966 resultados para [ppm]


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dependence of performances of non-line-of-sight (NLOS) solar-blind ultraviolet (UV) communication systems on atmosphere visibility is investigated numerically by correlating the propagation of UV radiation with the visibility. A simplified solar-blind UV atmospheric propagation model is introduced, and the NLOS UV communication system model is constituted based on the single scattering assumption. Using the model, numerical simulation is conducted for two typical geometry configurations and different modulation formats. The results indicate that the performance of the NLOS UV communication system is insensitive to variation of visibility in quite a large range, and deteriorates significantly only in very low-visibility weather, and is also dependent on the geometry configuration of the system. The results also show that the pulse position modulation (PPM) is preferable due to its high-power efficiency to improve the system performance. (c) 2007 Elsevier GmbH. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El objetivo que persigue la línea de investigación en la que se engloba este trabajo es la obtención de hidrógeno desde disoluciones acuosas de metanol (aproximadamente del 10% de metanol), considerando estos compuestos como una forma de almacenar hidrógeno y obtenerlo a baja temperatura “on-board” en un vehículo mediante el reformado en fase acuosa. El reto es conseguir un sistema catalítico de pequeño volumen y rápida respuesta a las demandas de hidrógeno con elevado rendimiento y calidad apropiada (<10 ppm de CO) para las pilas de combustible PEM. Los objetivos planteados en el siguiente trabajo se centran en la preparación y caracterización de un catalizador de platino soportado en alúmina, y la puesta en marcha de un reactor discontinuo de mezcla perfecta a presión para la evaluación de catalizadores en el proceso de reformado en fase líquida.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Apesar do potencial anticárie do dentifrício fluoretado na dentição permanente estar bem estabelecido, existe uma lacuna no conhecimento em relação ao seu efeito na dentição decídua; não existe consenso quanto à concentração ideal de fluoreto no dentifrício capaz de maximizar o benefício anticárie na dentição decídua e simultaneamente minimizar o risco de desenvolver fluorose clinicamente importante na dentição permanente. O artigo 1 desta tese avaliou o efeito dos dentifrícios de concentração baixa (menos de 600 ppm) e padrão (1000 a 1500 ppm) de fluoreto comparados com placebo ou nenhuma intervenção e o artigo 2 comparou diretamente o efeito do dentifrício de concentração baixa de fluoreto com o de concentração padrão. Foi realizada uma revisão sistemática de ensaios clínicos randomizados ou quasi-randomizados. Dois examinadores leram, de forma independente, 1932 resumos ou citações e 159 estudos na íntegra. As discordâncias foram resolvidas por um terceiro examinador. Oito estudos foram incluídos no artigo 1 e cinco no artigo 2. Para avaliar o efeito dos dentifrícios fluoretados sobre o número de dentes e superfícies dentárias cariadas, perdidas por cárie e obturadas, e sobre o número de crianças com cárie e fluorose, foram estimados frações prevenidas (FP) e riscos relativos (RR) combinados, respectivamente. Quando os dentifrícios de concentração padrão de fluoreto foram comparados com placebo ou nenhuma intervenção, houve reduções significativas de cárie no nível de superfície (FP= 31%; IC 95% 18 43), dente (FP= 16%; IC 95% 7 24) e indivíduo (RR= 0,86; IC 95% 0,81 0,93). Quando os dentifrícios de concentração baixa de fluoreto foram comparados com nenhuma intervenção, houve redução significativa de cárie apenas no nível de superfície (FP= 40%; IC 95% 5 75) (artigo 1). Os dentifrícios de concentração baixa de fluoreto, comparados diretamente com os de concentração padrão, aumentaram significativamente o risco de cárie na dentição decídua (RR= 1,13; IC 95% 1,07 1,20) e não reduziram significativamente o risco de fluorose clinicamente importante nos dentes permanentes anteriores superiores (RR= 0,32; IC 95% 0,03 