390 resultados para 1284
Resumo:
Nearly half of the US population faces the risk of developing knee osteoarthritis (OA). Both in vitro and in vivo studies can aid in a better understanding of the etiology, progression, and advancement of this debilitating disorder. The knee menisci are fibrocartilagenous structures that aid in the distribution of load, attenuation of shock, alignment and lubrication of the knee. Little is known about the biochemical and morphological changes associated with knee menisci following altered loading and traumatic impaction, and investigations are needed to further elucidate how degradation of this soft tissue advances over time. The biochemical response of porcine meniscal explants was investigated following a single bout of dynamic compression with and without the treatment of the pharmaceutical drug, anakinra (IL-1RA). Dynamic loading led to a strain-dependent response in both anabolic and catabolic gene expression of meniscal explants. By inhibiting the Interleukin-1 pathway with IL-1RA, a marked decrease in several catabolic molecules was found. From these studies, future developments in OA treatments may be developed. The implementation of an in vivo animal model contributes to the understanding of how the knee joint behaves as a whole. A novel closed-joint in vivo model that induces anterior cruciate ligament (ACL) rupture has been developed to better understand how traumatic injury leads to OA. The menisci of knees from three different groups (healthy, ACL transected, and traumatically impacted) were characterized using histomorphometry. The acute and chronic changes within the knee following traumatic impaction were investigated. The works presented in this dissertation have focused on the characterization, implementation, and development of mechanically-induced changes to the knee menisci.
Resumo:
The Livingston formation is a thick succession of late Cretaceous lava flows, tuffs, and bedded water-laid volcanic detritus 200 miles long and 100 miles wide lying along the eastern margin of the Rocky Mountains in western Montana from Augusta to Yellowstone Park. It differs markedly within short distances in lithologic character and sequences, and the total thickness may exceed one mile in some places.
Resumo:
The identification and accurate location of centers of brain activity are vital both in neuro-surgery and brain research. This study aimed to provide a non-invasive, non-contact, accurate, rapid and user-friendly means of producing functional images intraoperatively. To this end a full field Laser Doppler imager was developed and integrated within the surgical microscope and perfusion images of the cortical surface were acquired during awake surgery whilst the patient performed a predetermined task. The regions of brain activity showed a clear signal (10-20% with respect to the baseline) related to the stimulation protocol which lead to intraoperative functional brain maps of strong statistical significance and which correlate well with the preoperative fMRI and intraoperative cortical electro-stimulation. These initial results achieved with a prototype device and wavelet based regressor analysis (the hemodynamic response function being derived from MRI applications) demonstrate the feasibility of LDI as an appropriate technique for intraoperative functional brain imaging.
Resumo:
Two hundred and eighty-five botanically identifide plant materials have been extracted with 50 percent ethanol and the extracts put through a wide biological screen of 61 tests. These include tests for antibacterial, antifungal, anthelminthic, antiprotozoal, anticancer, antifertillity, hypoglycaemic and a wide range of pharmacological activities.
Resumo:
Aims: To assess observations with multimodality imaging of the Absorb bioresorbable everolimus-eluting vascular scaffold performed in two consecutive cohorts of patients who were serially investigated either at 6 and 24 months or at 12 and 36 months. Methods and results: In the ABSORB multicentre single-arm trial, 45 patients (cohort B1) and 56 patients (cohort B2) underwent serial invasive imaging, specifically quantitative coronary angiography (QCA), intravascular ultrasound (IVUS), radiofrequency backscattering (IVUS-VH) and optical coherence tomography (OCT). Between one and three years, late luminal loss remained unchanged (6 months: 0.19 mm, 1 year: 0.27 mm, 2 years: 0.27 mm, 3 years: 0.29 mm) and the in-segment angiographic restenosis rate for the entire cohort B (n=101) at three years was 6%. On IVUS, mean lumen, scaffold, plaque and vessel area showed enlargement up to two years. Mean lumen and scaffold area remained stable between two and three years whereas significant reduction in plaque behind the struts occurred with a trend toward adaptive restrictive remodelling of EEM. Hyperechogenicity of the vessel wall, a surrogate of the bioresorption process, decreased from 23.1% to 10.4% with a reduction of radiofrequency backscattering for dense calcium and necrotic core. At three years, the count of strut cores detected on OCT increased significantly, probably reflecting the dismantling of the scaffold; 98% of struts were covered. In the entire cohort B (n=101), the three-year major adverse cardiac event rate was 10.0% without any scaffold thrombosis. Conclusions: The current investigation demonstrated the dynamics of vessel wall changes after implantation of a bioresorbable scaffold, resulting at three years in stable luminal dimensions, a low restenosis rate and a low clinical major adverse cardiac events rate.
