981 resultados para laser induced fluorescence detection
Resumo:
In this work three capillary columns, one with uncoated inner wall and two with covalently-bound internal coatings - poly(vinyl alcohol) (PVA) and poly(dimethylacrylamide) (PDMA) - both covalently covered - were used to separate DNA fragments and compared to DNA separation using replaceable polymer solutions. The separations were performed using hydroxyethylcellulose (HEC) (90-105 kDa) in concentrations ranging from 0.00 to 2.00% m/v. The results indicated that the separation efficiency was higher in the PVA capillary than in the PDMA in all evaluated concentrations of HEC. In addition, higher resolution was also observed in PVA-coated capillary since in PDMA the shape of the peaks was not reproducible when subsequent runs were performed. Contrary to what has previously been reported in the literature, no reasonable separation was possible in bare fused silica.
Resumo:
The aim of this study is to quantify the mass transfer velocity using turbulence parameters from simultaneous measurements of oxygen concentration fields and velocity fields. The surface divergence model was considered in more detail, using data obtained for the lower range of beta (surface divergence). It is shown that the existing models that use the divergence concept furnish good predictions for the transfer velocity also for low values of beta, in the range of this study. Additionally, traditional conceptual models, such as the film model, the penetration-renewal model, and the large eddy model, were tested using the simultaneous information of concentration and velocity fields. It is shown that the film and the surface divergence models predicted the mass transfer velocity for all the range of the equipment Reynolds number used here. The velocity measurements showed viscosity effects close to the surface, which indicates that the surface was contaminated with some surfactant. Considering the results, this contamination can be considered slight for the mass transfer predictions. (C) 2009 American Institute of Chemical Engineers AIChE J, 56: 2005-2017; 2010
Resumo:
The supersonic flow around a cylindrical body has been studied using two optical techniques. For both sets of measurements, the cylinder was mounted from the side of the tunnel, allowing investigation of the bow shock region as well as in the wake. A new technique, laser-enhanced ionization flow tagging, was used for streamwise velocity determinations behind the body. From these measurements, it was found that the downstream velocity outside the wake was (1.90 +/- 0.06) km/s, whereas inside the wake the velocity was about 0-500 m/s in the upstream direction. Planar laser induced fluorescence of nitric oxide was employed for temperature determinations. It was established that the freestream temperature was (2120 +/- 100) K, decreasing to around (1550 +/- 400) K in the wake.
Resumo:
For doping control, analyses of samples are generally achieved in two steps: a rapid screening and, in the case of a positive result, a confirmatory analysis. A two-step methodology based on ultra-high-pressure liquid chromatography coupled to a quadrupole time-of-flight mass spectrometry (UHPLC-QTOF-MS) was developed to screen and confirm 103 doping agents from various classes (e.g., beta-blockers, stimulants, diuretics, and narcotics). The screening method was presented in a previous article as part I (i.e., Fast analysis of doping agents in urine by ultra-high-pressure liquid chromatography-quadrupole time-of-flight mass spectrometry. Part I: screening analysis). For the confirmatory method, basic, neutral and acidic compounds were extracted by a dedicated solid-phase extraction (SPE) in a 96-well plate format and detected by MS in the tandem mode to obtain precursor and characteristic product ions. The mass accuracy and the elemental composition of precursor and product ions were used for compound identification. After validation including matrix effect determination, the method was considered reliable to confirm suspect results without ambiguity according to the positivity criteria established by the World Anti-Doping Agency (WADA). Moreover, an isocratic method was developed to separate ephedrine from its isomer pseudoephedrine and cathine from phenylpropanolamine in a single run, what allowed their direct quantification in urine.
Resumo:
We present a study about the influence of substrate temperature on deposition rate of hydrogenated amorphous silicon thin films prepared by rf glow discharge decomposition of pure silane gas in a capacitively coupled plasma reactor. Two different behaviors are observed depending on deposition pressure conditions. At high pressure (30 Pa) the influence of substrate temperature on deposition rate is mainly through a modification of gas density, in such a way that the substrate temperature of deposition rate is similar to pressure dependence at constant temperature. On the contrary, at low pressure (3 Pa), a gas density effect cannot account for the observed increase of deposition rate as substrate temperature rises above 450 K with an activation energy of 1.1 kcal/mole. In accordance with laser‐induced fluorescence measurements reported in the literature, this rise has been ascribed to an increase of secondary electron emission from the growing film surface as a result of molecular hydrogen desorption.
