988 resultados para 2D-3D calibration
Resumo:
This PhD project focuses on the study of the early stages of bone biomineralization in 2D and 3D cultures of osteoblast-like SaOS-2 osteosarcoma cells, exposed to an osteogenic cocktail. The efficacy of osteogenic treatment was assessed on 2D cell cultures after 7 days. A large calcium minerals production, an overexpression of osteogenic markers and of alkaline phosphatase activity occurred in treated samples. TEM microscopy and cryo-XANES micro-spectroscopy were performed for localizing and characterizing Ca-depositions. These techniques revealed a different localization and chemical composition of Ca-minerals over time and after treatment. Nevertheless, the Mito stress test showed in treated samples a significant increase in maximal respiration levels associated to an upregulation of mitochondrial biogenesis indicative of an ongoing differentiation process. The 3D cell cultures were realized using two different hydrogels: a commercial collagen type I and a mixture of agarose and lactose-modified chitosan (CTL). Both biomaterials showed good biocompatibility with SaOS-2 cells. The gene expression analysis of SaOS-2 cells on collagen scaffolds indicated an osteogenic commitment after treatment. and Alizarin red staining highlighted the presence of Ca-spots in the differentiated samples. In addition, the intracellular magnesium quantification, and the X-ray microscopy on mineral depositions, suggested the incorporation of Mg during the early stages of bone formation process., SaOS-2 cells treated with osteogenic cocktail produced Ca mineral deposits also on CTL/agarose scaffolds, as confirmed by alizarin red staining. Further studies are underway to evaluate the differentiation also at the genetic level. Thanks to the combination of conventional laboratory methods and synchrotron-based techniques, it has been demonstrated that SaOS-2 is a suitable model for the study of biomineralization in vitro. These results have contributed to a deeper knowledge of biomineralization process in osteosarcoma cells and could provide new evidences about a therapeutic strategy acting on the reversibility of tumorigenicity by osteogenic induction.
Resumo:
Dopamine is a neurotransmitter which has a role in several psychiatric and neurological disorders. In-vivo detection of its concentration at the microscopic scale would benefit the study of these conditions and help in the development of therapies. The ideal sensor would be biocompatible, able to probe concentrations in microscopic volumes and sensitive to the small physiological concentrations of this molecule (10 nM - 1 μM). The ease of oxidation of dopamine makes it possible to detect it by electrochemical methods. An additional requirement in this kind of experiments when run in water, though, is to have a large potential window inside which no redox reactions with water take place. A promising class of materials which are being explored is the one of pyrolyzed photoresists. Photoresists can be lithographically patterned with micrometric resolution and after pyrolysis leave a glassy carbon material which is conductive, biocompatible and has a large electrochemical water window. In this work I developed a fabrication procedure for microelectrode arrays with three dimensional electrodes, making the whole device using just a negative photoresist called SU8. Making 3D electrodes could be a way to enhance the sensitivity of the electrodes without occupying a bigger footprint on the device. I characterized the electrical, morphological, and electrochemical properties of these electrodes, in particular their sensitivity to dopamine. I also fabricated and tested a two dimensional device for comparison. The three dimensional devices fabricated showed inferior properties to their two dimensional counter parts. I found a possible explanation and suggested some ways in which the fabrication could be improved.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
This study presents a solid-like finite element formulation to solve geometric non-linear three-dimensional inhomogeneous frames. To achieve the desired representation, unconstrained vectors are used instead of the classic rigid director triad; as a consequence, the resulting formulation does not use finite rotation schemes. High order curved elements with any cross section are developed using a full three-dimensional constitutive elastic relation. Warping and variable thickness strain modes are introduced to avoid locking. The warping mode is solved numerically in FEM pre-processing computational code, which is coupled to the main program. The extra calculations are relatively small when the number of finite elements. with the same cross section, increases. The warping mode is based on a 2D free torsion (Saint-Venant) problem that considers inhomogeneous material. A scheme that automatically generates shape functions and its derivatives allow the use of any degree of approximation for the developed frame element. General examples are solved to check the objectivity, path independence, locking free behavior, generality and accuracy of the proposed formulation. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
The paper is devoted to an experimental study of the effect of a shallow 3D roughness element on the evolution of a 2D Tollmien-Schlichting wave in a Blasius boundary layer. The experiments were carried out under controlled disturbance conditions on an airfoil section which could provide a long run with zero pressure gradient flow. A pneumatically driven slit source was used to introduce the Tollmien-Schilichting wave upstream of the lower branch of the neutral stability curve. A few wavelengths downstream, the T-S wave interacts with a cylindrical roughness element. The height of the roughness was slowly oscillating in time, which allows a continuous measurement of the T-S wave response downstream the roughness. The oscillation frequency was approximately 1500 times lower than the frequency of the studied Tollmien-Schlichting wave and therefore, behaved as a steady roughness with respect to the T-S wave. Hot wire anemometry was used to measure wall normal profiles and spanwise scans close to the maximum of the eigenfunction of the T-S wave. The oscillation of the roughness and the synchronization of all-equipments permitted the use of ensemble average techniques. Two different amplitudes of T-S waves with a non-dimensional frequency of F120E-06 were studied. They show a strong amplification of the disturbances in a small spanwise wave number range. The analysis of the wall normal T-S profiles suggests the growth of oblique modes.
