de propriedades fisiológicas, tais como anti-alérgica, anti-aterogénica, anti-inflamatória, anti-microbiana, antioxidante, anti-trombótica, possuindo efeitos cardio-protetores e vasodilatadores. Por conseguinte, o interesse na obtenção deste compostos ativos de uma forma fácil, barata e rápida tem vindo a aumentar. Uma das fontes de polifenóis são os subprodutos agrícolas, tais como os produtos derivados do vinho e/ou processamento de uvas. As folhas, os caules e os resíduos obtidos durante o processo de produção do vinho têm sido subutilizados, apesar de representarem uma boa fonte de compostos antioxidantes e bioativos. Portugal é um dos mais importantes países produtores de vinho, onde todos os anos são geradas várias toneladas de subprodutos associados a esta indústria. A extração, caracterização, quantificação e avaliação da atividade antioxidante de compostos bioativos extraídos destes subprodutos são, pois, tarefas importantes a fim de avaliar o potencial de utilização destes produtos como novas fontes de compostos antioxidantes. O objetivo deste trabalho foi quantificar e avaliar os teores de polifenóis de extratos preparados a partir de folhas e caules de videira, e bagaço, engaço e grainha de uva. Os parâmetros experimentais da extração foram otimizados, incluindo a proporção de solvente de extração (água/etanol), a temperatura e o tempo de extração. A quantificação dos polifenóis (como fenóis totais e flavonoides) foi efetuada por espetrofotometria de UV/Vis. Verificou-se que a melhor razão de solventes extratores foi de 50/50 (v/v) em água/etanol para todos os subprodutos estudados. No caso dos subprodutos folhas e caules, as condições ideais de extração foram obtidas quando se usou uma temperatura de 40ºC e um tempo de extração de 30 min. Para o bagaço, a temperatura ideal foi de 55ºC durante 5 min. Para o engaço e grainha a utilização de uma temperatura de 40ºC durante 5 min e 30 min, respetivamente, revelou-se o ideal para se obter os compostos. Com este trabalho conclui-se que os subprodutos da vinha e do vinho efetivamente possuem compostos de elevado valor e com capacidade antioxidante.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tendo em conta a contaminação normal de compostos azotados existente na água de uma piscina, derivados na sua maioria do próprio banhista, é inevitável a formação de subprodutos, quando estes reagem com o cloro como desinfectante. De todos os subprodutos de desinfecção que se formam, as cloraminas, incluídas no controlo químico da água de piscina no parâmetro cloro combinado, são as mais conhecidas. Estes compostos são responsáveis por irritações oculares, das mucosas e do trato respiratório. São estes os compostos responsáveis pelo comummente designado ‘cheiro a cloro’ característico de muitas piscinas. Para além destes efeitos nefastos da sua presença na água, estes compostos possuem um poder desinfectante muito menor ao do ácido hipocloroso, a forma activa do cloro com maior capacidade desinfectante. Por todas estas razões, uma piscina com uma concentração de cloro combinado elevada não é adequada para uso. Com a premissa comprovada em diversos estudos do uso de zeólitos para diminuição de compostos amoniacais por adsorção, é objectivo deste estudo comprovar a sua viabilidade no uso da redução destes compostos nas águas de piscinas. Para tal, foram realizados estudos em contínuo, numa piscina piloto onde foram aplicados hipoclorito de sódio e amoníaco, e ensaios em descontínuo, para que fosse determinada a capacidade e o tempo necessário ao equilíbrio de adsorção para este par adsorvente/adsorvato. Nos ensaios em contínuo, a clinoptilolite adsorveu 1,652 g Cl2/kg de clinoptilolite, em aproximadamente 300 horas de funcionamento, a 23,5 ºC. Nos ensaios em descontínuo, foram estudadas diferentes concentrações iniciais de cloro combinado. Os ensaios foram realizados a 20 ºC. Para uma concentração inicial de 4,06 mg/L Cl2, obteve-se uma capacidade de adsorção de 0,28 g Cl2/kg de clinoptilolite, ao fim de 360 horas. Para uma concentração inicial de 2 mg / L Cl2, o ensaio teve uma duração de 360 horas, e não se verificou estabilização. No entanto, findo este tempo, ocorreu a adsorção de 0,28 g Cl2/kg de clinoptilolite. Para uma concentração inicial de 0,56 mg/L Cl2, obteve-se um valor inferior, de 0,027 g Cl2/kg de clinoptilolite ao fim de 168 horas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A empresa Petibol, S.A. – Embalagens de plástico centra-se na produção de embalagens de plástico a partir da matéria-prima Poliestireno Expandido (EPS) e Polipropileno Expandido (EPP). A empresa possui uma preocupação ao nível da qualidade da água e do aproveitamento energético, tendo desta forma surgido a realização do estudo na unidade industrial, com o objectivo de anular e/ou diminuir as possíveis lacunas existentes na unidade industrial. Numa primeira etapa foi realizada uma caracterização global à qualidade da água e à empresa, actualizando-se os esquemas já existentes, contabilizando-se os custos actuais relativamente aos processos no circuito da água (arrefecimento, aquecimento e pressurização), e por fim, efectuou-se um levantamento in loco do circuito de água, relativamente à pressão, temperatura e caudal. Numa fase posterior, foram propostos equipamentos e processos, tendo em vista a colmatação dos problemas identificados, realizando-se um subsequente estudo relativamente aos custos inerentes a esses novos processos. A caracterização à água foi avaliada em diferentes pontos do circuito industrial, tendo-se determinado na Sala de Bombagem que o filtro de areia não possuía as dimensões mais apropriadas, existindo também um problema a nível mecânico associado ao processo de contra-lavagem. Tais factos podem ser a causa da ocorrência de um aumento do teor de sólidos após a passagem na camada filtrante. Relativamente ao amaciador, este deveria amaciar de forma completa a água para alimentação à caldeira, embora se tenha registado à saída do amaciador uma dureza de 21,3 mg/L, denunciando problemas na troca iónica. No que toca à água de alimentação à caldeira, verifica-se a existência de parâmetros que não se encontram de acordo com os critérios enunciados para uma óptima qualidade, sendo eles o pH (10,14), condutividade (363 μS/cm), teor de ferro (1,21 mg/L) e a dureza (16 mg/L). De salientar que somente o teor de cobre, que se encontra em quantidades vestigiais, apresenta-se de acordo com os valores impostos. No que respeita à água da caldeira, esta apresenta parâmetros incompatíveis com os recomendados, sendo eles a condutividade (7350 μS/cm), teor de sólidos dissolvidos (5248 mg/L) e alcalinidade total (780 mg/L). De referir que o valor de pH (11,8) não se encontra de acordo com a aplicação do tratamento “fosfato-pH coordenado”. Em relação aos parâmetros com valores que se encontram dentro dos limites, estes correspondem à dureza (0 mg/L), ao teor de fosfatos (45 mg/L) e teor de sílica (0 mg/L). A água do circuito de arrefecimento foi sujeita a uma análise microbiológica, que corroborou a presença de um biofilme. Um dos problemas enunciados pela empresa, prendia-se com a impossibilidade de descarga, no colector municipal, dos