Resumo:
After open coal mining, soils are “constructed”, which usually contain low levels and quality of organic matter (OM). Therefore, the use of plant species for revegetation and reclamation of degraded areas is essential. This study evaluated the distribution of carbon (C) in the chemical fractions as well as the chemical characteristics and humification degree of OM in a soil constructed after coal mining under cultivation of perennial grasses. The experiment was established in 2003 with the following treatments: Hemarthria altissima (T1), Paspalum notatum (T2), Cynodon dactilon (T3), Urochloa brizantha (T4), bare constructed soil (T5), and natural soil (T6). In 2009, soil samples were collected from the 0.00-0.03 m layer and the total organic carbon stock (TOC) and C stock in the chemical fractions: acid extract (CHCl), fulvic acid (CFA), humic acid (CHA), and humin (CHU) were determined. The humic acid (HA) fraction was characterized by infrared spectroscopy and the laser-induced fluorescence index (ILIF) of OM was also calculated. After six years, differences were only observed in the CHA stocks, which were highest in T1 (0.89 Mg ha-1) and T4 (1.06 Mg ha-1). The infrared spectra of HA in T1, T2 and T4 were similar to T6, with greater contribution of aliphatic organic compounds than in the other treatments. In this way, ILIF decreased in the sequence T5>T3>T4>T1>T2>T6, indicating higher OM humification in T3 and T5 and more labile OM in the other treatments. Consequently, the potential of OM quality recovery in the constructed soil was greatest in treatments T1 and T4.
Resumo:
To improve the detectability of tumors by light-induced fluorescence, the use of monoclonal antibodies (MoAb) as carriers of fluorescent molecules was studied. As a model for this approach, the biodistribution of an anticarcinoembryonic antigen (CEA) MoAb coupled to fluorescein was studied in mice bearing a human colon carcinoma xenograft. In vitro, such conjugates with fluorescein-MoAb molar ratios ranging from four to 19, doubly labeled with 125I, showed more than 82% binding to immobilized CEA. In vivo, conjugates with a fluorescein-MoAb molar ratio of ten or less resulted in a tumor uptake of more than 30% of the injected dose of radioactivity per gram tumor at 24 hours. Tumor to liver, kidney, and muscle ratios of 20, 30 and 72, respectively, were obtained 48 hours after injection of the 125I-MoAb-(fluorescein)10 conjugate. The highest fluorescence intensity was always obtained for the tumor with the anti-CEA MoAb conjugate; whereas in control mice injected with fluoresceinated control immunoglobulin G1, no detectable increase in tumor fluorescence was observed. To compare these results with a classically used dye, mice bearing the same xenografts received 60 micrograms of Photofrin II. The intensity of the fluorescence signal of the tumor with this amount of Photofrin II was eight times lower than that obtained after an injection of 442 ng of fluorescein coupled with 20 micrograms of MoAb, which gave an absolute amount of fluorescein localized in the tumor of up to 125 ng/g of tumor. These results illustrate the possibility of improving the specificity of in vivo tumor localization of dyes for laser-induced fluorescence photodetection and phototherapy by coupling them to MoAb directed against tumor markers.
Resumo:
Photodegradation of the PAHs anthracene, chrysene and benzo[k]fluoranthane on silica gel impregnated with TiO2 and over glass plates holding TiO2 was studied. Silica gel plates holding these substances were exposed to solar radiation, developed with hexane and photographed under ultra-violet light. The plates containing benzo[k]fluoranthene were also analysed by both diffuse reflectance and laser induced fluorescence. Diffuse reflectance spectra of the fluorescent spot from non irradiated plates showed small differences when compared with those obtained from irradiated plates. These spectral differences are compatible with formation of less conjugated compounds during irradiation. Fluorescence and time resolved fluorescence spectra observed after irradiation were identical to those obtained with benzo[k]fluoranthene in methanol. On plates holding silica, PAH degradation requires longer periods of solar irradiation when compared with those plates containing silica impregnated with TiO2. Glass plates impregnated with TiO2 also showed very rapid PAH degradation.
Resumo:
Laser-induced fluorescence spectroscopy was used to determine the humification degree of the organic matter of a whole soil, that is, soil without any physical or chemical treatment. Particle size was determined in physically separated fractions. The humification of organic matter, the depth of the soil and the planting system can be correlated. On the surface of the soil, no tillage provided the smallest humification in comparison with the conventional tillage and reduced tillage. The fractions of the superficial layer of the soil (0-20 cm) indicated larger humification in the fraction from 20 to 53 µm and the smallest in the fraction of <2 µm.
Resumo:
Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal
Resumo:
This thesis Entitled Photonic applications of biomaterials with special reference to biopolymers and microbes. A detailed investigation will be presented in the present thesis related to direct applications of biopolymers into some selected area of photonics and how the growth kinetics of an aerial bacterial colony on solid agar media was studied using laser induced fluorescence technique. This chapter is an overview of the spectrum of biomaterials and their application to Photonics. The chapter discusses a wide range of biomaterials based photonics applications like efficient harvesting of solar energy, lowthreshold lasing, high-density data storage, optical switching, filtering and template for nano s tructures. The most extensively investigated photonics application in biology is Laser induced fluorescence technique. The importance of fluorescence studies in different biological and related fields are also mentioned in this chapter.
