936 resultados para Diffractive dissociation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Endurance-trained athletes experience a low level of postprandial lipaemia, but this rapidly increases with detraining. We sought to determine whether detraining-induced changes to postprandial metabolism influenced endothelial function and inflammation. Eight endurance-trained men each undertook two oral fat tolerance tests [blood taken fasted and for 6 h following a high-fat test meal (80 g fat, 80 g carbohydrate)]: one during a period of their normal training (trained) and one after 1 wk of no exercise (detrained). Endothelial function in the cutaneous microcirculation was assessed using laser Doppler imaging with iontophoresis in the fasted state and 4 h postprandially during each test. Fasting plasma triglyceride (TG) concentrations increased by 35% with detraining (P = 0.002), as did postprandial plasma (by 53%, P = 0.002), chylomicron (by 68%, P = 0.02) and very low-density lipoprotein (by 51%, P = 0.005) TG concentrations. Endothelial function decreased postprandially in both the trained (by 17%, P = 0.03) and detrained (by 22%, P = 0.03) conditions but did not differ significantly between the trained and detrained conditions in either the fasted or the postprandial states. These results suggest that, although fat ingestion induces endothelial dysfunction, interventions that alter postprandial TG metabolism will not necessarily concomitantly influence endothelial function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fabrication of submicron-height sine-like relief of a trifocal diffractive zone plate using a nanoimprinting technique is studied. The zone plate is intended for use in combined trifocal diffractive-refractive lenses and provides the possibility to form trifocal intraocular lenses with predetermined light intensity distribution between foci. The optical properties of the designed zone plate having the optical powers 3 D, 0, -3D in the three main diffraction orders are theoretically and experimentally investigated. The results of the theoretical investigations are in good agreement with experimental measurements. The effects of the pupil size (lens diameter) as well as the wavelength-dependent behavior of the zone plate are also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous research (e.g., Jüttner et al, 2013, Developmental Psychology, 49, 161-176) has shown that object recognition may develop well into late childhood and adolescence. The present study extends that research and reveals novel di erences in holistic and analytic recognition performance in 7-11 year olds compared to that seen in adults. We interpret our data within Hummel’s hybrid model of object recognition (Hummel, 2001, Visual Cognition, 8, 489-517) that proposes two parallel routes for recognition (analytic vs. holistic) modulated by attention. Using a repetition-priming paradigm, we found in Experiment 1 that children showed no holistic priming, but only analytic priming. Given that holistic priming might be thought to be more ‘primitive’, we confirmed in Experiment 2 that our surprising finding was not because children’s analytic recognition was merely a result of name repetition. Our results suggest a developmental primacy of analytic object recognition. By contrast, holistic object recognition skills appear to emerge with a much more protracted trajectory extending into late adolescence

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Holistic face perception, i.e. the mandatory integration of featural information across the face, hasbeen considered to play a key role when recognizing emotional face expressions (e.g., Tanaka et al.,2002). However, despite their early onset holistic processing skills continue to improvethroughout adolescence (e.g., Schwarzer et al., 2010) and therefore might modulate theevaluation of facial expressions. We tested this hypothesis using an attentional blink (AB)paradigm to compare the impact of happy, fearful and neutral faces in adolescents (10–13 years)and adults on subsequently presented neutral target stimuli (animals, plants and objects) in a rapidserial visual presentation stream. Adolescents and adults were found to be equally reliable whenreporting the emotional expression of the face stimuli. However, the detection of emotional butnot neutral faces imposed a significantly stronger AB effect on the detection of the neutral targetsin adults compared to adolescents. In a control experiment we confirmed that adolescents ratedemotional faces lower in terms of valence and arousal than adults. The results suggest a protracteddevelopment of the ability to evaluate facial expressions that might be attributed to the latematuration of holistic processing skills.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neutron-rich light nuclei and their reactions play an important role in the creation of chemical elements. Here, data from a Coulomb dissociation experiment on N-20,N-21 are reported. Relativistic N-20,N-21 ions impinged on a lead target and the Coulomb dissociation cross section was determined in a kinematically complete experiment. Using the detailed balance theorem, the N-19(n,gamma)N-20 and N-20(n,gamma)N-21 excitation functions and thermonuclear reaction rates have been determined. The N-19(n,gamma)N-20 rate is up to a factor of 5 higher at T < 1 GK with respect to previous theoretical calculations, leading to a 10% decrease in the predicted fluorine abundance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L’étude des polymorphismes et des aspects multifactoriels des déterminants de la santé suscite un