Resumo:
Axial X-ray Computed tomography (CT) scanning provides a convenient means of recording the three-dimensional form of soil structure. The technique has been used for nearly two decades, but initial development has concentrated on qualitative description of images. More recently, increasing effort has been put into quantifying the geometry and topology of macropores likely to contribute to preferential now in soils. Here we describe a novel technique for tracing connected macropores in the CT scans. After object extraction, three-dimensional mathematical morphological filters are applied to quantify the reconstructed structure. These filters consist of sequences of so-called erosions and/or dilations of a 32-face structuring element to describe object distances and volumes of influence. The tracing and quantification methodologies were tested on a set of undisturbed soil cores collected in a Swiss pre-alpine meadow, where a new earthworm species (Aporrectodea nocturna) was accidentally introduced. Given the reduced number of samples analysed in this study, the results presented only illustrate the potential of the method to reconstruct and quantify macropores. Our results suggest that the introduction of the new species induced very limited chance to the soil structured for example, no difference in total macropore length or mean diameter was observed. However. in the zone colonised by, the new species. individual macropores tended to have a longer average length. be more vertical and be further apart at some depth. Overall, the approach proved well suited to the analysis of the three-dimensional architecture of macropores. It provides a framework for the analysis of complex structures, which are less satisfactorily observed and described using 2D imaging. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
In the last years, it has become increasingly clear that neurodegenerative diseases involve protein aggregation, a process often used as disease progression readout and to develop therapeutic strategies. This work presents an image processing tool to automatic segment, classify and quantify these aggregates and the whole 3D body of the nematode Caenorhabditis Elegans. A total of 150 data set images, containing different slices, were captured with a confocal microscope from animals of distinct genetic conditions. Because of the animals’ transparency, most of the slices pixels appeared dark, hampering their body volume direct reconstruction. Therefore, for each data set, all slices were stacked in one single 2D image in order to determine a volume approximation. The gradient of this image was input to an anisotropic diffusion algorithm that uses the Tukey’s biweight as edge-stopping function. The image histogram median of this outcome was used to dynamically determine a thresholding level, which allows the determination of a smoothed exterior contour of the worm and the medial axis of the worm body from thinning its skeleton. Based on this exterior contour diameter and the medial animal axis, random 3D points were then calculated to produce a volume mesh approximation. The protein aggregations were subsequently segmented based on an iso-value and blended with the resulting volume mesh. The results obtained were consistent with qualitative observations in literature, allowing non-biased, reliable and high throughput protein aggregates quantification. This may lead to a significant improvement on neurodegenerative diseases treatment planning and interventions prevention
Resumo:
One of the current frontiers in the clinical management of Pectus Excavatum (PE) patients is the prediction of the surgical outcome prior to the intervention. This can be done through computerized simulation of the Nuss procedure, which requires an anatomically correct representation of the costal cartilage. To this end, we take advantage of the costal cartilage tubular structure to detect it through multi-scale vesselness filtering. This information is then used in an interactive 2D initialization procedure which uses anatomical maximum intensity projections of 3D vesselness feature images to efficiently initialize the 3D segmentation process. We identify the cartilage tissue centerlines in these projected 2D images using a livewire approach. We finally refine the 3D cartilage surface through region-based sparse field level-sets. We have tested the proposed algorithm in 6 noncontrast CT datasets from PE patients. A good segmentation performance was found against reference manual contouring, with an average Dice coefficient of 0.75±0.04 and an average mean surface distance of 1.69±0.30mm. The proposed method requires roughly 1 minute for the interactive initialization step, which can positively contribute to an extended use of this tool in clinical practice, since current manual delineation of the costal cartilage can take up to an hour.
