737 resultados para screw loosening
Resumo:
Dissertação de mestrado integrado em Engenharia de Materiais
Resumo:
Tese de Doutoramento em Ciência e Engenharia de Polímeros e Compósitos
Resumo:
"Available online 21 March 2016"
Resumo:
Tese de Doutoramento em Ciência e Engenharia de Polímeros e Compósitos.
Resumo:
This thesis is a continuation of the Enterprise-Ireland Research Innovation Fund (RIF) Project entitled’ "Design and Manufacturing of Customised Maxillo-Facial Prostheses" The primary objective of this Internal Research Development Program (IRDP) project was to investigate two fundamental design changes 1 To incorporate the over-denture abutments directly into the implant. 2 To remove the restraining wings by the addition of screws, which affix the. implant to the dense material of the jawbone. The prosthetic was redesigned using the ANSYS Finite Element Analysis software program and analysed to* • Reduce the internal von Mises stress distribution The new prosthetic had a -63.63 % lower von Mises stress distribution when compared with the original prosthetic. • Examine the screw preload effects. A maximum relative displacement of 22 6 * lO^mm between the bone and screw was determined, which is well below the critical threshold of micromotion which prevents osseointegration • Investigate the prosthetic-bone contact interface. Three models of the screw, prosthesis, and bone, were studied. (Axisymmetnc, quarter volume, and full volume), a recommended preload torque of 0 32 Nm was applied to the prosthetic and a maximum von Mises stress of 1.988 MPa was predicted • Study the overdenture removal forces. This analysis could not be completed because the correct plastic multilinear properties of the denture material could not be established The redesigned prosthetic was successfully manufactured on a 3-axis milling machine with an indexing system The prosthetic was examined for dimensional quality and strength The research established the feasibility of the new design and associated manufacturing method.
Resumo:
Hansen's Bacillus: By electron microscopy this bacillus shows membrane and halo, this being more visible when sorrounding the globi or bundles of bacilli; shows, also, free granules of various sizes which were before considered as dust of the dyes; shows external granules bound with the membrane and some times branching. By phases contrast microscopy examining leproma suspensions and subcataneous lymph at 400 x we saw many free granules with intense rotatory movement; granulated bacilli with screw, skip or stroke motion, producing slow progressive motion. All such elementes are surrounded by a halo, corresponding to the classical gloea. By a patient and delayed examination we were able to see that the internal granules are motile and help the progression of the bacilli, giving the impression that the cytoplasm is liquid. By a lasting observation we could see the larger granules form prolapse, like a pseudopode and abandon the bacilli and going in very rapid rotatory movement. There are branched bacilli; there are pedunculated fred granules like comets. The addition of a drop of formol at the preparation stops all movements. Stefansky's Bacillus: Repeated examination by RCA electron microscope, type EMU-25 of fresh suspensions of rat lepromas, led us to confirm the close relationship between human and murine leprosy agents. We examined also material from carabo (Lepra bubalorum) from Java, but due to fixation, the material was unsuitable for comparative studies. The Stefansky's bacilli showed also emmbranes and halos, internal or external granules (smaller than those of Hansen's bacillus). The bacilli shaded by chromium look thicker and shorter than those of Hansen. Due to electron bombardment both, Hansen's and Stefansky's baccilli suffer considerable alterations in their structure, showing black barrs of chromatin condensation at their extremities as also in their centers. By phase microscopy the Stefansky's bacilli showed elements with 1, 2 (bipolar), 3 or more internal small granules, developing identical movements as those of Hansen. The globi seem to be non-motile but the free bacilli appearing around the globi show intense movement. At 1000 x the examination is less satisfactory than at 400 x. The addition of formol solution in the preparation suppresses all movements, even the brownian, but the material becomes more suitable for the study of static morphology of the bacilli. CONCLUSION - The electron and phases contrast microscopy of leprous material from different types and phases of the disease may explain some of the unknown aspects of the biology and morphology of the bacilli.
Resumo:
The plant cell wall is a strong fibrillar network that gives each cell its stable shape. It is constituted by a network of cellulose microfibrils embedded in a matrix of polysaccharides, such as xyloglucans. To enlarge, cells selectively loosen this network. Moreover, there is a pectin-rich intercellular material, the middle lamella, cementing together the walls of adjacent plant cells. Xyloglucan endotransglucosylase/hydrolases (XTHs) are a group of enzymes involved in the reorganisation of the cellulose-xyloglucan framework by catalysing cleavage and re-ligation of the xyloglucan chains in the plant cell wall, and are considered cell wall loosening agents. In the laboratory, it has been isolated and characterised a XTH gene, ZmXTH1, from an elongation root cDNA library of maize. To address the cellular function of ZmXTH1, transgenic Arabidopsis thaliana plants over-expressing ZmXTH1 (under the control of the CaMV35S promoter) were generated. The aim of the work performed was therefore the characterisation of these transgenic plants at the ultrastructural level, by transmission electron microscopy (TEM).The detailed cellular phenotype of transgenic plants was investigated by comparing ultra-thin transverse sections of basal stem of 5-weeks old plants of wild type (Col 0) and 35S-ZmXTH1 Arabidopsis plants. Transgenic plants show modifications in the cell walls, particularly a thicker middle lamella layer with respect the wild type plants, supporting the idea that the overexpression of ZmXTH1 could imply a pronounced wall-loosening. In sum, the work carried out reinforces the idea that ZmXTH1 is involved in the cell wall loosening process in maize.
