942 resultados para Bubble-column


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Photopolymerized sol-gel monolithic columns for use in capillary electrochromatography were prepared in 125 mu m i.d. polyacrylate-coated fused-silica capillaries. The polyacrylate-coating, unlike the polyimide one, is transparent to the radiation used (approximate to 370 nm), and thus, no coating removal is necessary. This is a very important particularity since intrinsic capillary column characteristics, such as flexibility and mechanical resistance, are unchanged. A mixture containing metacryloxypropyltrimethoxysilane (MPTMS) as the polymeric precursor, hydrochloric acid as the catalyst, toluene as the porogen and bis(2,4,6-trimethylbenzoyl)-phenylphosphine oxide (Irgacure 819) as the photoinitiator was irradiated at 370 nm for 20 min inside the capillaries to prepare the columns through sol-gel approach. The versatility and viability of the use of polyacrilate as a new capillary external coating were shown through preparation of two columns under different conditions, which were tested in electrochromatography for separation of standard mixture containing thiourea (marker compound), propylbenzene, phenanthrene and pyrene. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo desta investigação foi observar a distribuição vertical da comunidade do zooplâncton no Lago Amapá (10º2'36S e 67º50'24W), localizado na planície de inundação do Rio Acre. Amostragens foram conduzidas em três diferentes profundidades da coluna da água, considerando aspectos sazonais do zooplâncton, parâmetros físicos, químicos e biológicos. Coletas foram realizadas semanalmente com Garrafa de Van Dorn. As espécies apresentaram maiores concentrações no meio da coluna da água. Foram encontradas 38 espécies, assim distribuídas: Rotifera (30), Cladocera (5) e Cyclopoida (3). A temperatura da coluna da água em geral apresentou-se alta, em torno de 30ºC, com pequena variação, resultando em baixa viscosidade. O índice de Jaccard, comparando-se as três estações de coletas, demonstrou que durante a fase de águas baixas, as estações 1 e 3 foram as mais similares (Cj = 0.7058), especialmente no meio da coluna da água. Lago Amapá apresentou características em conformidade com o Modelo do Distúrbio Intermediário, favorecendo a colonização de grupos oportunistas, tais como rotíferos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two-photon correlation of the light pulse emitted from a sonoluminescence bubble is discussed. It is shown that several important features of the mechanism of light emission, such as the time scale and the shape of the emission region, could be obtained from Hanbury-Brown-Twiss interferometry. We also argue that such a measurement may serve to reject one of the two currently suggested emission mechanisms, i.e., the thermal process versus the dynamical Casimir effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and rapid procedure for extraction and separation from aldrin, DDT, endrin, heptachloro- and methoxychloro-organochlorine pesticides in raw milk has been developed by direct injection into an HPLC system without pretreatment of the samples, using an ISRP column.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method has been developed for extraction and determination of carbofuran in milk. The method involved direct injection of raw milk on to a human serum albumin dimethyloctyl-silica gel (HSA-Cs) column and the use of 80:20 (v/v) 0.01 M phosphate buffer pH 5.5 - acetonitrile as mobile phase. UV spectrophotometric detection was performed at 220 nm. Identification was based on retention time. Quantification was performed by automatic peak-area determination and was calibrated by use of an external standard.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Factorial experiments are widely used in industry to investigate the effects of process factors on quality response variables. Many food processes, for example, are not only subject to variation between days, but also between different times of the day. Removing this variation using blocking factors leads to row-column designs. In this paper, an algorithm is described for constructing factorial row-column designs when the factors are quantitative, and the data are to be analysed by fitting a polynomial model. The row-column designs are constructed using an iterative interchange search, where interchanges that result in an improvement in the weighted mean of the efficiency factors corresponding to the parameters of interest are accepted. Some examples illustrating the performance of the algorithm are given.