978 resultados para Chromatographic columns


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A GC method to determine caprolactam in water, 15 ethanol, and olive oil food simulants was developed and validated. Linear ranges varied from 0.96 to 642.82 g/mL for water, 0.64 to 800.32 g/mL for 15 ethanol, and 1.06 to 1062.34 g/g for olive oil, with correlation coefficients higher than 0.999. Method precision studies showed RSD values lower than 5.45, while method accuracy studies showed recovery from 72 to 111 for all simulants. The effect of gamma irradiation on caprolactam migration from multilayer polyamide 6 (PA-6) films intended for cheese into water, 15 ethanol, olive oil, and 3 acetic acid simulants was also studied. For migration assay, non-irradiated and irradiated (12 kGy) films were placed in contact with the simulant and exposed at 40C for 10 days. The validated method was used to quantify caprolactam migration from multilayer PA-6 films into the simulants, which ranged from 1.03 to 7.59 mg/kg for non-irradiated films, and from 4.82 to 11.32 mg/kg for irradiated films. Irradiation caused almost no changes in caprolactam levels, with the exception of olive oil, which showed an increase in the caprolactam level. All multilayer PA-6 films were in accordance with the requirements of the legislation for caprolactam migration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and sensitive analytical method for simultaneous determination of anastrozole, bicalutamide, and tamoxifen as well as their synthetic impurities, anastrozole pentamethyl, bicalutamide 3-fluoro-isomer, and tamoxifen e-isomer, was developed and validated by using high performance liquid chromatography (HPLC). The separation was achieved on a Symmetry (R) C-8 column (100 x 4.6 mm i.d., 3.5 mu m) at room temperature (+/- 24 degrees C), with a mobile phase consisting of acetonitrile/water containing 0.18% N,N dimethyloctylamine and pH adjusted to 3.0 with orthophosphoric acid (46.5/53.5, v/v) at a flow rate of 1.0 mL min(-1) within 20 min. The detection was made at a wavelength of 270 nm by using ultraviolet (UV) detector. No interference peaks from excipients and relative retention time indicated the specificity of the method. The calibration curve showed correlation coefficients (r) > 0.99 calculated by linear regression and analysis of variance (ANOVA). The limit of detection (LOD) and limit of quantitation (LOQ), respectively, were 2.2 and 6.7 mu g mL(-1) for anastrozole, 2.61 and 8.72 mu g mL(-1) for bicalutamide, 2.0 and 6.7 mu g mL(-1) for tamoxifen, 0.06 and 0.22 mu g mL(-1) for anastrozole pentamethyl, 0.02 and 0.07 mu g mL(-1) for bicalutamide 3-fluoro-isomer, and 0.002 and 0.007 mu g mL(-1) for tamoxifen e-isomer. Intraday and interday relative standard deviations (RSDs) were <2.0% (drugs) and <10% (degradation products) as well as the comparison between two different analysts, which were calculated by f test. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method using Liquid Phase Microextraction for simultaneous detection of citalopram (CIT), paroxetine (PAR) and fluoxetine (FLU), using venlafaxine as internal standard, in plasma by high performance liquid chromatography with fluorescence detection was developed. The linearity was evaluated between 5.0 and 500 ng mL(-1) (r > 0.99) and the limit of quantification was 2.0, 3.0 and 5.0 ng mL-1 for CIT. PAR and FLU, respectively. Therefore, it can be applied to therapeutic drug monitoring, pharmacokinetics or bioavailability studies and its advantages are that it necessary relatively inexpensive equipment and sample preparation techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundacao de Amparo a Pesquisa do Estado de Sao Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experimental study on Vortex-Induced Motion (VIM) of the semi-submersible platform concept with four square columns is presented. Model tests were carried out to check the influence of different headings and hull appendages (riser supports located at the pontoons; fairleads and the mooring stretches located vertically at the external column faces; and hard pipes located vertically at the internal column faces). The results comprise in-line, transverse and yaw motions, as well as combined motions in the XY plane, drag and lift forces and spectral analysis. The main results showed that VIM in the transverse direction occurred in a range of reduced velocity 4.0 up to 14.0 with amplitude peaks around reduced velocities around 7.0 and 8.0. The largest transverse amplitudes obtained were around 40% of the column width for 30 degrees and 45 degrees incidences. Another important result observed was a considerable yaw motion oscillation, in which a synchronization region could be identified as a resonance phenomenon. The largest yaw motions were verified for the 0 degrees incidence and the maxima amplitudes around 4.5 degrees. The hull appendages located at columns had the greatest influence on the VIM response of the semi-submersible. (C) 2012 Elsevier Ltd. All rights reserved.