condensados dos compressores, visto apresentarem uma quantidade de óleo de cerca de 43,3 mg/L, equivalente a quatro vezes o valor limite de emissão, de acordo com a legislação municipal. Por fim, o efluente de descarga industrial apresenta um valor de pH (10,3) acima do intervalo permitido por lei (6,0 – 9,0), sendo que a corrente que mais contribui para este acréscimo de pH corresponde à corrente proveniente da água de purga, visto esta apresentar um valor de pH de 12,22. De maneira a contornar os parâmetros enunciados, é proposto a substituição do filtro de areia da Sala de Bombagem, assim como a inserção de um conjunto de medidas de remoção de ferro e desinfecção, sendo a conjugação de arejamento, coagulação, filtração e desinfecção, por parte do hipoclorito, a proposta apresentada. Aos condensados dos compressores é apresentado um sistema de separação, que possibilita a remoção do óleo da água, e uma consequente descarga da mesma. Actualmente, não existe qualquer filtro de areia no circuito de arrefecimento da água, sendo proposto assim esse equipamento, de forma a minorar o desenvolvimento da população microbiana, bem como a permitir uma maior eficiência na transferência de calor na torre de arrefecimento. Relativamente à descarga industrial, é recomendável a colocação de um sistema de regularização automática de pH. A inserção de uma válvula de três vias permite um aproveitamento energético e de água, a partir da confluência da água oriunda dos furos com a água do tanque de água fria, sendo posteriormente alimentada à central de vácuo. No estudo da recuperação energética, um outro equipamento avaliado correspondeu à serpentina, no entanto, verificou-se que a poupança no consumo de gás natural era de apenas 0,005%, o que não se mostrou uma proposta viável. O orçamento de todos os equipamentos é de 11.720,76 €, possibilitando não só um melhor funcionamento industrial, como um menor impacto a nível ambiental. Os custos futuros de funcionamento aumentam em 3,36%, tendo a pressurização um aumento do seu custo em 3,4% em relação ao custo actual, verificando-se um custo anual de 10.781,21€, em relação aos processos de arejamento, coagulação e desinfecção.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The consumption of natural products has become a public health problem, since these medicinal teas are prepared using natural plants without an effective hygienic and sanitary control. The aim of this study was to assess the effects of gamma radiation, on the microbial burden of two medicinal plants: Melissa officinalis and Lippia citriodora. Dried samples of the two plants were irradiated at a Co-60 experimental equipment. The applied gamma radiation doses were 1, 3, and 5 kGy at a dose rate of 1.34 kGy/h. Non-irradiated samples followed all the experiments. Bacterial and fungal counts were assessed before and after irradiation by membrane filtration method. Challenging tests with Escherichia coli were performed in order to evaluate the disinfection efficiency of gamma radiation treatment. Characterization of M. officinalis and L. citriadora microbiota indicated an average bioburden value of 102CFU/g. The inactivation studies of the bacterial mesophilic population of both dried plants pointed out to a one log reduction of microbial load after irradiation at 5 kGy. Regarding the fungal population, the initial load of 30 CFU/g was only reduced by 0.5 log by an irradiation dose of 5 kGy. The dynamics with radiation doses of plants microbial population’s phenotypes indicated the prevalence of gram-positive rods for M. officinalis before and after irradiation, and the increase of the frequency of gram-negative rods with irradiation for L. citriadora. Among fungal population of both plants, Mucor, Neoscytalidium, Aspergillus and Alternaria were the most isolated genera. The results obtained in the challenging tests with E. coli on plants pointed out to an inactivation efficiency of 99.5% and 99.9% to a dose of 2 kGy, for M.officinalis and L. citriadora, respectively. The gamma radiation treatment can be a significant tool for the microbial control in medicinal plants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Engenharia Química. Ramo optimização energética na indústria química

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The development and applications of thermoset polymeric composites, namely fiber reinforced polymers (FRP), have shifted in the last decades more and more into the mass market [1]. Production and consume have increased tremendously mainly for the construction, transportation and automobile sectors [2, 3]. Although the many successful uses of thermoset composite materials, recycling process of byproducts and end of lifecycle products constitutes a more difficult issue. The perceived lack of recyclability of composite materials is now increasingly important and seen as a key barrier to the development or even continued used of these materials in some markets.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trihalomethanes (THMs) are widely referred and studied as disinfection by-products (DBPs). The THMs that are most commonly detected are chloroform (TCM), bromodichloromethane (BDCM), chlorodibromomethane (CDBM), and bromoform (TBM). Several studies regarding the determination of THMs in swimming pool water and air samples have been published. This paper reviews the most recent work in this field, with a special focus on water and air sampling, sample preparation and analytical determination methods. An experimental study has been developed in order to optimize the headspace solid-phasemicroextraction (HS-SPME) conditions of TCM, BDCM, CDBM and TBM from water samples using a 23 factorial design. An extraction temperature of 45 °C, for 25min, and a desorption time of 5 min were found to be the best conditions. Analysis was performed by gas chromatography with an electron capture detector (GC-ECD). The method was successfully applied to a set of 27 swimming pool water samples collected in the Oporto area (Portugal). TCM was the only THM detected with levels between 4.5 and 406.5 μg L−1. Four of the samples exceeded the guideline value for total THMs in swimming pool water (100 μgL−1) indicated by the Portuguese Health Authority.