engouement majeur envers la recherche populationnelle en génétique et génomique. Cette méthode de recherche requiert cependant la collecte et l’analyse d’un nombre élevé d’échantillons biologiques et de données associées, ce qui stimule le développement des biobanques. Ces biobanques, composées des données personnelles et de santé de milliers de participants, constituent désormais une ressource essentielle permettant l’étude de l’étiologie des maladies complexes et multifactorielles, tout en augmentant la rapidité et la fiabilité des résultats de recherche. Afin d’optimiser l’utilisation de ces ressources, les chercheurs combinent maintenant les informations contenues dans différentes biobanques de manière à créer virtuellement des mégacohortes de sujets. Cependant, tout partage de données à des fins de recherche internationale est dépendant de la possibilité, à la fois légale et éthique, d’utiliser ces données aux fins pressenties. Le droit d’utiliser les données personnelles, médicales et génétiques de participants dans le cadre de recherches internationales est soumis à un ensemble complexe et exhaustif d’exigences légales et éthiques. Cette complexité est exacerbée lorsque les participants sont décédés. Fondée sur une révision de l’interprétation individualiste du concept de consentement éclairé, ainsi qu’une perspective constructiviste des concepts de confiance et d’autonomie, cette thèse se situe au carrefour de la recherche, du droit et de l’éthique, et a pour objectif de proposer un modèle promouvant l’harmonisation éthique et juridique des données aux fins de recherches internationales en génétique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The photochemistry of the polar regions of Earth, as well as the interstellar medium, is driven by the effect of ultraviolet radiation on ice surfaces and on the materials trapped within them. While the area of ice photochemistry is vast and much research has been completed, it has only recently been possible to study the dynamics of these processes on a microscopic level. One of the leading techniques for studying photoreaction dynamics is Velocity Map Imaging (VMI). This technique has been used extensively to study several types of reaction dynamics processes. Although the majority of these studies have utilized molecular beams as the main medium for reactants, new studies showed the versatility of the technique when applied to molecular dynamics of molecules adsorbed on metal surfaces. Herein the development of a velocity map imaging apparatus capable of studying the photochemistry of condensed phase materials is described. The apparatus is used to study of the photo-reactivity of NO2 condensed within argon matrices to illustrate its capabilities. A doped ice surface is formed by condensing Ar and NO2 gas onto a sapphire rod which is cooled using a helium compressor to 20 K. The matrix is irradiated using an Nd:YAG laser at 355 nm, and the resulting NO fragment is state-selectively ionized using an excimer-pumped dye laser. In all, we are able to detect transient photochemically generated species and can collect information on their quantum state and kinetic energy distribution. It is found that the REMPI spectra changes as different sections of the dissociating cloud are probed. The rotational and translational energy populations are found to be bimodal with a low temperature component roughly at the temperature of the matrix, and a second component with much higher temperature, the rotational temperature showing a possible population inversion, and the translational temperature of 100-200 K. The low temperature translational component is found to dominate at long delay times between dissociation and ionization, while at short time delays the high temperature component plays a larger role. The velocity map imaging technique allows for the detection of both the axial and radial components of the translational energy. The distribution of excess energy over the rotational, electronic and translational states of the NO photofragments provides evidence for collisional quenching of the fragments in the Ar-matrix prior to their desorption.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: Elevated shame and dissociation are common in dissociative identity disorder (DID) and chronic posttraumatic stress disorder (PTSD) and are part of the constellation of symptoms defined as complex PTSD. Previous work examined the relationship between shame, dissociation, and complex PTSD and whether they are associated with intimate relationship anxiety, relationship depression, and fear of relationships. This study investigated these variables in traumatized clinical samples and a nonclinical community group.

Method: Participants were drawn from the DID (n = 20), conflict-related chronic PTSD (n = 65), and nonclinical (n = 125) populations and completed questionnaires assessing the variables of interest. A model examining the direct impact of shame and dissociation on relationship functioning, and their indirect effect via complex PTSD symptoms, was tested through path analysis.

Results: The DID sample reported significantly higher dissociation, shame, complex PTSD symptom severity, relationship anxiety, relationship depression, and fear of relationships than the other two samples. Support was found for the proposed model, with shame directly affecting relationship anxiety and fear of relationships, and pathological dissociation directly affecting relationship anxiety and relationship depression. The indirect effect of shame and dissociation via complex PTSD symptom severity was evident on all relationship variables.