2,97). Houve uma redução significativa de cárie no nível de dente quando o dentifrício com concentração padrão de fluoreto foi comparado com o de baixa concentração (FP=14%; IC 95% 6 21). Porém, não houve diferença no nível de superfície, apesar de ter havido uma tendência favorecendo os dentifrícios com concentração padrão de fluoreto e pH neutro (FP= 13%; IC 95% -4 30) e os de concentração baixa de fluoreto e pH ácido (FP= -5%; IC 95% -22 11) (artigo 2). Os dentifrícios de concentração padrão de fluoreto foram mais efetivos na redução de cárie na dentição decídua de pré-escolares do que os de concentração baixa, placebo ou nenhuma intervenção. Os dentifrícios de concentração padrão de fluoreto, em comparação com os de concentração baixa, não aumentaram significativamente o risco de fluorose clinicamente importante nos dentes permanentes anteriores superiores. São necessários mais estudos para confirmar se a redução do pH dos dentifrícios de concentração baixa de fluoreto pode ser considerada uma alternativa para aumentar o efeito anticárie e reduzir o risco de fluorose clinicamente importante.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Neste estudo, a sorção e recuperação de íons metálicos de resíduos sólidos industriais provenientes de uma indústria de galvanoplastia situada no Rio de Janeiro (Brasil) foram investigadas através da utilização de duas resinas comerciais de troca iônica: Lewatit VPOC 1800 (fortemente ácida, tipo gel) e Lewatit VPOC 1960 (fortemente básica, tipo gel), produzidas pela Lanxess-Bayer Chemicals. As características físico-quimicas das resinas e do lodo galvânico foram determinadas. Os estudos de sorção das resinas foram conduzidos em batelada e em coluna. Baseado nesses estudos, os parâmetros de sorção e das curvas de ruptura foram determinados. Os estudos de equilíbrio e cinética de sorção tamm foram realizados. O resíduo de galvanoplastia era composto pelos metais: Cu2+, Fe3+, Al3+, Ni2+ e Cr3+. A capacidade de sorção qe das resinas Lewatit VPOC 1800 variou entre 0,1-1,9 mg g-1 para Cu2+, 0,01-0,6 mg g-1 para Fe3+ e 0,2-0,4 mg g-1 para Al3+. Enquanto que para a resina Lewatit VPOC 1960, os valores de qe variou entre 0,01-0,4 mg g-1 para Cu2+ e 0,01 0,2 mg g-1 para Fe3+ dependendo da concentração do metal e do tempo de contato. A capacidade de sorção para a resina Lewatit VPOC 1960 foi restrita para íons Cu2+ e Fe3+ os quais formam complexos aniônicos com íons Cl-. O modelo de Freundlich foi o mais adequado para descrever o equilíbrio de troca iônica de ambas as resinas. Já em relação ao mecanismo de sorção, o modelo pseudo-segunda ordem tipo 1 foi o mais aplicável. O ponto de ruptura das resinas Lewatit VPOC 1800 e Lewatit VPOC 1960 em relação aos íons Cu2+ocorreu quando passou através da coluna, 1860 cm3 e 2220 cm3 de solução de resíduo sólido respectivamente (20 g de resina, 100 mg L-1 de íons Cu2+, vazão de 60 cm3 min-1). Os íons metálicos Cu2+, Fe3+, Al3+, foram dessorvidos em alta proporção da resina Lewatit VPOC 1800 passando pela coluna solução aquosa de H2SO4 2,4 mol L-1. Já os metais Cu2+ e Fe3+ foram eluídos da resina Lewatit VPOC 1960 com solução aquosa de HCl 2,0 mol L-1. A recuperação seletiva de Cu2+ não foi alcançada porque Cu2+ e Fe3+ precipitam na mesma faixa de pH

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Processos corrosivos geram perdas incalculáveis para a sociedade. Existe, portanto, uma incessante busca por métodos cada vez mais econômicos, eficientes e que não gerem impacto ao meio-ambiente. Polímeros heterocíclicos são macromoléculas de elevada performance que vêm sendo estudados como inibidores de corrosão por atenderem as premissas citadas acima. Neste trabalho realizou-se a modificação química da poliacrilonitrila com a incorporação de grupos 2-vinil-2-oxazolina no teor teórico de 20%. O copolímero obtido e a poliacrilonitrila não modificada foram caracterizados por espectroscopia na região do infravermelho e avaliados como inibidores de corrosão para alumínio e aço carbono em meio salino em temperatura de 60C. As concentrações utilizadas foram de 20, 50, 100 e 200 ppm e os períodos de checagem: 1, 2, 3 e 4 semanas. Os polímeros estudados apresentaram atividade inibitória de corrosão apenas para o aço carbono. Para o alumínio, o ensaio em branco apresentou a menor taxa de corrosão dentre todos os ensaios realizados

