1000 resultados para marcos bernardes de mello
Resumo:
A partir da obra No Tempo D ividido (1954), instala-se uma profunda crise ontológica na poesia de Sophia de Mello Breyner Andresen, motivada pela consciência aguda do tempo enquanto irreversibilidade e finitude. Nas composições poéticas desta fase, a morte surge frequentemente associada ao amor e assume a sua mais profunda forma trágica. A morte é perda irrevocável, escândalo e desintegração da esfericidade do Eros.
Resumo:
Two new lignans, magnovatins A (1) and B (2), along with nine known compounds, were isolated from the leaves of Magnolia ovata. The known compounds were identified as acuminatin (3), licarin A (4), kadsurenin M, 4-O-demethylkadsurenin M, oleiferin A, oleiferin C, spathulenol, parthenolide, and 11,13-dehydrocompressanolide. In addition, compounds I and 2 yielded four new derivatives (1a, 1b, 2a, and 2b). The structures of the new compounds were established on the basis of spectrometric data evaluation. Free-radical scavenging and antimicrobial activities of the major compounds 1, 3, and 4 were investigated.
Resumo:
The essential oils isolated by hydrodistillation from trunk bark and leaves of Talauma ovata A. St. Hil. (Magnoliaceae), collected in four seasons, were analyzed by capillary GC and GC/MS. Altogether 52 components were identified, The oils were characterized by predominance of cyclic sesquiterpenes. The main components were linalool, trans-beta-guaiene, germaerene D, germacrene B, spathulenol, caryophyllene oxide, viridiflorol and alpha-endesmol. The content of individual components was variable during the year. All oils were screened against several strains of bacteria and yeasts, using the agar well-diffusion technique. The antimicrobial activity of oils showed strong dependence with the season. Significant activity was found for oils obtained in the spring and summer.
Resumo:
The genus Roeweria Mello-Leitao, 1923 is revised and a variation on external morphological characters and male genitalia is presented for Roeweria virescens (Mello-Leitao, 1923). The monotypic genus Harpachylus Roewer, 1943 is a junior synonym of Roeweria Mello-Leitao, 1923 because its type-species, H. tibialis Roewer, 1943 is a junior synonym of the type-species Roeweria bittencourti Mello-Leitao, 1923. Roeweria garrincha sp. n. from Cananeia, Sao Paulo, Brazil, is described and can be distinguished from other members of the genus by the presence of a ventral process on the penis and by very large ventral apophyses on the apex of the male femur and patella IV.
Resumo:
The advent of the Auger Engineering Radio Array (AERA) necessitates the development of a powerful framework for the analysis of radio measurements of cosmic ray air showers. As AERA performs ""radio-hybrid"" measurements of air shower radio emission in coincidence with the surface particle detectors and fluorescence telescopes of the Pierre Auger Observatory, the radio analysis functionality had to be incorporated in the existing hybrid analysis solutions for fluorescence and surface detector data. This goal has been achieved in a natural way by extending the existing Auger Offline software framework with radio functionality. In this article, we lay out the design, highlights and features of the radio extension implemented in the Auger Offline framework. Its functionality has achieved a high degree of sophistication and offers advanced features such as vectorial reconstruction of the electric field, advanced signal processing algorithms, a transparent and efficient handling of FFTs, a very detailed simulation of detector effects, and the read-in of multiple data formats including data from various radio simulation codes. The source code of this radio functionality can be made available to interested parties on request. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
The surface detector array of the Pierre Auger Observatory consists of 1600 water-Cherenkov detectors, for the study of extensive air showers (EAS) generated by ultra-high-energy cosmic rays. We describe the trigger hierarchy, from the identification of candidate showers at the level of a single detector, amongst a large background (mainly random single cosmic ray muons), up to the selection of real events and the rejection of random coincidences. Such trigger makes the surface detector array fully efficient for the detection of EAS with energy above 3 x 10(18) eV, for all zenith angles between 0 degrees and 60 degrees, independently of the position of the impact point and of the mass of the primary particle. In these range of energies and angles, the exposure of the surface array can be determined purely on the basis of the geometrical acceptance. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Atmospheric parameters, Such as pressure (P), temperature (T) and density (rho proportional to P/T), affect the development of extensive air showers initiated by energetic cosmic rays. We have Studied the impact of atmospheric variations on extensive air showers by means of the surface detector of the Pierre Auger Observatory. The rate of events shows a similar to 10% seasonal modulation and similar to 2% diurnal one. We find that the observed behaviour is explained by a model including the effects associated with the variations of P and rho. The former affects the longitudinal development of air showers while the latter influences the Moliere radius and hence the lateral distribution of the shower particles. The model is validated with full simulations of extensive air showers using atmospheric profiles measured at the site of the Pierre Auger Observatory. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
From direct observations of the longitudinal development of ultra-high energy air showers performed with the Pierre Auger Observatory, upper limits of 3.8%, 2.4%, 3.5% and 11.7% (at 95% c.l.) are obtained on the fraction of cosmic-ray photons above 2, 3, 5 and 10 EeV (1 EeV equivalent to 10(18) eV), respectively. These are the first experimental limits on ultra-high energy photons at energies below 10 EeV. The results complement previous constraints on top-down models from array data and they reduce systematic uncertainties in the interpretation of shower data in terms of primary flux, nuclear composition and proton-air cross-section. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
The Pierre Auger Collaboration has reported. evidence for anisotropy in the distribution of arrival directions of the cosmic rays with energies E > E(th) = 5.5 x 10(19) eV. These show a correlation with the distribution of nearby extragalactic objects, including an apparent excess around the direction of Centaurus A. If the particles responsible for these excesses at E > E(th) are heavy nuclei with charge Z, the proton component of the sources should lead to excesses in the same regions at energies E/Z. We here report the lack of anisotropies in these directions at energies above E(th)/Z (for illustrative values of Z = 6, 13, 26). If the anisotropies above E(th) are due to nuclei with charge Z, and under reasonable assumptions about the acceleration process, these observations imply stringent constraints on the allowed proton fraction at the lower energies.