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The cleaning of syngas is one of the most important challenges in the development of technologies based on gasification of biomass. Tar is an undesired byproduct because, once condensed, it can cause fouling and plugging and damage the downstream equipment. Thermochemical methods for tar destruction, which include catalytic cracking and thermal cracking, are intrinsically attractive because they are energetically efficient and no movable parts are required nor byproducts are produced. The main difficulty with these methods is the tendency for tar to polymerize at high temperatures. An alternative to tar removal is the complete combustion of the syngas in a porous burner directly as it leaves the particle capture system. In this context, the main aim of this study is to evaluate the destruction of the tar present in the syngas from biomass gasification by combustion in porous media. A gas mixture was used to emulate the syngas, which included toluene as a tar surrogate. Initially, CHEMKIN was used to assess the potential of the proposed solution. The calculations revealed the complete destruction of the tar surrogate for a wide range of operating conditions and indicated that the most important reactions in the toluene conversion are C6H5CH3 + OH <-> C6H5CH2 + H2O, C6H5CH3 + OH <-> C6H4CH3 + H2O, and C6H5CH3 + O <-> OC6H4CH3 + H and that the formation of toluene can occur through C6H5CH2 + H <-> C6H5CH3. Subsequently, experimental tests were performed in a porous burner fired with pure methane and syngas for two equivalence ratios and three flow velocities. In these tests, the toluene concentration in the syngas varied from 50 to 200 g/Nm(3). In line with the CHEMKIN calculations, the results revealed that toluene was almost completely destroyed for all tested conditions and that the process did not affect the performance of the porous burner regarding the emissions of CO, hydrocarbons, and NOx.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

No presente relatório é apresentado um estudo, realizado na forma de estágio curricular, na empresa Águas do Douro e Paiva, S.A., doravante AdDP, entre 31 de Janeiro e 31 de Julho de 2014, sobre reabilitação interior de reservatórios para água potável. Inicialmente é feito um enquadramento ao tema, com uma abordagem às características genéricas dos reservatórios de água potável e às principais patologias que se verificam no interior desses reservatórios. De seguida, são detalhadas as principais técnicas de reabilitação interior existentes, de acordo com o tipo de patologias encontradas. Como complemento a esse estudo, são apresentados os principais fornecedores e os produtos mais utilizados em cada fase da reabilitação, de acordo com a pesquisa realizada e com as reuniões presenciadas. Por fim, são ainda apresentadas, as principais considerações a ter em conta na lavagem e desinfeção de reservatórios. Atendendo à problemática em causa, foi desenvolvida uma ficha técnica para cada reservatório que, além da sistematização das características principais, tem o objetivo de registar todas as intervenções de reabilitação ou de conservação que possam ocorrer no mesmo. Para tal, foi feito um acompanhamento dos problemas e intervenções verificadas, e surgiu, ainda, a oportunidade de acompanhar o processo de lançamento a concurso das obras de reabilitação que surgiram dessa caracterização. Por fim, foi explorada a componente de gestão patrimonial de infraestruturas, com o desenvolvimento de uma matriz de risco qualitativa, específica para aplicação aos reservatórios da AdDP, com o objetivo de constituir uma ferramenta de apoio à decisão e planeamento das intervenções de reabilitação interior. Embora fora do contexto da reabilitação interior de reservatórios, é de assinalar a importante experiência proporcionada no acompanhamento da obra de alargamento do sistema multimunicipal de abastecimento de água ao concelho de Amarante, que incluiu a instalação de conduta e construção de duas estações elevatórias.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUMO - Os trabalhadores dos ginásios com piscinas apresentam maior prevalência de lesões fúngicas, como a Tinea pedis e a onicomicose, devido às características intrínsecas da sua actividade profissional, pois apresentam mais horas por dia de exposição à contaminação fúngica das superfícies. Esta situação verifica-se não só por serem os que mais frequentam os locais possíveis de estarem contaminados, como é o caso de balneários, vestiários e zona envolvente às piscinas, mas também porque algumas das actividades desenvolvidas são realizadas com os pés descalços. Além disso, a utilização de roupa sintética e de calçado ocluso, que retêm a sudação excessiva, favorece o desenvolvimento fúngico. Constituiu objectivo deste trabalho conhecer o risco de infecção e/ou lesão (Tinea pedis e onicomicose) nos trabalhadores dos ginásios com piscina e a sua eventual relação com a exposição à contaminação fúngica (ar e superfícies) dos locais de trabalho. Foram descritas as variáveis ambientais e biológicas que influenciam a infecção e/ou lesão fúngica em ambiente profissional e exploradas eventuais associações entre essas mesmas variáveis. Foram também conhecidas as diferenças da contaminação fúngica das superfícies entre as duas principais estações do ano (Verão e Inverno) e entre antes e depois da lavagem e desinfecção. O estudo realizado possui uma componente transversal, em que se pretendeu descrever os fenómenos ambientais e biológicos da contaminação fúngica em ambiente profissional e explorar eventuais associações entre variáveis; uma componente longitudinal, em que foram conhecidas as diferenças sazonais da contaminação fúngica das superfícies; e, ainda, uma componente quase experimental, em que foi analisada a distribuição fúngica nas superfícies antes e depois da lavagem e desinfecção. Na vertente transversal foi considerada uma amostra de 10 ginásios com piscina e outra amostra de, pelo menos, 10 profissionais de cada estabelecimento, perfazendo um total de 124 trabalhadores (75 Homens - 60,48% e 49 Mulheres - 39,52%). Foram realizadas 258 colheitas biológicas aos pés dos trabalhadores, efectuada a avaliação ambiental da contaminação fúngica dos estabelecimentos através de 50 colheitas de amostras de ar e 120 colheitas de amostras de superfícies (60 antes e 60 depois da lavagem e desinfecção) e efectuados os respectivos processamento laboratorial e identificação fúngica. Foram também avaliadas as variáveis ambientais temperatura, humidade relativa e velocidade do ar, preenchidas 10 grelhas de observação, com o objectivo de efectuar o registo de informação sobre as variáveis que xx influenciam a exposição ocupacional às espécies fúngicas e, ainda, completadas 124 grelhas de observação inerentes à colheita de material biológico, de modo a realizar o registo dos profissionais com lesão e outras informações pertinentes para a análise laboratorial. Todos os 124 trabalhadores responderam a um questionário, em simultâneo à realização das colheitas biológicas, de modo a conhecer algumas das variáveis individuais e profissionais com pertinência para o presente estudo. Num dos estabelecimentos, foram também estudadas as diferenças da contaminação fúngica das superfícies entre antes e depois da lavagem e desinfecção e, ainda, entre as duas estações do ano (Verão e Inverno). Nesse estabelecimento, foram realizadas 36 colheitas de superfícies antes e 36 colheitas depois da lavagem e desinfecção, em 6 dias diferentes da semana, durante 6 semanas sequenciais em cada estação do ano, completando um total de 72 colheitas de superfícies. Foi ainda criado e aplicado um método para estabelecer um padrão de exposição profissional a fungos nas superfícies, de modo a permitir definir níveis semi-quantitativos de estimação do risco de infecção fúngica dos trabalhadores dos ginásios com piscinas. Para o critério da Gravidade, considerou-se que a gravidade da contaminação e, consequentemente, da possível lesão, está intimamente relacionada com a espécie fúngica envolvida. Foram