974 resultados para electricspray ionization mass spectrum


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report on the mid-rapidity mass spectrum of di-electrons and cross sections of pseudoscalar and vector mesons via e(+) e(-) decays, from root s = 200 GeV p + p collisions, measured by the large-acceptance experiment STAR at the Relativistic Heavy Ion Collider. The ratio of the di-electron continuum to the combinatorial background is larger than 10% over the entire mass range. Simulations of di-electrons from light-meson decays and heavy-flavor decays (charmonium and open charm correlation) are found to describe the data. The extracted omega -> e(+) e(-) invariant yields are consistent with previous measurements. The mid-rapidity yields (dN/dy) of phi and J/psi are extracted through their di-electron decay channels and are consistent with the previous measurements of phi -> K+ K- and J/psi -> e(+) e(-). Our results suggest a new upper limit of the branching ratio of the eta -> e(+) e(-) of 1.7 x 10(-5) at the 90% confidence level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The ability of nanoassisted laser desorption-ionization mass spectrometry (NALDI-MS) imaging to provide selective chemical monitoring with proper spatial distribution of lipid profiles from tumor tissues after plate imprinting has been tested. NALDI-MS imaging identified and mapped several potential lipid biomarkers in a murine model of melanoma tumor (inoculation of B16/F10 cells). It also confirmed that the in vivo treatment of tumor bearing mice with synthetic supplement containing phosphoethanolamine (PHO-S) promoted an accentuated decrease in relative abundance of the tumor biomarkers. NALDI-MS imaging is a matrix-free LDI protocol based on the selective imprinting of lipids in the NALDI plate followed by the removal of the tissue. It therefore provides good quality and selective chemical images with preservation of spatial distribution and less interference from tissue material. The test case described herein illustrates the potential of chemically selective NALDI-MS imaging for biomarker discovery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

STUDY BY MASS SPECTROMETRY OF SOLUTIONS OF [HYDROXY(TOSYLOXY)IODO]BENZENE: PROPOSED DISPROPORTIONATION MECHANISMS. Solutions of [hydroxy(tosyloxy)iodo]benzene (HTIB or Koser's reagent) in acetonitrile were analyzed using high resolution electrospray ionization mass spectrometry (ESI-MS) and electrospray ionization tandem mass spectrometry (ESI-MS/MS) under different conditions. Several species were characterized in these analyses. Based on these data, mechanisms were proposed for the disproportionation of the iodine(III) compounds in iodine(V) and iodine(I) species.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Within this PhD thesis matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS) has been used as a reliable tool for the quantitative characterization of giant molecules, such as alkyl substituted and unsubstituted large polycyclic aromatic hydrocarbons (PAH), which cannot be characterized by conventional analytic techniques due to their lack of solubility. The use of the MALDI solvent-free technique for the sample preparation and the application of the standard addition method have allowed the quantitative characterization of synthetic PAH mixtures. The knowledge, acquired by studying these representative systems, has been then transferred to the quantitative analyses of complex and slightly soluble natural PAH mixtures, such as mesophase pitch. Moreover, the possibility to ionize intractable and insoluble molecules via mass spectrometry has been recognized to be not only a powerful analytical method, but also to represent a unique change to handle giant aromatic systems and to deposit them on a surface for further investigations, in a process, which is defined as “soft-landing”. Within this novel deposition technique, ions of the desired analytes or analyte mixtures are generated by means of an MS ionization source, discriminated by their different mass to charge ratios via a mass analyzer and landed with retention of their structure on a desired surface. This soft-deposition is guaranteed by the use of decelerating potentials, which have in this work been recognized to influence the final packing of the analyte molecules reaching the landing surface. For a more detailed study of the electrical field action on disc-like and rod-like molecules, soft-landing-independent experiments have been additionally carried out. As a result unidirectionally ordered films of the analyte molecules have been obtained due to the application of an external electrical strength. This versatile alignment technique has then been used for obtaining ordered layers of semiconducting materials for the fabrication of organic field effect transistors (OFET) with improved performances.