Conclusion: Shame and pathological dissociation are important for not only the effect they have on the development of other complex PTSD symptoms, but also their direct and indirect effects on distress associated with relationships.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To quantitatively evaluate visual function 12 months after bilateral implantation of the Physiol FineVision® trifocal intraocular lens (IOL) and to compare these results with those obtained in the first postoperative month. METHODS: In this prospective case series, 20 eyes of 10 consecutive patients were included. Monocular and binocular, uncorrected and corrected visual acuities (distance, near, and intermediate) were measured. Metrovision® was used to test contrast sensitivity under static and dynamic conditions, both in photopic and low-mesopic settings. The same software was used for pupillometry and glare evaluation. Motion, achromatic, and chromatic contrast discrimination were tested using 2 innovative psychophysical tests. A complete ophthalmologic examination was performed preoperatively and at 1, 3, 6, and 12 months postoperatively. Psychophysical tests were performed 1 month after surgery and repeated 12 months postoperatively. RESULTS: Final distance uncorrected visual acuity (VA) was 0.00 ± 0.08 and distance corrected VA was 0.00 ± 0.05 logMAR. Distance corrected near VA was 0.00 ± 0.09 and distance corrected intermediate VA was 0.00 ± 0.06 logMAR. Glare testing, pupillometry, contrast sensitivity, motion, and chromatic and achromatic contrast discrimination did not differ significantly between the first and last visit (p>0.05) or when compared to an age-matched control group (p>0.05). CONCLUSIONS: The Physiol FineVision® trifocal IOL provided satisfactory full range of vision and quality of vision parameters 12 months after surgery. Visual acuity and psychophysical tests did not vary significantly between the first and last visit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To quantitatively evaluate visual function 12 months after bilateral implantation of the Physiol FineVision® trifocal intraocular lens (IOL) and to compare these results with those obtained in the first postoperative month. METHODS: In this prospective case series, 20 eyes of 10 consecutive patients were included. Monocular and binocular, uncorrected and corrected visual acuities (distance, near, and intermediate) were measured. Metrovision® was used to test contrast sensitivity under static and dynamic conditions, both in photopic and low-mesopic settings. The same software was used for pupillometry and glare evaluation. Motion, achromatic, and chromatic contrast discrimination were tested using 2 innovative psychophysical tests. A complete ophthalmologic examination was performed preoperatively and at 1, 3, 6, and 12 months postoperatively. Psychophysical tests were performed 1 month after surgery and repeated 12 months postoperatively. RESULTS: Final distance uncorrected visual acuity (VA) was 0.00 ± 0.08 and distance corrected VA was 0.00 ± 0.05 logMAR. Distance corrected near VA was 0.00 ± 0.09 and distance corrected intermediate VA was 0.00 ± 0.06 logMAR. Glare testing, pupillometry, contrast sensitivity, motion, and chromatic and achromatic contrast discrimination did not differ significantly between the first and last visit (p>0.05) or when compared to an age-matched control group (p>0.05). CONCLUSIONS: The Physiol FineVision® trifocal IOL provided satisfactory full range of vision and quality of vision parameters 12 months after surgery. Visual acuity and psychophysical tests did not vary significantly between the first and last visit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L’étude des polymorphismes et des aspects multifactoriels des déterminants de la santé suscite un engouement majeur envers la recherche populationnelle en génétique et génomique. Cette méthode de recherche requiert cependant la collecte et l’analyse d’un nombre élevé d’échantillons biologiques et de données associées, ce qui stimule le développement des biobanques. Ces biobanques, composées des données personnelles et de santé de milliers de participants, constituent désormais une ressource essentielle permettant l’étude de l’étiologie des maladies complexes et multifactorielles, tout en augmentant la rapidité et la fiabilité des résultats de recherche. Afin d’optimiser l’utilisation de ces ressources, les chercheurs combinent maintenant les informations contenues dans différentes biobanques de manière à créer virtuellement des mégacohortes de sujets. Cependant, tout partage de données à des fins de recherche internationale est dépendant de la possibilité, à la fois légale et éthique, d’utiliser ces données aux fins pressenties. Le droit d’utiliser les données personnelles, médicales et génétiques de participants dans le cadre de recherches internationales est soumis à un ensemble