calculadas as médias da contaminação fúngica por cada estabelecimento antes da lavagem e desinfecção, de modo a estabelecer os níveis de Frequência e, em relação à Exposição, foram estabelecidos intervalos para agrupar as horas semanais de trabalho. Dos 124 trabalhadores que participaram no estudo, 58 (46,8%) possuíam lesões visíveis. Nesses 58, as Leveduras foram as mais isoladas (41,4%), seguidas dos Dermatófitos (24,1%) e de Fungos Filamentosos Não Dermatófitos (6,9%). Candida parapsilosis e Rhodotorula sp. foram as Leveduras mais frequentemente isoladas (20,2%); no caso dos Dermatófitos, Trichophyton rubrum foi a espécie mais frequente (55,5%) e, relativamente aos Fungos Filamentosos Não Dermatófitos, Penicillium sp. foi o mais isolado (15,6%), seguido do género Fusarium (12,5%). No que concerne à contaminação fúngica das superfícies, 37 fungos filamentosos foram isolados. Fusarium foi o género mais frequente, antes e depois da lavagem e desinfecção (19,1% - 17,2%). Em relação aos fungos leveduriformes, 12 leveduras diferentes foram identificadas, tendo sido os géneros Cryptococcus (40,6%) e Candida (49,3%) os mais frequentes antes e depois da lavagem e desinfecção, respectivamente. Em relação à contaminação fúngica do ar, foram identificados 25 fungos filamentosos diferentes, em que os 3 géneros mais frequentemente isolados foram Cladosporium (36,6%), Penicillium (19,0%) e Aspergillus (10,2%). Relativamente às leveduras, foi identificado o género xxi Rhodotorula (87,5%) e as espécies Trichosporon mucoides e Cryptococcus unigutulattus (12,5%). Verificou-se associação, ao nível de significância de 5%, entre lesão visível e horas semanais e entre lesão visível e tempo de profissão, comprovando a influência da duração da exposição ao factor de risco (contaminação fúngica do ambiente profissional), para a presença de lesão visível nos trabalhadores expostos (Tinea pedis e onicomicose), ficando demonstrada a relação entre a exposição ao factor de risco em estudo – exposição profissional a fungos – com os efeitos para a saúde. As variáveis ambientais avaliadas (temperatura, humidade relativa e velocidade do ar) não influenciaram a contaminação fúngica do ar e das superfícies, não tendo sido evidenciada nenhuma relação estatisticamente significativa (p>0,05). Contudo, verificou-se influência do número de ocupantes que frequentaram cada um dos estabelecimentos nas médias das unidades formadoras de colónias por metro quadrado nas superfícies antes da lavagem e desinfecção. Não se verificou correlação entre os resultados quantitativos da contaminação fúngica do ar e a das superfícies dos 10 estabelecimentos monitorizados. No entanto, verificaram-se diferenças significativas, ao nível de significância de 10%, entre a contaminação fúngica das superfícies e a contaminação fúngica do ar (p<0,1), tendo-se constatado que apesar de 50% dos valores mais baixos terem sido superiores na contaminação fúngica do ar, a contaminação fúngica das superfícies apresentou-se com maior variabilidade quantitativa. Em relação às diferenças significativas na contaminação fúngica das superfícies nos 10 estabelecimentos entre antes e depois da lavagem e desinfecção, apenas se verificou redução significativa (p<0,05) da contaminação fúngica depois da lavagem e desinfecção nos balneários e vestiários masculinos em relação aos fungos leveduriformes. No estabelecimento seleccionado, verificou-se que a relação entre a contaminação fúngica e a temperatura e humidade relativa não foi significativa (p>0,05) em ambas as estações do ano e também não se constatou influência dos ocupantes nos valores médios das unidades formadoras de colónias por metro quadrado das superfícies antes da lavagem e desinfecção em ambas as estações de ano. Em quase todas as situações em que se verificaram diferenças significativas entre as duas estações do ano, verificou-se um aumento das unidades formadoras de colónias por metro quadrado no Inverno, com excepção do total das unidades formadoras de colónias por metro quadrado antes da lavagem e desinfecção nos balneários e vestiários masculinos em que se verificou aumento no Verão. Constatou-se também que apenas ocorreu redução da xxii contaminação fúngica depois da lavagem e desinfecção nas escadas de acesso no Inverno e nos balneários e vestiários masculinos no Verão. Com a aplicação do método para estabelecer um padrão de exposição profissional a fungos nas superfícies obteve-se, nos 10 estabelecimentos, com Nível de Risco Mínimo 65 locais (54,2%), com Nível de Risco Médio 23 locais (19,2%) e com Nível de Risco Elevado 32 locais (26,6%). Próximo do jacuzzi e junto ao tanque foram os locais com mais classificações de Nível de Risco Elevado. No estabelecimento seleccionado verificou-se que, no Verão, depois da lavagem e desinfecção, ocorreu um maior número de locais classificados no Nível de Risco Elevado e, no Inverno, constatou-se a situação inversa, tendo sido observado maior número de locais com Nível de Risco Elevado antes da lavagem e desinfecção. Junto ao tanque e nas escadas de acesso à zona envolvente ao jacuzzi e tanque foram os locais com mais classificações de Nível de Risco Elevado, no Verão e no Inverno. Foram isolados nas superfícies fungos comuns aos isolados nos trabalhadores. Antes da lavagem e desinfecção, 30,3% dos fungos foram isolados nas superfícies e nos trabalhadores e depois desses procedimentos 45,5% dos fungos foram também isolados comummente. As Leveduras foram as mais isoladas comummente e as que se verificaram mais frequentes antes e depois da lavagem e desinfecção da superfícies e, também, nos resultados das colheitas biológicas realizadas aos trabalhadores, foram o género Rhodotorula e a espécie Candida parapsilosis, permitindo confirmar que a infecção fúngica dos trabalhadores está relacionada com a contaminação fúngica das superfícies. Concluiu-se que é necessária a intervenção em Saúde Ocupacional no âmbito da vigilância ambiental e da vigilância da saúde, com o intuito de diminuir a prevalência das infecções fúngicas. Para a prossecução desse objectivo, sugere-se a implementação de medidas preventivas, nomeadamente: o controlo da contaminação fúngica das superfícies mediante procedimentos de lavagem e desinfecção eficazes, de modo a minimizar a contaminação fúngica das superfícies; a identificação precoce da infecção através da realização de colheitas biológicas periódicas aos trabalhadores, inseridas num protocolo de vigilância da saúde; e, ainda, a sensibilização para a aplicação de medidas de higiene pessoal e o tratamento das patologias. A aplicação do método criado para estabelecer um padrão de exposição profissional a fungos nas superfícies servirá não só para a estimação do risco de infecção fúngica dos trabalhadores de ginásios com piscinas, mas também para facilitar o estabelecimento de valores fúngicos de referência, a implementação de medidas correctivas adequadas e imediatas e, ainda, a prevenção de infecções fúngicas, não só nos ginásios com piscina, mas também noutros contextos profissionais. ------------ SUMMARY - Gyms with swimming pools workers have higher prevalence of fungal injuries, such as Tinea pedis and onychomycosis. This