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Primary varicella-zoster virus (VZV) infection during childhood leads to varicella commonly known as chickenpox. After primary infection has occurred VZV establishes latency in the host. During subsequent lifetime the virus can cause reactivated infection clinically known as herpes zoster or shingles. In immunodeficient patients’ dissemination of the virus can lead to life-threatening disease. Withdrawal of acyclovir drug prophylaxis puts allogeneic hematopoietic stem-cell transplantation (HSCT) patients at increased risk for herpes zoster as long as VZV-specific cellular immunity is impaired. Although an efficient live attenuated VZV vaccine for zoster prophylaxis exists, it is not approved in immunocompromised patients due to safety reasons. Knowledge of immunogenic VZV proteins would allow designing a noninfectious nonhazardous subunit vaccine suitable for patients with immunodeficiencies. The objective of this study was to identify T cell defined virus proteins of a VZV-infected Vero cell extract that we have recently described as a reliable antigen format for interferon-gamma (IFN-γ) enzyme-linked immunosorbent spot (ELISpot) assays (Distler et al. 2008). We first separated the VZV-infected/-uninfected Vero cell extracts by size filtration and reverse-phase high performance liquid chromatography (RP-HPLC). The collected fractions were screened for VZV reactivity with peripheral blood mononuclear cells (PBMCs) of VZV-seropositive healthy individuals in the sensitive IFN-γ ELISpot assay. Using this strategy, we successfully identified bioactive fractions that contained immunogenic VZV material. VZV immune reactivity was mediated by CD4+ memory T lymphocytes (T cells) of VZV-seropositive healthy individuals as demonstrated in experiments with HLA blockade antibodies and T cell subpopulations already published by Distler et al. We next analyzed the bioactive fractions with electrospray ionization mass spectrometry (ESI-MS) techniques and identified the sequences of three VZV-derived proteins: glycoprotein E (gE); glycoprotein B (gB), and immediate early protein 62 (IE62). Complementary DNA of these identified proteins was used to generate in vitro transcribed RNA for effective expression in PBMCs by electroporation. We thereby established a reliable and convenient IFN-γ ELISPOT approach to screen PBMCs of healthy donors and HSCT patients for T cell reactivity to single full-length VZV proteins. Application in 10 VZV seropositive healthy donors demonstrated much stronger recognition of glycoproteins gE and gB compared to IE62. In addition, monitoring experiments with ex vivo PBMCs of 3 allo-HSCT patients detected strongly increased CD4+ T cell responses to gE and gB for several weeks to months after zoster onset, while IE62 reactivity remained moderate. Overall our results show for the first time that VZV glycoproteins gE and gB are major targets of the post-transplant anti-zoster CD4+ T cell response. The screening approach introduced herein may help to select VZV proteins recognized by memory CD4+ T cells for inclusion in a subunit vaccine, which can be safely used for zoster prophylaxis in immunocompromised HSCT patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Standard Model of particle physics was developed to describe the fundamental particles, which form matter, and their interactions via the strong, electromagnetic and weak force. Although most measurements are described with high accuracy, some observations indicate that the Standard Model is incomplete. Numerous extensions were developed to solve these limitations. Several of these extensions predict heavy resonances, so-called Z' bosons, that can decay into an electron positron pair. The particle accelerator Large Hadron Collider (LHC) at CERN in Switzerland was built to collide protons at unprecedented center-of-mass energies, namely 7 TeV in 2011. With the data set recorded in 2011 by the ATLAS detector, a large multi-purpose detector located at the LHC, the electron positron pair mass spectrum was measured up to high masses in the TeV range. The properties of electrons and the probability that other particles are mis-identified as electrons were studied in detail. Using the obtained information, a sophisticated Standard Model expectation was derived with data-driven methods and Monte Carlo simulations. In the comparison of the measurement with the expectation, no significant deviations from the Standard Model expectations were observed. Therefore exclusion limits for several Standard Model extensions were calculated. For example, Sequential Standard Model (SSM) Z' bosons with masses below 2.10 TeV were excluded with 95% Confidence Level (C.L.).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Standard Model of particle physics is a very successful theory which describes nearly all known processes of particle physics very precisely. Nevertheless, there are several observations which cannot be explained within the existing theory. In this thesis, two analyses with high energy electrons and positrons using data of the ATLAS detector are presented. One, probing the Standard Model of particle physics and another searching for phenomena beyond the Standard Model.rnThe production of an electron-positron pair via the Drell-Yan process leads to a very clean signature in the detector with low background contributions. This allows for a very precise measurement of the cross-section and can be used as a precision test of perturbative