Resumo:
HYPOTHESIS A previously developed image-guided robot system can safely drill a tunnel from the lateral mastoid surface, through the facial recess, to the middle ear, as a viable alternative to conventional mastoidectomy for cochlear electrode insertion. BACKGROUND Direct cochlear access (DCA) provides a minimally invasive tunnel from the lateral surface of the mastoid through the facial recess to the middle ear for cochlear electrode insertion. A safe and effective tunnel drilled through the narrow facial recess requires a highly accurate image-guided surgical system. Previous attempts have relied on patient-specific templates and robotic systems to guide drilling tools. In this study, we report on improvements made to an image-guided surgical robot system developed specifically for this purpose and the resulting accuracy achieved in vitro. MATERIALS AND METHODS The proposed image-guided robotic DCA procedure was carried out bilaterally on 4 whole head cadaver specimens. Specimens were implanted with titanium fiducial markers and imaged with cone-beam CT. A preoperative plan was created using a custom software package wherein relevant anatomical structures of the facial recess were segmented, and a drill trajectory targeting the round window was defined. Patient-to-image registration was performed with the custom robot system to reference the preoperative plan, and the DCA tunnel was drilled in 3 stages with progressively longer drill bits. The position of the drilled tunnel was defined as a line fitted to a point cloud of the segmented tunnel using principle component analysis (PCA function in MatLab). The accuracy of the DCA was then assessed by coregistering preoperative and postoperative image data and measuring the deviation of the drilled tunnel from the plan. The final step of electrode insertion was also performed through the DCA tunnel after manual removal of the promontory through the external auditory canal. RESULTS Drilling error was defined as the lateral deviation of the tool in the plane perpendicular to the drill axis (excluding depth error). Errors of 0.08 ± 0.05 mm and 0.15 ± 0.08 mm were measured on the lateral mastoid surface and at the target on the round window, respectively (n =8). Full electrode insertion was possible for 7 cases. In 1 case, the electrode was partially inserted with 1 contact pair external to the cochlea. CONCLUSION The purpose-built robot system was able to perform a safe and reliable DCA for cochlear implantation. The workflow implemented in this study mimics the envisioned clinical procedure showing the feasibility of future clinical implementation.
Resumo:
A search is presented for production of a heavy up-type quark (t') together with its antiparticle, assuming a significant branching ratio for subsequent decay into a W boson and a b quark. The search is based on 4.7 fb(-1) of pp collisions root s = 7 TeV recorded in 2011 with the ATLAS detector at the CERN Large Hadron Collider. Data are analyzed in the lepton + jets final state, characterized by a high-transverse-momentum isolated electron or muon, large missing transverse momentum and at least three jets. The analysis strategy relies on the substantial boost of the W bosons in the t'(t') over bar signal when m(t') greater than or similar to 400 GeV. No significant excess of events above the Standard Model expectation is observed and the result of the search is interpreted in the context of fourth-generation and vector-like quark models. Under the assumption of a branching ratio BR(t' -> W b) = I, a fourth-generation t' quark with mass lower than 656 GeV is excluded at 95% confidence level. In addition, in light of the recent discovery of a new boson of mass similar to 126 GeV at the LHC, upper limits are derived in the two-dimensional plane of BR(t' -> Wb) versus BR(t' -> Ht), where H is the Standard Model Higgs boson, for vector-like quarks of various masses.
