927 resultados para one-step RT-PCR


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the effects of human saliva contamination and two decontamination procedures at different stages of the bonding procedure on the bond strength of two one-step self-etching adhesives to primary and permanent dentin. Materials and Methods: Extracted human primary and permanent molars (210 of each) were ground to mid-coronal dentin. The dentin specimens were randomly divided into 7 groups (n = 15/group/molar type) for each adhesive (Xeno V+ and Scotchbond Universal): no saliva contamination (control); saliva contamination before or after light curing of the adhesives followed by air drying, rinsing with water spray/air drying, or by rinsing with water spray/air drying/reapplication of the adhesives. Resin composite (Filtek Z250) was applied on the treated dentin surfaces. The specimens were stored at 37°C and 100% humidity for 24 h. After storage, shear bond strength (SBS) was measured and data analyzed with nonparametric ANOVA followed by exact Wilcoxon rank sum tests. Results: Xeno V+ generated significantly higher SBS than Scotchbond Universal when no saliva contamination occurred. Saliva contamination reduced SBS of Xeno V+, with the reduction being more pronounced when contamination occurred before light curing than after. In both situations, decontamination involving reapplication of the adhesive restored SBS. Saliva contamination had no significant effect on Scotchbond Universal. There were no differences in SBS between primary and permanent teeth. Conclusion: Rinsing with water and air drying followed by reapplication of the adhesive restored bond strength to saliva-contaminated dentin.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Equine Influenza ist eine durch Influenza A-Viren verursachte, kontagiöse Respirationserkrankung beim Pferd. In dieser Arbeit wurde eine real-time RT-PCR in einem konservierten Abschnitt des Matrix-Segments des viralen Genoms für die schnelle und sensitive Diagnose von equinen Influenzaviren (EIV) und je eine RT-PCR Methode im Matrix- und im HA-Segment für die molekular-epidemiologische Charakterisierung der Viren entwickelt. Die Primer der real-time RT-PCR sind zu 99.4% der bekannten EIV-Sequenzen und zu 97.7% aller Influenza A-Sequenzen homolog. Die Homologie der Minor Groove Binder (MGB)-Sonde lag bei 99.3% und 99.6%. Diese hohen Werte ermöglichen die Anwendung des Assays für Influenzaviren bei anderen Spezies. Die diagnostische Eignung der Methode wurde mit Hilfe von 20 equinen, 11 porcinen sowie 2 aviären Proben verifiziert. Eine hohe Spezifität für Influenzaviren wurde experimentell und mittels Software-Simulation gezeigt. Die analytische Sensitivität des Tests lag bei 102–103 RNA-Kopien und 100–101 DNA-Kopien, was den Virusnachweis auch bei geringer Virusausscheidung ermöglicht. Alle amplifizierten EIV-Sequenzen konnten phylogenetisch den bekannten Linien zugeordnet werden.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Age-related macular degeneration, a major cause of blindness for which no satisfactory treatments exist, leads to a gradual decrease in central high acuity vision. The accumulation of fluorescent materials, called lipofuscin, in retinal pigment epithelial cells of the aging retina is most pronounced in the macula. One of the fluorophores of retinal pigment epithelial lipofuscin has been characterized as A2E, a pyridinium bis-retinoid, which is derived from two molecules of vitamin A aldehyde and one molecule of ethanolamine. An investigation aimed at optimizing the in vitro synthesis of A2E has resulted in the one-step biomimetic preparation of this pigment in 49% yield, readily producing more than 50 mg in one step. These results have allowed for the optimization of HPLC conditions so that nanogram quantities of A2E can be detected from extracts of tissue samples. By using 5% of the extract from individual aged human eyes, this protocol has led to the quantification of A2E and the characterization of iso-A2E, a new A2E double bond isomer; all-trans-retinol and 13-cis-retinol also have been identified in these HPLC chromatograms. Exposure of either A2E or iso-A2E to light gives rise to 4:1 A2E:iso-A2E equilibrium mixtures, similar to the composition of these two pigments in eye extracts. A2E and iso-A2E may exhibit surfactant properties arising from their unique wedge-shaped structures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Kinetic anomalies in protein folding can result from changes of the kinetic ground states (D, I, and N), changes of the protein folding transition state, or both. The 102-residue protein U1A has a symmetrically curved chevron plot which seems to result mainly from changes of the transition state. At low concentrations of denaturant the transition state occurs early in the folding reaction, whereas at high denaturant concentration it moves close to the native structure. In this study we use this movement to follow continuously the formation and growth of U1A's folding nucleus by φ analysis. Although U1A's transition state structure is generally delocalized and displays a typical nucleation–condensation pattern, we can still resolve a sequence of folding events. However, these events are sufficiently coupled to start almost simultaneously throughout the transition state structure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The synthesis of nano-sized ZIF-11 with an average size of 36 ± 6 nm is reported. This material has been named nano-zeolitic imidazolate framework-11 (nZIF-11). It has the same chemical composition and thermal stability and analogous H2 and CO2 adsorption properties to the conventional microcrystalline ZIF-11 (i.e. 1.9 ± 0.9 μm). nZIF-11 has been obtained following the centrifugation route, typically used for solid separation, as a fast new technique (pioneering for MOFs) for obtaining nanomaterials where the temperature, time and rotation speed can easily be controlled. Compared to the traditional synthesis consisting of stirring + separation, the reaction time was lowered from several hours to a few minutes when using this centrifugation synthesis technique. Employing the same reaction time (2, 5 or 10 min), micro-sized ZIF-11 was obtained using the traditional synthesis while nano-scale ZIF-11 was achieved only by using centrifugation synthesis. The small particle size obtained for nZIF-11 allowed the use of the wet MOF sample as a colloidal suspension stable in chloroform. This helped to prepare mixed matrix membranes (MMMs) by direct addition of the membrane polymer (polyimide Matrimid®) to the colloidal suspension, avoiding particle agglomeration resulting from drying. The MMMs were tested for H2/CO2 separation, improving the pure polymer membrane performance, with permeation values of 95.9 Barrer of H2 and a H2/CO2 separation selectivity of 4.4 at 35 °C. When measured at 200 °C, these values increased to 535 Barrer and 9.1.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Includes bibliographies (p. 11).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Silver(I) acetylides allow one-step alkynylation of adamantyl iodide in yields ranging from 25 to 68%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Antigenic variation in Plasmodium falciparum erythrocyte membrane protein 1, caused by a switch in transcription of the encoding var gene, is an important feature of malaria. In this study, we quantified the relative abundance of var gene transcripts present in P. falciparum parasite clones using real-time reverse transcription-polymerase chain reaction (RT-PCR) and conventional RT-PCR combined with cloning and sequencing, with the aim of directly comparing the results obtained. When there was sufficient abundance of RNA for the real-time RT-PCR assay to be operating within the region of good reproducibility, RT-PCR and real-time RT-PCR tended to identify the same dominant transcript, although some transcript-specific issues were identified. When there were differences in the estimated relative amounts of minor transcripts, the RT-PCR assay tended to produce higher estimates than real-time RT-PCR. These results provide valuable information comparing RT-PCR and real-time RT-PCR analysis of samples with small quantities of RNA as might be expected in the analysis of field or clinical samples.