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The local structure of Na-Al-P-O-F glasses, prepared by a novel sol-gel route, was extensively investigated by advanced solid-state NMR techniques. Al-21{F-19} rotational echo double resonance (REDOR) results indicate that the F incorporated into aluminophosphate glass is preferentially bonded to octahedral Al units and results in a significant increase in the concentration of six-coordinated aluminum. The extent of Al-F and Al-O-P connectivities are quantified consistently by analyzing Al-27{P-31} and Al-21{F-19} REDOR NMR data. Two distinct types of fluorine species were identified and characterized by various F-19{Al-27}, F-19{Na-23}, and F-19{P-31} double resonance experiments, which were able to support peak assignments to bridging (Al-F-Al, -140 ppm) and terminal (Al-F, -170 ppm) units. On the basis of the detailed quantitative dipole-dipole coupling information obtained, a comprehensive structural model for these glasses is presented, detailing the structural speciation as a function of composition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A compact nonporous high silica (SiO2 % > 96%) glass containing 3400 ppm Er3+ ions, which was about ten times higher than that in Er-doped silica fiber amplifier (EDSFA), was synthesized by sintering porous glass immersed into erbium nitrate solution. The 1532 nm fluorescence has a FWHM (Full Width at Half Maximum) of 45 nm wider than that of EDSFA and possesses the glass with potential application in broadband fiber amplifiers. The Judd-Ofelt theoretical analysis reflects that Er3+ ions are located in a higher covalent environment which are comparable to those of aluminosilicate glass. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

alpha-Al2O3:C crystal shows excellent thermoluminescence (TL) and optically stimulated luminescence (OSL) properties but the real role carbon plays in this crystal is still not clearly understood so far. In this work, alpha-Al2O3:C crystal doping with different amounts of carbon were grown by the temperature gradient technique, and TL and OSL properties of as-grown crystals were investigated. Additionally, a mechanism was proposed to explain the role of carbon in forming the TL and OSL properties of alpha-Al2O3:C. TL and OSL intensities of as-grown crystals increase with the increasing amount of carbon doping in the crystal, but no shift is found in the glow peak location at 465 K. As the amount of carbon doping in the crystals decreases, OSL decay rate becomes faster. With the increase in heating rate, the integral TL response of as-grown crystals decreases and glow peak shifts to higher temperatures. TL response decrease rate increases with the increasing amount of carbon doping in the crystals. All the TL and OSL response curves of as-grown crystals show linear-sublinear-saturation characteristic, and OSL dose response exhibits higher sensitivity and wider linear dose range than that of TL. The crystal doping with 5000 ppm carbon shows the best dosimetric properties. Carbon plays the role of a dopant in alpha-Al2O3:C crystal and four-valent carbon anions replace the two-valent anions of oxygen during the crystal growth process, and large amounts of oxygen vacancies were formed, which corresponds to the high absorption coefficient of F and F+ centers in the crystals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ZrO2, films were deposited by electron-beam evaporation with the oxygen partial pressure varying from 3 X 10(-3) Pa to I I X 10(-3) Pa. The phase structure of the samples was characterized by x-ray diffraction (XRD). The thermal absorption of the films was measured by the surface thermal lensing technique. A spectrophotometer was employed to measure the refractive indices of the samples. The laser-induced damage threshold (LIDT) was assessed using a 1064, nm Nd: yttritium-aluminium-garnet pulsed laser at pulse width of 12 ns. The influence of oxygen partial