is due to their work intrinsic characteristics, since they have more hours per day of exposure to surfaces fungal contamination. This occurs not only because they attend sites most likely to be contaminated, such as showers, changing rooms and pool surrounding area, but also because some of the activities are done barefoot. Furthermore, synthetic clothing and occluded footwear use, which retain the excessive sweating, promotes fungal development. The aim of this study was to know gymnasiums with swimming pool workers infection and/or injury (Tinea pedis and onychomycosis) risk, and its possible relationship with exposure to workplace fungal contamination (air and surfaces). This study describes environmental and biological variables that influence infection and/or fungal injury in a professional setting and explored possible associations between these variables. Differences in surfaces fungal contamination between the two main seasons (summer and winter), as well between before and after cleaning and disinfection were known. It was developed a study with an cross-sectional perspective, that aimed to describe the biological and environmental phenomena of fungal contamination in a professional environment and explore possible associations between variables; an longitudinal perspective in which were known surfaces fungal contamination seasonal differences; and also with an almost experimental perspective that analyzed surfaces fungal distribution before and after cleaning and disinfection. The cross-sectional perspective comprised 10 gyms with swimming pool sample, and another sample of, at least, 10 professionals in each establishment totalling 124 workers (75 men – 60,48%, and 49 women – 39,52%). Were performed 258 biological samples at workers feet, environmental fungal contamination evaluation from the establishments through 50 air samples and 120 surfaces samples (60 before and 60 after cleaning and disinfection) and conducted their laboratory processing and fungal identification. Were also evaluated environmental variables, such as temperature, relative humidity and air velocity completed 10 observation grids, in order to obtain data about variables that affect occupational exposure to fungal species, and also completed 124 observation grids inherent to biological material collection, in order to know the professionals with injury and other relevant information for laboratory analysis. All 124 workers answered to a questionnaire at the same time that occur biological samples collection, in order to xxv obtain information about some of the individual and professional variables with relevance to this study. In one of the establishments were also studied differences concerning surfaces fungal contamination between before and after cleaning and disinfection, and also between two main seasons (summer and winter). In this setting, there were performed 36 surfaces samples before and 36 surfaces samples after cleaning and disinfection on 6 different week days for 6 sequential weeks in each season, totalling 72 surfaces samples. It was also created and implemented a method to establish a pattern for surfaces fungal occupational exposure, in order to help define semi-quantitative levels estimation to fungal infection risk in gyms with swimming pools workers. For Gravity criterion it was considered that contamination severity and, thus, the possible injury are closely related to implicate fungal species. Was calculated fungal contamination average by each establishment prior cleaning and disinfection, in order to establish Frequency levels. Regarding Exposure, were established weekly hours group intervals spent in professional activity. From the 124 professionals tested, 58 (46,8%) had visible injuries. In the 58 workers, Yeasts were the most isolated (41,4%), followed by Dermatophytes (24,1%) and Other Filamentous Fungi Besides Dermatophytes (6,9%). Candida parapsilosis and Rhodotorula sp. were the most frequently isolated Yeasts (20,2% for each), from Dermatophytes, Trichophyton rubrum was the most frequently isolated species (55,5%) and from Other Filamentous Fungi Besides Dermatophytes, Penicillium sp. was the most frequent (15,6%), followed by Fusarium genera (12,5%). Regarding surfaces fungal contamination, 37 filamentous fungi were isolated. Fusarium genera was the most frequent, before and after cleaning and disinfection (19,1% - 17,2%). Considering yeasts, 12 different yeasts were identified, being Cryptococcus (40,6%) and Candida (49,3%) genera the more frequent before and after cleaning and disinfection, respectively. In relation to air fungal contamination, 25 different filamentous fungi were identified and the 3 most frequently isolated genera were Cladosporium (36,6%), Penicillium (19,0%) and Aspergillus (10,2%). For yeasts, were identified Rhodotorula genera (87,5%), and also the species Trichosporon mucoides and Cryptococcus unigutulattus (12,5%). Was found association with 5% significance level, between visible injury and weekly hours and between visible injury and occupation time, confirming exposure duration influence to risk factor (work environment fungal contamination) for the visible injury presence in exposed workers (Tinea pedis and onychomycosis), being confirmed the relation between the study exposure risk - occupational exposure to fungi - with health effects. xxvi Environmental variables evaluated (temperature, relative humidity and air velocity) did not affect air and surfaces fungal contamination and wasn’t found no statistically significant relation (p>0,05). However, there was evidence that occupant’s number influence surfaces colony forming units mean per square meter before cleaning and disinfection. There was no correlation between quantitative data from air fungal contamination and surfaces fungal contamination from the 10 establishments monitored. However, there were significant differences with 10% significance level, between surfaces and air fungal contamination (p<0,1), and despite 50% of the lowest rates were higher in air fungal contamination, it was found that surfaces fungal contamination had more quantitative variability. Regarding differences from the 10 establishments surfaces fungal contamination, between before and after cleaning and disinfection, there was only a significant reduction (p<0,05) in fungal contamination after cleaning and disinfection in male changing rooms for yeasts. In the selected establishment, it was found that relation between fungal contamination and temperature and relative humidity was not significant (p>0,05) in both seasons, and also there wasn’t no influence observed from occupants in surfaces colony forming units mean per square meters before cleaning and disinfection in both seasons. In almost all situations where significant differences between the two seasons were shown, there was a colony-forming units per square meter increase in winter. There was an exception in total colony forming units per square meter before cleaning and disinfection in male changing room’s exception, where there was an increase in summer. Furthermore, was found that only occur a reduction in fungal contamination after