Resumo:
Infections associated with implants are increasingly important in modem medicine. Biofilms are the cause that these infections are more difficult to diagnose and to cure. Particularly low-grade infections are difficult to distinguish from aseptic failure, because they often present with early loosening and persisting pain. For an accurate diagnosis, clinical signs and symptoms, laboratory markers of infection, microbiology, histology and imaging examinations are needed. The treatment goal is eradication of infection and an optimal functional result. Successful treatment requires adequate surgical procedure combined with long-term antimicrobial therapy, ideally with an agent acting on biofilms.
Resumo:
Purpose: 1. To provide an overview of the different types of internal hernia (IH) occurring after laparoscopic Roux-en-Y gastric bypass (LRYGBP) performed for morbid obesity. 2. To describe the correspondent MDCT features in relation with the underlying anatomical landmarks in order to differentiate their localisation and to direct the surgeon during following laparoscopic closure of mesenteric defects. Methods and materials: LRYGBP performed for morbid obesity is associated with less perioperative complications, shorter hospital stay and a more rapid recovery compared with the open surgical procedure. However, a relatively high incidence of IH is seen that may be due to the laparoscopic approach, but also caused by rapid weight loss with consecutive loosening of the mesenteric sutures. Results: After briefly reviewing the surgical procedure of LRYGBP (ante- versus retrocolic) we describe the exact anatomical landmarks of the different types of IH occurring at any time after operation: They are caused by surgical defects either at the level of the transverse colon mesentery, at the Petersen's space, which represents an opening between the mesocolon and jejunal mesentery, or at the enteroenterostomy site. Typical MDCT features of each IH type in axial and coronal plane as well as targeted vascular reconstructions are demonstrated. Conclusion: Exact knowledge about underlying pathophysiology and anatomical landmarks is essential for distinguishing the different types of IH occurring after LRYGBP on MDCT, since radiological features are difficult to recognize and may even overlap. The radiologist should be aware of the potential anatomic sites to ensure subsequent straightforward laparoscopic exploration.
Resumo:
Learning Objectives: 1. To provide an overview of the different types of internal hernia (IH) occurring after laparoscopic Roux‑en‑Y gastric bypass (LRYGBP) for morbid obesity. 2. To describe correspondent MDCT features in relation with the underlying anatomical landmarks in order to differentiate their localisation and to direct the surgeon during following laparoscopic closure of mesenteric defects. Background: LRYGBP for morbid obesity is associated with less perioperative complications, shorter hospital stay and a more rapid recovery compared with the open surgical procedure. However, a relatively high incidence of IH is seen that may be due to the laparoscopic approach, but also caused by rapid weight loss with consecutive loosening of the mesenteric sutures. Procedure Details: After briefly reviewing the surgical procedure of LRYGBP (ante‑ versus retrocolic), we describe the exact anatomical landmarks of the different types of IH occurring at any time after operation: They are caused by surgical defects at the level of the transverse colon mesentery, at the Petersen's space, which represents an opening between the mesocolon and jejunal mesentery, or at the entero‑enterostomy site. Typical MDCT features of each IH type in axial and coronal planes as well as targeted vascular reconstructions are demonstrated. Conclusion: Exact knowledge about underlying pathophysiology and anatomical landmarks is essential for distinguishing the different types of IH occurring after LRYGBP on MDCT, since radiological features are difficult to recognize and may even overlap. The radiologist should be aware of the potential anatomic sites to ensure subsequent straightforward laparoscopic exploration.