quantum chromodynamics (pQCD) where this process has been calculated at next-to-next-to-leading order (NNLO). The invariant mass spectrum mee is sensitive to parton distribution functions (PFDs), in particular to the poorly known distribution of antiquarks at large momentum fraction (Bjoerken x). The measurementrnof the high-mass Drell-Yan cross-section in proton-proton collisions at a center-of-mass energy of sqrt(s) = 7 TeV is performed on a dataset collected with the ATLAS detector, corresponding to an integrated luminosity of 4.7 fb-1. The differential cross-section of pp -> Z/gamma + X -> e+e- + X is measured as a function of the invariant mass in the range 116 GeV < mee < 1500 GeV. The background is estimated using a data driven method and Monte Carlo simulations. The final cross-section is corrected for detector effects and different levels of final state radiation corrections. A comparison isrnmade to various event generators and to predictions of pQCD calculations at NNLO. A good agreement within the uncertainties between measured cross-sections and Standard Model predictions is observed.rnExamples of observed phenomena which can not be explained by the Standard Model are the amount of dark matter in the universe and neutrino oscillations. To explain these phenomena several extensions of the Standard Model are proposed, some of them leading to new processes with a high multiplicity of electrons and/or positrons in the final state. A model independent search in multi-object final states, with objects defined as electrons and positrons, is performed to search for these phenomenas. Therndataset collected at a center-of-mass energy of sqrt(s) = 8 TeV, corresponding to an integrated luminosity of 20.3 fb-1 is used. The events are separated in different categories using the object multiplicity. The data-driven background method, already used for the cross-section measurement was developed further for up to five objects to get an estimation of the number of events including fake contributions. Within the uncertainties the comparison between data and Standard Model predictions shows no significant deviations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lipoproteins are a heterogeneous population of blood plasma particles composed of apolipoproteins and lipids. Lipoproteins transport exogenous and endogenous triglycerides and cholesterol from sites of absorption and formation to sites of storage and usage. Three major classes of lipoproteins are distinguished according to their density: high-density (HDL), low-density (LDL) and very low-density lipoproteins (VLDL). While HDLs contain mainly apolipoproteins of lower molecular weight, the two other classes contain apolipoprotein B and apolipoprotein (a) together with triglycerides and cholesterol. HDL concentrations were found to be inversely related to coronary heart disease and LDL/VLDL concentrations directly related. Although many studies have been published in this area, few have concentrated on the exact protein composition of lipoprotein particles. Lipoproteins were separated by density gradient ultracentrifugation into different subclasses. Native gel electrophoresis revealed different gel migration behaviour of the particles, with less dense particles having higher apparent hydrodynamic radii than denser particles. Apolipoprotein composition profiles were measured by matrix-assisted laser desorption/ionization-mass spectrometry on a macromizer instrument, equipped with the recently introduced cryodetector technology, and revealed differences in apolipoprotein composition between HDL subclasses. By combining these profiles with protein identifications from native and denaturing polyacrylamide gels by liquid chromatography-tandem mass spectrometry, we characterized comprehensively the exact protein composition of different lipoprotein particles. We concluded that the differential display of protein weight information acquired by macromizer mass spectrometry is an excellent tool for revealing structural variations of different lipoprotein particles, and hence the foundation is laid for the screening of cardiovascular disease risk factors associated with lipoproteins.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mass and angular distributions of dijets produced in LHC proton-proton collisions at a centre-of-mass energy root s = 7TeV have been studied with the ATLAS detector using the full 2011 data set with an integrated luminosity of 4.8 fb(-1). Dijet masses up to similar to 4.0TeV have been probed. No resonance-like features have been observed in the dijet mass spectrum, and all angular distributions are consistent with the predictions of QCD. Exclusion limits on six hypotheses of new phenomena have been set at 95% CL in terms of mass or energy scale, as appropriate. These hypotheses include excited quarks below 2.83 TeV, colour octet scalars below 1.86TeV, heavy W bosons below 1.68 TeV, string resonances below 3.61 TeV, quantum black holes with six extra space-time dimensions for quantum gravity scales below 4.11 TeV, and quark contact interactions below a compositeness scale of 7.6 TeV in a destructive interference scenario.