cleaning and disinfection, on access stairs in winter, as well as in male changing rooms in summer. With application from the method to establish pattern for surfaces fungal occupational exposure, it was obtained, in the 10 establishments, 65 sites with Low Risk Level (54,2%), 23 sites with Average Risk Level (19,2%) and 32 sites with High Risk Level (26,6%). Near swimming pool and jacuzzi were the places with more High Risk Level classifications. In the selected establishment, was found that in the summer, after cleaning and disinfection, there were a greater number of sites classified as High Risk Level, and in winter it was found the opposite situation, being noted more places with High Risk Level before cleaning and disinfection. Next to swimming pool and access stairs to swimming pool and jacuzzi were the places with more High Risk Level classifications in Summer and Winter. Were isolated common fungi in surfaces and in workers. Prior to cleaning and disinfection 30,3% of fungi were isolated on surfaces and workers, and after 45,5% of fungi were also xxvii commonly isolated. The Yeasts were the most commonly isolated and the most frequent before and after surfaces cleaning and disinfection, and also in workers biological samples, were Rhodotorula genera and Candida parapsilosis, allowing confirming that workers fungal infection is related with surfaces fungal contamination. It was concluded that Occupational Health intervention it is necessary, in environmental monitoring and health surveillance perspective, in order to reduce fungal infections prevalence. To achieve this objective, preventive measures implementation it’s recommended, including: surfaces fungal contamination control, through effective cleaning and disinfecting in order to minimize surfaces fungal contamination; early infection identification by performing periodic biological sampling from workers, included in a health surveillance protocol; and also personal hygiene and diseases treatment awareness. Application of the created method to establish pattern for surfaces fungal occupational exposure, will be useful not only for estimating workers from gymnasiums with swimming pools fungal infection risk, but also to facilitate fungal reference values stipulation, effective and corrective measures implementation, and also, fungal infections prevention, not only in gymnasiums with swimming pool, but also in other professional settings.----------------- RÉSUMÉ - Les travailleurs des gymnases avec des piscines présentent souvent des infections fongiques, telles que Tinea pedis et aussi des onychomycoses, dues à leur activité professionnel, parce qu’ils restent plus longtemps tout prés des surfaces avec une certaine contamination fongique. Toute cette situation est due non seulement parce qu’ils sont ceux qui fréquentent plus souvent les places plus contaminées: des balnéaires, des vestiaires et des zones autour des piscines, mais aussi ils réalisent des activités aux pieds nus ou avec des chaussures très fermés et encore quelques fois avec des vêtements synthétiques. Tout cela emmène à une grande sudation ce qui aidera au développement fongique. Un objective de ce travaille a été connaître le risque d’infection et/ou présence de lésion (Tinea pedis et des onychomycoses) dans les travailleurs des gymnases avec des piscines et leur éventuel rapport avec l’exposition à la contamination fongique (de l’air et des surfaces) dans leurs locaux de travaille. On a décrit aussi des variables d’environnement et biologiques qui ont une certaine influence dans les infections fongiques dans tout l’environnement professionnel et aussi approfondir des éventuels associations entre ces même variables. On a encore reconnu des différences de la contamination fongique avant et après des lavages et désinfection de ces surfaces. Aussi on a trouvé des différences de contamination en Été et en Hiver. Cet étude a un composante transversale, en visant la description des phénomènes de contamination fongique biologique et de l'environnement dans un environnement professionnel et l’étude des associations possibles entre les variables; une composante longitudinale dans laquelle ils étaient connus comme des variations saisonnières de la contamination fongique des surfaces, et même; un quasi-composante expérimentale, où elle a examiné la répartition des champignons surfaces avant et après le lavage et la désinfection. Dans la composante transversale on été considérés 1 échantillons de 10 gymnases avec des piscines et un autre échantillon de au moins 10 professionnels de chaque établissement dans un total 124 travailleurs (75 hommes - 60,48% et 49 femmes - 39,52%). On a réalisé 258 prélèvements aux pieds des travailleurs et on a effectué en simultané la validation par contamination fongique de l’environnement par 50 prélèvements de l’air et par 120 prélèvements de surfaces (60 avant et 60 après des lavages et des désinfections) et on a effectué leur traitement en laboratoire et l’identification fongique. On a fait aussi l’évaluation des variables de l’environnement, la température, l’humidité relative et la vitesse de l’air. On a remplie 10 tableaux xxix d’observation, avec l’objective d’obtenir des informations sur les variables qu’influenceront l’exposition occupationnel aux souches fongiques, et encore 124 tableaux d’observation liée au prélèvement du matériel biologique, pour réaliser le registre des professionnels avec des lésions et des autres informations pertinentes pour une analyse laboratoire. Tous ces 124 travailleurs ont rempli un questionnaire au même temps que les prélèvements biologiques, afin de connaître quelques variables individuels et professionnels importants pour cet étude. Dans un des établissements on a aussi étudié les différences fongiques des surfaces parmi avant et après les lavages et de la désinfection et encore parmi l’Été et l’Hiver. Dans ce même établissement on a réalisé 36 prélèvements des surfaces avant et 36 après des lavages et de la désinfection, pendant 6 jours différents de la semaine, pendant 6 semaines en chaque saison de l’année, dans un total de 72 prélèvements des surfaces. On a encore crié et appliqué une méthode pour établir un standard d’exposition professionnelle au fungi sur les surfaces, afin de permettre la définition des niveaux semi quantitative d’estimation des risques d’infection fongique des travailleurs des gymnases avec des piscines. Pour le critère de Gravité, il a été considéré que la gravité de la contamination, et donc les possibles dommages, est étroitement liée aux espèces fongiques impliquées. Nous avons calculé la moyenne de la contamination fongique par chaque établissement avant le lavage et la désinfection afin d'établir les niveaux de Fréquence et, par rapport à l'Exposition, ont été crées pour regrouper les intervalles d'heures hebdomadaires consacrées à l'activité professionnelle en question. Sur les 124 travailleurs qui ont participé à l'étude, 58 (46,8%) avaient des lésions visibles. Parmi ces 58, les Levures ont été les plus isolées (41,4%), suivis par des Dermatophytes (24,1%) et des Filamenteux Non Dermatophytes (6,9%). Candida parapsilosis and Rhodotorula sp. ont