pressure on the microstructure and LIDT of ZrO2 films was investigated. XRD data revealed that the films changed from polycrystalline to amorphous as the oxygen partial pressure increased. The variation of refractive index at 550 nm wavelength indicated that the packing density of the films decreased gradually with increasing oxygen partial pressure. The absorptance of the samples decreased monotonically from 125.2 to 84.5 ppm with increasing oxygen partial pressure. The damage threshold, values increased from 18.5 to 26.7 J/cm(2) for oxygen partial pressures varying from 3 X 10(-3) Pa to 9 X 10(-3) Pa, but decreased to 17.3 J/cm(2) in the case of I I X 10(-3) Pa. (C) 2005 American Vacuum Society.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ZrO2, films were deposited by electron-beam evaporation with the oxygen partial pressure varying from 3 X 10(-3) Pa to I I X 10(-3) Pa. The phase structure of the samples was characterized by x-ray diffraction (XRD). The thermal absorption of the films was measured by the surface thermal lensing technique. A spectrophotometer was employed to measure the refractive indices of the samples. The laser-induced damage threshold (LIDT) was assessed using a 1064, nm Nd: yttritium-aluminium-garnet pulsed laser at pulse width of 12 ns. The influence of oxygen partial pressure on the microstructure and LIDT of ZrO2 films was investigated. XRD data revealed that the films changed from polycrystalline to amorphous as the oxygen partial pressure increased. The variation of refractive index at 550 nm wavelength indicated that the packing density of the films decreased gradually with increasing oxygen partial pressure. The absorptance of the samples decreased monotonically from 125.2 to 84.5 ppm with increasing oxygen partial pressure. The damage threshold, values increased from 18.5 to 26.7 J/cm(2) for oxygen partial pressures varying from 3 X 10(-3) Pa to 9 X 10(-3) Pa, but decreased to 17.3 J/cm(2) in the case of I I X 10(-3) Pa. (C) 2005 American Vacuum Society.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We prepare HfO2 thin films by electron beam evaporation technology. The samples are annealed in air after deposition. With increasing annealing temperature, it is found that the absorption of the samples decreases firstly and then increases. Also, the laser-induced damage threshold (LIDT) increases firstly and then decreases. When annealing temperature is 473K, the sample has the highest LIDT of 2.17J/cm(2), and the lowest absorption of 18 ppm. By investigating the optical and structural characteristics and their relations to LIDT, it is shown that the principal factor dominating the LIDT is absorption.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

为提高表面热透镜薄膜吸收测量仪的灵敏度,在表面热透镜衍射理论基础上,通过数值模拟给出了探测激光腰斑半径、探测激光腰斑到样品表面距离、样品到探测光纤端面距离等仪器参数的优化方法.经优化调整后该仪器能达到优于0.1ppm量级的薄膜吸收率测量灵敏度.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The single-sided and dual-sided high reflective mirrors were deposited with ion-beam sputtering (IBS). When the incident light entered with 45 degrees, the reflectance of p-polarized light at 1064 nm exceeded 99.5%. Spectrum was gained by spectrometer and weak absorption of coatings was measured by surface thermal lensing (STL) technique. Laser-induced damage threshold (LIDT) was determined and the damage morphology was observed with Lecia-DMRXE microscope simultaneously. The profile of coatings was measured with Mark III-GPI digital interferometer. It was found that the reflectivity of mirror exceeded 99.9% and its absorption was as low as 14 ppm. The reflective bandwidth of the dual-sided sample was about 43 nm wider than that of single-sided sample, and its LIDT was as high as 28 J/cm2, which was 5 J/cm2 higher than that of single-sided sample. Moreover, the profile of dual-sided sample was better than that of substrate without coatings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

利用电子束蒸发和光电极值监控技术制备了氧化铪薄膜,并分别用两种后处理方法(空气中退火和氧等离子体轰击)对样品进行了处理.然后,对样品的透过率、吸收和抗激光损伤阈值进行了测试分析.实验结果表明,两种后处理方法都能不同程度地降低了氧化铪薄膜的吸收损耗、提高了抗激光损伤阈值.实验结果还表明,氧等离子体轰击的后处理效果明显优于热退火,样品的吸收平均值在氧等离子体后处理前后分别为34.8ppm和9.0ppm,而基频(1 064nm)激光损伤阈值分别为10.0J/cm^2和21.4J/cm^2.