Resumo:
To search for new cruzain inhibitors, the synthesis of a series of novel 2-(N`-benzylidenehydrazino)-4-trifluoromethyl-pyrimidines in a convergent manner is presented. The cruzain inhibitory activity of some of these compounds was evaluated and a binding model was proposed. All derivatives tested were active and the most significant inhibitory effect (80% at 100 mu M) and IC(50) value (85 mu M) were obtained from the 2-(N`-4-chloro-benzylidenehydrazino)-4-trifluoromethyl-pyrimidine. Although further structural optimization to improve solubility is necessary, the molecular docking studies suggest that these inhibitors occupy the S2 pocket without irreversible enzyme inactivation, through hydrophobic interactions, thus, indicating a desirable mode of interaction for the design of novel inhibitors. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
We present the results of searches for dipolar-type anisotropies in different energy ranges above 2.5 x 10(17) eV with the surface detector array of the Pierre Auger Observatory, reporting on both the phase and the amplitude measurements of the first harmonic modulation in the right-ascension distribution. Upper limits on the amplitudes are obtained, which provide the most stringent bounds at present, being below 2% at 99% C.L. for EeV energies. We also compare our results to those of previous experiments as well as with some theoretical expectations. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Since data-taking began in January 2004, the Pierre Auger Observatory has been recording the count rates of low energy secondary cosmic ray particles for the self-calibration of the ground detectors of its surface detector array. After correcting for atmospheric effects, modulations of galactic cosmic rays due to solar activity and transient events are observed. Temporal variations related with the activity of the heliosphere can be determined with high accuracy due to the high total count rates. In this study, the available data are presented together with an analysis focused on the observation of Forbush decreases, where a strong correlation with neutron monitor data is found.
Resumo:
The Pierre Auger Observatory is a detector for ultra-high energy cosmic rays. It consists of a surface array to measure secondary particles at ground level and a fluorescence detector to measure the development of air showers in the atmosphere above the array. The ""hybrid"" detection mode combines the information from the two subsystems. We describe the determination of the hybrid exposure for events observed by the fluorescence telescopes in coincidence with at least one water-Cherenkov detector of the surface array. A detailed knowledge of the time dependence of the detection operations is crucial for an accurate evaluation of the exposure. We discuss the relevance of monitoring data collected during operations, such as the status of the fluorescence detector, background light and atmospheric conditions, that are used in both simulation and reconstruction. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Data collected by the Pierre Auger Observatory through 31 August 2007 showed evidence for anisotropy in the arrival directions of cosmic rays above the Greisen-Zatsepin-Kuz`min energy threshold, 6 x 10(19) eV. The anisotropy was measured by the fraction of arrival directions that are less than 3.1 degrees from the position of an active galactic nucleus within 75 Mpc (using the Veron-Cetty and Veron 12th catalog). An updated measurement of this fraction is reported here using the arrival directions of cosmic rays recorded above the same energy threshold through 31 December 2009. The number of arrival directions has increased from 27 to 69, allowing a more precise measurement. The correlating fraction is (38(-6)(+7))%, compared with 21% expected for isotropic cosmic rays. This is down from the early estimate of (69-(+11)(13))%. The enlarged set of arrival directions is examined also in relation to other populations of nearby extragalactic objects: galaxies in the 2 Microns All Sky Survey and active galactic nuclei detected in hard X-rays by the Swift Burst Alert Telescope. A celestial region around the position of the radiogalaxy Cen A has the largest excess of arrival directions relative to isotropic expectations. The 2-point autocorrelation function is shown for the enlarged set of arrival directions and compared to the isotropic expectation. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
The Pierre Auger Observatory is a hybrid detector for ultra-high energy cosmic rays. It combines a surface array to measure secondary particles at ground level together with a fluorescence detector to measure the development of air showers in the atmosphere above the array. The fluorescence detector comprises 24 large telescopes specialized for measuring the nitrogen fluorescence caused by charged particles of cosmic ray air showers. In this paper we describe the components of the fluorescence detector including its optical system, the design of the camera, the electronics, and the systems for relative and absolute calibration. We also discuss the operation and the monitoring of the detector. Finally, we evaluate the detector performance and precision of shower reconstructions. (C) 2010 Elsevier B.V All rights reserved.