Resumo:
INTRODUCTION: The risk that hip preserving surgery may negatively influence the performance and outcome of subsequent total hip replacement (THR) remains a concern. The aim of this study was to identify any negative impact of previous hip arthroscopy on THR. METHODS: Out of 1271 consecutive patients who underwent primary THR between 2005 and 2009, 18 had previously undergone ipsilateral hip arthroscopy. This study group (STG) was compared with two control groups (CG, same approach, identical implants; MCG, paired group matched for age, BMI and Charnley categories). Operative time, blood loss, evidence of heterotopic bone and implant loosening at follow-up were compared between the STG and the MCG. Follow-up WOMAC were compared between the three groups. RESULTS: Blood loss was not found to be significantly different between the STG and MCG. The operative time was significantly less (p < 0.001) in the STG. There was no significant difference in follow-up WOMAC between the groups. No implant related complications were noted in follow-up radiographs. Two minor complications were documented for the STG and three for the MCG. CONCLUSION: We have found no evidence that previous hip arthroscopy negatively influences the performance or short-term clinical outcome of THR.
Resumo:
The treatment of hip osteoarthritis with total hip arthroplasty has continuously evolved since it was first introduced in the sixties. The problem of aseptic loosening of the cemented prostheses, mainly in young active patients, has stimulated two different types of research: on one side the improvement of cementing techniques and on the other side the development of cementless osteoinegrable implants. We discuss the problems of these cementless hip prostheses. Recently published anatomic and biomechanic studies have led to the development of personalized custom femoral stems for each patient. The conception technique and first clinical results are described.
Resumo:
The shortest tube of constant diameter that can form a given knot represents the 'ideal' form of the knot. Ideal knots provide an irreducible representation of the knot, and they have some intriguing mathematical and physical features, including a direct correspondence with the time-averaged shapes of knotted DNA molecules in solution. Here we describe the properties of ideal forms of composite knots-knots obtained by the sequential tying of two or more independent knots (called factor knots) on the same string. We find that the writhe (related to the handedness of crossing points) of composite knots is the sum of that of the ideal forms of the factor knots. By comparing ideal composite knots with simulated configurations of knotted, thermally fluctuating DNA, we conclude that the additivity of writhe applies also to randomly distorted configurations of composite knots and their corresponding factor knots. We show that composite knots with several factor knots may possess distinct structural isomers that can be interconverted only by loosening the knot.
Resumo:
BACKGROUND AND OBJECTIVE: Off-pump coronary artery bypass grafting has stimulated the development of micro-pumps designed to prevent the hemodynamic instability induced by heart luxation for the exposure of target vessels of the posterior wall. Impella (Aachen, Germany) developed micro-pumps with a miniaturized propeller system for both sides of the heart. The aim of this study was to analyze the impact of both pumps working together on blood cell integrity. MATERIALS AND METHODS: Both right and left-sided micro-pumps were implanted in 5 calves (body weight, 72_4 Kg) during 3 h. Blood samples for hematology and hemolysis parameters were drawn hourly. RESULTS: Both pumps performed well with a flow of 3.6 L +/- 0.3 L during the 3 h of the experiment with stable hemodynamic conditions. Mixed venous oxygen saturation was 63.4 +/- 15.2% at baseline and 63.8 +/- 16.3% at the end of the experiment (P = ns). Red cell count, LDH and free plasma hemoglobin were 6.7 +/- 2.1 x 10(12)/L, 1807 +/- 437 IU/L, and 32 +/- 9 mg/L at baseline vs. 6.1 +/- 2.1 x 10(12)/L, 1871 +/- 410 IU/L, and 52 +/- 9 mg/L at the end of the experiment (P = ns for all comparisons). Platelet count exhibited a non-significant drop (872 +/- 126 vs. 715 +/- 22 x 10(9)/L). CONCLUSIONS: This double pump system based on the Archimed screw principle is hematologically well tolerated under conditions of prolonged cardiac assist.
Resumo:
The method of sample recovery for trace detection and identification of explosives plays a critical role in several criminal investigations. After bombing, there can be difficulties in sending big objects to a laboratory for analysis. Traces can also be searched for on large surfaces, on hands of suspects or on surfaces where the explosive was placed during preparatory phases (e.g. places where an IED was assembled, vehicles used for transportation, etc.). In this work, triacetone triperoxide (TATP) was synthesized from commercial precursors following reported methods. Several portions of about 6 mg of TATP were then spread on different surfaces (e.g. floors, tables, etc.) or used in handling tests. Three different swabbing systems were used: a commercial swab, pre-wetted with propan-2-ol (isopropanol) and water (7:3), dry paper swabs, and cotton swabs wetted with propan-2-ol. Paper and commercial swabs were also used to sample a metal plate, where a small charge of about 4 g of TATP was detonated. Swabs were sealed in small glass jars with screw caps and Parafilm® M and sent to the laboratory for analysis. Swabs were extracted and analysed several weeks later by gas chromatography/mass spectrometry. All the three systems gave positive results, but wetted swabs collected higher amounts of TATP. The developed procedure showed its suitability for use in real cases, allowing TATP detection in several simulations, including a situation in which people wash their hands after handling the explosive.