Resumo:
The vibrational energy levels of diazocarbene (diazomethylene) in its electronic ground state, (X) over tilde (3) Sigma(-) CNN, have been predicted using the variational method. The potential energy surfaces of (X) over tilde (3) A" CNN were determined by employing ab initio single reference coupled cluster with single and double excitations (CCSD), CCSD with perturbative triple excitations [CCSD(T)], multi-reference complete active space self-consistent-field (CASSCF), and internally contracted multi-reference configuration interaction (ICMRCI) methods. The correlation-consistent polarised valence quadruple zeta (cc-pVQZ) basis set was used. Four sets of vibrational energy levels determined from the four distinct analytical potential functions have been compared with the experimental values from the laser-induced fluorescence measurements of Wurfel et al. obtained in 1992. The CCSD, CCSD(T), and CASSCF potentials have not provided satisfactory agreement with the experimental observations. In this light, the importance of both non-dynamic (static) and dynamic correlation effects in describing the ground state of CNN is emphasised. Our best theoretical fundamental frequencies at the cc-pVQZ ICMRCI level of theory, v(1) = 1230, v(2) = 394, and v(3) = 1420 cm(-1) are in excellent agreement with the experimental values of v(1) = 1235, v(2) = 396, and v(3) = 1419cm(-1) and the mean absolute deviation between the 23 calculated and experimental vibrational energy levels is only 7.4 cm(-1). It is shown that the previously suggested observation of the v(3) frequency at about 2847cm(-1) was in fact the first overtone 2v(3).
Resumo:
An experimental technique based on a scheme of vibrationally mediated photodissociation has been developed and applied to the spectroscopic study of highly excited vibrational states in HCN, with energies between 29 000 and 30 000 cm(-1). The technique consists of four sequential steps: in the first one, a high power laser is used to vibrationally excite the sample to an intermediate state, typically (0,0,4), the nu(3) mode being approximately equivalent to the C-H stretching vibration. Then a second laser is used to search for transitions between this intermediate state and highly vibrationally excited states. When one of these transitions is found, HCN molecules are transferred to a highly excited vibrational state. Third, a ultraviolet laser photodissociates the highly excited molecules to produce H and CN radicals in its A (2)Pi electronic state. Finally, a fourth laser (probe) detects the presence of the CN(A) photofragments by means of an A-->B-->X laser induced fluorescence scheme. The spectra obtained with this technique, consisting of several rotationally resolved vibrational bands, have been analyzed. The positions and rotational parameters of the states observed are presented and compared with the results of a state-of-the-art variational calculation. (C) 2004 American Institute of Physics.
Resumo:
Peroxy radicals were measured onboard two scientific aircrafts during the AMMA (African Monsoon Multidisciplinary Analysis) campaign in summer 2006. This paper reports results from the flight on 16 August 2006 during which measurements of HO2 by laser induced fluorescence spectroscopy at low pressure (LIF-FAGE) and total peroxy radicals (RO2* = HO2+ΣRO2, R = organic chain) by two similar instruments based on the peroxy radical chemical amplification (PeRCA) technique were subject of a blind intercomparison. The German DLR-Falcon and the British FAAM-BAe-146 flew wing tip to wing tip for about 30 min making concurrent measurements on 2 horizontal level runs at 697 and 485 hPa over the same geographical area in Burkina Faso. A full set of supporting measurements comprising photolysis frequencies, and relevant trace gases like CO, NO, NO2, NOy, O3 and a wider range of VOCs were collected simultaneously. Results are discussed on the basis of the characteristics and limitations of the different instruments used. Generally, no data bias are identified and the RO2* data available agree quite reasonably within the instrumental errors. The [RO2*]/[HO2] ratios, which vary between 1:1 and 3:1, as well as the peroxy radical variability, concur with variations in photolysis rates and in other potential radical precursors. Model results provide additional information about dominant radical formation and loss processes.
Resumo:
The evaluation of graft function at various stages after transplantation is relevant, particularly at the moment of organ harvest, when a decision must be made whether to use the organ. Autofluorescence spectroscopy is noninvasive technique to monitor the metabolic condition of a liver graft throughout its course, from an initial evaluation in the donor, through cold ischemia transportation, to reperfusion and reoxygenation in the recipient. Preliminary results are presented in six liver transplantations spanning the periods from liver harvest to implant. The laser-induced fluorescence spectrum at 532-mn excitation was investigated before cold perfusion (autofluorescence), during cold ischemia, at the back table procedure, as well as 5 and 60 minutes after reperfusion. The results showed that the fluorescence analysis was sensitive to changes during the transplantation procedure. Fluorescence spectroscopy potentially provides a real-time, noninvasive technique to monitor liver graft function. The information could potentially be valuable for surgical decisions and transplant success.