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two sets of mass spectrometry-based methods were developed specifically for the in vivo study of extracellular neuropeptide biochemistry. First, an integrated micro-concentration/desalting/matrix-addition device was constructed for matrix-assisted laser desorption ionization mass spectrometry (MALDI MS) to achieve attomole sensitivity for microdialysis samples. Second, capillary electrophoresis (CE) was incorporated into the above micro-liquid chromatography (LC) and MALDI MS system to provide two-dimensional separation and identification (i.e. electrophoretic mobility and molecular mass) for the analysis of complex mixtures. The latter technique includes two parts of instrumentation: (1) the coupling of a preconcentration LC column to the inlet of a CE capillary, and (2) the utilization of a matrix-precoated membrane target for continuous CE effluent deposition and for automatic MALDI MS analysis (imaging) of the CE track.^ Initial in vivo data reveals a carboxypeptidase A (CPA) activity in rat brain involved in extracellular neurotensin metabolism. Benzylsuccinic acid, a CPA inhibitor, inhibited neurotensin metabolite NT1-12 formation by 70%, while inhibitors of other major extracellular peptide metabolizing enzymes increased NT1-12 formation. CPA activity has not been observed in previous in vitro experiments. Next, the validity of the methodology was demonstrated in the detection and structural elucidation of an endogenous neuropeptide, (L)VV-hemorphin-7, in rat brain upon ATP stimulation. Finally, the combined micro-LC/CE/MALDI MS was used in the in vivo metabolic study of peptide E, a mu-selective opioid peptide with 25 amino acid residues. Profiles of 88 metabolites were obtained, their identity being determined by their mass-to-charge ratio and electrophoretic mobility. The results indicate that there are several primary cleavage sites in vivo for peptide E in the release of its enkephalin-containing fragments. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The principal objective of Leg 187 was to locate the Indian/Pacific mantle boundary by sampling and analyzing 8- to 28-Ma seafloor basalts to the north of the Australian Antarctic Discordance (AAD). In this paper we present Sr and Nd isotopic data from basaltic glasses recovered from the 13 sites drilled during Leg 187. Our data show that the boundary region is characterized by a gradual east-west increase in 87Sr/86Sr, with a corresponding decrease in 143Nd/144Nd across a 150-km-wide zone located east and west of the 127°E Fracture Zone. The Sr-Nd isotopic composition of glasses therefore confirms the general conclusions derived by the Leg 187 shipboard scientific party in that the mantle boundary follows a west-pointing, V-shaped depth anomaly that stretches across the ocean floor from the Australian to the Antarctic continental margins. We document that two systematic trends of covariation between 87Sr/86Sr and 143Nd/144Nd can be distinguished, suggesting that the basalts sampled during Leg 187 formed through the interaction of three contrasting source components: (1) a component that lies within the broad spectrum of Indian-type mantle compositions, (2) a boundary component, and (3) a Pacific-type mantle component. The variations in elemental and isotopic compositions indicate that the boundary component represents a distinct mantle region that is associated with the boundary between the Pacific and the Indian mid-ocean-ridge basalt (MORB) sources rather than a dispersed mantle heterogeneity that was preferentially extracted in the boundary region. However, the origin of the boundary component remains an open question. The three components are not randomly intermixed. The Indian and the Pacific mantle sources both interacted with the boundary component, but they seem not to have interacted directly with each other. Large local variability in isotopic compositions of lavas from the mantle boundary region demonstrates that magma extraction processes were unable to homogenize the isotopic contrasts present in the mantle source in this region. Systematic variations in rare earth element (REE) concentrations across the depth anomaly cannot be explained solely by variations in source composition. The observed variations may be explained by an eastward increase and westward decrease in the degree of melting toward the mantle boundary region, compatible with a cooling of the Pacific mantle and a heating of the Indian mantle toward the mantle boundary.