complexe et exhaustif d’exigences légales et éthiques. Cette complexité est exacerbée lorsque les participants sont décédés. Fondée sur une révision de l’interprétation individualiste du concept de consentement éclairé, ainsi qu’une perspective constructiviste des concepts de confiance et d’autonomie, cette thèse se situe au carrefour de la recherche, du droit et de l’éthique, et a pour objectif de proposer un modèle promouvant l’harmonisation éthique et juridique des données aux fins de recherches internationales en génétique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Personal electronic devices, such as cell phones and tablets, continue to decrease in size while the number of features and add-ons keep increasing. One particular feature of great interest is an integrated projector system. Laser pico-projectors have been considered, but the technology has not been developed enough to warrant integration. With new advancements in diode technology and MEMS devices, laser-based projection is currently being advanced for pico-projectors. A primary problem encountered when using a pico-projector is coherent interference known as speckle. Laser speckle can lead to eye irritation and headaches after prolonged viewing. Diffractive optical elements known as diffusers have been examined as a means to lower speckle contrast. Diffusers are often rotated to achieve temporal averaging of the spatial phase pattern provided by diffuser surface. While diffusers are unable to completely eliminate speckle, they can be utilized to decrease the resultant contrast to provide a more visually acceptable image. This dissertation measures the reduction in speckle contrast achievable through the use of diffractive diffusers. A theoretical Fourier optics model is used to provide the diffuser’s stationary and in-motion performance in terms of the resultant contrast level. Contrast measurements of two diffractive diffusers are calculated theoretically and compared with experimental results. In addition, a novel binary diffuser design based on Hadamard matrices will be presented. Using two static in-line Hadamard diffusers eliminates the need for rotation or vibration of the diffuser for temporal averaging. Two Hadamard diffusers were fabricated and contrast values were subsequently measured, showing good agreement with theory and simulated values. Monochromatic speckle contrast values of 0.40 were achieved using the Hadamard diffusers. Finally, color laser projection devices require the use of red, green, and blue laser sources; therefore, using a monochromatic diffractive diffuser may not optimal for color speckle contrast reduction. A simulation of the Hadamard diffusers is conducted to determine the optimum spacing between the two diffusers for polychromatic speckle reduction. Experimental measured results are presented using the optimal spacing of Hadamard diffusers for RGB color speckle reduction, showing 60% reduction in contrast.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background In recent years new models of intraocular lenses are appearing on the market to reduce requirements for additional optical correction. The purpose of this study is to assess visual outcomes following bilateral cataract surgery and the implant of a FineVision® trifocal intraocular lens (IOL). Methods Prospective, nonrandomized, observational study. Vision was assessed in 44 eyes of 22 patients (mean age 68.4 ± 5.5 years) before and 3 months after surgery. Aberrations were determined using the Topcon KR-1 W wave-front analyzer. LogMAR visual acuity was measured at distance (corrected distance visual acuity, CDVA 4 m), intermediate (distance corrected intermediate visual acuity, DCIVA 60 cm) and near (distance corrected near visual acuity, DCNVA 40 cm). The Pelli-Robson letter chart and the CSV-1000 test were used to estimate contrast sensitivity (CS). Defocus curve testing was performed in photopic and mesopic conditions. Adverse photic phenomena were assessed using the Halo v1.0 program. Results Mean aberration values for a mesopic pupil diameter were: total HOA RMS: 0.41 ± 0.30 μm, coma: 0.32 ± 0.22 μm and spherical aberration: 0.21 ± 0.20 μm. Binocular logMAR measurements were: CDVA −0.05 ± 0.05, DCIVA 0.15 ± 0.10, and DCNVA 0.06 ± 0.10. Mean Pelli-Robson CS was 1.40 ± 0.14 log units. Mean CSV100 CS for the 4 frequencies examined (A: 3 cycles/degree (cpd), B: 6 cpd, C: 12 cpd, D: 18 cpd) were 1.64 ± 0.14, 1.77 ± 0.18, 1.44 ± 0.24 and 0.98 ± 0.24 log units, respectively. Significant differences were observed in defocus curves for photopic and mesopic conditions (p < 0.0001). A mean disturbance index of 0.28 ± 0.22 was obtained. Conclusions Bilateral FineVision IOL implant achieved a full range of adequate vision, satisfactory contrast sensitivity, and a lack of significant adverse photic phenomena. Trial registration Eudract Clinical Trials Registry Number: 2014-003266-2.