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Oxycellulose (OXICEL) was packed in a glass column to pre-concentrate metal cations from aqueous solutions. The pre-concentrated metal cations are directly eluted from the column using 5.0 mL of 1.0 mol L(-1) hydrochloric acid. The optimum pre-concentration conditions are given and the retention efficency achieved is higher than 95%. The enrichment factor is 10 for sample volumes of 50 mL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Capacitated p-median problem (CPMP) seeks to solve the optimal location of p facilities, considering distances and capacities for the service to be given by each median. In this paper we present a column generation approach to CPMP. The identified restricted master problem optimizes the covering of 1-median clusters satisfying the capacity constraints, and new columns are generated considering knapsack subproblems. The Lagrangean/surrogate relaxation has been used recently to accelerate subgradient like methods. In this work the Lagrangean/surrogate relaxation is directly identified from the master problem dual and provides new bounds and new productive columns through a modified knapsack subproblem. The overall column generation process is accelerated, even when multiple pricing is observed. Computational tests are presented using instances taken from real data from Sao Jose dos Campos' city.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method has been developed for the determination of the cocaine levels in samples of hair, using a chromatographic column internal surface reverse phase (ISRP)-C-18, for direct injection of the extracts of hair, without purification or derivation of the sample. The method allows monitoring an individual stopped for using or making cocaine. This method allowed the determination of levels of cocaine concentration in 75% of the analyzed samples of chemical dependents' hair, with cocaine detected at levels of 0.37-16.85 mug g(-1). In the other analyzed samples (25%), the drug was not detected, because the corresponding individuals told us that they consumed cocaine infrequently and in small amounts. The detection

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Carboxymethylcellulose packed in to a glass column was used to pre-concentrate metallic cations from aqueous solutions. The pre-concentrated metal cations are directly eluted from the column using 5.0 mL of 1.0 mol L -1 hydrochloric acid. The optimum pre-concentration conditions are given (glass column, 16 cm length, 0.80 cm i.d., stationary phase height of 12 cm, flow-rate, 1.5 mL min -1). The recuperation efficiency achieved is greater than 95%, while the enrichment factor is 10 for 50 mL of solution (0.50 mg L -1 each).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapid and sensitive method was developed to determine trace levels of Cd2+ ions in an aqueous medium by flame atomic absorption spectrometry, using on-line preconcentration in a mini-column packed with 100 mg of 2-aminothiazol modified silica gel (SiAT). The Cd2+ ions were sorbed at pH 5.0. The preconcentrated Cd2+ ions were directly eluted from the column to the spectrometer's nebulizer-burner system using 100 μL of 2 mol L-1 hydrochloric acid. A retention efficiency of over 95% was achieved. The enrichment factor (calculated as the ratio of slopes of the calibration graphs) obtained with preconcentrations in a mini-column packed with SiAT (A = -1.3 × 10-3 + 1.8 × 10-3 [Cd2+]) and without preconcentrations (A = 4 × 10-5 + 3.5 × 10-3[Cd2+]), was 51 and the detection limit calculated was 0.38 μg L-1. The preconcentration procedure was applied to determine trace levels of Cd in river water samples. The optimum preconcentration conditions are discussed herein.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Until mid 2006, SCIAMACHY data processors for the operational retrieval of nitrogen dioxide (NO2) column data were based on the historical version 2 of the GOME Data Processor (GDP). On top of known problems inherent to GDP 2, ground-based validations of SCIAMACHY NO2 data revealed issues specific to SCIAMACHY, like a large cloud-dependent offset occurring at Northern latitudes. In 2006, the GDOAS prototype algorithm of the improved GDP version 4 was transferred to the off-line SCIAMACHY Ground Processor (SGP) version 3.0. In parallel, the calibration of SCIAMACHY radiometric data was upgraded. Before operational switch-on of SGP 3.0 and public release of upgraded SCIAMACHY NO2 data, we have investigated the accuracy of the algorithm transfer: (a) by checking the consistency of SGP 3.0 with prototype algorithms; and (b) by comparing SGP 3.0 NO2 data with ground-based observations reported by the WMO/GAW NDACC network of UV-visible DOAS/SAOZ spectrometers. This delta-validation study concludes that SGP 3.0 is a significant improvement with respect to the previous processor IPF 5.04. For three particular SCIAMACHY states, the study reveals unexplained features in the slant columns and air mass factors, although the quantitative impact on SGP 3.0 vertical columns is not significant.