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have established a differential peptide display method, based on a mass spectrometric technique, to detect peptides that show semiquantitative changes in the neurointermediate lobe (NIL) of individual rats subjected to salt-loading. We employed matrix-assisted laser desorption/ionization mass spectrometry, using a single-reference peptide in combination with careful scanning of the whole crystal rim of the matrix-analyte preparation, to detect in a semiquantitative manner the molecular ions present in the unfractionated NIL homogenate. Comparison of the mass spectra generated from NIL homogenates of salt-loaded and control rats revealed a selective and significant decrease in the intensities of several molecular ion species of the NIL homogenates from salt-loaded rats. These ion species, which have masses that correspond to the masses of oxytocin, vasopressin, neurophysins, and an unidentified putative peptide, were subsequently chemically characterized. We confirmed that the decreased molecular ion species are peptides derived exclusively from propressophysin and prooxyphysin (i.e., oxytocin, vasopressin, and various neurophysins). The putative peptide is carboxyl-terminal glycopeptide. The carbohydrate moiety of the latter peptide was determined by electrospray tandem MS as bisected biantennary Hex3HexNAc5Fuc. This posttranslational modification accounts for the mass difference between the predicted mass of the peptide based on cDNA studies and the measured mass of the mature peptide.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The function of many of the uncharacterized open reading frames discovered by genomic sequencing can be determined at the level of expressed gene products, the proteome. However, identifying the cognate gene from minute amounts of protein has been one of the major problems in molecular biology. Using yeast as an example, we demonstrate here that mass spectrometric protein identification is a general solution to this problem given a completely sequenced genome. As a first screen, our strategy uses automated laser desorption ionization mass spectrometry of the peptide mixtures produced by in-gel tryptic digestion of a protein. Up to 90% of proteins are identified by searching sequence data bases by lists of peptide masses obtained with high accuracy. The remaining proteins are identified by partially sequencing several peptides of the unseparated mixture by nanoelectrospray tandem mass spectrometry followed by data base searching with multiple peptide sequence tags. In blind trials, the method led to unambiguous identification in all cases. In the largest individual protein identification project to date, a total of 150 gel spots—many of them at subpicomole amounts—were successfully analyzed, greatly enlarging a yeast two-dimensional gel data base. More than 32 proteins were novel and matched to previously uncharacterized open reading frames in the yeast genome. This study establishes that mass spectrometry provides the required throughput, the certainty of identification, and the general applicability to serve as the method of choice to connect genome and proteome.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The binding stoichiometry of gene V protein from bacteriophage f1 to several oligonucleotides was studied using electrospray ionization-mass spectrometry (ESI-MS). Using mild mass spectrometer interface conditions that preserve noncovalent associations in solution, gene V protein was observed as dimer ions from a 10 mM NH4OAc solution. Addition of oligonucleotides resulted in formation of protein-oligonucleotide complexes with stoichiometry of approximately four nucleotides (nt) per protein monomer. A 16-mer oligonucleotide gave predominantly a 4:1 (protein monomer: oligonucleotide) complex while oligonucleotides shorter than 15 nt showed stoichiometries of 2:1. Stoichiometries and relative binding constants for a mixture of oligonucleotides were readily measured using mass spectrometry. The binding stoichiometry of the protein with the 16-mer oligonucleotide was measured independently using size-exclusion chromatography and the results were consistent with the mass spectrometric data. These results demonstrate, for the first time, the observation and stoichiometric measurement of protein-oligonucleotide complexes using ESI-MS. The sensitivity and high resolution of ESI-MS should make it a useful too] in the study of protein-DNA interactions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The interactions of the unpaired thiol residue (Cys34) of human serum albumin (HSA) with low-molecular-weight thiols and an Au(I)-based antiarthritic drug have been examined using electrospray ionization mass spectrometry. Early measurements of the amount of HSA containing Cys34 as the free thiol suggested that up to 30% of circulating HSA bound cysteine as a mixed disulfide. It has also been suggested that reaction of HSA with cysteine, occurs only on handling and storage of plasma. In our experiments, there were three components of HSA in freshly collected plasma from normal volunteers, HSA, HSA + cysteine, and HSA + glucose in the ratio similar to50:25:25. We addressed this controversy by using iodoacetamide to block the free thiol of HSA in fresh plasma, preventing its reaction with plasma cysteine. When iodoacetamide was injected into a vacutaner tube as blood was collected, the HSA was modified by iodoacetamide, with 20-30% present as the mixed disulfide with cysteine (HSA + cys). These data provide strong evidence that 20-30% of HSA in normal plasma contains one bound cysteine. Reaction of HSA with [Au(S2O3)(2)](3-) resulted in formation of the adducts HSA + Au(S2O3) and HSA + Au. Reaction of HSA with iodoacetamide prior to treatment with [Au(S2O3)(2)](3-) blocked the formation of gold adducts. (C) 2003 Elsevier Inc. All rights reserved.