été les Levures les plus fréquemment isolées (20,2%); dans le cas des Dermatophytes, Trichophyton rubrum est le plus fréquent (55,5%) et pour les Filamenteux Non Dermatophytes, Penicillium sp. a été le plus isolé (15,6%), suivi par Fusarium sp. (12,5%). En ce qui concerne la contamination fongique des surfaces, 37 champignons filamenteux ont été isolés. Le genre Fusarium est le plus fréquent avant et après le lavage et la désinfection (19,1% - 17,2%). Pour la levure, 12 levures différentes ont été identifiées, ayant été Cryptococcus sp. (40,6%) et Candida sp. (49,3%) les plus fréquents avant et après le lavage et la désinfection, respectivement. En ce qui concerne la contamination fongique de l'air, on a identifié 25 différents champignons filamenteux, où les 3 genres les plus fréquemment isolés étaient Cladosporium (36,6%), Penicillium (19,0%) et Aspergillus (10,2%). Pour les levures, il a été identifié le genre xxx Rhodotorula (87,5%) et les espèces Trichosporon mucoides et Cryptococcus unigutulattus (12,5%). On a vérifié une association, au niveau de signification de 5%, entre les lésions visibles et les heures hebdomadaires et entre les lésions visibles et la durée d’occupation, ce qui confirme l'influence de la durée de l'exposition aux facteurs de risque (contamination fongique dans le milieu de travail) pour la présence des lésions visibles chez les travailleurs exposés (Tinea pedis et onychomycose), en démontrant une relation entre l'exposition au facteur de risque dans ces études - l'exposition professionnelle aux champignons - avec les effets sur la santé. Les variables environnementales évalué (température, humidité relative et la vitesse de l'air) ne modifient pas la contamination fongique de l'air et des surfaces; donc, n'a pas été démontré aucune relation statistiquement significative (p>0,05). Cependant, il y a une influence du nombre d'occupants qui ont participé à chacun des établissements en moyenne des unités formant colonie par mètre carré sur la surface avant le lavage et la désinfection. Il n'y avait pas de corrélation entre les résultats quantitatifs de la contamination fongique de l'air et des surfaces des 10 établissements surveillés, cependant il existe des différences importantes, au niveau de signification de 10% entre la contamination fongique des surfaces et de la contamination fongique de l'air (p <0,1), on a constaté que malgré 50% des niveaux les plus bas étaient plus élevés dans la contamination fongique de l'air, la contamination fongique des surfaces présentée une plus grande variabilité quantitativement. En ce qui concerne les différences de la contamination fongique des surfaces dans les 10 établissements entre avant et après le lavage et la désinfection, il y avait seulement une réduction significative (p<0,05) de la contamination fongique après le lavage et la désinfection dans les balnéaires et vestiaires pour les hommes par rapport aux levures. Lors de l'établissement choisi, on a constaté que le rapport entre la contamination fongique et la température et l'humidité relative n'était pas significatif (p>0,05) dans les deux saisons et aussi on n’a pas observé l'influence des occupants en moyenne des unités formant colonie par mètres carrés de surfaces avant le lavage et la désinfection dans les deux saisons de l'année. Dans presque toutes les situations ou on a vérifié des différences significatives entre les deux saisons, il ya eu une augmentation des unités formant des colonies par mètre carré en Hiver, à l'exception du total des unités formant des colonies par mètre carré avant le lavage et désinfection dans les balnéaires et vestiaires des hommes où il y a eu une augmentation en Été. On a également été constaté que seulement a eu une réduction de la contamination des xxxi champignons après la désinfection de l'escalier d'accès en Hiver et dans les balnéaires et vestiaires des hommes en Été. Avec la méthode pour établir standard d’exposition professionnelle au fungi sur les surfaces on a obtenu dans les 10 établissements, avec le Niveau de Risque Faible de 65 places (54,2%), avec le Niveau de Risque Moyen 23 places (19,2%) et 32 places avec le Niveau de Risque Élevé (26,6%). Près du jacuzzi et près de la piscine sont les lieux avec des plus évaluations de Niveau de Risque Élevé. Lors de l'établissement choisi, il a été constaté que, dans l'Été, après le lavage et la désinfection, un plus grand nombre de places évaluées comme présentant un Niveau de Risque Élevé et en Hiver on a constaté la situation inverse avec de nombreux points de Niveau de Risque Élevé avant le lavage et la désinfection. A côté de la piscine et les escaliers ont été les lieux avec plus grands classifications de Niveau de Risque Élevé en Été et en Hiver. On a isolé, chez les travailleurs, des champignons communs aux isolés sur les surfaces. Avant le lavage et la désinfection, 30,3% des champignons ont été isolés sur les travailleurs et sur les surfaces et, après ces procédures, 45,5% des champignons ont été isolés fréquemment. Les levures les plus souvent isolées et les plus fréquentes avant et après le lavage et la désinfection des surfaces, et aussi dans les résultats d'échantillons biologiques prélevés sur les travailleurs, étaient du genre Rhodotorula et les espèces de Candida parapsilosis, ce qui permet confirmer que l'infection fongique des travailleurs est liée à la contamination fongique des surfaces. On a conclu qu’il est nécessaire l'intervention en Santé Occupationnelle sous la surveillance de l'environnement et sous la surveillance de la santé, afin de réduire la prévalence des infections fongiques. Pour atteindre cet objectif, nous suggérons la mise en oeuvre de mesures préventives, y compris: le contrôle de la contamination fongique des surfaces par des méthodes de lavage et de désinfection afin de minimiser la contamination fongique des surfaces, l'identification précoce de l'infection avec des prélèvements biologiques périodiques, notamment un protocole pour la surveillance de la santé, et aussi la conscience du sens de l'hygiène personnelle et le traitement des pathologies. La méthode mise en place pour l’établissement d’un standard d’exposition professionnelle au fungi sur les surfaces, servira à estimer non seulement le risque d'infection fongique des travailleurs dans les gymnases avec des piscines, mais aussi pour faciliter l'établissement de valeurs de référence de champignons, l'application des mesures correctives immédiates et appropriées, et aussi la prévention des infections fongiques, non seulement dans les gymnases avec piscine, mais aussi dans d'autres contextes professionnels.