Resumo:
This paper reports on the creation of an interface for 3D virtual environments, computer-aided design applications or computer games. Standard computer interfaces are bound to 2D surfaces, e.g., computer mouses, keyboards, touch pads or touch screens. The Smart Object is intended to provide the user with a 3D interface by using sensors that register movement (inertial measurement unit), touch (touch screen) and voice (microphone). The design and development process as well as the tests and results are presented in this paper. The Smart Object was developed by a team of four third-year engineering students from diverse scientific backgrounds and nationalities during one semester.
Resumo:
Oceans - San Diego, 2013
Resumo:
This work presents an automatic calibration method for a vision based external underwater ground-truth positioning system. These systems are a relevant tool in benchmarking and assessing the quality of research in underwater robotics applications. A stereo vision system can in suitable environments such as test tanks or in clear water conditions provide accurate position with low cost and flexible operation. In this work we present a two step extrinsic camera parameter calibration procedure in order to reduce the setup time and provide accurate results. The proposed method uses a planar homography decomposition in order to determine the relative camera poses and the determination of vanishing points of detected lines in the image to obtain the global pose of the stereo rig in the reference frame. This method was applied to our external vision based ground-truth at the INESC TEC/Robotics test tank. Results are presented in comparison with an precise calibration performed using points obtained from an accurate 3D LIDAR modelling of the environment.
Resumo:
Ao longo dos últimos anos, os scanners 3D têm tido uma utilização crescente nas mais variadas áreas. Desde a Medicina à Arqueologia, passando pelos vários tipos de indústria, ´e possível identificar aplicações destes sistemas. Essa crescente utilização deve-se, entre vários factores, ao aumento dos recursos computacionais, à simplicidade e `a diversidade das técnicas existentes, e `as vantagens dos scanners 3D comparativamente com outros sistemas. Estas vantagens são evidentes em áreas como a Medicina Forense, onde a fotografia, tradicionalmente utilizada para documentar objectos e provas, reduz a informação adquirida a duas dimensões. Apesar das vantagens associadas aos scanners 3D, um factor negativo é o preço elevado. No âmbito deste trabalho pretendeu-se desenvolver um scanner 3D de luz estruturada económico e eficaz, e um conjunto de algoritmos para o controlo do scanner, para a reconstrução de superfícies de estruturas analisadas, e para a validação dos resultados obtidos. O scanner 3D implementado ´e constituído por uma câmara e por um projector de vídeo ”off-the-shelf”, e por uma plataforma rotativa desenvolvida neste trabalho. A função da plataforma rotativa consiste em automatizar o scanner de modo a diminuir a interação dos utilizadores. Os algoritmos foram desenvolvidos recorrendo a pacotes de software open-source e a ferramentas gratuitas. O scanner 3D foi utilizado para adquirir informação 3D de um crânio, e o algoritmo para reconstrução de superfícies permitiu obter superfícies virtuais do crânio. Através do algoritmo de validação, as superfícies obtidas foram comparadas com uma superfície do mesmo crânio, obtida por tomografia computorizada (TC). O algoritmo de validação forneceu um mapa de distâncias entre regiões correspondentes nas duas superfícies, que permitiu quantificar a qualidade das superfícies obtidas. Com base no trabalho desenvolvido e nos resultados obtidos, é possível afirmar que foi criada uma base funcional para o varrimento de superfícies 3D de estruturas, apta para desenvolvimento futuro, mostrando que é possível obter alternativas aos métodos comerciais usando poucos recursos financeiros.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica
Resumo:
Dissertation to obtain master degree in Biotechnology