Resumo:
Aims: Stents with a passive coating of titanium-nitride-oxide (TiNO) have been compared with Endeavor® zotarolimus-eluting stents (E-ZES) with regard to the primary endpoint of in-stent late lumen loss at six to eight months. The objective of the present analysis was to compare the long-term outcomes of TiNO stents with E-ZES up to five years of clinical follow-up. Methods and results: A total of 302 patients had been randomly allocated to treatment with TiNO or E-ZES. Up to five years of follow-up, major adverse cardiac events (MACE), the composite of cardiac death, myocardial infarction, or clinically indicated target vessel revascularisation (TLR), were observed in 27.6% of patients treated with TiNO stents and 25.3% of patients treated with E-ZES (RR 1.13, 95% CI: 0.72-1.75, p=0.60), with the majority of events related to clinically indicated TVR (TiNO 21.7% versus E-ZES 20.7%, RR 1.10, 95% CI: 0.67-1.81). There were no differences with respect to individual events including cardiac death, myocardial infarction or stent thrombosis between the two treatment arms up to five years of follow-up. A majority of patients remained free from angina throughout the entire study duration (TiNO 77.3% versus E-ZES 76.1%, p=0.92). Conclusions: Final five-year outcomes of the TIDE trial comparing TiNO stents with E-ZES revealed increased rates of MACE driven primarily by clinically indicated TVR. The TIDE trial is registered at ClinicalTrials.gov: NCT00492908.
Resumo:
Tanzkritiken spiegeln zum Zeitpunkt ihrer Erstpublikation in Zeitungen oder Zeitschriften künstlerische Aktualität. Die Tanzwissenschaft wiederum greift später auf diese Kritiken als Quellen zurück und hat dabei deren mediale, historische und kontextuelle Eigenheiten zu berücksichtigen. Die Autorin fokussiert einerseits auf die Eigenheiten der Praxis des Schreibens von Tanzkritiken, andererseits auf die Fruchtbarmachung der Tanzkritik als Quelle für die Wissenschaft. Beide Bereiche, Tanzkritik und Tanzwissenschaft, werden als Reflexionsinstrumente je füreinander produktiv gemacht. Der Materialienband verbindet drei Herangehensweisen: ein historiografisches Interesse, eine fachspezifisch (selbst)reflexive Diskursanalyse und einen praktischen, handlungsanleitenden Ansatz. Die Autorin stellt verschiedene Traditionen und Stile der Tanzkritik dar, vermittelt die eigenen Erfahrungen als Wissenschaftlerin und als Journalistin mit der Textsorte Tanzkritik und will entsprechend sensibilisieren. Ein kommentiertes Korpus ausgewählter Tanzkritiken gibt einen Einblick ins Tanzgeschehen der Jahrtausendwende.
Resumo:
Gastroschisis is a birth defect in which an opening in the abdominal wall allows herniation of the viscera. Prenatal counseling regarding gastroschisis typically discusses that, although these infants often endure a difficult neonatal course, they experience few long-term complications. However, information regarding long-term outcomes is based on limited studies that lack specificity. Therefore, we aimed to study the long-term morbidity and quality of life in children born with gastroschisis in a large and diverse population drawn from the Texas Birth Defects Registry (TBDR). Study packets with informed consent, a questionnaire, and the Pediatric Quality of Life Inventory Generic Core Scale 4.0 (PedsQL 4.0) in English and Spanish were mailed to 1,112 parents of children born with isolated gastroschisis in Texas between 1999 and 2008 via the TBDR. Information was abstracted from the TBDR for 58 mothers of children with gastroschisis who returned study materials. Three hundred fifty five packets were returned to sender, giving a response rate of 7.7%. Children born with gastroschisis had quality of life scores that were not significantly different than expected (p = 0.981). However, factors such as having a learning disability (p = 0.001) and missing school due to gastrointestinal issues (p = 0.020) were found to significantly decrease quality of life. Overall, children with gastroschisis had a significantly increased risk for learning disabilities regardless of whether they were preterm (p = 0.021) or full term (p = 0.021). Additionally, there appeared to be an increased risk for auditory impairment in Caucasian children (p < 0.0005). Therefore, while overall long-term quality of life is not significantly altered for children born with gastroschisis, the previously unreported increased risk for learning disabilities and possible association with hearing impairment are important findings that should be conveyed to prospective parents.