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Portugal continental apresenta uma vasta área florestal, que representa cerca de 35,4% da ocupação total do solo, com predominância de espécies como o eucalipto (Eucalyptus globulus) e o pinheiro-bravo (Pinus pinaster). Estas espécies apresentam uma elevada importância a nível económico, designadamente devido à sua ampla utilização, nomeadamente na indústria de celulose e papel, gerando elevadas quantidades de resíduos. Este resíduo de biomassa florestal é utilizado, na sua totalidade, para a geração de energia, na forma de eletricidade ou aquecimento. No entanto, existem outras opções viáveis, a nível económico, tais como a valorização destes subprodutos como fonte de compostos polifenólicos tornando-os, assim, um produto de valor acrescentado. A extração de compostos fenólicos de subprodutos florestais, como folhas de eucalipto e agulhas de pinheiros tem vindo a aumentar devido, principalmente, à substituição de antioxidantes sintéticos, contribuindo para a valorização de subprodutos florestais. Contudo, apesar de todas as potenciais aplicações e vantagens, apenas algumas centenas de espécies aromáticas identificadas são utilizadas à escala comercial. Neste trabalho foi avaliada a capacidade antioxidante de subprodutos da floresta, otimizando as condições de extração através do estudo dos fatores: tempo de extração, temperatura e composição de solvente através do método de superfície de resposta. O planeamento experimental utilizado teve como base um planeamento de compósito central e a avaliação do perfil de antioxidantes das matrizes analisadas foi realizada através de métodos de quantificação total, como o teor fenólico total, a atividade anti-radicalar – método do DPPH (radical 2,2-difenil-1-picrilhidrazilo) e o método de FRAP. Estes métodos analíticos convencionais foram modificados e, devidamente validados, para a análise em leitor de microplacas. Verificou-se que os extratos de pinheiro e de eucalipto, tanto as amostras verdes com as amostras, apresentam uma promissora capacidade antioxidante. O planeamento fatorial aplicado permitiu otimizar as condições de extração em relação às matrizes verdes. Contudo, o mesmo não se verificou em relação às matrizes secas. A composição (% de água) é sem dúvida o fator com mais efeito em todas as amostras (coeficientes de primeira e segunda ordem no modelo). Também a temperatura foi identificada como um fator com efeito significativo sobre os sistemas em análise.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O tratamento das águas residuais domésticas surge com o intuito de degradar os poluentes presentes, para que as águas residuais tratadas não prejudiquem o ambiente nem a saúde pública. O presente trabalho teve como objetivo a conceção e o dimensionamento de uma Estação de Tratamento de Águas Residuais (ETAR) na freguesia de Canelas com a finalidade de substituir a já existente e permitir a ampliação da área da rede de saneamento da freguesia. Foram considerados dois tipos de ETAR’s, compacta e convencional, para tratar águas residuais domésticas de aproxidamente 2000 habitantes, com um caudal médio de 400 m3/dia e um caudal de ponta de 1136,7 m3/dia. Das duas opções optou-se pela convencional uma vez que acarreta um menor investimento, no valor de 187 232 €, e se considera também mais adequada às características do efluente a tratar. O tratamento escolhido inclui inicialmente uma gradagem, com uma grade constituída por sete barras com um espaçamento de 20 mm entre elas, seguida de um tamisador rotativo com uma abertura de malha de 3 mm. Depois do tamisador, optou-se por um sistema de desarenação/desengorduramento com um volume do tanque de 3,95 m3 e um fluxo de ar de 17,9 m3/h. Na fase seguinte considerou-se um tratamento biológico por lamas ativadas em regime de arejamento prolongado num tanque de arejamento de volume igual a 245,8 m3 com um arejador submerso, seguindo-se um decantador secundário de volume 33,3 m3. Por último, escolheu-se um sistema de desinfeção por ultravioleta e, a montante do mesmo, um filtro rápido para eliminar pequenas partículas que o efluente ainda possa conter. Para a desinfeção foram consideradas duas secções com cinco módulos de duas lâmpadas cada, ou seja, vinte lâmpadas ultravioleta. Dos resíduos produzidos pelo tratamento da água residual, os gradados e as areias serão encaminhados para aterro, enquanto que as lamas serão enviadas para a ETAR das Termas de S.Vicente, para que sofram o tratamento adequado e sejam encaminhadas para o destinal final adequado (aplicação em solos agrícolas, compostagem ou em alternativa para aterro). No caso da ETAR covencional foi ainda avaliada a possível reutilização de um decantador da ETAR de Milhundos uma vez que esta se encontrava em fase de desativação. Desta avaliação, concluiu-se que não seria economicamente viável o seu reaproveitamento. Mestrado em Engenharia Química – Tecnologias de Proteção Ambiental Para além disso realizou-se também um levantamento dos principais problemas que ocorrem na maioria das ETAR’s e foram apresentadas as respetivas sugestões de resolução. A realização de um inquérito permititu concluir que os odores são o problema que mais causa incómodo à população.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A atividade humana e industrial usa a água para as suas atividades do quotidiano. A água é um recurso natural escasso cuja qualidade deve ser protegida, defendida, gerida e tratada em conformidade com o seu uso. Nesse âmbito, a gestão das águas prossegue objetivos de proteção da saúde humana e de preservação, proteção e melhoria da qualidade do ambiente[1]. Desde o final do seculo XIX até aos dias de hoje, verificou-se uma forte evolução nos sistemas de tratamento de águas residuais. Esta evolução foi fundamental para dar resposta às maiores exigências de qualidade do efluente tratado. O sistema de lamas ativadas é um dos processos de tratamento biológico das águas residuais mais usados em todo o mundo. Este trabalho consiste no desenvolvimento do projeto de conceção e dimensionamento de uma Estação de Tratamento de Águas Residuais (ETAR) para servir um pequeno aglomerado de cerca de 3200 habitantes equivalentes (hab.eq.), tendo como objetivo o dimensionamento de todas as etapas de tratamento necessárias ao cumprimento da legislação em vigor para a descarga das águas residuais urbanas no meio recetor. O Decreto-lei nº 152/97[2], relativo ao tratamento de águas residuais urbanas, juntamente com o Decreto-lei nº 149/2004[3] que identifica as zonas sensíveis e de zonas menos sensíveis, permitem que as entidades licenciadoras definam o grau de tratamento que a instalação deve possuir tendo em consideração a classificação do meio onde o efluente tratado é descarregado. O Decreto-Lei n.º 135/2009[1] estabelece o regime de identificação, gestão, monitorização e classificação da qualidade das águas balneares, impondo a qualidade microbiológica da água residual tratada mediante o meio recetor, e portanto conseguindo-se assim definir o tratamento de desinfeção a adotar. Resumidamente, a conceção do tratamento focou as seguintes etapas: tratamento preliminar formado por uma unidade compacta de tamisação, desarenador e desengordurador, tratamento secundário por lamas ativadas em regime de arejamento prolongado constituído por dois reatores com cerca de 400 m3 de volume seguido de um decantador com um diâmetro de 9.5 m, tratamento terciário de desinfeção composto por uma microtamisação seguido de desinfeção UV, e a utilização das operações comuns de espessamento e desidratação das lamas produzidas em excesso pelo tratamento, constituída por com um espessador gravítico com 4.6 m de diâmetro, e um filtro banda para a desidratação.